GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

Similar documents
UAS 7000 Local Management

HiGain QUICK INSTALLATION LINE UNIT L 8 HLU 231 DSX-1

GDC 087R705-V200 Issue 1, October Operation. TEAM 7000 for UNIX. Version General DataComm

ADAM. TBOS Adaptor Board. Description. Specifications. Peripherals INTELLIGENT MONITORING THAT BRIDGES THE TECHNOLOGY GAP

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

Model T B Intraoffice T1 Repeater User Manual

FCD-wire Contents. List of Figures

GDC 087R Issue 2 - May Installation and Operation UAS Shelf/Enclosure. General DataComm

TC CH. 600Ω Analog & Dry Contact over T1/E1 Multiplexer. User Manual MNL

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Analog Input Module IC670ALG630

Galaxy Pulsar Plus Digital Battery Plant Controller

LORAIN CIP 4890/48120 DC Power System

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

T3/E3 Fiber Optic Line Drivers

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

DS3/STS-1 Protected Repeater System User Manual

Common Control Cards

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

239 T1 HDSL4 Repeater (H4R) Installation and Maintenance Practice

Engineering Guideline. pac- Carriers Type Universal

Fiber Optical Multiplexer

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

LORAIN CSP DC Power System

USER MANUAL FOR OPERATING SYSTEM

RAy SNMP. Application notes.

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

OVEN INDUSTRIES, INC.

Four channel video link For low cost video transmission

UNC100 Integra Manual

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

TM-76, MD-76 MODEM OPERATING MANUAL. IOA76-1F May 2009 LANEX S.A., 8 Ceramiczna Street, Lublin Service: phone POLAND

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

087R Issue 1 December 2000 UAS DIU 7723 MR Installation and Operation Manual

ModBus DE-1 INSTALLATION AND USER MANUAL

Total Access 1500 SCU Installation and Maintenance

ECO N DATE DESCRIPTION OF CHANGE CHG

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

QS941A Controller User Interface

Tixi Alarm Modem Aluminum Housing Analog / ISDN / ISDN & Fax / GSM

P2267 NETWORK INTERFACE

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

High-Speed Voice and Data Link Access Multiplexer

Model 135 Reference Document

INSTALLATION INSTRUCTIONS

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

HRX Technical Manual. Version 1.2

GLOBAL. InstallatIon & operation manual

IRIS Touch Firmware Enhancements and Additions from Version to Version

Azatrax Quad Infrared Proximity Detector Shield for ArduinoTM Uno, Mega and compatibles

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

Vector System. User Manual

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

20 Light Remote Annunciator

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

CPS3200U Technical Support Guide

Dry Contact Probe DCP (#30008)

VPS3 Installation Manual

F Technical Bulletin SC 370 SMART Modbus Interface

Manage Alarms. Before You Begin CHAPTER

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

C-Bus Four Channel General Input Unit Installation Instructions

Manage Alarms. Before You Begin CHAPTER

installation & operation manual

ESSEX ENGINEERING CORPORATION

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Network Maintenance: Alarm and Control for Network Elements

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Power Management and Environmental Monitoring

Added password for IP setup page : Password must be in IP format!

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Contents. Glossary

Series Digital Controller Instruction Sheet

AIS750 Series Alarm Annunciator

IntesisBox BACnet/IP Server - Notifier ID3000 series

Alarms Manual. ver.1 rev.06/'07. Enclosures to Service Manuals of: McbNET Digital TM Magnum400 TM MiniMagnum400 TM. 6) Speeder One

Module Features are-configurable, no module jumpers to set

HiGain H2TU-C-319-L72 Line Unit Quick Installation Guide

InBio X60 Series Access Control Panel User Manual

Operations Manual TS400. Test Station for G450/G460 Gas Detector

EX41922 Hardened Unmanaged 2-port 10/100/1000BASE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

Technical Manual. Level Alarm Unit CARLA & WIDS

Isolated Thermocouple Module

21-light Remote Annunciator. Owner s Manual

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

WIRELESS NETWORK USER MANUAL MHz RFT-868-PIR Wireless Passive Infrared Sensor

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

HM-4201-RTCM High-Temp Real Time Clock Module

SC-F3G User Manual 1.0

Transcription:

GDC 087R707-001-01 Issue 1 - May 1998 Installation and Operation UAS 7000 Network/Dropside Interface Unit Model NIU/DIU General DataComm

Manual Revision History Shown below is a chronological listing of revisions to this manual. The issue number, date, and synopsis of revised materials are included to provide the reader with a comprehensive manual history. Note In keeping with the policy of continuing development carried out by General DataComm Inc., the information in this manual is subject to revision without notice. Issue Date Description 1 May 98 First issue.

NIU/DIU Table of Contents NIU/DIU... 1 Features... 1 Options... 3 Installing the NIU/DIU... 5 Cabling the... 6 Mixing Cards in The UAS Shelf... 6 50-Pin Telco Mapping... 7 DB-25 Zone 3 Pinouts... 8 Front Panel Indicators... 9 Tests... 10 T1 Line Loopback... 10 T1 Payload Loopback... 10 Self Test... 10 Digital Loopback... 11 Remote Digital Loopback... 11 Remote Digital Loopback with Self Test... 11 Remote Bilateral Loopback... 12 Remote Bilateral Loopback with Self Test... 12 Master to Remote Self Test... 12 Remote to Remote Self Test... 13 Parts List and Specifications... 14 GDC 087R707-001-01 i

NIU/DIU NIU/DIU The UAS NIU/DIU multiplexes 12 IDSL (ISDN DSL) interfaces into a single T1. This dual-slot card provides the same function as one NIU 7001 and four DIU 7616ML s, and increases the capacity of a dual UAS 7000 shelf nearly four times. For example: a dual UAS 7000 shelf can accommodate fourteen managed T1s. Four shelves accomodate 28 T1s or 1 DS-3 worth of bandwidth in 28" of rack space. A 7-foot high rack can accomodate 2 DS-3 payloads or 56 T1s. It allows service providers to utilize the entire T1 bandwidth when offering IDSL (128k) service. The UAS fits into the UAS 7000 shelf and is controlled by the TEAM for UNIX Manager, by Local Management VT-100 or Telnet, or by hard configuration via DIP switches. Features ON RSP 1 4 2 5 LOOPS 7 10 8 11 NIU: 3 6 9 12 DSX-1 (per ANSI T1.102) or DS1 (per ANSI T1.403) operation. ESF or SF framing. B8ZS or AMI Line Coding. TM ALM LCV AIS OOF LOS DSX-1 Pre-Equalization: 0-655 ft. in 130 ft. increments. DS1 Line Build Out: 0, -7.5, -15, or -22 db. FDL messaging: ANSI T1.403 or Bellcore TR54016. Configuration via SNMP commands using the SNMP GDC SCM card, via Telnet using VT100 connected to craft port of SCM card, or via hardware DIP switch settings. Fixed DSL to T1 DS0 mapping (for example: DSL 1 to DS0 1 and 2, DSL 2 to DS0 3 and 4, etc.) Selectable Payload or Line Loopbacks Performance monitoring per ANSI T1.403 and Bellcore TR54016. Selectable Recovered or Internal Transmit Timing. Selectable AIS Loop Down: Inhibit or 5-60 seconds in 1 second increments. GDC 087R707-001-01

NIU/DIU DIU: Twelve (2B1Q U-Interface) IDSL s per ANSI T1.601. Management of GDC s DataComm 610/612/621 modems using the EOC (Embedded Operations Channel). LAP-D (Link Access Procedure - D channel) signaling to establish 64 kbps PPP (Point-to- Point Protocol) or 128 kbps PPP-ML (Point-to-Point Protocol - Multilink) sessions between Terminal Adapter (TA) and Internet Protocol (IP) router devices. Provides loop current to detect continuity. Initiation of ANSI T1.601 2B+D loopback from DIU to any remote. 2047 test pattern generator and checker for each DSL (GDC 600 series NTU products) Performance monitoring, such as Maintenance, Alarms, Programmable Alarm Thresholds, and Diagnostics. 2 GDC 087R707-001-01

NIU/DIU Options The NIU/DIU consists of three printed circuit cards, a basecard (not shown in Figure 1), a daughter card and a plug-in card. Figure 1 shows the daughter card and the plug-in card where DIP switch S1 is mounted. Table 1 describes the hard options selected by S1 that can be set Up or Down with a small screwdriver. Table 2 describes the soft options selected by Telnet - Operation UAS Local Management GDC Pub. No. 087R710-000, or the TEAM for UNIX GDC Pub. No. 087R708-V100. You need to check these settings when you first install the card. You need not repeat the procedure unless you change the network. Zone 1 Connector (DSL) Zone 2 Connector (Backplane) XAP21 S1 Piano-type DIP switch mounted on component side of card XAP20 Plug-In Card 087P012 Zone 3 Connector (T1) DEFAULTS: Daughter Card The Default option choices (italics) are not silkscreened on the card. Default positions are Down (Off) towards the daughter card. Refer to Table 1 and Table 2 for option settings. SOFT ESF DSX-1 B8ZS BELL LBO 0dB Pre-Equal.0-130ft. XAP21 S1 HARD SF DS1 AMI ANSI SL0 SL1 SL2 Option (Up) silkscreening on circuit-side of card. Exploded View of Plug-In Card XAP20 Figure 1 NIU/DIU Option Selection GDC 087R707-001-01 3

NIU/DIU. Table 1 NIIU/DIU Hard Configuration Option Settings Options Default Position of S1 (Down = Off) Description SOFT/HARD SOFT You may select hard or soft configuration. ESF/SF ESF Framing Mode: ESF - Extended Super Frame: consists of twenty four consecutive frames. SF - Superframe: consists of twelve consecutive frames. DSX-1/DS1 DSX-1 Network Interface Type: DSX-1 - configures the interface to operate as a standard cross-connect DSX-1. DS-1 - configures the interface to operate as a standard DS-1. B8ZS/AMI B8ZS One of two types of network interface Line Coding may be selected: B8ZS - Bipolar with 8 Zero Substitution encoding. AMI - Alternate Mark Inversion encoding. BELL/ANSI (DS-1) SL0 - SL2 BELL Selects FDL mode: ANSI T1-403 - bit oriented. Bellcore - TR54016 - byte oriented (HDLC). Allows you to select Line Buildout (LBO) for a DS-1 Network Interface Type or Pre-Equalization for a DSX Interface Type. Refer to "SL0/SL2 Option Settings" table below. LBO 0 db Line Build Out is the line build out value of the DS-1 interface. The selections are: 0, -7.5, -15, and -22 db. Pre-Equalization 0-130 ft. Pre-Equalization is the pre-equalization of the transmitter of the DSX-1 interface. The selections are: 0-130, 130-260, 260-390, 390-530, and 530-655 feet. SL0/SL2 Option Settings LBO Pre-Equalization SL2 SL1 SL0 (DS-1) (DSX-1) Off Off Off 0 db 0-130 ft. Off Off On -7.5 db 130-260 ft. Off On Off -15 db 260-390 ft. Off On On -22 db 390-530 ft. On X X do not use 530-655 ft. Off = Down (toward daughter card) On = Up X = Don t Care 4 GDC 087R707-001-01

NIU/DIU Table 2 NIU/DIU Soft Configuration Option Settings Options Default Description ESF/SF ESF Same as S1 switch setting in Table 1. DSX-1/DS1 DSX-1 Same as S1 switch setting in Table. B8ZS/AMI B8ZS Same as S1 switch setting in Table 1. Line Build-Out n/a n/a. Pre-Equalization 0-130 Same as S1 switch setting in Table 1. Extra options available when soft configured BELL/ANSI/None None Selects either BELL, ANSI or None. Recovered/Internal Transmit Timing Recovered Installing the NIU/DIU Allows you to select the Transmit Clock source: Recovered - Slave timing from the T1 network. When Recovered is selected and there is no timing source, transmit timing defaults to Internal. Internal - Internal clock source. Inhibit/ Inhibit Allows you to select or inhibit the Loopback Configuration: Inhibit - When you select this option, inband codes are ignored. Payload - When selected, the recovered T1 is looped back toward the network. Line Loop - When selected, the Telco received signal is looped back toward the network. Both Payload and Line loopbacks are initiated upon recognition of inband loop-up codes or by using UAS Local Management or UAS TEAM for UNIX Manager. AIS Loop-Down Inhibit/5-60 seconds in 1 second Increments Inhibit You can select or inhibit the AIS Loopdown time - The time in seconds when receiving a continuous AIS before a network- initiated loopback is terminated. This time-out can be 5 to 60 seconds, or inhibited. Framing Mode Manual Allows you to select automatic or manual Framing Mode. LBO Control Manual Allows you to select automatic or manual Line Build-Out for DS-1. When you are satisfied that the option settings on the plug-in card are correct, install the card in the shelf following the directions below: 1. Insert the card into its slot with the GDC logo on top, then slide it in until it makes contact with the rear panel connectors. 2. Pull down the insertion/extraction tab on the front panel and firmly push the card in until it seats in the rear connectors. To remove a card, pull down the insertion/extraction tab to unseat the card, then pull back on the tab. GDC 087R707-001-01 5

NIU/DIU Cabling the 50-pin Telco connectors J17 and J20 provide the DSL connections to the cards installed in slots 1-6. Likewise, J18 and J21 provides the DSL connection for slots 7-12. J19 provides the connections for slots 13-16 Refer to Table 3 for connector pinouts. The shelf also provides 16 DB- 25 connectors in Zone 3. Refer to Table 4 for connector pinouts. Mixing Cards in The UAS Shelf When you mix NIU/DIU s with NIU 7001s and DIU 7616s in the same UAS Shelf we recommend that you install the 7001 cards in slots 13 to 16 (shaded areas) and the 7616 and cards in slots 1 to 12. You can then cable the T1 and DSL connections as shown in Figure 2. This avoids mixing T1 and DSL signals in the same 50-pin connector. The lower-numbered DB-25 connector of the pair of slots occupied by the provides the T1 signals. Use wire-wrap adapter (048P068-001) at this connector for connection to a RJ48H E-Block. 66 E-Block 66 E-Block 66 E-Block 66 E-Block 7616 or /DSL /DSL 7616 or /DSL /DSL J19 J18 Slots 13-16 Slots 7-12 Slots 1-6 T1 Not Used DSL DSL J22 DSL DSL J21 J17 J20 J16 J15 J14 J13 J12 J11 J10 J9 J8 J7 J6 J5 J4 J3 J2 J1 Rear View UAS Shelf NIU 7001 /T1 Adapter No. 048P068-001 DB25 to Wire-Wrap (typical) 66 E-Block RJ48H Figure 2 A Mixed UAS Shelf 6 GDC 087R707-001-01

NIU/DIU 50-Pin Telco Mapping Refer to Table 3 for the pin mapping of the 50-pin Telco connector. Table 3 50-Pin Telco Mapping (UAS Shelf Rear Panel "J" Nos.) When mixing cards, refer to "Mixing Cards in The UAS Shelf" on page 6. in slots 1 & 2 in slots 3 & 4 in slots 5 & 6 in slots 7 & 8 in slots 9 & 10 in slots 11 & 12 in slots 13 & 14 in slots 15 & 16 Slot No. "J" No. DSL DSL DSL Tip Ring Tip Ring Tip Ring 1 20 DSL1 1 DSL1 26 DSL2 28 DSL2 3 DSL3 4 DSL3 29 1 17 DSL4 1 DSL4 26 DSL5 28 DSL5 3 DSL6 4 DSL6 29 2 20 DSL7 5 DSL7 30 DSL8 32 DSL8 7 DSL9 8 DSL9 33 2 17 DSL10 5 DSL10 30 DSL11 32 DSL11 7 DSL12 8 DSL12 33 3 20 DSL1 9 DSL1 34 DSL2 36 DSL2 11 DSL3 12 DSL3 37 3 17 DSL4 9 DSL4 34 DSL5 36 DSL5 11 DSL6 12 DSL6 37 4 20 DSL7 13 DSL7 38 DSL8 40 DSL8 15 DSL9 16 DSL9 41 4 17 DSL10 13 DSL10 38 DSL11 40 DSL11 15 DSL12 16 DSL12 41 5 20 17 42 44 19 20 45 5 17 17 42 44 19 20 45 6 20 21 46 48 23 24 49 6 17 21 46 48 23 24 49 7 21 1 26 28 3 4 29 7 18 1 26 28 3 4 29 8 21 5 30 32 7 8 33 8 18 5 30 32 7 8 33 9 21 9 34 36 11 12 37 9 18 9 34 36 11 12 37 10 21 13 38 40 15 16 41 10 18 13 38 40 15 16 41 11 21 17 42 44 19 20 45 11 18 17 42 44 19 20 45 12 21 21 46 48 23 24 49 12 18 21 46 48 23 24 49 13 22 1 26 28 3 4 29 13 19 1 26 28 3 4 29 14 22 5 30 32 7 8 33 14 19 5 30 32 7 8 33 15 22 9 34 36 11 12 37 15 19 9 34 36 11 12 37 16 22 13 38 40 15 16 41 16 19 13 38 40 15 16 41 Note: This table assumes you install a starting with slots 1 & 2. If the is placed in another pair of slots, the DSL numbers will change accordingly. GDC 087R707-001-01 7

NIU/DIU DB-25 Zone 3 Pinouts Refer to Table 4 for the pin mapping of the Zone 3 DB-25 connector. Table 4 Zone 3 UAS Shelf DB-25 Pinouts Zone 3 (P2) DB-25 Pin No. Description Direction 3 Transmit Tip From 16 Transmit Ring From 1 Receive Tip To 14 Receive Ring To 8 GDC 087R707-001-01

NIU/DIU Front Panel Indicators Table 5 describes the front panel indicators. Table 5 Front Panel Indicators LED ON RSP LOOPS TM ALM LCV AIS LOS OOF Indicators Use Power applied Green - Lights when power is applied. Response Green - Lights upon transmission of a backplane management response. Loop LEDs Red/Green (Bi-color) - Solid green = Good connection and in sync; Flashing green = Loop in test; Red = Alarm state (no current or sync.) Test Mode Red - Lights when the test mode is entered by NIU. Alarm Red - Flashes during LCV, AIS, OOF, or LOS states. Line Code Violation Red - Lights upon reception of bipolar violations in the received T1 AMI signal. Alarm Indication Signal Red - Lights upon reception of a signal from the network Terminal Element (TE) that it cannot send a framed DS1 signal. Loss Of Signal Red - Lights upon absence of received T1 signal. Out Of Frame Red - Lights upon detection of severely errored seconds or wrong T1 framing pattern. ON RSP LOOPS 1 2 3 TM 4 5 6 ALM 7 8 9 10 11 12 LCV AIS OOF LOS GDC 087R707-001-01 9

NIU/DIU Tests The NIU/DIU performs the following diagnostic loopbacks: See Figure 3 through Figure 11. UAS Local Management (VT-100 or Telnet) may initiate, T1 Line Loopback, T1 Payload Loopback, Digital Loop, Self Test, and Remote Digital Loop. TEAM for UNIX Manager, can control all tests. T1 Line Loopback T1 Line Loopback loops the Telco receive path to the transmit path, back towards the T1 network. T1 Line Network Line Loop Interface M U X No Loop Drop Interface Figure 3 T1 Line Loopback T1 Payload Loopback T1 Payload Loopback loops the recovered T1 receive path to the transmit path, back towards the T1 network and corrects bipolar violations. T1 Line Network Payload Interface Loop M U X No Loop Drop Interface Figure 4 T1 Payload Loopback Self Test Self Test transmits a 2047 bit pattern and tests the receiver for bit errors. T1 Line Network No Loop Interface M U X Self Test Drop Interface Pattern Generator No Loop Remote DC610, 612 or 621 DTE Figure 5 Self Test 10 GDC 087R707-001-01

NIU/DIU Digital Loopback Digital Loopback loops 128 kbps (two DSOs) received path to transmits path back towards the T1 network. T1 Line No Loop Network Interface M U X Digital Loop Drop Interface Figure 6 Digital Loopback Remote Digital Loopback Remote Digital Loopback commands a remote unit to go into loopback. T1 Line Network No Loop Interface M U X No Loop Drop Interface Digital Loop Remote DTE DataComm 610, 612, 621 or TA TA = Terminal Adapter Figure 7 Remote Digital Loopback Remote Digital Loopback with Self Test Remote Digital Loopback with Self Test commands a remote device to go into loopback, and the transmits a 2047-bit pattern and tests the receiver for bit errors. T1 Line Network No Loop Interface M U X Self Test Drop Interface Pattern Generator Digital Loop Remote DTE DataComm 610, 612, 621 or TA Figure 8 Remote Digital Loopback with Self Test GDC 087R707-001-01 11

NIU/DIU Remote Bilateral Loopback Remote Bilateral Loopback is performed at a remote unit. T1 Line Network No Loop Interface M U X No Loop Drop Interface Bi Loop Remote DataComm 610, 612, 621 DTE Figure 9 Remote Bilateral Loopback Remote Bilateral Loopback with Self Test Remote Bilateral Loopback with Self Test is performed at a remote unit, and the master is generating the 2047 self-test pattern. T1 Line Network No Loop Interface M U X Self Test Drop Interface Pattern Generator Bi Loop Remote DataComm 610, 612, 621 DTE Figure 10 Remote Bilateral Loopback with Self Test Master to Remote Self Test Master to Remote Self Test puts the and the remote into a self-test (2047 test pattern only). T1 Line Network No Loop Interface M U X Self Test Drop Interface Pattern Generator Self Test Remote Pattern Generator DTE DataComm 610, 612, 621 Figure 11 Master to Remote Self Test 12 GDC 087R707-001-01

NIU/DIU Remote to Remote Self Test Remote to Remote Self Test puts the remote unit into self-test (master is transparent). (2047 or 511 test pattern). T1 Line Network No Loop Interface M U X No Loop Drop Interface Self Test Remote Pattern Generator DTE DataComm 610, 612, 621 Figure 12 Remote to Remote Self Test GDC 087R707-001-01 13

NIU/DIU Parts List and Specifications The parts list and specifications for the NIU/DIU are found in Table 6. Table 6 Parts List and Specifications Parts List 087M010-001 NIU/DIU module (base card, daughter card and plug-in card) 048P068-001 DB-25 to Wire-Wrap Adapter 830-002S-xxx Amphenol 50-pin male- to-male cable (xxx= 5, 10, 25 and 50 ft. lengths) Specifications Dimensions Height Width Depth Weight Power Load Number Network Management Protocol SNMP Ambient Temperature operating non-operating Humidity (operating) Altitude operating non-operating Diagnostics Communication line Line Impedance Frequency Line Build-Out Pre Equalization Sealing Current Operating Mode Data Rate Data Format Line Coding Line Requirements Operating Range Performance 7.0 in. (178 mm) 1.75 in. (44.5 mm) 9.5 in. (241 mm) 1.9 lbs. (0.85 kg) + 5 Vdc at 2A (max.) +12 Vdc at 50 ma (max.) -12 Vdc at 50 ma (max.) 2.0 (for 2 slots) 0 to 50 C -40 to 85 C 5% to 95% (non condensation) 0 to 10,000 feet 0 to 40,000 feet NIU Interface Line Loopback, Payload Loopback, Digital Loopback. T1 digital carrier 100 ohm 1.544 Mbps ±50 bps 0, 7.5, 15, or 22.5 db at 772 khz 0-130, 130-260, 260-390, 390-530, 530-655 feet. DIU Interface 4.5 ma nominal Full duplex with adaptive echo cancellation. 160 kbps total: 128 kbps user data, 16 kbps internal control, 16 kbps for timing and synchronization. Synchronous, serial binary. 2B1Q, compatible with ANSI T1.601. 2-wire, non-loaded metallic circuit. 18 kft. of 26 ga.wire 10-7 BER on 15 ANSI T10601 test lamps. 14 GDC 087R707-001-01

Index NIU/DIU DB-25 Zone 3 Pinout 14 Features 1 Front Panel Indicators 2 D F I Installation of Plug-In Card 4 Installing the NIU/DIU 5 Manual iv Options 3 M O P Parts List and Specifications 8 Tests 10 T GDC 087R707-001-01 Index-1

General DataComm