AMPTEC - CONTROL RELAY RELAY SPECIFICATION. Capacitor (when fitted) 4.7uF 240V 50Hz Class X2

Similar documents
Amptec. Electric flow boiler

FRONT COVER (TOP) OUTLET WARNING LABEL RED IDENT ELECTRICAL CABLE ENTRY POINTS EARTH CLAMP INSULATION SHEET TERMINAL BLOCK FLYING LEAD MAIN PCB

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

Combined electric boiler and domestic hot water store

Cistern-fed water heating

Hotflo. Unvented point of use hot water

Unvented water heating

Amptec Electric Flow Boiler Installation Instructions and User Guide

MEGAFLO HE Iss 1

Handy Dri / Hair Drier

OPEN OUTLET TAPSETS. Fitting Instructions and User Guide

HI-MAX INSTANT Indirect HIU First Fix Rail / Stand-off Kit Fitting Instructions

ELECTRIC SHOWER INSTALLATION and USER INSTRUCTIONS

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

Stored Water District Heating Interface Units. Heat Interface Units

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

2015 PRODUCT RANGE GUIDE

SMART HOT WATER SOLUTIONS PRODUCT RANGE

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

HOTFLO 10 / 15. Fitting Instructions and User Guide

Streamline. Vented point of use hot water

SUPREME 140, 155, 170

SMART HOT WATER SOLUTIONS PRODUCT RANGE

LC1350 Level Controller

Air Conditioning, refrigeration and Appliance Transformers

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Installation and User Instructions

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Fitting Instructions and User Guide

Energy Audit- Spice Powder Making. Plot 2, 1 G, Leela Infopark, Technopark, Trivandrum , Kerala, India. Tel:

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

INSTALLATION INSTRUCTIONS FOR ENTRANCE CONTROL SYSTEM MODEL GL-RO-3

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

ARM SERIES Switching Relays With Priority

BC3250. Blowdown Controller

Refrigeration System with a Capillary Tube and a Thermostat

MULTIPOINT 30 & 50 Litre

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Fitting Instructions and User Guide

Dale Power Solutions Ltd

SC-LLC-200 LEAD/LAG CONTROLLER INSTALLATION INSTRUCTIONS

Power Supply Display Module PSDM. Installation and Operation Manual

CAUTION & SYMBOL DEFINITIONS:

HRU ECO 4 User manual

CME650 SERVICE PARTS

Multipoint Technical Data

Megalife Solar Vented Cistern Fed Water Heater Installation manual

Optyma Slim Pack Condensing Units

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

BX444-Mc Gas Detector

Electromax. Combined electric boiler and domestic hot water store

Speaker Design Proposal. Alex Palma

Aquatap (Boil only) Installation and user manual

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

QZHW Fan Coil Unit. Key features. Specifications

ECL Comfort V a.c. and 24 V a.c.

Application. Specifications. Finish

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

Unvented water heating

Remote Alarm Panels Features

Installation Instructions CS3 Three Phase Solid State Relay

SUPREMATouch. Modular Fire & Gas Detection System

Process Alarm Module RTA 421

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

DTA. Motor thermistor relay. Benefits. Description

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

Performance Data. curus Component Recognized; File No. E IP 20

ClimaSys Resistance heaters Selection guide

THERMASREG TR 040 THERMASREG TR 060

ESP TECHNOLOGIES LIMITED

PA 500/1100V Ultra Quiet Ventilation Fan

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Overload relays. General descriptions. Configuration of the front

03.03.mmm REV.2 09/01

Sentinel KalGUARD. Product Facts. Water Treatment Equipment to Manage Hard Water Limescale. Features & Benefits. Overview

Local Control Network - building controls in perfection

TrueAlert Addressable Notification Appliances

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

INSTALLATION INSTRUCTIONS

SuperChill 30B Installation and user manual

INTRODUCTION / TABLE OF CONTENTS

Instruction Manual Model A

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

Ordering Key. Dielectric strength

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

Installation & Technical Guide. Domestic & Commercial.

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Commercial Water Heating System (CWHS)

Transcription:

AMPTEC - CONTROL RELAY MO DE L PART NUMB ER DESCRIPT ION COMMENTS RL 1 95 970 134 1 RELAY ASSEMBL Y SUITABLE FOR LINKING AN ELECTRIC SHOWER WITH THE BOILER TO ENSURE THAT BOT H DO NOT RUN AT THE SAME TIME, PREVENTING OVER LOADING THEELECTRICAL SUPP LY. RL 2 95 970 135 2 RELAY ASSEMBL Y 2 BOILER PUMP ISOLATION RELAY. SUITABLE FOR BOILERS BEING CONNECTED ON SI NGLE PHASE OR 3 PHASE SUPPLIES. RL 3 95 970 136 3 RELAY ASSEMBL Y 3 BOILER PUMP ISOLATION RELAY. SUITABLE FOR BOILERS BEING CONNECTED ON SI NGLE PHASE OR 3 PHASE SUPPLIES. RELAY SPECIFICATION Contact Arrangement Contact Rating Coil Consumption Coil Operating Voltage Temperature Range Approvals SPCO 10 amps @ 250Vac 500mW 230Vac -40 C to +70 C VDE, UL, CSA Capacitor (when fitted) 4.7uF 240V 50Hz Class X2 FIGURE ONE: AMPTEC CONTROL RELAY The relay assemblies are mounted on a DIN rail contained in a plastic housing. They can be used for a variety of applications, including controlling the boilers and operati ng pumps. To prevent overloading of the electrical supply where an electric boiler is installed tog ether with an electric shower, the RL1 assembly may be used to temporarily shut do wn the boiler when the shower is in use.

When 2 or more boilers are used together, the output supply for the pump must be is olated. For a 2-boiler system use the RL2 assembly, for a 3- boiler system use the RL3 assembly (for more than 3 boilers apply to Heatrae Sadia for details). These assemblies are quite suitable for boilers connected on a singlephaseelectrical supply, or for boilers connected to different phases of a 3 phase supp ly. They are not suitable for switching the main power to the boilers. Heatrae Sadia Heating Hurricane Way Norwich NR6 6EA www.heatraesadia.com Sadia Heating is a trading name of Baxi Heating UK Limited Main No: 01603 420100 Main Fax: 01603 420218 Sales: 01603 420110 Sales Fax: 01603 420149 Service: 01603 420330 Service Fax: 01603 420349 Page 1 RELAY UNIT -SCHEMATIC (RL2 / RL3). 2 or 3 boilers on single phase 240V or 3 phase 415v supply.

FIGURE TWO: PUMP - RELAY CONTROL FOR AMPTEC BOILERS Isolation relays must be used as shown in the above scheme for 2 or more boilers to operate the pump. Boilers can be connected on a single phase 240v supply or on se parate phases of a 415v supply. RELAY SPECIFICATION: Coil 240v 50 Hz Contacts 240v 10Amps N/O (Normally Open) Isolation - Coil to Contact - 415v minimum working. CAPACITOR: 4.7uF 240v 50Hz Class X2. Page 2 RELAY UNIT -WIRING LAYOUT (RL2 / RL3). 2 or 3 boilers on single phase 240V or 3 phase 415v supply.

FIGURE THREE: WIRING LAYOUT Cap = Capacitor 240v 0.47uf type X2 Model 95 970 135 for 2 boiler assembly Model 95 970 136 for 3 boiler assembly Page 3 SHOWER - RELAY CONTROL FOR AMPTEC: BOILER (RL1).

FIGURE FOUR: SHOWER RELAY CONTOL LIMITATIONS ON ELECTRICAL SUPPLY In the case where there is an electric shower and an electric flow boiler installed, the electrical supply may be overloaded if both units are operating at the same time. To prevent this condition a simple switch over relay box can be added, which will ensure this does not happen. Connections: - The coil of the relay is connected across the switched supply to the electric shower. The 'normally closed' contact of the relay is connected in to the control line of the ele ctric flow boiler. The relay does not switch the high current to the boiler, only the cont rol signals. Operation: - When the shower is switched on, the relay is activated breaking the control signal to the boiler, and hence shutting it down in a controlled maner, thereby preventing over load on the mains electrical supply. Electric showers are normally run for short periods at a time, and therefore shutting d own the heating during these times should not cause any discomfort with the heating.

Note, this is only required if there is doubt with regard to supply limitations, and an el ectric shower that heats the water at the same time as the Amptec boiler is used. It is not required with power showers, which only pump the water. A suitable relay unit is available from Heatrae Sadia. Part number 95 970 134. This r elay unit is also suitable for other applications where there is a high load demand to be shared with the boiler. Other relay units containing 2 or 3 relays are also available from Heatrae Sadia. Page 4