Worcester Controls PS/PM Series UltraSwitch. Switchbox

Similar documents
Automax PS/PM Series UltraSwitch. Switchbox

Automax XCL Series UltraSwitch. Switch box

PT700. Product Information

EP5 Electropneumatic positioner

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

D3 Digital Positioner. Product Information

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Limitorque FR Shells Removable Intumescent Fireproof Coatings

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Genie Heated Regulator Installation & Operation Instructions

Valve Position Indicator VPX Series Issue E. Datasheet

Valtek Guardian II Metal Bellows Seal Valtek Guardian II

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Rosemount 3100 Series Ultrasonic Level Transmitters

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Model 144H. Product Data Sheet , Rev DB February Content

Limit Switch Box YT-870/875 SERIES

MICRO SWITCH BX/BX2 Series

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Model 144H. Product Data Sheet , Rev DB February Content

Temperature Measurement Transmitters for field mounting

D3 Digital Positioner. Product Information

Ar-Mite TM Low Flow Armored Flowmeter

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Rosemount 3100 Series Ultrasonic Level Transmitters

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Logix Positioner Overview July 2015 Barrancabermeja. Ruben Izarra

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Level gauges Series LS Level indicator, switch and transmitter for liquids

1510 Side Mounted Level Switch

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

Dräger Polytron 7000 Fixed gas detector

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Performance Data. curus Component Recognized; File No. E IP 20

Rosemount 752 Fieldbus Remote Indicator

MBCE-110/230FR Flame Sensor Module

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Rosemount 2090P Pulp and Paper Pressure Transmitter

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Dräger Flame 2500 Flame Detection

INSTRUCTION & SERVICE MANUAL

Technical Data. Dimensions

Dräger Polytron 8000 Stationary gas detector (EC)

Level Measurement Continuous level measurement Ultrasonic transmitters

Rosemount 3490 Series

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Technical Data. Dimensions

Figure 1 DirectLine DL423 Sensor. Description, continued

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Ramsey Motion Monitoring Systems

Dräger Polytron 8100 EC Detection of toxic gases and vapors

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Guide for hazardous areas

Certificate of Compliance

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

MT3750C Series. Metal Tube Variable Area Flowmeters. Overview. Product Description. Features. Variable Area

DB1 Range - HORNS - Up to 103 db(a)

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Description. Applications

official distributor of Newson Gale Ltd.

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Ultrasonic Switches. Features & Benefits

Rosemount 2090F Hygienic Pressure Transmitter

Ultrasonic Point Level Switches

Quick Start Manual July pointek CLS100

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

MT3809G Series. Data Sheet. Metal Tube Variable Area Flowmeters. Overview. Product Description. Variable Area

Technical Data. Dimensions

Dräger Flame 2100 Flame Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Electronic Pressure Digest. Pressure and Temperature Transmitters

Condumax CLS16 and CLS16D

Fixed Gas Detection System/Meridian CERTIFICATION

The SharpEye 40/40I (IR3) Flame Detection

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Certificate of Compliance

DETECT-A-FIRE Heat Detectors

Annubar Flowmeter Series

Transcription:

TM Worcester Controls PS/PM Series UltraSwitch Switchbox

Simple Reliable Rugged The PS/PM Series UltraSwitch TM provides accurate and reliable position signaling in harsh corrosive environments. The engineered resin enclosure is provided with multiple switch options. An UltraDome TM indicator for visual position indication is standard with optional flat top for lower profile. It is designed to be directly and easily mounted onto actuators for both rotary and linear indication. It may also be used as a junction box for direct connection of solenoid valves. With a housing of high strength and corrosion resistant fiberglass-reinforced engineered resin, Nylon PA6/PA66, and pre-wired switches, it is both easy to install and withstands the toughest corrosive environments. Nylon PA6/PA66 is used in a number of different high strength, abrasion and impact resistant thermoplastic polyamide formulations. It offers excellent chemical resistance to common chemicals such as solvents, bases and salts. Designed to meet IP66/NEMA 4/4X standards, the PS/PM UltraSwitch TM is certified for both Intrinsically Safe and Non-Incendive hazardous locations. Typical applications / Industries suitable for the PS/PM-Series UltraSwitch TM are: Chemical & Petrochemical Food & Beverage Municipal & Wastewater Pharmaceutical Power Approvals Approvals for ATEX, IEC, FM and CSA hazardous locations, intrinsically safe and non-incendive. Features Switches available in a wide range of options Tool-free Quick-Set TM cams Housing of PA6/PA66 Nylon. 25-33% Fiberglass-reinforced engineered resin Easily accessed pre-wired terminal strip provided with extra terminals for solenoid valve Temp. range -40 F 180 F -40 C 80 C Conduit entries (3x) ¾ NPT Conduit Entries or (3x) M25x1,5 Conduit Entries

PS/PM-Series UltraSwitch Nomenclature Mounted on rotary actuator Mounted on linear actuator A. Manufacturer W Worcester Controls B. Shaft N NAMUR VDI/VDE 3845 D Double D 1/4 C. Connections (cable entry) PS Engineered Resin Housing 1/2 NPT PM Engineered Resin Housing M20x1,5 PN Engineered Resin Housing 3/4 NPT PG Engineered Resin Housing M25x1,5 D. Number of cable entries 1 1 conduit 2 2 conduits 3 3 conduits E. Indicator option 1 Flat cover without indicator U Standard UltraDome TM red/green C 90 deg 3-way UltraDome TM D 180 deg 3-way UltraDome TM E 180 deg 3-way Centre-blocked UltraDome TM F 120 deg Thru/Divert UltraDome TM H Black/Yellow UltraDome TM K Ektar UltraDome TM (red/green) R Reverse UltraDome TM (red=open / green=closed) X 180 deg 3-way UltraDome TM (white/blue) F. Switch quantity 0 No Switches 2 2 Switches 4 4 Switches G. Switch options options See page with switch options H. Certificate * 14 General Purpose 15 ATEX II 1G Ex ia IIC T4/T5/T6 21 IEC Ex ia IIC T4/T5/T6 22 ATEX II 2 G Ex e mb IIC T5/T6 27 FM IS Cl. l Div. 1 Grp. A, B, C, D; T4 28 FM NI, CSA NI Cl. l Div. 2 Grp. A, B, C, D, D 40 ATEX Ex ia, FM IS, CSA IS, IEC Ex ia 60 ATEX Ex ia, FM IS, CSA IS, IEC Ex ia, FM NI, CSA NI I. Analog output 0 None T 4-20 ma transmitter D 180 deg 4-20 ma transmitter A 0-1K Ohm Potentiometer J. Wiring options 0 None 3 Brad Harrison Connectors - 7 pins 4 Weidmüller special AKZ 2,5 H Heavy Duty Terminal Block K. Minimum extra terminals 2 2 Open Terminal Locations (Standard) 4 4 Open Terminal Locations (2 SPST switches) 6 6 Open Terminal Locations (2 SPDT switches) 8 8 Open Terminal Locations (2 or 4 SPST switches) L. Special options 0 None V Viton O-rings Example W N P S U 2 P E - 2 7-0 0 2 0 * See switch option data

Switch Options Data Materials of construction Switch Options Code Cert. Data/Materials Switch Option Manufacturer Load Capacity Data SPDT Mechanical Honeywell MicroSwitch 15A @ 125/250 VAC; 0,5A @ 125 VDC; 0,25A @ 250VDC; 5A @ 120VAC Ingress protection IP 66, according to EN 60529, Type 4X SPDT Gold Mechanical Honeywell MicroSwitch 1A @ 125 VAC; 50 ma @ 24 VDC Weight 1 kg / 2,2 lbs MA 3-Position Control Honeywell MicroSwitch 15A @ 125 VAC; 0,5A @ 125 VDC; 0,25A @ 250VDC; 5A @ 120VAC Part Material M3 DPDT Mechanical Cherry 15A @ 125/250 VAC Housing/Cover MB DPDT Mechanical Licon 10A @ 125 VAC PA6/PA66 Nylon. 25-33% Fiberglass filled engineered resin MD 3-Pos. Control w/indication (DA) Licon 10A @ 125 VAC Shaft Stainless Steel MS 3-Pos. Control w/indication (SR) Licon 10A @ 125 VAC Cams/Splines Nylon Nylon Buchanan TBS Series M1 MG A, B, D, F P4 A, B, D, E, F, G SPST Proximity Aleph 0.35A @ 140 VAC; 0.25A @ 200VDC (50 W Max.) Terminal Block P5 A, B, D, E, F, G SPDT Proximity Hamlin 0.25A @ 120 VAC; 0.25A @ 28 VDC (3 W Max.) Internal Brackets Stainless Steel or Plated Steel PE A, B, D, E, F, G SPDT Sabre Proximity Flowserve 1A @ 120 VAC; 2A @ 24 VDC All Internal Fasteners Stainless Steel or Plated Steel PP C, E, G SPDT Phazer Proximity Flowserve 3A @ 120 VAC; 2A @ 24 VDC All External Fasteners Stainless Steel PT A, B, C, D, E, F, G SPST BRS Proximity Flowserve 3A @ 120 VAC; 0.5 @ 24 VDC All Molded in Fasteners Anodized Aluminum N8 A, B, D, E, F PF NJ2 V3 N NAMUR NC Sensor; 8 VDC UltraDome Polycarbonate NP A, B, D, F PF SJ3.5-N NAMUR Sensor Output; 5-25 VDC Supply Rotor Polycarbonate NQ A, B, D, F PF NJ4-12GK-N NAMUR NC Sensor; 8 VDC NR D, F PF NJ4-12GM40E1 PNP Sinking; 200 ma max. Current; 10-60 VDC Code Certificate A ATEX II 1G Ex ia IEC Ex ia NS D, G PF NJ4-12GM40E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC B C ATEX II 2 G Ex e mb NT D, G PF NJ4-12GK40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC D cfmus IS E cfmus NI F ccsaus IS G ccsaus NI N9 NW A, B, D PF NBB3-V3-Z4 NPN Sourcing; 100 ma max. Current; 5-60 VDC PF SJ3.5-SN NAMUR NC Sensor; 8 VDC More switch options available

Cover Options UltraDome Indicator Flat Top Dimensions PS/PM (mm/inch) 70 2,756" 140 5,512" 85,5 3,366" 146 5,748" 103,5 4,075" 120 / 4,724" Min. Tol. for Adjustment and Inspection 39,2 1,543" NAMUR 153,8 6,055" 224 / 8,820" Min. Tol. for Adjustment and Inspection 39,2 1,543" M25x1,5 alt. 3/4" NPT(3x) 40 1,58" 15 0,59" 26,3 1,035" 5/16"-18 UNC(4x) M6(4x) 6,35 0,250" FLATS 9,53 0,375" DOUBLE D SHAFT 6,35 0,250" 12,7 0,500" 4 0,155" FLATS 9,525 0,375" 4 0,157" 7 0,276" 25,6 0,969" NAMUR SHAFT

Flowserve Corporation Flow Control Division 1978 Foreman Drive Cookeville, Tennessee 38501 USA Phone: +931 432 4021 Fax: +931 432 5518 flowserve.com FCD WCENBR0134 April 2013 To find your local Flowserve representative: For more information about Flowserve Corporation, visit flowserve.com Hazardous Locations IECEx NEM 11.0012X Ex ia IIC T4/T5/T6 Nemko 11 ATEX1065X II 1G Ex ia IIC T4/T5/T6 ATEX II 2 G Ex e mb IIC T6 ccsaus, Class I, Div.1, Grps. A,B,C,D T4/T5 Class II, Div.1, Grps. E,F,G, Class III ccsaus, Class I, Div.2, Grps. A,B,C,D T4/T5 Class II, Div.2, Grps. E,F,G, Class III cfmus, Class I, Div.1, Grps. A,B,C,D T4/T5/T6 Class II, Div.1, Grps. E,F,G, Class III cfmus, Class I, Div.2, Grps. A,B,C,D T4/T5 Class II, Div.2, Grps. E,F,G, Class III IP66 / Type 4x Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation and Maintenance (I & M) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2013 Flowserve Corporation, Irving, Texas, USA. Flowserve and PMV are registered trademarks of Flowserve Corporation.