DS 2001 REVISED Humidifier Assembly and Instruction Manual

Similar documents
CUSTOMER SERVICE. Toll-free:

HE120, HE160 Humidifier Installation Kit

HE360 Humidifier Installation Kit

Installation Instructions Owner s Manual

HE220, HE260 Humidifier Installation Kit

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Duct Mount Rotating Drum Humidifier

e Bath Fan with Light User s Guide

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

Safety, Installation, and Operation Manual

Installation Instructions

FREELANCE ORDERING INFORMATION NOTES T01-D

Instant Hot Water Dispenser Owner s Manual

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

TOUCHDOWN 48 CEILING FAN

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

ODEON BEFORE YOU BEGIN ORDERING INFORMATION T01-C , 2006 Copyright Kohler China Ltd.,

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Atomizing Humidifier. Trion

Duct Mount Centrifugal Atomizer Humidifier

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

8707T Includes seat. 8745T Includes Bowl

ST. KITTS CEILING FAN

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED GETTING STARTED

1.6 GALLON ONE PIECE TOILET

FLOW-THROUGH FURNACE HUMIDIFIER

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Bathroom Exhaust Fan/Fluorescent Light Combination

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

Installation Instructions

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

e Bath Fan with Light User s Guide

INSTALLATION INSTRUCTIONS

MEMOIRS VITREOUS CHINA TOILETS

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

Lifetime Limited Warranty

Torrena 42 Ceiling Fan

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

ANTARES ORDERING INFORMATION NOTES T01-G INSTALLATION INSTRUCTIONS

Ceiling Fan Installation Instructions

Camarillo 52 Ceiling Fan

User s Manual and Operating Instructions

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

Irene READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

ELSTON 52 CEILING FAN

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

Duct Mount Atomizing Humidifier

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

ADAIR ORDERING INFORMATION T01-A

INSTANT HOT WATER DISPENSER

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

ELECTRIC FLAT PANEL FIREPLACE HEATER

L I F E T I M E W A R R A N T Y L I F E T I M E W A R R A N T Y 52 VERANDA

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Food Waste Disposer Instruction Manual

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

KD-27A SERIES DISHWASHERS

COUTURE ECO-LITE VITREOUS CHINA REVERSE TRAP TOILETS

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Bathroom Exhaust Fan/Fluorescent Light Combination

SUTTON 52 CEILING FAN

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

Owner s Manual For Models 400, 500, 600 & 700

SAN RAPHAEL GRANDE ORDERING INFORMATION NOTES T01-B INSTALLATION INSTRUCTIOINS 4.8L SKIRTED CLASS FIVE ONE-PIECE TOILET 4.

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

User s Manual and Operating Instructions

52 SAN LUCAS CEILING FAN

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

Residential Steam Humidifier

PL-004-SS. * Proper water pressure is required for simultaneous operations

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

Duct Mounted Atomizing Humidifier. Table of Contents

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Lifetime Limited Warranty

Larson by Hampton Bay

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

WELLWORTH WATERGUARD VITREOUS CHINA SIPHON JET TOILET

52 STRATHMERE CEILING FAN

How your hot water dispenser works

User s Manual and Operating Instructions

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

INSTALLATION INSTRUCTIONS

SPRINGHILL 44 CEILING FAN

Transcription:

DS 2001 REVISED Humidifier Assembly and Instruction Manual Contents Parts list Selecting a location Assembly Hanging the Basin Electrical connections Water connections 2 4 4 Installing the Disk Wheel Installing the Lid and adjusting the water level Connecting the air supply About humidity Startup and shutdown 6 6 Warning Disconnect electrical power to the furnace before starting electrical installation. Electrical shock could result in serious injury. Follow furnace manufacturer's recommendations for wiring of motor power supply. Sharp edges may cause serious injury. Use care when making openings in ducts. Follow local standards and codes. C a ut ion Do not install the humidifier on the furnace jacket, only on the return air duct or plenum. If the heating system also has central cooling, the humidifier supply takeoff must have a damper. The damper should be closed during the cooling season. Do not lubricate any part of your humidifier. It is made from self-lubricating plastics. Do not connect the transformer to multi-speed furnace blower motors or blower motors other than 110 VAC. Turn off the water supply before starting water connection and release pressure in the system by opening a tap or flushing a toilet. Install the water supply valve on household water supply pressure only. Follow furnace manufacturer recommendations for electrical connections if provided. You may want to install this humidifier yourself. If you do, understand that the incorrect use of any tool can cause injury to person or product. Be sure you understand how to use the required tools to avoid any hazards. Arrange for professional installation if required. To ensure that your new humidifier will provide maximum benefit, your furnace must be operating in accordance with the manufacturer's specifications. If your furnace is operating outside of its manufacturer's specifications, your Desert Spring TM warranty could be voided. Ensure that the hot air supply temperature does not exceed 82 Celsius (180 Fahrenheit). Ensure that unit is mounted level. Tha nk Y ou Thank you for selecting the Desert Spring TM Humidifier. This fine product will provide you with years of reliable, low-maintenance service. 1

Parts List Basin 1 Lid 1 Motor plate 1 Air inlet 1 Disk wheel 1 Float 1 Drain 1 Cap 1 Hanger bracket 1 /16" machine screws /16" nuts Humidifier-to-hanger mounting screws Plastic water line 10' Self-piercing valve 1 Water line expander 1 Hot air Take-off 1 Damper plate 1 6" diameter flex duct 1 Duct clamps 2 Hot air Take-off mounting screws 6 Humidistat 1 Marettes (wire nuts) 2 Low voltage electric wire 12' 24 V transformer 1 Templates 2 Instructions 1 Tool Suggestions Variety of small open end wrenches # 1 (green) and # 2 (red) Robertson screwdrivers (square drive) Electric drill with 1/16" and /16" drill bits Tin snips or compass cutter Test meter Pencil or marker Warranty This humidifier is subject to a one (1) year limited warranty issued and guaranteed by the manufacturer. This warranty is void if the unit is damaged by careless handling, improper installation, non-standard operating conditions, or improper maintenance. This warranty is limited to repair or replacement of the humidifier at the discretion of the manufacturer. No other warranty is offered or implied. This warranty is not transferable. All warranty claims must be accompanied by a receipt or record of installation. 2

1. Selecting a location This humidifier is to be mounted on the COLD AIR RETURN (preferably on the narrow side) of a forced air heating system. If the humidifier must be mounted on a plenum/duct which is over 12" wide, the plenum/duct should be reinforced. Ensure that there is sufficient clearance for the humidifier, water supply, and air supply ductwork. If clearance problems exist with utilities, qualified tradespeople should be called. Air is supplied to the humidifier with a flexible duct connected to the air take-off (with sliding damper) mounted on the HOT AIR SUPPLY coming out of the furnace. Follow the instructions on the humidifier TEMPLATE to locate and cut holes for the humidifier and take-off. Note that the top of the rectangular humidifier opening and the top of the round take-off opening should be at the same height if possible. Mount the take-off so that the damper can be easily opened and closed. 2. Assembly Install the float into the slot in the side of the. Hand tighten the nut. wall washer furnace slot in lid tab tab Air Inlet and Motor Plate are Interchangeable* motor plate slot drain washer drain retaining nut valve washer air inlet ball valve (optional) cap overflow hole float Float Assembly stem float adjustment nut Install the drain into the bottom of the and tighten retaining nut securely. Finger tighten these parts ensuring that the drain is centered and does not turn. Do not over tighten. Next install the cap. Optionally, connect a water hose style ball valve and a length of garden hose which extends to a floor drain. The humidifier can be configured with either a right or left air supply. This will depend upon the layout of your furnace.* Snap the motor plate and inlet into the. Ensure that the tabs on these parts fit into the corresponding slots in the. To remove the motor plate and inlet, squeeze the lower tab with pliers and pull upwards. *interchangeable: install air inlet on the side closest to the hot air supply take-off.. Hanging the Basin Hang the from the mounting hanger on the COLD AIR RETURN. See template for instructions to mount the hanger. Use screws to fix to the hanger. Start the screws in the pilot holes and drive through into the back of the bracket. Recommended option: Install two screws in the upper corners of the for added rigidity. opt. screw opt. screw hanger mounts on inside of the cold air plenum (humidifier shown with inlet removed for clarity)

4. Electrical connections Mount the humidistat according to the guidelines supplied in the humidistat box, preferably in the living area. Before making electrical connections ENSURE THAT THE POWER IS OFF! Consult furnace manufacturers recommendations or connect the motor leads as shown below. humidistat supplied wire 110 V AC Source of 110 Volt AC BEST Power to Furnace Motor: humidifier will only operate when furnace does humidifier motor (24 Volt) 24 Volt transformer 110 Volt junction box or knockout on furnace ALTERNATIVE AC from household wiring: humidifier will operate when humidity is low but will be most effective when the furnace is on.. Water connections USE OF SOFTENED WATER IS NOT RECOMMENDED unless you also purchased an Auto Flush. Before starting TURN OFF THE WATER SUPPLY and relieve the pressure. Install the saddle valve on a copper water line as close to the humidifier as possible. CAUTION: ensure that the piercing pin is backed up into the valve body. If installing on galvanized pipe, pre drill a 1/8" diameter hole that the piercing pin fits into. Assemble one side of the top clamp to the bottom clamp and place over the water line ensuring that the rubber gasket is in place over the piercing pin. Assemble the other side of the top clamp to the bottom clamp with remaining fastener and tighten evenly until unit is firmly attached to water pipe. Connect suppled plastic water line to valve and float as shown below. Use the plastic compression fitting and insert in the valve end of plastic line; use the expander in the float end. If using copper line, use metal compression sleeves. Turn the valve handle clockwise fully to pierce the water pipe. NOTE: This is the off position. Basin Expander Compression sleeve (plastic) Rubber gasket Insert Saddle valve clamp Household water line Piercing pin Float Plastic water line Compression sleeve (metal) Saddle valve body Copper water line (not supplied) 4

6. Installing the Disk Wheel Using the tabs as indicators, lower the disk wheel assembly into the V-guides on the inlet and motor plates. Ensure that the inlet end of the axle is seated in the bearing at the bottom of the V-guide and that the gear on the other end of the axle is engaged with the motor gear. disk wheel tab v-guide tab v-guide motor gear bearing ensure tabs on inlet and motor plate fit into slots in lid flanges water float adjustment slot overflow hole* stop *(punch out if required) 7. Installing the Lid and adjusting the water level Fit the lid onto the. Turn on the water supply and check for any leaks. The float assembly should be adjusted so that the height of the water is within the range indicated by the textured bands on the inside sides of the. The water should just cover the disks (look into the inlet to see the water level). Adjust the float as required. Do not lift installed float against stop or damage to float seal can occur. Secure the float adjustment nut with a 9/16" wrench. As an additional convenience, you may wish to run a hose from the overflow hole to your floor drain. The necessary parts are available from your local plumbing supplier. 8. Connecting the air supply Use one of the supplied wire clamps to hold the flex ducting to the air take-off. Use the remaining wire clamp to secure the flex duct to the humidifier's inlet. For maximum efficiency, do not let the flex duct sag. If you need to trim the length of the flex duct ensure that you cut the ends square. If the humidifier is far enough from the take-off to cause strain on the ducting, it may be necessary to buy a longer flex duct at your local hardware store. Ensure damper is in the open position. damper shown in closed position

9. About humidity Humidity requirements will vary from home to home. Your comfort level is the best gauge of the correct humidity. If your windows are fogged then you have too much humidity. If there is no moisture visible in the window corners and along the edges then you could have too little humidity. In some cases it may take a week or more for the humidity to build up to the proper level. Humidity buildup will be hampered by sloppy fitting (or open) windows and doors, exhaust fans, open fireplace dampers, house plants, and large attics. Some types of carpets produce static electricity even with the correct humidity. Too much humidity can cause damage to your home and furnishings, and can promote the growth of household molds and fungi. In order to determine the safe relative humidity for homes exposed to various low outside temperatures, tests were conducted and recommended humidity levels are shown in the chart below. These levels help prevent damage to your house such as water running down walls or even building up inside of walls. As a general guide the maximum humidity level is attained when moisture just appears in the corners of your windows. Outside Air Temperature Recommended Control Setting -0 C/-20 F 1 % -2 C/-10 F 20 % -20 C/0 F 2 % -10 C/10 F 0 % - C/20 F % >0 C/20 F 40 % 10. Startup, maintenance and shutdown Turn on the water supply to the humidifier (if it has not been previously done), turn on the electrical power and adjust the humidistat so that the humidifier starts. Adjust humidistat to the desired setting. Regularly change the setting in accordance with the outside temperature. At the end of the humidifying season, turn off the water, remove the disk wheel, agitate the water in a circular motion and drain the sediment and any water from the. Replace the disk wheel and lid. Turn the humidistat off. Slide the damper to the closed position. Under normal conditions, minimal maintenance should be required. If you live in an area where the mineral content of the water is high (hard water), you may wish to drain the sediment as described above and periodically clean any minor sediment deposits from the and disk wheel. Use vinegar or any cleaner approved for plastic. After soaking in vinegar or cleaning solution, the disk wheel should be rinsed. Over time metal parts may discolor. This is a normal reaction and will not affect performance. For excessive mineral buildup, lower water level using ball valve and scoop minerals out. Hardened minerals will break off cleanly with minimal effort. Disclaimer Except as expressly stated in this manual, ATI Manufacturing Ltd. makes no representation or warranty with respect to the humidifier and disclaims all implied warranties including any warranty of merchantability or fitness for a particular purpose. In no event will ATI Manufacturing Inc. be liable to any customer or user of the humidifier for any indirect, incidental, or consequential damages or loss of revenues or profits, whether the same are foreseeable or not, occasioned by any cause whatsoever including, but not limited to, the installation or operation of the humidifier. 6

DESERT SPRING HUMIDIFIER MOUNTING TEMPLATE TO USE TEMPLATE: -Cut out opening from paper, retain inside as instruction sheet, outside as template. -Tape template onto RETURN duct/plenum so that it is level and draw the opening shape onto the duct. -Drill starter hole in a corner, cut out opening with tin snips. Use care to cut opening accurately. CAUTION - CUT EDGES ARE VERY SHARP. -Hold hanger bracket against duct/plenum so that the bottom of the hanger bracket is about 1/2" from the top edge of the opening in the duct/plenum. Ensure that it is level and mark the three mounting bolt locations. Drill three /16" holes in the duct/plenum. Mount the hanger bracket on the inside of the duct/plenum using the /16" machine screws and nuts. Hanger may be dropped up to /4" to accommodate larger preexisting holes. 1/2" Hold hanger level and mark hole locations Drill holes Hanger Installed inside plenum/duct Damper HOT AIR SUPPLY TEMPLATE -Template is the cardboard cradle used to ship the disk wheel. -Hold Hot Air Take-off against the HOT AIR supply and trace inside the opening. -Drill a starter hole inside the line and cut with compass cutter or tin snips. -Hold the air take-off over the opening and mark the screw locations. -Drill 1/16" pilot holes or drive the screws directly into the SUPPLY duct. -Slide the damper into place before final tightening of the mounting screws. -Rotation of the air take-off depends on your clearance. Air Take-off starter hole