OPTICAL TURNSTILE SYSTEM

Similar documents
4040 FM 535 F :

OPTICAL TURNSTILE SYSTEMS

Bi-Directional Barrier Arm Turnstile

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

ARCHITECTURAL SPECIFICATIONS

OptiStile 220. Swinging Barrier Arm Optical Turnstile

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller:

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

SP-1000X. Panic Device Power Controller Installation Guide. Rev

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm)

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

ESP TECHNOLOGIES LIMITED

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

OptiStile 400. Non-Barrier Optical Turnstile

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

TECHNICAL INFORMATION T1500 Series Clothes Dryers

ANNUNCIATOR FIXED MODULE

ES880 GLASS BARRIER OPTICAL TURNSTILE INSTALLATION AND OPERATION

TECHNICAL INFORMATION T 15xx Dryers

Tailgate > Entry Sentry > ES5200

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Addendum for STI-6406 with Dual Access Control

TECHNICAL DATA OBSOLETE

1.1 Ensure the room is in the ACCESS state. Workstation indicates zone is in ACCESS state.

RMS/RPX Reader. User Manual

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

Public Safety DAS Annunciator Panel

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

WAILEA OWNER S MANUAL

Installation and Operation Manual Low Power (LP) DC Power System

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

CARD ACCESS CONTROL SYSTEM

D A R A - 4. Data Aire Relay Auto-Changeover

Remote Chexit Module (RCM) System. General Information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Installation Guide for models:

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

4100U City and Relay Cards Installation Instructions

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Installation, Operating and Maintenance Manual

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

MANUAL RESET ALARM RELEASE

Specification/ Data Sheet

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Intelligent Security & Fire Ltd

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

EXTINGUISHING AGENT RELEASE MODULE

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

DS160/161 Request To Exit PIR sensors Installation Instructions

MANUAL RESET ALARM RELEASE

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

DS160/DS161 Request To Exit PIR sensors Installation Instructions

SAFETY INFORMATION AND WARNINGS

Outline Specification: EDSUKMT1 MAN TRAP CYLI NDER GATE

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

Universal Gas Detector

400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W

KT-100 Door Controller

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Pioneer-R16 Gas Monitor Operator s Manual

FMR Installation Instructions. Addressable Fire System Controller

UNC100 Integra Manual

Installation Instructions

E-PLEX 5x70 Series Stand-Alone Access Controller. Installation Instructions

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Flair 500 Series Annunciators

DE5300 Delayed Egress System. General Information

PARVIS Safe and tranquil thanks to Parvis

TECHNICAL INFORMATION Touchtronic Clothes Dryers

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Control/Communicator

30-YEAR LIMITED WARRANTY

D1255RB/D1256RB/D1257RB

Soft Start Series MP700 Solid State, Reduced Voltage

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

D720 and D1255 Command Centers

Installation Guide for models:

PROFESSIONAL S2 SAFE USER GUIDE ELECTRONIC LOCK USER GUIDE.

DRAFT 20 October 2014

Classic Twelve O clock Cabinet Installation Instructions

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

MODEL B2 INSTALLATION MANUAL

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Transcription:

OPTICAL TURNSTILE SYSTEM Installation Instructions OTS-WNG UNPACK TURNSTILES. Remove the bolts at the ends of the turnstiles to separate from the skids and place turnstiles on the floor. With a box knife cut the cardboard flaps at the front of the housing next to the wood base. Cut the cardboard along the long side of the board just above the staples. Be careful not to damage the turnstile housings. Lift off the cardboard, the turnstile is protected by plastic and surrounded by foam. Refer to Figure. Remove the bolts at the ends of the turnstiles to separate from the skids. Cut cardboard above the staples that attach it to the wood base. Be careful not to damage the turnstile. Figure. Insert the keys into the key cylinders located in each side panel. Rotate the keys inward to release the latch holding the side panels to the frame. The side panels are also attached with Velcro. 3. To remove the side panels, slowly pull the panels from the bottom left and right corners utilizing enough force to separate the corners of the side panel from the frame approximately ¾ of an inch. 4. Pull the side panel from the bottom middle until it separates from the Velcro. Lift the side panel up and pull off. Keep track of the side panels as they relate to each turnstile. The panels are interchangeable but minor factory adjustments were made to ensure proper fit.. With the side panels removed, locate the lag bolts or carriage bolts that are used to attach the turnstile frame to the wood base. Remove these and discard the wood base. 4040 FM 3 Page Fax: -3-469

TURNSTILE MOUNTING CAUTION: The units weigh approximately 80 pounds. 6. Position the units at the installation location using a chalk line to ensure proper alignment. If the units were custom designed for a specific application then space turnstile as required for application. If the units are not custom we recommend that spacing between the turnstiles be 30 to 3 inches for standard walkways and for ADA designated walkways 36 to 38 inches. Please take into consideration that at least one walkway should accommodate ADA requirements. Mark the position of each turnstile. ATTENTION: ½ inch anchor bolts are provided. Each of the housings require 8 anchor bolts to sufficiently attach the housings to the floor. DO NOT USE SMALLER ANCHOR BOLTS TO MOUNT THE HOUSINGS. Failure to use the correct size and number of anchor bolts will void the manufacturer s warranty. 7. Remove the nuts and washers that attach the frame to the sub-mounting base. Do not remove the leveling washers and nuts from the sub-mounting base. 8. Drill the anchor bolt holes using the sub-mounting base as the template. Be careful not to move the sub-mounting base while drilling the anchor bolt holes. 9. Set the anchor bolts through the sub-mounting base, install the washers and nuts, and then tighten until sub-mounting base is secured to the floor. 0. Position a level length wise and cross wise across the leveling washers and adjust until all washers are level with the adjacent washer. Once all washers are level with each other reinstall the housing and tighten. WIRE REQUIRMENTS Refer to the system level-wiring diagram for cabling requirements. The housings with the lane electronics and card readers will require: 3 conductor 4 AWG minimum for 0 VAC Power to each housing 6 conductor AWG minimum for interface to the access control system 6 conductor shielded AWG minimum housing to housing 4 conductor AWG minimum to interface with the annunciator Card Reader cable from Card Access System to each housing WIRE TERMINATIONS Refer to the system wiring diagrams for exact terminations and signal definitions. The valid card signal is to be connected to the card reader lock output relay. The lock output relay must be configured for second maximum contact duration or to automatic relock when the door is opened. The door-input circuit of the card reader system should be connected to the entry acknowledge or exit acknowledge relay output on the lane control panel. The entry acknowledge or exit acknowledge relay output operates as a door mimic operation. The relay closes when a person walks through the lane, and re-opens when the lane is clear. The card reader system detects that relay cycle as a normal door unlock and open sequence. If a person walks through the lane without a valid card, then the relay closes. The card reader system detects that relay closing as a forced door. 4040 FM 3 Page Fax: -3-469

Inputs: Entry Card (momentary) Input this input is activated by the access control system to allow a valid entry passage through the lane. The access control system lock relay should be configured to provide a maximum second pulse to this input. Exit Card (momentary) Input this input is activated by the access control system to allow a valid exit passage through the lane. The access control system lock relay should be configured to provide a maximum second pulse to this input. Invalid Card (momentary) Input this input is activated by the access control system to notify the card holder that their badge was read but access is denied. The card holder is alerted to the status by the flashing red LED arrays mounted under the glass and a distinctive chime. Bypass / Fire Alarm (maintained) Input this input can be activated by the fire alarm system, access control system or from a remote switch. When activated the wings retract and both LED arrays mounted behind the glass illuminate green. In this condition the unit will not alarm if individuals pass through the lane. Wing Disable Optical Only (maintained) Input this input when activated retracts the wings and allows the turnstile to operate as an Optical Turnstile without barrier. Outputs: Entry Alarm Relay activates when an invalid entry through the lane occurs. Exit Alarm Relay activates when an invalid exit through the lane occurs. Wing Fault Relay - activates when the wing is out of position or is retracted due to a fire alarm or bypass input. Bypass Status Relay activates when a fire alarm or bypass input is activated. Desktop Control Panel The lane desktop control panel is provided to annunciate the lane operation at a guard desk. Five LED s are provided, Red = alarm, Green = bypass, Yellow = invalid card, Green = Normal, and Yellow = Wing Fault. An alarm sounder activates on either lane alarm, and an invalid card chime activates when either lane receives an invalid card signal from the card reader system. The keyswitch and pushbutton can be terminated to the lanes bypass input to provide for a momentary bypass or maintained bypass of the lanes. OPERATION VERIFICATION. INITIAL POWER UP: Apply 0 VAC to the power input; this will power up the control board and the sensors. The wings will begin to move automatically extending out, returning back in and then out again before stopping. This is the homing sequence and it should not be interfered with. If the wings are stalled prematurely from someone or something stopping them, the sequence will have to be restarted by a power off and on sequence. Once both wings are extended the unit is ready to test.. SENSOR TEST: Each infrared sensor has a red and green LED. When adjusted properly the green LED should be illuminated only. The red and green LED should illuminate if the sensor is blocked. 4040 FM 3 Page 3 Fax: -3-469

3. FIRST WALK TEST: The Red PRESENT CARD LED array on the top should be illuminated. Walk into the sensing area from the entry side. The unit should provide an audible sounder and the entry alarm relay should activate. Walk through the unit in the exit direction. The units barrier should open and allow a person to walk through the unit. An audible sounder and the exit alarm relay should activate. 4. SECOND WALK TEST: Present a valid card at the reader and ENSURE the valid card input contact is CLOSED. The Green PROCEED LED array on the display should illuminate and the barrier wings should open. Walk through the unit and the LED arrays should return back to illuminating red and the barrier should close. Repeat this procedure but in the exit direction. The unit should allow passage without creating an alarm.. THIRD WALK TEST: Present a valid card to the reader, and have two people walk through the sensing area close together. An alarm should be generated. Repeat this several times varying the distance between the two people. At some point of closeness, an alarm will not be generated. The tailgate sensitivity adjustment is provided to set the alarm distance between people. 6. ADJUSTMENTS - Refer to the photo of the control board for the location of the adjustment delays. The Tailgate sensitivity adjustment is used to allow purses, bags, umbrellas, etc to be carried through the sensing area without generating a false alarm, while maintaining a valid level of tailgate monitoring. This adjustment can be set for very sensitive tailgate detection, which can cause false alarms when bags and other objects are carried through the sensing area. Or this adjustment can be set for loose tailgate detection, which can allow someone to follow a person through the sensing area without generating an alarm. Maximum sensitivity is with the pot set toward the programming jumpers or counterclockwise. Minimum sensitivity is with the pot set away from the jumpers. The pot. has a 80-degree turn. FINAL ASSEMBLY After the turnstiles are mounted and system operation is verified, remove the remaining protective covering from the side panels and install back on the corresponding turnstiles. The panels may be interchanged but it is recommended that the side panels be placed back on their original positions and housings. CLEANING The lanes may be kept clean by using any household or industrial grade stainless steel and window cleaner. ELECTRICAL CHARACTERISTICS System power requirements: Input Voltage 0 VAC, 60 HZ, 0 Amp dedicated circuit for each group of lanes (consisting of up to three walkways). A 00 Watt UPS backup for each lane is recommended to maintain operation during power grid faults. If building backup electric generators take longer than 30 seconds to provide stable 0 VAC/60 HZ power during an outage, then the UPS backup wattage will need to be increased. Internal power: The PLC is powered directly from 0 VAC. Sensors and indicators are powered from an internally mounted enclosed switching VDC 40 Watt power supply with built in EMI filter. Stepper motor is powered from an internally mounted enclosed switching 48 VDC 300 Watt power supply with built in EMI filter. Power supplies are UL listed for industrial control applications. 4040 FM 3 Page 4 Fax: -3-469

Control system: The control system is PLC based. The control program is in non-volatile memory and is retained during power loss. The operational variables including time delays, operational status, wing position, sensor conditions are in random access memory, and are not retained during power loss. The PLC system has UL, CUL, and CE agency approvals. Presence and direction sensors: The sensors are long range diffuse scan active infrared sensors or through beam active infrared sensors or can be a combination of both. The sensors are provided with automatic interference prevention. The sensing range is up to meters. The sensitivity is factory preset to 8 inches for non-ada lanes, and 36 inches for ADA lanes. Response time is ms or less. Operating voltage is VDC @ 0 ma max. The sensors are UL listed for industrial control applications. Wing position sensor: The wing position sensor is a light industrial grade 000 step per revolution, two phase quadrature output optical encoder. Operating voltage is VDC @ 0 ma max. The optical encoder is UL listed for industrial control applications. Stepper Motor Drive: The stepper motor drive is a 4 phase bi-polar pulse width modulated chopper drive with optoisolated command interface. Maximum output current is AMP. It is manufactured by Pacific Scientific. The motor drive is UL recognized for industrial control applications. Stepper Motor: The stepper motor is a NEMA 34 bipolar micro stepping motor manufactured by Pacific Scientific. Max rated current 4.3 AMP. Output torque range 0.6.39 Nm. The stepper motor is UL listed for industrial control applications. 4040 FM 3 Page Fax: -3-469

4 CONDUCTOR AWG TO ANNUNCIATOR WING EXTENDED ANNUNCIATOR LANE POWER SUPPLY 0 VAC @ 0 AMPS PER EVERY GROUP OF HOUSINGS NOT TO EXCEED 3 WALKWAYS WALKWAY 6 CONDUCTOR AWG HOUSING TO HOUSING 6 CONDUCTOR AWG and 3 CONDUCTOR 4 AWG CARD READER CABLE 3 CONDUCTOR 4 AWG CARD READER CABLE 4040 FM 3 Page 6 Fax: -3-469

SWITCH (RUN, TERM, STOP) SERIAL PORT CPU PWR BATT RUN CPU IN ACT CTR IN OK ER +4VDC OUT OUTPUTS A 0 0 4 RELAY OUT A 0 RELAY 4 C CTR 3 B 3 B 3 DL0- CPU RUN TERM STOP A0 A4 A A A A6 A3 A7 H - CTRIO D - TR D - TR D - FILL CI CI B0 B4 4 VDC + OUT PORT B B B B6 B3 B7 CII CII C0 C4 C C C C6 C3 C7 CIII CIII D0 D4 D D D D6 D3 D7 CIV CIV A A B B C C D D M M NC C C0 Y C3 Y3 Y0 C Y 0 3 0 3 CA 4 CB 4 0 3 0 3 CA 4 CB 4 4 VDC - PORT D6 CIV D7 D D4 CIII C4 C7 C6 C CII B7 B6 B4 A7 B CI A6 A A4 8 7 6 LOCK+ 8 LOCK+ LOCK- 7 LOCK- COMMON + VDC 6 COMMON + VDC REX NEGATIVE REX NEGATIVE RELAY 3 4 BYPASS RELAY 3 RELAY 4 3 COMMON RELAY 4 RELAY DOOR RELAY RELAY 6 COMMON RELAY 6 4 BYPASS 3 COMMON DOOR COMMON CIV D3 D D D0 CIII C3 C C C0 CII B3 B B B0 CI A3 A A A0 3 4 6 7 8 9 0 3 4 6 7 8 9 0 3 4 6 7 8 9 0 3 4 6 7 8 3 4 6 7 8 3 4 6 3 4 6 7 8 9 30 ANNUNCIATOR POWER VDC ANNUNCIATOR POWER COMMON ANNUNCIATOR BYPASS LED ANNUNCIATOR WINGFAULT LED ANNUNCIATOR ALARM LED ANNUNCIATOR INVALID CARD LED ANNUNCIATOR NORMAL LED ANNUNCIATOR BUTTON / KEYSWITCH ANNUNCIATOR INVALID CHIME ANNUNCIATOR ALARM BUZZER REMOTE MOTOR REMOTE MOTOR REMOTE MOTOR 3 REMOTE MOTOR 4 REMOTE MOTOR REMOTE MOTOR 6 REMOTE MOTOR 7 REMOTE MOTOR 8 SECURED END DISPLAY UNSECURED TOP DISPLAY UNSECURED END DISPLAY RELAY OUTPUT COMMON N / O ENTRY ALRM RELAY OUTPUT N / O EXIT ALARM RELAY OUTPUT N / O BYPASS STATUS RELAY OUTPUT N / O WING FAULT RELAY OUTPUT NOT USED N / O VALID ENTRY CARD INPUT N / O VALID EXIT CARD INPUT N / O INVALID CARD INPUT N / O WING DISABLE-OPTICAL ONLY INPUT N / O BYPASS / FIRE ALARM INPUT 4040 FM 3 Page 7 Fax: -3-469

User Interface ANNUNCIATOR POWER VDC ANNUNCIATOR POWER COMMON ANNUNCIATOR BYPASS LED ANNUNCIATOR WINGFAULT LED ANNUNCIATOR ALARM LED ANNUNCIATOR INVALID CARD LED ANNUNCIATOR NORMAL LED ANNUNCIATOR BUTTON / KEYSWITCH ANNUNCIATOR INVALID CHIME ANNUNCIATOR ALARM BUZZER REMOTE MOTOR REMOTE MOTOR REMOTE MOTOR 3 REMOTE MOTOR 4 REMOTE MOTOR REMOTE MOTOR 6 REMOTE MOTOR 7 REMOTE MOTOR 8 SECURED END DISPLAY UNSECURED TOP DISPLAY UNSECURED END DISPLAY RELAY OUTPUT COMMON N / O ENTRY ALRM RELAY OUTPUT N / O EXIT ALARM RELAY OUTPUT N / O BYPASS STATUS RELAY OUTPUT N / O WING FAULT RELAY OUTPUT NOT USED N / O VALID ENTRY CARD INPUT N / O VALID EXIT CARD INPUT N / O INVALID CARD INPUT N / O WING DISABLE-OPTICAL ONLY INPUT N / O BYPASS / FIRE ALARM INPUT 3 4 6 7 8 9 0 3 4 6 7 8 3 4 6 7 8 3 4 6 3 4 6 7 8 9 30 Wiring required between housings for motor control. Wire provided by installing contractor. Housing with processor control. Wiring required between housings for display control. Wire provided by installing contractor. REMOTE MOTOR REMOTE MOTOR REMOTE MOTOR 3 REMOTE MOTOR 4 REMOTE MOTOR REMOTE MOTOR 6 REMOTE MOTOR 7 REMOTE MOTOR 8 3 4 6 7 8 3 4 6 7 8 SEPRATOR SEPRATOR SEPRATOR Adjacent housing terminations. SEPRATOR 4040 FM 3 Page 8 Fax: -3-469

3 4 6 7 8 9 0 3 4 6 7 8 3 4 6 7 8 3 4 6 3 4 6 7 8 9 30 ANNUNCIATOR POWER VDC ANNUNCIATOR POWER COMMON ANNUNCIATOR BYPASS LED ANNUNCIATOR WINGFAULT LED ANNUNCIATOR ALARM LED ANNUNCIATOR INVALID CARD LED ANNUNCIATOR NORMAL LED ANNUNCIATOR BUTTON / KEYSWITCH ANNUNCIATOR INVALID CHIME ANNUNCIATOR ALARM BUZZER REMOTE MOTOR REMOTE MOTOR REMOTE MOTOR 3 REMOTE MOTOR 4 REMOTE MOTOR REMOTE MOTOR 6 REMOTE MOTOR 7 REMOTE MOTOR 8 SECURED END DISPLAY UNSECURED TOP DISPLAY UNSECURED END DISPLAY RELAY OUTPUT COMMON User Interface N / O ENTRY ALRM RELAY OUTPUT N / O EXIT ALARM RELAY OUTPUT N / O BYPASS STATUS RELAY OUTPUT N / O WING FAULT RELAY OUTPUT NOT USED N / O VALID ENTRY CARD INPUT N / O VALID EXIT CARD INPUT N / O INVALID CARD INPUT N / O WING DISABLE-OPTICAL ONLY INPUT N / O BYPASS / FIRE ALARM INPUT 4040 FM 3 Page 9 Fax: -3-469

Sub-Base & Housing Installation Instructions For Optical Turnstile System. Mark squaring line on floor 3 inches back from actual location of turnstile end.. Square base to marked line, long edges perpendicular to squaring line 3. Remove top nut, lock washer, and flat washer from attached bolts. (Leaving flat washer) 4. Drill 3/8 diameter hole AT LEAST 3 inches deep in the four corner slots, and the four slots in the center of the base.. Clean out drilled holes thoroughly and hammer provided anchor bolts into holes. Tighten nuts. DO NOT SHIM SUB-BASE. ANCHOR FLAT TO THE FLOOR. 4040 FM 3 Phone: /303-033 Fax: /3-469

6. Slightly loosen lower nuts. This helps the bolts align with frame holes. 7. If the turnstile is mounted against a wall, level bolts on wall side first. To level, place level across washers and adjust top nuts as necessary. 8. Place provided blocks across subbase as shown. Blocks should be high. 9. Unbolt the steel shipping blocks from the turnstile frame. 0. Place the turnstile frame on the sub-base on top of the wooden blocks as shown. Align frame holes with the respective bolt underneath. DO NOT DAMAGE THREADS ON SUB-BASE BOLTS.. Remove the wooden blocks and set frame onto base one end at a time. DO NOT DAMAGE THREADS ON SUB-BASE BOLTS.

. Center all bolts in slots and tighten all lower nuts onto the subbase. 3. Lower the top leveling nut until it makes contact with the bottom nut. This begins the leveling process. 4. Level all four corners of stainless housing vertically.. Tighten remaining leveling nuts. Make sure not to distort the turnstile base frame. 6. Finish leveling by assembling top hardware (remaining washer, lock washer, and nut).