TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

Similar documents
HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

standard response Fusible Link Upright sprinkler VK204 (K8.0)

micromatic standard response stainless steel sprinklers

standard response elo upright and pendent sprinklers (storage-density/area)

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

standard response fusible link sidewall sprinkler VK112 (K5.6)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

Microfast quick response Fusible element hsw sprinkler

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

TECHNICAL DATA. Page 1 of 6

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

quick response horizontal sidewall sprinkler vk360 (K8.0)

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

STANDARD/quick. Sprinkler 42o. August 8, 2011

microfast and microfasthp quick conventional sprinklers

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

TECHNICAL DATA OBSOLETE

standard response elo upright sprinkler

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

standard response/ quick response extended coverage

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

standard response large orifice dry

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

micromatic standard response Upright sprinkler VK100 (K5.6)

standard response dry horizontal sidewall sprinklers

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

microfast sr/qr extended coverage pendent sprinkler

esfr pendent sprinkler vk510 (k25.2)

microfast quick response extended coverage hsw sprinkler vk606

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

microfast quick response Pendent sprinkler VK302 (K5.6)

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

sprinkler vk538 (K11.2)

esfr pendent sprinkler vk510 (k25.2)

Standard Spray concealed horizontal sidewall sprinkler VK481

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA. Page 1 of 5

standard response dry horizontal sidewall sprinklers

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

December 14, 2015 Page 1 of 7 TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Transcription:

May 14, 2010 Sprinkler 131a 1. DESCRIPTION Viking Intermediate Level In-Rack Sprinklers consist of a water shield installed on specifically listed and/or approved frame style standard and quick response sprinklers equipped with glass bulbs or fusible elements. Refer to Approval Charts 1 and 2 on pages 131d-e for listings and approvals. They are available in both upright and pendent styles with or without sprinkler guards. Refer to Section 5. ORDERING INSTRUCTIONS. Viking Water Shields protect sprinkler heat-sensing elements from water spray discharging from sprinklers located at a higher elevation. They may be used on in-rack sprinkler systems, under grating, on pilot sprinklers for deluge systems, outdoors as a weather shield, or any other application where water shielding is required. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Classes 2005 and 2020 See the Approval Charts 1 and 2 on pages 131d-e for sprinklers listed and/or approved as Intermediate Level Sprinklers with water shields. 3. Specifications: Viking Technical Data may be found on Available since 1997. The Viking Corporation s Web site at A. Water Shield for Pre-assembled http://www.vikinggroupinc.com. Viking Upright Intermediate Level Sprinklers (See Figure 1): The Web site may include a more recent Dimensions: 2-3/4 (70 mm) diameter, edition of this Technical Data Page..0359 (.91 mm) thick. B. Model E-1 Water Shield for Upright Sprinklers equipped with Model D-1 Guards (See Figure 2 - Top): Dimensions: 4-3/8 (112 mm) diameter, 2-1/8 (54 mm), 1/2 (12.7 mm) depth,.0359 (.91 mm) thick. Available since 1998. C. Model F-1 Water Shield for Pendent Sprinklers (See Figure 3 - Top): Dimensions: 3 (75 mm) diameter,.0359 (.91 mm) thick. Available since 1998. Material Standards: Water Shields: Cold Rolled Steel UNS-G10080. Finish: Clear Chromate over Zinc Plating, or Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Upright Intermediate Level Sprinklers (without guards): Upright Intermediate Level Sprinklers shown in Figure 1 are pre-assembled with the water shields factory installed (see note below). Refer to the chart on page 131d for upright sprinklers listed and/or approved with water shields. To order a factory pre-assembled Intermediate Level Upright Sprinkler by part number, use the base part number for the sprinkler selected from the chart on page 131d. Add the suffix U after the suffixes for the desired temperature and finish (see current Viking Price Book for temperature and finish suffixes). NOTE: Sprinkler guards are NOT available for use with factory preassembled Intermediate Level Upright Sprinklers. For Upright Intermediate Level Sprinklers with guards, see paragraph below. Upright Intermediate Level Sprinklers (with Model D-1 Sprinkler Guards): For Upright Intermediate Level Sprinklers with guards (Figure 2), the special water shield must be ordered separately and installed in the field. Refer to page 131d for upright sprinklers listed and/or approved for installation with water shields. Form No. F_012498 Upright Intermediate Level Sprinkler (Factory pre-assembled only) The standard response glass bulb style sprinkler shown above is representative only. Standard response fusible link sprinklers and quick response glass bulb or fusible element style sprinklers are also available as intermediate level sprinklers. Refer to Approval Chart 1 for listings and approvals. Figure 1 Model E-1 Water Shield (Viking Part No. 10326 or Stainless Steel Part No. 14682) for Frame Style Upright Sprinklers with the Model D-1 Sprinkler Guard Order Water Shield Separately. (Field Assembly Required. See Installation Instructions.) Order Sprinkler Guard Separately or Factory Installed. (See Ordering Instructions.) Upright Intermediate Level Sprinkler (with Guard and Water Shield) The standard response sprinkler equipped with a 5 mm glass bulb shown above is representative only. Standard response fusible link sprinklers and quick response sprinklers equipped with glass bulbs or fusible elements are also available as intermediate level sprinklers. Refer to Approval Chart 1 on page 131d for listings and approvals. Figure 2 Replaces page 131a-e dated October 9, 2009. (Updated FM Approvals for Sprinklers VK110, VK206, and VK562.)

Sprinkler 131b May 14, 2010 1. Order the sprinkler using the base part number (plus appropriate suffixes for temperature and finish) for the sprinkler selected from Approval Chart 1 on page 131d (see current Viking Price Book for temperature and finish suffixes). a. To order the sprinkler guard factory installed on the upright sprinkler, add the suffix G. b. To order the Model D-1 Sprinkler Guard separately, order Part No. 10325 or Stainless Steel Part No. 12198 (see page 130a-c). 2. Order the upright Model E-1 Water Shield, Viking Part No. 10326 or Stainless Steel Part No. 14682. Pendent Intermediate Level Sprinklers: For pendent Intermediate Level Sprinklers Figure 3), the Model F-1 Water Shields and sprinklers must be ordered separately and the water shield must be installed in the field. Refer to page 131e for pendent sprinklers listed and/or approved for installation with water shields. 1. Order the sprinklers using the base part number (plus appropriate suffixes for temperature and finish) for the sprinkler selected from the chart on page 131e (see current Viking Price Book for temperature and finish suffixes). a. For optional sprinkler guards factory installed on the pendent sprinkler, add the suffix G. b. To order the optional Model D-1 Sprinkler Guard separately, order Part No. 10325 or Stainless Steel Part No. 12198 (see page 130a-c). 2. Order the Model F-1 Water Shields using the appropriate part number for the thread size required. For ½ NPT, order Part No. 10323 or Stainless Steel Part No. 14683. For 3/4 NPT, order Part No. 10324 or Stainless Steel Part No. 14684. NOTE: Water shields are for use on pendent sprinklers with or without guards. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000). Model D-1 Sprinkler Guard: Part No. 10325 or Stainless Steel Part No. 12198 (NOT for use with factory pre-assembled Upright Intermediate Level Sprinkler.) (See technical data page 130a-c.) Sprinkler Cabinet: Six-head capacity: Part No. 03985A for factory pre-assembled upright intermediate level sprinklers (available since 1977) 4. INSTALLATION Refer to the appropriate sprinkler technical data page for warnings and additional installation instructions. Then install units according to the following. Where sprinkler guards* are used, follow installation steps described on page 130a-c. (Note: sprinkler guards* may be ordered factory pre-installed). For pre-assembled Upright Intermediate Level Sprinklers* (see Figure 1): Go to steps 2 and 3 below. * Note: Sprinkler guards are NOT available for pre-assembled Upright Intermediate Level Sprinklers. For Upright Intermediate Level Sprinklers with Guards (see Figure 2): 1. Install the Model E-1 Water Shields for upright sprinklers with Model D-1 Sprinkler Guards. a-1. Position the concave surface of the water shield facing the guard. a-2. Align the x slots in the water shield with the intersecting wires at the top of the guard. a-3. Press the water shield down firmly until the shield snaps into place with the flat inside surface of the water shield resting on the top horizontal wire ring of the guard (see Figure 2). 2. Go to steps 2 and 3 below. For Pendent Intermediate Level Sprinklers (see Figure 3): 1. Install the Model F-1 Water Shields, threading the pendent sprinklers into the shields. Model F-1 Water Shield for Pendent Sprinklers For ½ NPT, order Part No. 10323 or Stainless Steel Part No. 14683. For 3/4 NPT, order Part No. 10324 or Stainless Steel Part No. 14684. Order Water Shield and Pendent Sprinkler Separately (Field Assembly Required) For Optional Sprinkler Guard, Order Guard Separately or Factory Installed (See Ordering Instructions.) Pendent Intermediate Level Sprinklers (Water Shield Installed in Field) The standard response glass bulb style sprinkler shown above is representative only. Standard response fusible link sprinklers and quick response glass bulb or fusible element style sprinklers are also available as intermediate level sprinklers. Refer to Approval Chart 2 on page 131e for listings and approvals. Figure 3 2. Apply a small amount of pipe-joint compound or tape to the external sprinklers threads only, taking care not to allow a build-up of compound in the sprinkler orifice. 3. Install the sprinkler on the piping using the special sprinkler wrench designed for the sprinkler used. DO NOT use the water shield or guard to start or thread the sprinkler into the fitting.

May 14, 2010 Sprinkler 131c IMPORTANT NOTES Sprinkler guards are NOT available for pre-assembled Upright Intermediate Level Sprinklers. For Upright Intermediate Level Sprinklers with guards (Figure 2), the special water shield must be ordered separately and installed in the field. For pendent Intermediate Level Sprinklers (Figure 3), the Model F-1 Water Shields and sprinklers must be ordered separately and the water shield must be installed in the field. Refer to the Approval Charts on pages 131d-e for sprinklers listed and/or approved for installation with water shields. WARNING: Viking products are manufactured and tested to meet the rigid requirements of the approving agency. The sprinklers are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will nullify the approval and any guarantee made by The Viking Corporation. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the appropriate sprinkler data page. Viking sprinklers are designed to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. 5. OPERATION Refer to the sprinkler techical data page for the sprinkler model used. Viking Water Shields protect sprinkler heat-sensing elements from water spray discharging from sprinklers located at a higher elevation. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Intermediate Level In-Rack Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

Sprinkler 131d May 14, 2010 Approval Chart 1 Upright Intermediate-Level Sprinklers (The following upright sprinklers may be ordered with water shields factory installed.) Standard Response, Glass Bulb Type Listings and Approvals Nominal Overall Length Sprinkler Base Sprinkler Thread Size SIN Orifice Size K-Factor Maximum (Also refer to Important (Sprinkler) Part No. 1 Style Pressure Notes on page 131c.) NPT BSP U.S. metric 2 Inches mm culus 4 FM 5 NYC 10138 VK550 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 B1 A1 -- 12986 VK550 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-3/8 60 B1 A1 -- 10141 VK560 Upright 3/4 -- Large 8.0 115.2 175 psi 2-3/8 60 B1 A1 -- 10220 VK560 Upright 1/2 -- Large 8.0 115.2 175 psi 2-7/16 62 B1 A1 -- Standard Response, Fusible Link Type 05557 VK552 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 C1 C1 -- 12973 VK552 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-3/8 60 C1 C1 -- 05514 VK562 Upright 3/4 -- Large 8.0 115.2 175 psi 2-3/8 60 C1 C1 -- Quick Response, Glass Bulb Type 06661B VK556 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 B1 B1 -- 12978 VK556 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-5/16 60 B1 B1 -- 12281 VK558 Upright 1/2 -- Standard 5.6 80.6 250 psi 2-1/4 57 B1 -- -- 06665B VK566 Upright 3/4 -- Large 8.0 115.2 175 psi 2-3/8 60 B1 B1 -- Quick Response, Fusible Element Type 12279 VK551 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-5/16 59 D1 -- -- 13976 VK567 Upright 3/4 -- Large 8.0 115.2 175 psi 2-5/16 59 D1 D1 -- Approved Temperature Ratings A - 135 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (93 C), 286 F (141 C), and 360 F (182 C) B - 135 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (93 C), and 286 F (141 C) C - 165 F (74 C), 220 F (104 C), and 286 F (141 C) D - 165 F (74 C), 205 F (96 C), and 280 F (138 C) Approved Finish 1 - Brass Footnotes 1 Base part number is shown. For complete part number, refer to Viking s current price list. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories, Inc. for use in the U.S. and Canada. 5 FM Approved for protection of occupancies described in the FM Global Loss Prevention Data Sheets (including 2-0 and 8-9) and Technical Advisory Bulletins.

May 14, 2010 Sprinkler 131e Sprinkler Base Part No. 1 SIN Sprinkler Style Approval Chart 2 Pendent Intermediate-Level Sprinklers (The following pendent sprinklers may be installed with water shields. Pendent sprinklers and water shields must be ordered separately and field assembled.) Standard Response, Glass Bulb Type Thread Size Nominal Orifice Nominal K-Factor Maximum Pressure Overall Length (Sprinkler) Listings and Approvals 3 (Also refer to Important Notes on page 131c.) NPT BSP U.S. metric 2 Inches mm culus 4 FM 5 NYC 10139 VK102 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 B1 A1 -- 12987 VK102 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 B1 A1 -- 10142 VK202 Pendent 3/4 -- Large 8.0 115.2 175 psi 2-5/16 59 B1 A1 -- Standard Response, Fusible Link Type 05508 VK110 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 C1 C1 -- 12972 VK110 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 C1 C1 -- 05516 VK206 Pendent 3/4 -- Large 8.0 115.2 175 psi 2-5/16 59 C1 C1 -- Quick Response, Glass Bulb Type 06662B VK302 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 58 B1 B1 -- 12979 VK302 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 58 B1 B1 -- 12282 VK317 Pendent 1/2 -- Standard 5.6 80.6 250 psi 2-1/4 58 B1 -- -- 06666B VK352 Pendent 3/4 -- Large 8.0 115.2 175 psi 2-3/8 60 B1 B1 -- Quick Response, Fusible Element Type 12275 VK303 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 58 D1 -- -- 13975 VK353 Pendent 3/4 -- Large 8.0 115.2 175 psi 2-3/8 60 -- D1 -- Approved Temperature Ratings A - 135 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (93 C), 286 F (141 C), and 360 F (182 C) B - 135 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (93 C), and 286 F (141 C) C - 165 F (74 C), 220 F (104 C), and 286 F (141 C) D - 165 F (74 C), 205 F (96 C), and 280 F (138 C) Approved Finish 1 - Brass Footnotes 1 Base part number is shown. For complete part number, refer to Viking s current price list. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories, Inc. for use in the U.S. and Canada. 5 FM Approved for protection of occupancies described in the FM Global Loss Prevention Data Sheets (including 2-0 and 8-9) and Technical Advisory Bulletins.

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_012498 Replaces page 131a-e dated October 9, 2009. (Updated FM Approvals for Sprinklers VK110, VK206, and VK562.)