Air Replacement Systems

Similar documents
Air Replacement Systems

GLOBAL FINISHING SOLUTIONS

Direct Fired Heater Model AD Specification

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Truck Refinish & Large Equipment

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

GLOBAL FINISHING SOLUTIONS AUTO REFINISH. Product Catalog. The World Leader in Paint Booth Technology.

Direct Gas-Fired Make-Up Air

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Indirect Gas-Fired Make-Up Air

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio

FT900 FLIGHT-TYPE DISHWASHER

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Directflow SBDR/SBD SERIES

Make-Up Air Systems. Performance. Model DGK, DG, DGX

FT900BD FLIGHT-TYPE DISHWASHER

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

INDIRECT GAS-FIRED AIR HEATER

LARGE CAPACITY HEATERS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Modular Supply Make-Up Air Unit

FAS Fresh Air Supply Units

Field Start-Up Sheet Direct Fired Gas Equipment

FT900S FLIGHT-TYPE DISHWASHER

Directflow SBDR/SBD SERIES

SAFETY AND INSTALLATION MANUAL MODEL 8100

V-Line. Nozzle-mix line burner

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Design Specifications for Panda 900A Car Spray Booth

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

FT900S FLIGHT-TYPE DISHWASHER

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Direct Gas-Fired Make-Up Air Models DG and DGX

"NP" & "RG" AIRFLO. In-duct firing line burner

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

Infiniti Tankless Water Heater Series Featuring SRT (Scale Reduction Technology) The Infiniti Tankless Exclusive Technologies and Features

Equipment Specifications

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

AUTO REFINISH PRODUCT CATALOG GLOBALFINISHING.COM

Installation & Operation Guide Industrial Non Re-circulating Direct-Fired Heaters Horizontal / Vertical and Single / Twin Blowers

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

KIC Air Curtains. Technical Guide

REQUIREMENTS FOR HOOD PLANS

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

TIO THE LEADER SPRAY BOOTH APPLICATIONS

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Contents INDEX. TDM Series Indirect Fired Heaters

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Front Load Washer FAFW3801L W

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

TYPICAL CPA SPECIFICATIONS

The H Series. Pure and Simple Solutions. HTLV Space Heating

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Outstanding Performance; Application Flexibility

BANANZA. B-Series Direct-Fired Heating, Cooling And Pressurization Systems. Equipment Specifications

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

iq251, Gen II Submittal Data

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Capture Waste Heat with Ultra-High Efficiency

Installation & Operation Guide

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

K-400 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Power Flame Incorporated

Modular Heating & Ventilating Unit Model IGX-HV

Utility and Centrifugal

Exhaust Duct Design Page 1 of (C)

Energy saving and better heat control.

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

Duo-Aire. VAC-1 Vertical Air Curtain Wall Hood Single Plenum

VENTILATION, HEATING AND AIR CONDITIONING*

VO-ll & VO-76 VARIABLE ORIFICE DESUPERHEATER

Inspection Checklist Mechanical Rough in

DES CHAMPS PRODUCTS 85% 4,400 CFM

Transcription:

GLOL FINISHING SOLUTIONS ir Replacement Systems > Eliminate problems with drafts, stale or contaminated air, and temperature stratification > reate balanced building pressure and maintain proper comfort levels > Introduce make-up air to improve indoor air quality > 0% fresh air > 80/20 or variable recirculating airflow > ooling and humidity control available > uring/bake systems GFS direct gas fired ir Replacement Units provide an economical source of replacement air and are furnished with heater, filters, motor and blower, controls, mounting hardware and auxiliary equipment. hoice of mounting arrangement; Horizontal or, Indoor or Outdoor, Platform or eiling suspended. (800)848-8738 www.globalfinishing.com

1 ir Replacement Systems How ir Replacement Systems Work ir replacement systems replace contaminated air exhausted from industrial and commercial buildings or spray booths, with fresh, heated outdoor air, maintaining a constant leaving-air temperature regardless of the incoming, outdoor-air temperature. ir replacement systems replenish equal amounts of fresh air for every cubic foot of air exhausted. direct-fired burner with a turndown ratio of 30:1 that is 0% efficient - all the heat goes directly into the airstream. The high turndown capability allows the flame to adjust to wide, outdoor-air temperature swings throughout heating season. For example, a unit with a maximum temperature rise of 90 in the winter can adjust down to as little as a 3 temperature rise for milder spring and fall weather rossdraft ooth During Spray ooth Operations spray booth s exhaust system is removing significant quantities of shop or plant air. typical x 8 x 6 spray booth may exhaust more than 8,000 cubic feet of air per minute. If replacement air is pulled directly from outside, this volume may be sufficient to cool the interior of the building and may adversely affect the quality of coatings. n air replacement system may be required, using an air replacement unit which supplies conditioned and filtered air to the booth, minimizing temperature variations and removing particulates that compromise finish quality. Downdraft ooth In the case of pressurized spray booths, air replacement is introduced directly into the spray booth, eliminating the need for air to be drawn from the facility. This allows for greater control over the temperature and filtration quality in both the facility and the spray booth environment, therefore improving working conditions and lowering overall operating costs. Recirculating ure ooth (80/20) 80% Recirc. ure ycle 20% Exhaust ure ycle Global Finishing Solutions

2 Sizing and Location UNIT LOTION The unit location requires consideration of the, Intake fresh air intake, unit size, proximity of the unit s air to the spray booth, access for installation and service. Determine the best location, unit arrangement, heat type, and the type of. TEMPERTURE RISE The temperature rise is the air temperature from the unit, above the ambient outside air temperature. n example would be; the facility is located in an area where the winter low temperature may be F, desired temperature is 70 F, therefore a unit with a 90 degree rise would provide 80 degree process air with F outside air. Unit rrangement > Horizontal or > Indoor or Outdoor Heating Types: > Natural Gas or Propane > Steam > Hot Water > Indirect Fired > Electric Heated Discharge Type: > Horizontal: End, ottom or Top > : Side or Top URING/KE SYSTEMS Variable Speed Unit: The air replacement unit is designed with a variable speed drive/motor and damper package to either 140 F or 160 F air for accelerated curing cycle. This design reduces airflow 50% during the curing mode. This system always uses outside air during the cure mode to ensure good clean air for the cure cycle. This system also includes an auto-balance system with a variable frequency drive to automatically adjust the airflow of the exhaust fan(s), to ensure proper booth balance, not only during the curing mode but during the painting mode as well. Recirculating Unit: The air replacement unit is designed with a variable speed drive/motor and damper package to either 140 F or 160 F air for accelerated curing cycle. This design recirculates up to 80% of the air while exhausting 20% to atmosphere. This design provides further energy efficiency through the recirculation of heated air, requiring less for the heating unit. This system also includes an auto-balance system with a variable frequency drive to automatically adjust the airflow of the exhaust fan(s), to ensure proper booth balance, not only during the curing mode but during the painting mode as well. 1 asing 2 urner Profile 3 urner 4 lower 5 urner Observation Port 6 Lifting Lugs 7 Motor 8 Gas onnection 9 Main Fused Disconnect Manifold ontrols Vestibule 11 Electrical ontrols Vestibule (800)848-8738

3 onfigurations onstant Volume System (0% Replacement) The constant volume system provides a consistent rate of supply air to the facility. The Direct-Fired air system heater warms the fresh air on intake, eliminating energy losses associated with alternative heat sources. In most applications, the intake air is of slightly higher volume than the exhausted air, resulting in a positive building pressure for best results. However, these units can be adjusted to intake less volume than the exhaust for applications requiring a negative building pressure. Variable ir Volume System When air replacement requirements fluctuate and onstant-volume or Two-Speed systems are not suitable, a Variable ir Volume System is the solution. y integrating a Variable Frequency Drive into the motor system, automatic adjustments can be made to the system during operation to compensate for changing conditions. Several options are available to control these adjustments: a) Potentiometer can be used to manually adjust FM b) Pre-set FM levels can be programmed and manually selected c) pressure control device can be added to automatically adjust FM relative to building pressure. The VFD allows for much lower energy costs due to smooth motor start-up and the elimination of power spikes. Integrated safety features have been added to ensure safe burner operation. 80/20 Systems For those operations requiring recirculating capability, an 80/20 system can provide energy-efficient make-up air and heating functions. y drawing at least 20% outside air, and up to 80% re-circulated air from the building, the 80/20 system reduces the energy needed for heating. The ratio of newto-re-circulated air varies according to the requirements of the building environment. utomatic sensors and pressure monitors continually adjust to maintain the most consistent working environment, the most efficient operation and lowest operating cost. These units can be configured as a fully functional building heat unit, a supplementary air make-up unit, or as a combination of both. SMPLE ONFIGURTIONS uilding Wall The following illustrations are for example purposes ONLY, contact GFS for the air replacement configuration that fits your needs. F Direct Fired Unit Intake Filter Section Mounting Stand Duct Work Supply ir uilding Wall Intake Fan or ttach to ir Replacement System 0% Fresh ir Outdoor Unit Unit Type - V1 Indoor Unit Unit Type - V2 Oven 2,000 FM Exhaust Spray ooth,000 FM Exhaust Spray ooth 12,500 FM Exhaust Global Finishing Solutions

uto alancing Systems VRILE FREQUENY DRIVES (VFD) VFD PPLITIONS 4 Features: > utomatically adjust fan motor speeds based on actual airflow conditions and maintains an air balance within a paint spray booth that keeps paint fumes from escaping and preventing dust from entering. > Provides constant air pressure and consistent exhaust airflow for spray booths to operate at their optimum rate and efficiency. > Provides a consistency of controlled temperature. enefits: > Greatly improved process control > Increases transfer efficiency > ontrols and directs overspray into filtration systems > ontrols and exhausts VOs from the work place > Extends dry filter usage up to 50% > Decreases energy cost up to 40% as compared to damper systems > Provides a cleaner system and paint finishes Horizontal Unit Outdoor - Roof Mounted Unit Type H2 Supply ir Spray ooth 15,000 FM Exhaust Duct Work Intake Hood 0% Fresh ir Horizontal Unit Indoor - eiling Mounted (Roof or Wall Vented) Unit Type H2 Suspending Rods Direct Fired ir Replacement Systems Designed to provide greater energy savings and efficiency when variable air volumes are needed for multiple stations such as manual applications to automatic electrostatic. uto-alance System Designed to automatically keep the paint booth balanced when in operation. It is recommended by GFS on all pressurized booths. This systems consists of a variable frequency drive that controls the exhaust fan motor, differential pressure gauge and sensing probes. The system monitors the interior booth pressure and will adjust the exhaust fan RPM s to what is needed for the volume of exhaust air based on what the incoming intake air is. The result is a booth that is balanced automatically and will stay in balance as the filters load up with paint over spray. System will increase useful filter life, provide a constant airflow through the booth and the ability to control booth pressure. onsta-flow System Designed to automatically adjust the exhaust fan to the changing conditions of the exhaust filters. This system is recommended by GFS on all paint booths with conveyor openings and/ or booths with multiple filter stages that have high static pressure when loading. This system consists of a variable frequency drive that controls the exhaust fan motor, differential pressure gauge and sensing probes. The system monitors the static pressure and will adjust the exhaust fans RPM s to what is needed for the volume of exhaust air based on how loaded the filter are. The result is a booth with constant air flow as the filters load up with paint and will increase filter life. (800)848-8738

5 ir Replacement Heaters Horizontal Units Model Unit Dimensions Single lower Heaters RM-12 70 46 38 RM-15 70 46 38 Side View Top View RM-18 82 60 54 RM-20 82 60 54 RM-22 0 79 58 RM-25 0 79 58 Twin lower Heaters RM-27 0 88 66 RM-30 0 88 66 Side View Top View RM-33 112 98 76 RM-36 112 98 76 RM-222* 0 146 58 RM-225* 0 146 58 RM-227* 0 156 66 RM-230* 0 156 66 RM-233* 126 184 76 Identify ir Flow Discharge for Maximum Product Performance Horizontal right-hand Horizontal right-hand bottom Horizontal right-hand top Horizontal left-hand Horizontal left-hand bottom Horizontal left-hand top H1 H2 H3 H4 H5 H6 Units Unit Dimensions Model F-12 70 50 36 Single lower Heaters F-15 70 50 36 F-18 82 65 50 Side View Top View F-20 82 65 50 F-22 0 80 50 F-25 0 80 50 F-27 1 88 60 F-30 1 88 60 Twin lower Heaters F-33 128 112 70 F-36 128 112 70 Side View Top View F-222* 0 146 50 F-225* 0 146 50 F-227* 1 156 60 F-230* 1 156 60 F-233* 128 191 70 * indicates twin blowers Identify ir Flow Discharge for Maximum Product Performance top right-hand V1 V2 V3 left-hand Global Finishing Solutions

6 omponents Duct Work 1 Straight Discharge 2 90 Horizontal Discharge Turn 3 90 Discharge Turn 4 Intake Hood 5 Horizontal Intake Hood 6 Intake Roof Flange 7 Transition Duct 8 Discharge ir Diffuser 9 Full Turn Down Hood Straight Intake 11 Straight Discharge 12 90 Horizontal Intake Turn 2 3 1 3 3 2 1 D 3 5 11 14 4 13 6 13 90 Intake Turn 14 90 Discharge Turn 15 Discharge Roof Flange 11 16 Recirc. Straight Duct 17 Recirc. Elbow E 5 Insulated duct available for Straight Duct, 90 Horizontal Turns, 90 Turns, and Transition Duct, consult GFS for pricing. F 15 11 14 Qty. of ooths: 14 11 12 9 FM: Total: Growth %: H hoose a configuration ( - H) 7 G 8 16 17 16 Duct work Qty. Length Recirculating (onsult GFS for custom configurations) Maximum Energy Savings! Recirculating ooths: Dampers reduce exhaust to approximately 20%, delivering approximately 80% of the previous heated air and 20% fresh air into cabin during cure cycle. onsult GFS for recirculating cure (80/20). (800)848-8738

ir Replacement Systems STNDRD FETURES > Structural G-90 galvanized base or tube frame > Heavy gauge G-90 galvanized steel casing > Interlocked wall seam and roof panels > Weatherproof construction > Hinged service doors with flush-mount latches > Standing roof seams > Double wall doors > Single piece construction on RM up to 230 > Six options ESSORIES ND OPTIONS > Inlet hood with 2 cleanable filter with bird screen > Fresh air V-ank filter sections > Return air V-ank filter sections > External dampers > Internal dampers > Intake dampers > ir diffuser heads > mounting stand > Roof curbs > asing insulation with G-90 galvanized steel liners > Remote control panel with operating lights > Spring isolated blower and motor > Painted casing OPTIONL ONTROL PNEL: logged Filter Switch with Light: Senses air pressure drop across the filter, and is mounted in unit. When the filter becomes dirty, the switch activates a remote control panel light, indicating a required filter change. Dual-Range Selector Dial, 90-140 F, 401M: llows for two, separate temperature set points for spray and dry modes in both paint booth applications. High Temperature Option: dapts unit with special construction and controls to high temperature paint-booth and industrial-process heating applications. Low Gas-Pressure Switch: Stops unit s operation when inlet gas pressure goes below set point. Standard on FM manifolds over 2,500 MTU and on FI (IRI) manifolds over 150 MTU. Pressure Gauge 0-15#, 0-35 : Monitors supply pressure to unit, or to burner on gas manifold. Reads low gas pressures between 0 and 15 ; 35. Low-Temperature lower Shutdown with ypass Timer: Shuts blower off if temperature drops below 40 F for longer than five minutes. Osseo, WI Dallas, TX arrie, ON Monterrey, Mexico 800-848-8738 www.globalfinishing.com email: info@globalfinishing.com 2007 by Global Finishing Solutions L.L.. ll Rights Reserved Global Finishing Solutions Printed in US MU 1-30-07