Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance

Similar documents
SLOT PSW LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions Labor and Delivery Exam Light Set

DHL-LP-LED Low Profile LED Linear High/Low Bay

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

MaxLite LED Round Pendant Highbay Series

Installation Instructions. Tersen. Ratio Canopy 1.5

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

MaxLite LED Vapor Tight Linear Fixture

MaxLite LED MICRO-T PANEL

INSTALLATION INSTRUCTIONS

MaxLite LED High Bay Fixtures

Installation Instructions

USER GUIDE & INSTALLATION INSTRUCTIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

USER GUIDE & INSTALLATION INSTRUCTIONS

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

Innovative Lighting R-Series Overhead LED Conversion Kits

Lumination TM Volumetric Retrofit Kit

HIGH LUMINOUS EFFICIENCY

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

110 lm w STANDARD SERIES

Innovative Lighting Smooth Light Recessed Luminaires

Innovative Lighting R-Series Vertical Refrigeration

LED Shoplight fixture

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

WPLED 26W INSTALLATION INSTRUCTIONS

USER S INFORMATION MANUAL

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

EcoVision Door Manual

INSTALLATION GUIDE. pg.1

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

52 CEILING FAN. Owner s Manual Models #50336, 50337

Dimmable LED Retrofit Kit

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

installation and operation manual for Hunter Ceiling Fans

INSTALLATION INSTRUCTIONS NeoSol DS LED Horticulture Fixture

Concert Breeze s Manual

6 Assembling the Blades

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instructions Part No

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

IMpORTANT SAFETy INSTRUcTIONS

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

Owner s Guide and Installation Manual

ATKINSON DYNAMICS SPEAKERS

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

USER S INFORMATION MANUAL

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

LED ROUND MINI PANELS

ELSTON 52 CEILING FAN

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

OPERATION INSTRUCTION

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Important Safety Instructions. Important Safety Instructions

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Square D Clipsal Outdoor Light-Level Sensor

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

10QT AND 6QT BACKPACK VACUUMS

Cold Deck Canopy and Shelf Lights and Retrofit Kit

SCENE 2x2 INSTALLATION INSTRUCTIONS. Recessed T-Bar GENERAL SAFETY INSTRUCTIONS: NOTE:

Portion Bag Cheese Warmer

CONTENT. Precautions to Avoid Possible Exposure to Excessive Microwave Energy.. Important Safeguards... Control Panel...

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Owner s Guide and Installation Manual


ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

LED Seamless VaporProof Fixture Installation Instruction

ITEM # SAIL STREAM CEILING FAN MODEL #41695

Menumaster. Commercial Microwave Oven Owner's Manual GCSAND7RR

EcoBrite Smooth Light LED Light Fixtures

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Honeywell Durafit LED Retrofit Kit

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

Dioluce Products Installation Instructions

HPNLS-LO. Installation Manual

OWNER S MANUAL MODEL BW4B SLICER WARMER

Installation Instructions

Adjustable Electric Heater

LED Flat Panel Retrofit

Transcription:

Installation Instructions Clean Room Troffer Grid & Sheet Rock Installation, Maintenance Revision 00 I-SRTL Revision Date 8/14/2017

LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels. Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. Installation and service of luminaires should be performed by a qualified licensed electrician. Maintenance of the luminaires should be performed by person(s) familiar with the luminaires construction and operation and any hazards involved. Regular fixture maintenance programs are recommended. It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary. DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes, this matter should be referred to Acuity Brands Lighting, Inc. WARNING RISK OF ELECTRIC SHOCK Disconnect or turn off power before installation or servicing. Verify that supply voltage is correct by comparing it with the luminaire label information. Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. All wiring connections should be capped with UL approved recognized wire connectors. WARNING RISK OF BURN Allow lamp/fixture to cool before handling. Do not touch enclosure or light source. Do not exceed maximum wattage marked on luminaire label. Follow all manufacturer s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. CAUTION RISK OF INJURY Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. Avoid direct eye exposure to the light source while it is on. CAUTION RISK OF FIRE Keep combustible and other materials that can burn, away from lamp/lens. Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. Page 1 of 8

LED IMPORTANT SAFETY INSTRUCTIONS CAUTION: RISK OF PRODUCT DAMAGE Never connect components under load. Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation. Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched circuit. Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling. Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature. Only use fixture in its intended location. LED products are Polarity Sensitive. Ensure proper Polarity before installation. Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit. Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance. Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance. Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings. Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements. Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty. Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls Daylighting Gotham American Electric Lighting DARK TO LIGHT SunOptics Carandini Mark Architectural Lighting Antique Street Lamps LC&D Holophane Peerless Hydrel ROAM RELOC Renaissance Lighting Tersen Sensor Switch Light Concepts Winona Lighting Synergy Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10 Page 2 of 8

SRTL GRID MOUNTING INSTRUCTIONS WARNING: THIS LIGHT FIXTURE IS DESIGNED FOR INSTALLATION IN A T-GRID-TYPE SUSPENDED CEILING. THE FIXTURE MUST BE SUSPENDED FROM STRUCTURAL MEMBERS OF THE BUILDING ABOVE THE CEILING GRID. IT IS THE RESPONSIBILITY OF THE PERSON INSTALLING THE LIGHT FIXTURE TO ENSURE THAT THE MATERIALS, HARDWARE AND BUILDING STRUCTURAL MEMBERS THAT ARE SELECTED WILL SUPPORT THE LIGHT FIXTURE(S) AND THAT THEY MEET ALL APPLICABLE BUILDING AND SAFETY CODES. MUST be installed by qualified electrician. STEP 1 To remove the door, loosen all the screws so that they are no longer engaged into the fixture housing. Then remove the two safety cables as shown in Figure 1B. Figure 1A Figure 1B SRTL L24 & L48 STEP 2 To take out the driver covers, remove the (1) nut and (2) screws that secure them in place. Lift the driver covers out of the fixture to access the driver compartments. Figure 2A Figure 2B Page 3 of 8

SRTL GRID MOUNTING INSTRUCTIONS STEP 3 Once the driver covers are removed, access the hole and KO in the housing for wiring. After the fixture is in place in the ceiling (see Grid Installation below) use the four thru holes (Figure 3A) for actuating the swing arms. HOLES FOR SWING ARM ACCESS & SWING ARM ADJUSTMENT WIRE HOLES AND KO Figure 3A Figure 3B SRTL L48 STEP 2 Follow Step 1 above for removing the door screws. Then remove the two screws that secure the cover plates down to the LED tray. After the fixture is in place in the ceiling (see Grid Installation below) use the four thru holes (Figure 2B) for actuating the swing arms. Figure 2A Figure 2B HOLES FOR SWING ARM ACCESS & SWING ARM ADJUSTMENT Figure 2C Figure 2D Page 4 of 8

SRTL GRID MOUNTING INSTRUCTIONS Grid Installation Attach support wires to fixture through holes in swing arm provided as shown. Place fixture in 2 x 4 ceiling grid opening (for 2SRTL L24-2 x 2 grid opening, for WSTL L48-1 x 4 grid opening), maintaining adequate support for fixture. Securely attach upper ends of support wires/chains to building structural members above fixture, putting some tension in wires. Turn bolts in swing arms until swing arm is resting on grid. Before reinstalling door and covers install provided plugs in all four swing arm cutouts in corners of fixture Support Wires Swing Arm on Grid Swing Arm Plugs (Quantity 4) Page 5 of 8

SRTL SHEET ROCK MOUNTING INSTRUCTIONS Sheet Rock Installation See sheet rock cutout size chart below. Note - fixture MUST be secured to the plenum by contractor at the job site or by others. Configuration A (inches) B (inches) 1x4 10 1/2 46 1/2 2x2 22 1/2 22 1/2 2x4 22 1/2 46 1/2 Sheet Rock Cutout Table Fixture Mounting in Sheet Rock Inset Door FIXTURE MUST BE SEALED TO PLENUM BY OTHERS Flange Mount Detail Inset Door Fixture Mounting in Sheet Rock Overlap Door Flange Mount Detail Overlap Door Use Momentive RTV100 Series Silicone caulk or equivalent to seal door to sheet rock. Entire perimeter of door to be sealed by others. Page 6 of 8

SRTL MAINTENANCE INSTRUCTIONS Maintenance MUST be performed by qualified electrician. Before starting Disconnect fixture from power supply before performing any maintenance. 2SRTL L24 & L48 Accessing the LED boards To access the linear LED boards, follow instructions in Step 1 for opening the door. Note Do not remove safety cables. Accessing the LED drivers and other components To access the LED drivers, electrical components and wiring hole open the fixture door (as seen above) and remove the two screws and one nut that hold each driver cover in place (seen in 2SRTL L24 & L48 - Step 2 above). Removing end covers to access wiring of LED boards Follow steps above for removing the door and driver covers. Then remove two screws which secure the end cover. Page 7 of 8

SRTL MAINTENANCE INSTRUCTIONS SRTL L48 Removing LED tray to access drivers and other components Follow steps 1 & 2 above for opening the fixture door and removing the cover plates attached to the LED tray. Then remove (4) screws that secure the LED tray in place. CAUTION The LED tray is not secured by tether; so handle with care when removing. To fully remove the LED tray, disengage the quick disconnects that connect the LED boards to the drivers. Take note of such connections as to maintain them when closing up the fixture. Note: If performing maintenance on an overlap, flange mounted fixture requires opening the fixture door, caulking MUST be reapplied per the install instructions above in order to reestablish the seal to the plenum and maintain IP ratings. Page 8 of 8