FlowGrid for Axial and Centrifugal Fans

Similar documents
FlowGrid for Axial and Centrifugal Fans

FlowGrid for Axial and Centrifugal Fans

FlowGrid air-inlet grille for axial and centrifugal fans. Less noise more quality of life.

Low-noise fans are not a product of chance

What is the correct type of fan: Axial, radial, diagonal?

STANDARD, QUIET AND SUPER QUIET THE MODELLING OF FLOW AND THE REDUCTION OF TURBULENCES

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

Heat Recovery Air Handling Units

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

THE CONTROL METHOD OF THE INFLOW TURBU- LENCE INTERACTION NOISE FOR ROUTER COOLING FAN

TTM-01: ebm-papst fans for outdoor applications water and humidity protection

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

MECHANICAL VENTILATION

TopVent Design Handbook

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

GIVE A FAN A CHANCE Installation Dos & Don ts

ECV SP GUE ALO CAT ICAL TECHN

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

OIL-FREE ROTARY SCREW COMPRESSORS Fixed Speed Regulated Speed (RS) D75 D275 INTELLIGENT AIR TECHNOLOGY

Internationally Patented Models. CENTRIFUGAL JUICER # 50 Santos Juicer To extract the maximum quantity of fruit and vegetable juices LNE

onlinecomponents.com 144

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Technology by ebm-papst

ROOFTOP PACKAGED AIR CONDITIONERS

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Air Handling Units. T F E.

Practical Consideration of Noise from Fans

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services


Controlled mechanical ventilation GB 03

Gas-fired unit heaters for indoor installation

Easily maintained air curtain. Comfort air curtains Model DoorFlow

Ceiling air diffuser INDULTHERM INDULTHERM-e

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Colt CoolStream Adiabatic Cooling & Ventilation System

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

COOLflow 4E PRODUCT RANGE

Systemair product news - Fans NEWS

Fans: Features and Analysis

Technology by ebm-papst

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

DOMEKT. Heat Recovery Air Handling Units

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use.

AcoustiFlo Fans: Retrofit Solutions and Beyond

SINGLE-ROOM VENTILATION. for schools and public spaces

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Colt CoolStream Evaporative Cooling & Ventilation System

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

... RTU. Packaged Air to Air Heat Pump...

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

Air Box 12 Aeration System

Noise Protected Buildings

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

HIGH-PERFORMANCE FANS

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

... UDSA - UDSBD Gas fired unit heaters...

Ventilation Unit Zehnder ComfoAir 350

THERMAL MANAGEMENT. Outdoor 3.13 to

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

BRAHM. Working together for a crystal-clean production line COLLECTOR SERIES

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Energy efficiency - Multiscroll technology. Standard. Comfort Air quality and low noise level. Filtration Level. Ventilation minimum flow

Air Handling Unit Airblock FG

PYXIS U PYXIS U. rcgroupairconditioning

Evaporators 60HZ version

WIND Technical Description

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

SMOKE CONTROL - NEW DIRECTIONS

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Installation, operation and maintenance guide for window models

Specialized in the design and the tailor-made production of dryers, coolers and thermal processing equipment for industrial use.

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

TMCI Padovan Evaporators

CONTROLLED MECHANICAL VENTILATION

CASSETTE UNIT. Comfort Circle

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Ceiling air diffuser INDULTHERM INDULTHERM-e

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Air. Pressure. Motion. nnnnnnnn

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

Who we are and what we do. The story of the world s leading manufacturer of axial impellers

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

HEAT RECOVERY AIR HANDLING UNIT

PRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation

Mobile climate solutions

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

Transcription:

FlowGrid for xial and Centrifugal Fans Less noise better quality of life. The engineer s choice

Noise disturbances Cause and solution Innovating for people Situation Excess noise is the result of the inflow of air to a fan being disturbed. symmetrical inlet conditions, such as the walls of a device being at different distances from the fan, create powerful vortices. In the narrowest areas, these combine to form vortex strings. These turbulences then hit the rotating blades of the fan, generating noise specifically a broadband noise and additional narrowband, tonal frequency components, known as propeller noise or tonal noise. FlowGrid stands for... efficient noise reduction features in cooling, ventilation and air-conditioning technology. ebm-papst offers a future-oriented solution for the problem of high-performance technology generating disturbing noise: FlowGrid for axial and centrifugal fans. The grill on the air inlet side drastically reduces the noise emissions and minimizes disturbing low frequency tones. There are often problems wherever people and technology share space. The movement of air, for example, often goes hand in hand with noise. With FlowGrid, noise-generating disturbances in the fan inflow are a thing of the past! Noise spectrum The tonal noise consists of the blade-passing noise and its harmonics. The frequency of the blade-passing noise can be calculated based on the fan speed and the number of blades. The harmonics of the blade-pass ing noise are integer multiples of it. n axial fan with five blades and 1,200 rpm, for example, would result in a blade-passing noise with a frequency of 100 Hz. The respective frequency of the blade-passing noise and its harmonics result in high elevations in the sound pressure level, especially in the lowfrequency range. It is exactly this level where it is particularly difficult to reduce noise. Passive noise-reduction measures often mean large space requirements and high costs. Solution FlowGrid, the grill on the air intake side, drastically reduces the noise-generating disturbances. The vortex strings are split when hitting the grille and considerably weakened as they flow through it. This reduces the sound pressure in the entire frequency range, but particularly the disturbing low frequency tonal range. The result is a considerably lower sound pressure level and a noise which is less disturbing. This means that noise regulations can be complied with more easily and the well-being of people in the direct vicinity is not affected. Formation of air vortices due to an asymmetrical intake area. Sound pressure level L p db Blade-passing noise 100 Frequency f 200 300 400 500 600 Hz The noise spectrum is characterized by narrowband, tonal frequency components tonal noise. Whether it s heat pumps in the garden, supermarket condensers or ventilation systems on an industrial property: FlowGrid, the innovative air inlet grill from ebm-papst, uses technical expertise to provide drastic noise reduction. clear improvement: FlowGrid reduces the sound pressure level and considerably weakens tonal noise. 2 3

The sound of silence Less noise Proven by measurement results s a global player, we have to consider global issues. This also includes acting in an environmentally-conscious way. n important part of this is the reduction of noise, which plays a major role in regard to general quality of life. With FlowGrid, ebm-papst is making a clear contribution to active noise reduction. The innovative airintake grills work with both axial and centrifugal fans while not affecting their high efficiency in any way. Using them can help to reduce or entirely avoid the use of cost-intensive, passive noisereduction measures. It is no surprise then that FlowGrid has a patent pending. The measurement results detailed below show the benefits that FlowGrid can offer. Radial applications Low profile air handling unit with RadiPac Ø 250 ir purifier with RadiCal Ø 310 ir-water heat pump with RadiCal Ø 450 Central air handling unit with RadiCal Ø 630 FlowGrid for axial and centrifugal fans Reduced noise range Lower noise level Drastically reduced tonal noise Maintaining efficiency ir performance unaffected No increase in input power Quick assembly Through-holes for simple mounting Customer-specific mounting on request Effective environmental protection Noise reduction as an important part of environmentally friendly operation Ventilation and aeration of rooms, with or without heat recovery. The spaces to be air-conditioned are supplied with conditioned air via ducts. The sound is carried through the ducts into the rooms, requiring the use of additional noise-reduction measures such as acoustic insulation. Noise reduction regulations must be complied with. Furthermore, the disturbing tonal noise should be prevented from entering the rooms. Reduction of the noise level by 2.5 db() and of the blade-passing noise by 9 db. coustic insulation costs can be greatly reduced. Creating a comfortable climate through purifying the air from allergens and dust particles. The fan is installed in a housing with a filter for airborne material. The air inflow is disturbed by the filter on the intake side and by the limited installation dimensions. s the devices are mostly installed in areas where people live or spend long periods of time, reducing noise emissions plays an important role. Reduction of the noise level by 2.8 db() and of the blade-passing noise by 10 db. This leads to a comfortable climate without any disturbing operating noises. Heat is extracted from the outside air. This is used to heat the residential building via a circulatory system. The centrifugal fan is installed in a housing directly behind an evaporator. In compact heat pumps, the evaporator is placed very close to the fan. Excess noise is created by the disturbed air inflow. s they are used in residential buildings, however, noise limit values need to be complied with. Noise limit values are complied with and the blade-passing noise is reduced by 4 db. This results in less disturbing noise. Central ventilation and aeration of rooms, with or without heat recovery and outside air treatment. part from the fans, components such as filters, heat exchangers, humidifiers and de-humidifiers are installed in the device. The fans press air through the device and then through ventilation ducts. Significant turbulences at the fan inlet, due to low distances between the fan and the walls in the intake area, as well as components of the device, impede the flow of air. Reduction of the noise level by 3.3 db() and of the blade-passing noise by 9 db, reducing the need for acoustic insulation. Compact design Robust design Low space requirements Less acoustic insulation work Made from composite material vailable with flammability class UL94-5V 2.5 db() 2.8 db() 2.5 db() 4dB 3.3 db() 9 db 10 db 9 db Δ-Sound power level Δ-Blade-passing noise sound pressure level ll examples were measured under laboratory conditions. The results are dependent upon the design of the units. 4 5

The sound of silence Silence is the solution xial applications ir-water heat pump with HyBlade Ø 630 Condenser with HyBlade Ø 710 V-shaped condenser with HyBlade Ø 800 Condenser with HyBlade Ø 800 and xitop Would you like to find out more? If you need an installation guide or more information about FlowGrid dimensions in general, download the manual from this site: http://flowgrid.ebmpapst.us Heat is extracted from the outside air. This is used to heat the residential building via a circulatory system. The axial fan is installed directly behind an evaporator for horizontal or vertical air conduction. In compact heat pumps, the evaporator is placed very close to the fan. Excess noise is created by the installation position. s heat pumps are used in residential buildings, however, noise limit values need to be complied with. Noise limit values are complied with and the blade-passing noise is reduced by 12 db. Extraction of heat arising in a coolant circuit. One or multiple axial fans extract outside air through a horizontally arranged heat exchanger. The fans are placed very close to the heat exchanger. This results in the air inflow being disturbed. If multiple fans are used in one condenser, the uneven air inflow becomes stronger. Reduction of the noise level by 3.9 db() and a huge reduction of the blade-passing noise by 16 db. This results in much less disturbing noise. Extraction of heat arising in a coolant circuit. One or multiple axial fans extract outside air through a heat exchanger arranged in V-form. Due to the size of the heat exchanger, the distances between it and the fan vary greatly. This leads to turbulences being created in the intake area. Reduction of the noise level by 1.3 db() and of the blade-passing noise by 7 db. Extraction of heat arising in a coolant circuit. Outside air is sucked through a heat exchanger. The condenser, with a horizontally arranged exchanger, has an axial fan with an xitop diffuser unit installed on the pressure side. Despite an already low noise level, there is still a disturbing tonal noise. dditional reduction of the noise level by 2.8 db() and of the blade-passing noise by 12 db. Or scan the QR code here: Closed FlowGrid Solution Unlike the larger open FlowGrid grills, the smaller sizes of 190 to 250 have a complete grid cover, combining optimum air conduction with contact protection as per DIN EN ISO 13857 ("Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs"). Thus, it removes the need for an additional fan guard, which would negatively affect the intake flow. 2.7 db() 3.9 db() 1.3 db() 2.8 db() 7 db 12 db 12 db 16 db Δ-Sound power level Δ-Blade-passing noise sound pressure level ll examples were measured under laboratory conditions. The results are dependent upon the design of the units. 6 7

FlowGrid lways a good solution Notes Version Version B FlowGrid is completely enclosed and works as a fan guard. B C Section - Detail Y Y H X D 4x E S UL 94-HB Part Number UL 94-5V Part Number RadiCal RadiPac HyBlade B C D E S H 00190-2-2957* 00191-2-2957 175, 190 170 155-160 150 4.5 2.0 30 00250-2-2957* 220, 225, 250 205 193 187 4.5 2.0 38 20280-2-2957 20281-2-2957 220, 225, 250, 280 280 200 280 245-260 245 4.5 3.5 40 25310-2-2957 25311-2-2957 310 310 250 310 290 282 4.0 3.5 49 00400-2-2957 00401-2-2957 355, 400 355 365 335-345 325 4.0 3.0 56 35505-2-2957 35506-2-2957 450, 500 400, 450, 500 330, 315, 330, 350 470 440 412 9.0 3.0 71 00630-2-2957 00631-2-2957 560, 630 560, 630 400 580 545 532 10 3.0 90 50710-2-2957 50711-2-2957 710 450, 500 590 666 630 580 10 3.0 106 63000-2-2957 63001-2-2957 800 560, 630 734 785 750 724 10 3.0 125 80000-2-2957 80001-2-2957 900 710, 800 930 995 960 920 10 3.5 131 91000-2-2957 91001-2-2957 910 1035 1105 1075 1025 10 3.5 164 : Minimum installation dimension B: Outer diameter C: Pitch circle diameter D: Reference diameter for matching with the nozzle E: Hole diameter S: Thickness of mounting tabs H: Installation height X: Nozzle diameter at bent outer end *FlowGrid is completely enclosed and works as a grill guard. The reference diameter must be at least equal to the nozzle diameter at the bent outer end (D X) ll dimensions in mm 8 9

Notes Notes 10 11

www.ebmpapst.us Printed in the US - 112217-FLG ebm-papst Inc. North merica 100 Hyde Road Farmington, CT 06034 Phone + 1 860-674-1515 Fax + 1 860-674-8536 sales@us.ebmpapst.com ebm-papst Inc. 2016. ebm-papst Inc. reserves the right to change any specifications or data without notice The engineer s choice