Disposal Manual. m{zd{ 6. Capacitor( -ELOOP ) October 2012 Mazda Motor Corporation

Similar documents
1. Chemical Product and Company Identification

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Product Number:

Material Safety Data Sheet

Material Safety Data Sheet

Kent Reef Carbon Material Safety Data Sheet

Material Safety Data Sheet

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

MATERIAL SAFETY DATA SHEET

3M MATERIAL SAFETY DATA SHEET 3M(TM) Transpore(TM) Surgical Tape Cat. # 1527 series, 1527S-1, 1527S-2 04/07/2006

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET 3M Single Coated Medical Plastic Tape 1527L, 1527LX, 1527SP and 1527ENP 02/21/11

3M MATERIAL SAFETY DATA SHEET 3M(TM) Durapore(TM) Surgical Tapes Cat. #1538 and 1538S series 02/27/2006

3M MATERIAL SAFETY DATA SHEET 3M(TM) Micropore(TM) Surgical Tape 1530, 1530S, 1530B, 153NS, /03/2006

Material Safety Data Sheet

Safety Data Sheet. according to Regulation (EC) No 1907/2006 WICKES SMOOTH MASONRY

EMERGENCY PHONE: or (651) (24 hours)

PRODUCT SAFETY DATA SHEET

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking

MATERIAL SAFETY DATA SHEET 3M Micropore Surgical Tape 1530, 1530S, 1530B, 153NS, /24/12

MATERIAL SAFETY DATA SHEET 3M Durapore Surgical Tapes Cat. # L (with liner) and 1538S series 02/03/12

Z86 Safety-Plus Industrial Cleaner Concentrate

EMERGENCY PHONE: or (651) (24 hours)

43 May cause sensitisation by skin contact. 67 Vapours may cause drowsiness and dizziness.

EMERGENCY PHONE: or (651) (24 hours)

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet according to Regulation (EC) No. 1907/2006. Composition/Information on Ingredients

MATERIAL SAFETY DATA SHEET 3M Tapes: 3900, 3939, 6969, 2929, 5959, 8979, 8979N, and /19/13

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET FOR MOISTUREGUARD FOR CCA. 1.0 Introduction NZS 5433:1999.

MATERIAL SAFETY DATA SHEET 3M Earloop Fluid Resistant Face Mask Cat. # 1820, 1820FS 09/18/12

Material Safety Data Sheet

EMERGENCY PHONE: or (651) (24 hours)

Material Safety Data Sheet. acc. to ISO/DIS Printing date 01/26/2001 Reviewed on 03/28/2000

Material Safety Data Sheet Masonite TM Hardboard

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: INGREDIENTS SECTION 3: HAZARDS IDENTIFICATION

SAFETY DATA SHEET. 1. Chemical Product and Company Identification. 2. Hazards Identification. 3. Composition/Information of Ingredients CH 3

Material Safety Data Sheet

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEETS. SECTION I Manufacturer/Distributor Telephone No.: (315)

This MSDS has been compiled in accordance with - EC Directive 91/155/EC - OSHA's Hazcom Standard (29 CFR )

EMERGENCY PHONE: or (651) (24 hours)

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

MATERIAL SAFETY DATA SHEET

Radiator Additive. ZetaLube. Description

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

EMERGENCY PHONE: or (651) (24 hours)

MATERIAL SAFETY DATA SHEET

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

FRONT BUMPER COVER - VIN RANGE: H18680->H99999 (G )

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

3.1. Substances Not applicable 3.2. Mixtures Name Product identifier % GHS-CAN Classification GHS-US classification

PRODUCT SAFETY DATA SHEET

Safety Data Sheet. P.O. Box St. Louis MO Phone: Emergency telephone number: CHEMTEL GHS02 GHS04 GHS07 GHS08

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

Safety Data Sheet for use in USA Date: October 1, IDENTIFICATION OF THE PRODUCT AND OF THE COMPANY Trade name:

Material Safety Data Sheet U.S. Department of Labor Occupational Safety and Health Administration

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/26/2014 Revised On 09/26/2014

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/26/2014 Revised On 09/26/2014 HI TECH CLEAR ENGINE COATING

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/26/2014 Revised On 09/26/2014 BIG RIG NEW EQUIPMENT YELLOW

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

Resin teeth. Ivoclar Vivadent AG, Bendererstrasse 2, 9494 Schaan. Principality of Liechtenstein. Resin teeth. Anterior and Posterior Teeth

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

PARABOND DETACH II Adhesive Remover

SAFETY DATA SHEET CHUBB ABE40 DRY CHEMICAL POWDER FIRE EXTINGUISHER FLAMEGUARD R ABE DRY CHEMICAL POWDER FIRE EXTINGUISHER

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/26/2014 Revised On 09/26/2014

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

Certificate of Compliance. 1.2 ITEM NUMBER AND SIZES: ml, ml, ml, ml

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

MATERIAL SAFETY DATA SHEET

Certificate of Compliance

Industrial Descale Solutions & Descale Services

SpectraSeal 2.1 VOC Color Primer Sealer

SAFETY DATA SHEET. FILE NO.001 NAME OF PRODUCT MSDS DATE: 02/12/2016 CATCHMASTER Brand Adhesive Devices

11/22/2013. Where are we now? How did we get here? MSDS Sheets. CA MSDS Standard. Right To Know. Director s List. T8 CCR 5194 Hazard Communication

! WARNING. Style # Laguna Ventless Rectangle Fire Table Owner s Manual. Restoration Hardware Customer Service:

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

Safety Data Sheet. according to Regulation (EC) No 1907/2006. WICKES DURABLE MATT EMULSION colours

SpectraPrime Color Primer Surfacer

Safety Data Sheet. Printing date 04/15/2015 Revised On 03/12/2015

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

Safety Data Sheet. 1 Identification of the substance and manufacturer

Safety Data Sheet. acc. to OSHA HCS. Printing date 09/25/2014 Revised On 09/25/2014

Safety Data Sheet. Printing date 04/15/2015 Revised On 03/12/2015

Safety Data Sheet. Printing date 05/12/2015 Revised On 05/12/2015

Safety Data Sheet. acc. to OSHA HCS. Printing date 10/03/2014 Revised On 10/03/2014

Emergency Telephone Number Emergency Number : CHEMTREC / CANUTEC

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

MATERIAL SAFETY DATA SHEET

U.S. Department East Building, PHH 32 of Transportation. The US Department of Transportation Competent Authority for the United States

MSDS for TECH-G (PETG) taulman3d,llc St Louis, MO. taulman3d,llc

BETACURE 100 CO-REACTANT

Safety Data Sheet. Printing date 01/29/2015 Revised On 01/29/2015

Safety Data Sheet. Printing date 01/13/2017 Revised On 01/13/2017

Inclyno 2 Sieve Shaker SV020. Impact Test Equipment Ltd & User Guide. User Guide

Automatic Water System Pump SERIES

Safety Data Sheet. Printing date 12/01/2014 Revised On 12/01/2014

Extractor Installation Procedure Move the unit to the location where it is going to be installed and remove the unit from its packaging.

Paper Tape Safety Data Sheet*

Transcription:

Capacitor( -ELOOP ) Disposal Manual m{zd{ 6 Vehicle type in VIN : JM* GJ ****** 100001~ JM* GL ****** 100001~ RUM GJ ****** 100001~ October 2012 Mazda Motor Corporation 1 Capacitor disposal manual_gj_eng161128.xlsx

Contents Ⅰ.Introduction Ⅱ.Recommendation for safe disposal of capacitor Ⅲ.Precautions if visible leakage occurs from the capacitor Ⅳ.Compulsory discharge procedure of the capacitor (i - ELOOP ) Appendix 2 Capacitor disposal manual_gj_eng161128.xlsx

Ⅰ. Introduction Part of vehicles Mazda Motor Corporation produces are equipped with the capacitor for the regenerative braking system (i-eloop). Please make sure to discharge the capacitor compulsorily first time after accepting an end of life vehicle according to this manual when the vehicle with the capacitor is dismantled.! Warning If the vehicle or parts are disposed of (scrapped) with the capacitor (i-eloop) charged with electricity, the electricity stored in the capacitor could cause a short circuit during disposal. Before disposing of the vehicle or parts, always discharge the capacitor. Ignition generated by a shorted current may ignite flammable objects The wiring harness temperature increases by the shorted current while it is disconnected and cause severe burns and serious injury if the wiring harness is touched Touching the wiring harness while your body is wet with the wiring harness disconnected may result in electrical shock If the terminal of one of the following i-eloop-related parts contacts the vehicle body while the service plug of the capacitor (i-eloop) is installed, it could cause a fire and damage to electrical parts. When disconnecting the following terminals, always remove the service plug of the capacitor (i-eloop) before disconnecting. Battery cable terminal of capacitor (i-eloop) Engine wiring harness terminal of capacitor (i-eloop) Battery cable terminal of DC-DC converter (i-eloop) Generator terminal B 3 Capacitor disposal manual_gj_eng161128.xlsx

Ⅱ. Recommendation for safe disposal of capacitor 1. Deformation, cracks, power leakage, an electrolyte leakage may occur with the capacitor if the vehicle is involved in an accident. This could result in fire, smoke, and electrocution due to a short circuit. When performing a compulsory discharge on such a vehicle, or if the capacitor cannot be compulsory discharged due to an accident, consult an Authorized Mazda Dealer. 2. Disconnect the negative battery cable before performing a compulsory discharge of the capacitor Performing the discharge procedure without disconnecting the negative battery cable may cause fire and smoke. 3. Always remove the service plug before performing a compulsory discharge of the capacitor If the terminal of one of the i-eloop-related parts contacts the vehicle body while the service plug of the capacitor is installed, it could cause a fire and damage to electrical parts. 4. The electrolyte capsulated inside capacitor is an organic solvent containing an organic boron compound. The capacitor contains 1000 ml of the solvent. If visible leakage from the capacitor occurs, refer to "Precautions if visible leakage occurs from the capacitor" 5. After discharging the capacitor, do not throw it into a fire or allow it to come close to heat, or become heated. 6. If the capacitor itself is to be disposed of Dispose of the capacitor in accordance with your local laws and regulations. Please refer to the appendix for your information. Usually removing a capacitor from a vehicle is not necessary when the vehicle is disposed of. 7. Do not neglect, divert, modify, or disassemble the capacitor Accidents and injury could occur as a result of touching an improperly disposed of capacitor. Fire, smoke, and electrolyte leakage may occur if a capacitor is disassembled or modified, or it is diverted or reused on vehicles other than the i-eloop equipped vehicle, or used for other purposes. Mazda Motor Corporation assumes no responsibility whatsoever for any accidents or loss caused by re-appropriation, modification, or disassembly of a used capacitor, or any accident or loss caused by neglect, resale, or transfer of the capacitor. Business operators conducting such activities hold responsibility. 4 Capacitor disposal manual_gj_eng161128.xlsx

8. If fire occurs near a capacitor Use dry chemicals for a small fire. Use alcohol-resistant foam, water spray, or mist for large fires. Stay upwind and extinguish the fire wearing a respirator for protection from smoke and combustion by-product inhalation. 5 Capacitor disposal manual_gj_eng161128.xlsx

Ⅲ. Precautions if visible leakage occurs from the capacitor Avoid inhalation of the material, and avoid contact with eyes, skin, and clothing. Wash hands and face sufficiently after handling. Keep the capacitor away from flames or sources of heat. Wear protective gear such as rubber gloves, protective goggles, and a gas mask. Dilute the liquid with water and wipe it off Properly dispose of the waste cloth used for wiping the liquid as industrial waste. Skin contact Wash the skin immediately with plenty of water or hot, soapy water for at least 15 minutes. Obtain medical attention if skin irritation occurs. Remove contaminated clothing immediately. Eye contact Immediately wash eyes with plenty of water for at least 15 minutes and obtain medical attention. Inhalation Immediately move anyone exposed to contamination to an area with fresh air. Keep the victim warm and quiet and obtain medical attention. Ingestion Have the person drink a glass of water or milk. Obtain medical attention immediately. 6 Capacitor disposal manual_gj_eng161128.xlsx

Ⅳ. Compulsory discharge procedure of the capacitor ( i - ELOOP ) Location of the capacitor This caution label is attached here. Capacitor Capacitor (i-eloop) compulsory discharge 1. Disconnect the negative battery cable. When disconnecting the plastic deformed negative battery cable, expand the gap of the negative battery terminal using a flathead screwdriver, and remove the nut. Note The negative battery cable nut cannot be removed to prevent it from falling off. 7 Capacitor disposal manual_gj_eng161128.xlsx

2. Turn the steering wheel completely to the right. 3. Remove the 3 fasteners for the front mud guard (LH) shown in the figure. FRONT MUD FASTENER FRONT 4. Set the front mud guard (LH) aside as shown in the figure. FRONT MUD GUARD(LH) FRONT 5. Set aside the relay box shown in the figure to provide access to the service plug. 8 Capacitor disposal manual_gj_eng161128.xlsx

6. Remove the service plug installation bolt shown in the figure. 7. Pull the service plug in the direction of the arrow shown in the figure. Note The service plug cannot be completely removed. 8. Using the removed installation bolt, fix the service plug at the position to which it was pulled out. 9. Remove the discharge box cover. 9 Capacitor disposal manual_gj_eng161128.xlsx

10. Connect the connector in the discharge box to the plug as shown below. 11. Verify that the LED which displays during discharging is illuminated. Caution Do not touch the discharge box because the inside of the box becomes hot during discharging. Note The LED turns off when the discharge is completed. Completion of discharge takes a maximum of approx. 2 hours. 12. Verify that the LED turns off. Caution Do not return the service plug to the original position even after discharging is finished. 13. Dispose of the vehicle or the parts in accordance with your local laws and regulations. 10 Capacitor disposal manual_gj_eng161128.xlsx

Appendix PRODUCT SPECIFICATION 1. IDENTIFICATION CAPACITOR 2. COMPOSITION INFORMATION HAZARDOUS INGREDIENTS % CAS NUMBER Exterior Electrode Electrolyte Exterior Iron Aluminium Organic electrolyte solution primarily containing carbonate ester Synthetic Resin (PP,PBT) 28% or less 17% or less 17% or less 6% or less 3. HAZARDS IDENTIFICATION NFPA/HMIS RATING (0=minimal, 1=slight, 2=moderate, 3=serious, 4=severe) Iron Aluminium Organic electrolyte solution primarily containing carbonate ester Synthetic Resin (PP,PBT) Health=0, Fire=0, Reactivity=0 Health=0, Fire=0, Reactivity=0 Health=1, Fire=1, Reactivity=0 Health=1, Fire=1, Reactivity=0 GENERAL SAFETY CONSIDERATIONS Cells inside the product may vent/rupture if overcharged, reverse charged, incinerated or heated to abnormally high temperature. Do not crush, mutilate, nail penetrate or disassemble the product. High case temperature may result from charge-discharge of the product. 4. FIRST AID MEASURES If the outer casing of the cell is damaged, and exposure to internal electrolyte within the product occurs, the following actions are recommended. INHALATION Move to the area with fresh air, then keep rest at quiet and warm condition. Seek medical attention. EYE CONTACT Immediately flush the eyes sufficiently with water for 15 minutes, and have immediate medical treatment. SKIN CONTACT Immediately wash it down with a large quantity of water, and thoroughly wash the skin with soap. If there is a fear of burn, have immediate medical treatment. INGESTION Drink milk/water and induce vomiting; seek medical attention. 1/4 page Capacitor disposal manual_gj_eng161128.xlsx

5. FIRE FIGHTING MEASURES FIRE AND EXPLOSION HAZARDS. High temperature can generate flammable vapor. When mixed with air and exposed to ignition source, vapors can burn in open or explode if confined. Vapors may be heavier than air. EXTINGUISHING MEDIA Dry chemical, carbon dioxide, dry sand FIRE FIGHTING Move the product from fire area if it can be done without risk. Avoid inhalation of material or combustion by-products. Stay up wind and keep out of low areas. Wear adequate personal protective equipment. 6. ACCIDENTAL RELEASE MEASURES 7. HANDLING AND STORAGE HANDLING Avoid exposing to fire. Do not short-circuit the terminal with it charged. Do not install or disinstall the product while it is charged. Wear protect equipment such as protect glasses or gloves. STORAGE Store the product under the environment which is free from high temperature, high humidity, rain, dew, or sunlight. Store the product under the environment without a risk of toxic gas, droplet, dust generation/invasion or submergence. Store the product under the environment which is free from fire. Avoid rapid temperature change as it leads to dew condensation or degradation of the product. Store the product upward to prevent liquid leakage. Store the product with it terminals short-circuited after discharge. 8. EXPOSURE CONTROLS/PERSOL PROTECTION EXPOSURE CONTROL Keep the regulations for export since electrolyte may leak in case the product is turned, fallen or given a strong impact. Please connect it to specified devices only. PERSOL PROTECTION (Respirator) (Eye/face protection) (Gloves) (Foot protection) Not required during normal operations. Not required beyond safety practices of employer. Gloves recommended to handle the product. Steel-toed shoes recommended. 2/4 page Capacitor disposal manual_gj_eng161128.xlsx

9. PHYSICAL AND CHEMICAL PROPERTIES State: Odor: ph: Vapor pressure: Vapor density: Boiling point: Solubility in water: Except electrolyte insoluble Electrolyte soluble Solid 10. STABILITY AND REACTIVITY REACTIVITY None INCOMPATIBILITIES None during normal operation. Avoid exposure to heat, open flame and corrosive. HAZARDOUS DECOMPOSITION PRODUCTS None during normal conditions. CONDITIONS TO AVOID Avoid exposure to heat and open flame. 11. TOXICOLOGICAL INFORMATION This product is not toxic during routine handling and use. Sensitization: Teratogenicity: Reproductive Toxicity: Acute Toxicity: NO NO NO NO 12. ECOLOGICAL INFORMATION Under normal conditions, the product poses no risk to persons or the surrounding environment. 13. DISPOSAL CONSIDERATIONS Discharge the electricity to safety voltage before disposal. The product shall be treated in accordance with relative national law and regulations. 14. TRANSPORT INFORMATION Handle with care so that no electrolyte leak occurs by overturning or dropping the product. Be careful not to drop as it is a heavy device. Fumigation process may be required for export in some countries. Some types of fumigation process which uses halogenated ions may cause corrosion. 3/4 page Capacitor disposal manual_gj_eng161128.xlsx

15. APPLICABLE LAWS AND REGULATIONS HAZARDOUS MATERIALS STORAGE AND AIR TRANSPORTATION REGULATIONS UN Number It can be shipped as regular cargo as it complies IATA Dangerous Goods Regulation, Special Provision A186. HAZARDOUS MATERIALS STORAGE AND SHIP TRANSPORTATION REGULATIONS UN Number It can be shipped as regular cargo as it complies Special Provision 361. 16. OTHER INFORMATION : Not Applicable 4/4 page Capacitor disposal manual_gj_eng161128.xlsx