HE225A,B and HE265A,B Bypass Flow-Through Humidifier

Similar documents
HE365A,B Powered Flow-Through Humidifier

HE365A,B Powered Flow-Through Humidifier with

HE360A,B Powered Flow-Through Humidifier

HE365A,B Powered Flow-ThroughHumidifier with

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

HE365A,B Powered Flow-ThroughHumidifier with JI

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

HE360 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit

HE360 Powered Flow-Through Humidifier

HE120, HE160 Humidifier Installation Kit

HE420A Steam Power Humidifier

F200E Charged-Media Air Cleaner

F150E Media Air Cleaner

H1008A,D Automatic Humidity Controls

The T6140A,B Remote Bulb Temperature Controller

Comfort, Energy & Health Solutions

T4398A,B High Performance Electric Heat Thermostats

F25F Media Air Cleaner

T4098A,B Deluxe Electric Heat Thermostats

C554A Cadmium Sulfide Flame Detector

T7079A,B Solid State Remote Temperature Controllers

Comfort, Energy & Health Solutions. Your family. Your home. Your comfort and peace of mind. Indoor Air Quality

Installation Instructions

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T6984F,G Electronic Floating Control Thermostats

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

IS Series Pressure Sensing Switches

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

CR7075 Two-Stage Lighting Controller

Commercial/Industrial Combustion Control Level Three Announcement

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

UV100E Ultraviolet Air Treatment System

C6097A,B Pressure Switches

T4398A,B Precision Electric Heating Thermostat

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

Installation Instructions Owner s Manual

CT500 Electronic Thermostat

F112A,C; F113A,C Portable Air Cleaners

T7984 A,B,C Electronic Modulating Control Thermostats

T8602C Chronotherm IV Deluxe Programmable Thermostats

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

T8611M Deluxe Programmable Heat Pump Thermostats

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

FLOW-THROUGH FURNACE HUMIDIFIER

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

Deluxe Programmable Thermostats

T8600D Chronotherm IV Deluxe Programmable Thermostats

HEALTHY CLIMATE HUMIDIFIER

Continue to next pages for Template instructions, Owners Guide, Humidistat Instructions.

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

T8411R Electronic Heat Pump Thermostat

MODEL HUM HUMIDIFIERS

L8151A Triple Aquastat Relay

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

T8011R Programmable Heat Pump Thermostat

T8524 Deluxe Electronic Thermostat

Electrode Steam Homeowner s Manual HOMEOWNER S OPERATING MANUAL EFS-01

UV100A Ultraviolet System

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

C7004B Flame Rod Holder

Installation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

T6984 A,D,E Electronic Floating Control Thermostats

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Deluxe Programmable Heat Pump Thermostat T8611M

FLOW-THROUGH FURNACE HUMIDIFIER

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

Heat Recovery Ventilation Systems OWNER S GUIDE

Owner s Manual For Models 400, 500, 600 & 700

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

T834C Heating-Cooling Thermostat

T874 Multistage Thermostat and Q674 Subbase

CT2800 Programmable Thermostat

Owner s Manual. Humidifiers. For Models 350, 360, 400, 400M, 500, 500M, 600, 600M, 700 & 700M

G-100ES Duct Mount Humidifier

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

CT2700 An Electronic Round Programmable Thermostat

Must be installed by a trained, experienced technician

T7200D,E Series 2000 Commercial Microelectronic Thermostats

OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS MODELS 4000, 5000, 6000 & 7000 HUMIDIFIERS. Includes Safety, Operating and Maintenance Instructions

Honeywell Steam Humidifier Operates independently to maintain optimal humidity

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

RA889A Switching Relay

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

Instructions For A and Flame Simulators

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

Duct Mount Atomizing Humidifier

G-100ES Duct Mount Humidifier

INSTALLATION INSTRUCTIONS

Owner s Manual. For Models 350, 360, 400A, 500A, 500M, 600A, 600M, 700A & 700M. Includes Safety & Operating Instructions and Warranty Information

Transcription:

whole-house air quality system HE225A,B and HE265A,B Bypass Flow-Through Humidifier FEATURES/BENEFITS PRODUCT DATA Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad. Bold new look with blue and white styling. Proven technology used for high performance humidification and enhanced comfort. Preassembled for quicker installation. Small footprint, light weight and reversible components allow easy mounting on either warm air supply or return air duct of any forced air furnace. Interior components designed for quick maintenance and service. Includes easy-to-use humidity control that mounts on the wall or duct for more flexible installation. Continuous flushing reduces the frequency of maintenance in a hard water installation. APPLICATION The Enviacaire Elite HE225A,B and HE265A,B Bypass Flowthrough Humidifiers use the warm air furnace blower to provide humidification for the whole house. AIRWATCH Indicator can be installed to remind homeowner to change humidifier pad. Five-year warranty. U.S. Registered Trademark Copyright 2000 Honeywell All Rights Reserved 68-0244

SPECIFICATIONS Capacity: At 120 F (49 C) plenum temperature and 0.20 static pressure drop across supply and return: HE225A,B: 12 gallons per day (gpd) or 46 liters per day (lpd). HE265A,B: 17 gallons per day (gpd) or 65 liters per day (lpd). Electrical Ratings: 24 Vac, 60 Hz, 0.5A. Humidified Area: See Table 1. Humidifier Pad Dimensions: See Table 2. Plenum Opening Dimensions (Height x Width): See Table 3. Summer Shut-off Damper Dimensions (Height x Width): See Table 4. Bypass Duct Opening (Diameter): 6 in. (152 mm). Drain Connection: 1/2 in. (13 mm) I.D. plastic hose connected directly to drain fitting on unit. Dimensions: Refer to Fig. 1 and 2. Table 1. Size Of Area That Can Be Humidified. HE225 Area (Up To) HE265 Area (Up To) House Description Air Changes Per Hour Sq ft Sq m Sq ft Sq m Loose Two 750 70 1,000 93 Average One 1,500 140 2,000 186 Tight One-half 3,000 280 4,000 372 Table 2. Dimensions Of Humidifier Pads In In. (mm). Model Height Width Depth HE225 9-13/16 (249) 9-1/2 (241) 1-1/2 (38) HE265 13 (330) 10 (254) 1-1/2 (38) Table 3. Dimensions Of Plenum Opening In In. (mm). Table 4. Dimensions Of Summer Shut-off Damper In In. (mm). Model Height Width HE225 9-3/16 (234) 8-7/8 (226) HE265 12-3/8 (314) 9-5/16 (236) Model Height Width HE225 9-7/16 (241) 9-5/16 (238) HE265 12-5/8 (321) 9-3/4 (248) ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1985 Douglas Drive North, MN10-1461 Golden Valley, Minnesota 55422-4386 1-800-468-1502 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarbouorgh, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0244 2

9-1/8 (232) 11-7/16 (290) Standard: Air Conditioning and Refrigeration Institute Tested: Standard 610. 12 (305) 12-7/16 (316) Models: HE225A TRADELINE and HE265A TRADELINE Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H8908B Convertible Humidity Control. HE225B TRADELINE and HE265B TRADELINE Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H1008A Automatic Humidity Control with HumidiCalc Software. 13-9/16 (345) 6 (152) DIAMETER Fig. 1. Dimensions of HE225A,B in in. (mm). M14818 Accessories: Current Sensor Relay, part no. 32001754-001. C7089H Outdoor Temperature Sensor. H8908B Convertible Humidity Control. H1008A Automatic Humidity Control with HumidiCalc+ Software (software calculates dewpoint to prevent moisture condensation). HC22E Antimicrobial Humidifier Pad (HE225A,B only). HC26E Antimicrobial Humidifier Pad (HE265 A,B only). HumidiCalc+ Humidifier Sizing Software (software calculates required humidifier capacity for application). PC8900 Control. S688 Sail Switch. 9-1/4 (235) 13-9/16 (345) 12 (305) INSTALLATION WARNING Hazardous Voltage. Can cause personal injury or equipment damage. Do not cut or drill into any air conditioning line or electrical accessory. 16-3/4 (425) 6 (152) DIAMETER 15-5/16 (390) M14819 CAUTION Freezing Water, Flooding or Static Pressure Hazard. Can cause water damage to home or permanent equipment damage. The humidifier must be located where the ambient temperature is above 32 F and below 160 F (0 C and 71 C). Be sure supply plenum static pressure is no greater than 0.3 in. w.c. and water pressure is no greater than 125 psi. IMPORTANT To assure optimal product performance, be sure the template is level before marking location. Fig. 2. Dimensions of HE265A,B in in. (mm). 1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 3. Approvals: Underwriters Laboratories Inc. Listing: 56 BL. Canadian Underwriters Laboratories Inc. Listing: 56 BL. 3 68-0244

11. Reinstall the humidifier pad assembly in the humidifier housing. HORIZONTAL HIGHBOY Be sure the water feed tube is not pinched or kinked. 12. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover. WATER FEED NOZZLE DOWN FLO LOWBOY HUMIDIFIER PAD ASSEMBLY FRAME M12248C Fig. 3. Typical humidifier installation locations. COVER SIDEWALL IMPORTANT Mount the humidifier at least 3 in. (76 mm) above the furnace jacket to allow adequate space for the solenoid valve and drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover. 2. Tape the template in position and trace around the template. 3. Remove the template and carefully cut the rectangular opening. 4. Disassemble the humidifier; remove the cover and take out the humidifier pad assembly. See Fig. 4. Sidewalls are interchangeable for either left or right by-pass installation. To change direction, remove the screws holding each sidewall, switch sidewall locations and reinstall the screws. 5. Position the humidifier housing in the opening (be sure it is level), so the locking tabs are in place on the lower sheet metal edge of the opening. 6. Secure the humidifier housing to the opening at the top and bottom using sheet metal screws. 7. Locate the other plenum and cut an opening for a 6 in. (152 mm) collar. 8. Install the 6 in. (152 mm) collar. Be sure to install a duct damper for summer shutoff on systems with air conditioning. 9. Install a 6 in. (152 mm) diameter duct from the collar to the humidifier. Some installations require a 90 elbow attachment to the collar. 10. Seal the duct connections with duct tape. To avoid sagging and stress on the humidifier, add support when ducting is longer than 4 ft (120 cm). BY-PASS SIDEWALL Fig. 4. Humidifier components. WIRING THE HUMIDIFIER CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Disconnect the power supply before installing or servicing. On multispeed blower applications, do not wire the high voltage side of the transformer to the same power source that services the furnace blower. Premature transformer burnout may occur. All wiring must comply with applicable local codes, ordinances and regulations. 1. Mount the transformer in a convenient location. 2. Connect wires to the 120V side of the transformer. 3. Wire the humidifier solenoid valve, current sensing relay, or sail switch, humidity control and transformer. Refer to the humidity control installation instructions for mounting and wiring information. HUMIDIFIER HOUSING WATER FEED TUBE M14672 Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed. 68-0244 4

0 F -5 C Over 20 F Over 0 C HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER PLUMBING THE SADDLE VALVE Hot or cold water, either hard or softened, can be used in the humidifier. 1. Use the self-piercing saddle valve (included) to tap into the water supply line at an appropriate location. IMPORTANT The saddle valve is not designed to regulate water flow. The valve is either open or closed. To prevent debris from clogging the solenoid inline filter, be sure to install the saddle valve handle pointing toward the ceiling. Lightly clean the copper tubing ends with fine sandpaper before making any connections. 2. Use 1/4 in. O.D. copper tubing and connect the saddle valve to the inlet side of the solenoid valve. CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. a. Place the brass compression nut over the copper tubing. Do not over tighten the compression nut. Moderate tightness prevents leaking. b. Slide the brass ferrule over the tubing. c. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut. 3. Connect a 1/2 in. (13 mm) drain tube to the humidifier drain fitting and run to a suitable drain. Slope the drain tube downward for correct drainage. CHECKING THE INSTALLATION Use the following procedure to check out the humidifier installation: 1. Open the saddle valve. 2. Set the thermostat setpoint to 10 F (6 C) above the room temperature. The furnace blower must be on for the humidifier to operate. 3. Set the Convertible Humidity Control to a high setting, or place the H1008A Automatic Humidity Control in the Test position. 4. Observe the water running out of the drain line to be sure the humidifier is working. 5. Check for leaks. 6. Reset the thermostat and Convertible Humidity Control to a comfortable setting, or the Automatic Humidity Control to the desired frost factor setting, for automatic operation. OPERATING THE HUMIDIFIER The HE225A and HE265A Humidifiers are controlled by the Convertible Humidity Control that is installed either on an interior wall in the living area or on the return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on the humidity control dial. Match the H8908A dial setting to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on inside windows. Table 5 can also be used to adjust the humidity control to the recommended setting. As the outside temperature drops, the recommended setting is lowered to accommodate the effects of dewpoint. These settings should reduce the accumulation of moisture and ice on the windows and in other areas of the house. Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on the windows. Humidity Control Régulateur d'humidité OUTDOOR TEMPERATURE If this condition persists for more than a few hours, set the humidity control to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture. The Enviracaire Elite HE225B and HE265B Humidifiers are controlled by the Honeywell H1008A Automatic Humidity Control with HumidiCalc+ Software. The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air. The HumidiCalc+ Software inside the automatic humidity control H1008A is designed to automatically adjust the humidity level based on indoor temperature and humidity, inferred or measured outdoor temperature, and the setting of the frost factor dial. The frost factor allows for variations in furnace size, window insulation and average daily climate temperature. M12817 The Automatic Humidity Control with HumidiCalc+ Software requires an initial adjustment period. Set the frost factor dial on 5 and use Table 6 to adjust the frost factor only one setting at a time increasing the dial setting for more humidity, or reducing the setting if moisture develops on inside windows. For more precise humidity adjustment, set the frost factor between dial settings. Allow two days for the humidity level to subside before making further adjustments. Once the proper setting has been found, no further adjustment is needed. HumidiCalc+ Software takes over and makes any future adjustments caused by varying outdoor temperatures, thus reducing moisture build-up on windows while maintaining the optimal humidity level. -20 F -10 F +10 F +20 F -30 C -25 C -20 C -10 C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% M14694 5 68-0244

Table 5. Recommended Convertible Humidity Control Settings. At Outside Temperature Recommended Setting At Outside Temperature Recommended Setting -20 F (-29 C) 15 +10 F (-12 C) 30-10 F (-23 C) 20 +20 F (-7 C) 35 0 F (-18 C) 25 Above 20 F (-7 C) 40 Insufficient humidity Humidity Level Condensation on windows Table 6. Recommended Frost Factor Settings. Recommended Adjustment Increase the frost factor dial by one setting. Decrease the frost factor dial by one setting. OPERATION The HE225A,B and HE265A,B Humidifiers use the principle that vapor (evaporated water) is created when warm air blows over a water soaked area. As the vapor circulates, the relative humidity rises. The humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that disburses water over an antimicrobial humidifier pad. The warm dry air from the furnace passes over the humidifier pad and collects moisture and them circulates it through the house. Every 1 to 3 Months (Depending on Water Quality) Use the following procedure to clean the humidifier: 1. Disconnect the power and turn off the humidifier water supply. 2. Remove the humidifier cover. See Fig. 5. WATER FEED NOZZLE Humidified air feels warmer and more comfortable so the homeowner may be able to lower the thermostat heating setpoint and save money on heating fuel bills. The end result is that the humidifier gives the homeowner a comfortable environment that is also energy efficient. MAINTENANCE A regular maintenance program prolongs the life of the humidifier and provides a more comfortable environment. Either hard or soft water can be used in the humidifier. Frequency of cleaning depends on the condition of the water. COVER SIDEWALL HUMIDIFIER PAD ASSEMBLY FRAME CAUTION Voltage Hazard. Can cause electrical shock and equipment damage. Disconnect power supply before installing or servicing. IMPORTANT Never oil any part of the humidifier. BY-PASS SIDEWALL HUMIDIFIER HOUSING WATER FEED TUBE Fig. 5. Location of humidifier parts. M14672 3. Remove the humidifier pad assembly from the humidifier by grasping the tray and pulling it toward you. 4. Pull one side of the humidifier pad assembly frame toward you and remove the tray from the frame. 5. Gently pinch the water nozzle catches inward until the water nozzle can be lifted off the tray. 6. Slide the antimicrobial humidifier pad out of the frame. 7. Carefully scrape any mineral deposits from the tray and frame. Be sure the frame drain hole has nothing blocking it. 68-0244 6

8. Check the humidifier pad and if excessive mineral deposits are present, replace with a new antimicrobial pad. 9. Disconnect the tube from the drain fitting on the bottom of the humidifier housing. 10. Clean the drain fitting, if necessary. 11. Bend the drain tube to loosen any mineral deposits. 12. Flush the drain tube with pressurized water (a running tap) to clean the tube. 13. Reattach the drain tube to the drain fitting. 14. Slide the humidifier pad back into the frame. IMPORTANT To maintain the antimicrobial properties of the humidifier, use only a Honeywell HC22E or HC26E Antimicrobial Pad. See Table 8 List of Replacement Parts for appropriate pad. Be sure the marked side of the antimicrobial humidifier pad is facing up for proper performance. 15. Snap the water nozzle back on the tray. 16. Reattach the tray to the frame. 17. Place the humidifier pad assembly in the humidifier housing and press until the assembly is completely seated. Be careful not to pinch or kink the water feed tube. 18. Replace the humidifier cover. 19. Verify the humidifier operation by following the steps in the Checkout Procedure section. End of Humidification Season At the end of the heating season, follow steps 1 through 18 from the Every 1 To 3 Months section to clean the humidifier and shut if off. IMPORTANT Be sure the humidifier power is off. Beginning of Humidification Season Refer to the Checkout Procedure section to complete the humidifier startup. Vacation When leaving on vacation, turn off the humidifier water supply and the humidity control. When returning from vacation, turn on the humidifier water supply and reset the humidity control to restart the humidifier. CHECKOUT PROCEDURE After winter startup or servicing, use the following procedure to check the humidifier operation: 1. Turn on the humidifier power and water supply. 2. Turn the Convertible Humidity Control to the highest setting, or place the H1008A Automatic Humidity Control in the Test position and set the thermostat to 10 F (6 C) above the room temperature. 3. Observe that water is flowing out of the drain hose. The furnace blower must be on for the humidifier to operate. 4. Reset the thermostat and Convertible Humidity Control to a comfortable setting, or the H1008A Automatic Humidity Control to the desired frost factor setting, for automatic operation. TROUBLESHOOTING Refer to Table 7 for troubleshooting procedures. Problem What To Look For What To Do Low humidity Furnace blower not operating Reset circuit breaker or check for blown fuse. Check that the furnace power is on. Check all external wiring connections. Check the humidity control setting. Call a professional heating contractor. Rapid air changes. Drafts (cold air is dry and is an added load to the humidifier). Table 7. Troubleshooting Procedures. Keep doors and windows closed. Close fireplace damper when not in use. Keep exhaust fan running time to a minimum. Seal around doors and windows. High humidity Condensation on walls. Turn humidity control and water off until condensation is completely evaporated. Heavy condensation on windows. Turn humidity control down low enough to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. If moisture persists, more ventilation is needed. 7 68-0244

REPLACEMENT PARTS Refer to Fig. 6 and Table 8 when ordering replacement parts. 10 4 9 8 30 40 20 11 10 OFF ON 50 60 5 6 12 3 13 7 1 8 Fig. 6. Exploded view of humidifier parts. 2 8 M14820 68-0244 8

Table 8. List Of Replacement Parts For HE220A,B, HE260A,B Humidifiers. Exploded View Number Description HE225 Part Number HE265 Part Number 1 Side wall 32001612-002 32001626-002 2 Bypass side wall 32001613-002 32001627-002 3 Cover Assembly 32001611-003 32001611-004 4 PerfectFlo water distribution tray 32001619-001 32001630-001 5 Antimicrobial humidifier pad HC22E1003 HC26E1004 6 Frame 32001621-001 32001632-001 7 Drain fitting 32001615-001 32001615-001 8 Solenoid valve assembly (includes water feed tube and nozzle) 32001639-002 32001639-002 9 Saddle valve assembly 32001616-001 32001616-001 10 Transformer (10 VA) 32001652-001 32001652-001 11 Convertible Humidity Control H8908B1002 H8908B1002 12 Automatic Humidity control with HumidiCalc + Software H1008A1008 H1008A1008 13 Base insert assembly, includes no. 8 above 32001625-003 32001625-004 Hardware Kit for Solenoid Assembly (same as Solenoid valve assembly without the solenoid valve) 32001752-001 32001752-001 Current Sensing Relay 32001754-001 32001754-001 9 68-0244

68-0244 10

11 68-0244

IMPROVE YOUR INDOOR AIR WITH A COMPLETE whole-house air quality system ULTRAVIOLET AIR TREATMENT SYSTEM ZAP airborne germs. Kill most germs before they recycle through your home. Prevent mold spores from growing on your system cooling coils. F300E ELECTRONIC AIR CLEANER TRAP airborne particles. Up to 99% efficient at capturing airborne particles. Effectively REDUCES fungi, bacteria, mold antigen, cat antigen and ragweed pollen antigen that pass through system. ENVIRACAIRE ELITE HUMIDIFIERS Moisturize parched air. Help maintain proper humidity to minimize adverse health effects. Features special antimicrobial agent to prevent surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad. Honeywell offers one of the broadest families of home solutions in the industry - ranging from thermostats, zoning, ventilation, air cleaning, humidification to internet-enabled home control and wireless WebPAD devices for web surfing and more!! Check out our offerings on-line at www.honeywell.com/yourhome/... only from Honeywell. M14757 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled 68-0244 G.H. 11-00 paper containing at least 10% post-consumer 12paper fibers. www.honeywell.com/yourhome/