Section D. H-MOSS Occupancy Sensors Index. Wall Switches. Wall and Ceiling Mount. Sensors. Residential and Vacancy. Sensors

Similar documents
H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

H-MOSS. Sensors for an Energy Conscious World

H-MOSS Occupancy Sensors Control Units and Add-A-Relay

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Ever evolving energy code requirements and the large demand for energy

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

Versatile wall switch sensors maximize payback and simplify code compliance

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Mini Product Guide.

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Installation Instructions

ENERGY EFFICIENCY EXPERTS

Residential Occupancy & Vacancy Sensors

Never forget to turn the lights off again. Motion Sensors

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Innovative. Integrated. Simple.

Infrared Ceiling Mount Sensor

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

SECTION. Occupancy Sensors & Lighting Control Products

Infrared Wall Mount Occupancy Sensor

Installation Instructions

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Occupancy Sensor Selection Guide

National Grid Small Business Program Rebate Manual

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

A. This Section includes the following lighting control devices:

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

DIMMING WASP Occupancy and Daylight Sensor

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Interior Control Solutions

SECTION LIGHTING CONTROLS

CONTENTS SENSOR SWITCH

Lighting and Fan Speed Controls

0ACDT2000MV Ultasonic/Infared Occ Sensor

IN2 Lighting Control Devices

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

Maestro 0 10 V Dimmer Sensor

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

600 Watt Dimmer Install Guide

The Power To Supply... All Your Electrical Products

Maestro Dual-Circuit Occupancy Sensing Switch

Infrared Ceiling Mount Sensor

A. This Section includes the following lighting control devices:

Maestro Occupancy Sensing Switch

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Applied Lighting Controls

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Maestro Occupancy Sensing Switch

Wherever the best is needed. Sensors for professionals.

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Energy Management Products

Product Specifications Dialog Room Controller* (*patent pending)

The Power To Supply... All Your Electrical Products

VESICA LINEAR SUSPENDED VES L

Maestro Occupancy sensing switch

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

Maestro Occupancy sensing switch

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Built-in HF Sensor for High Bay

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

IP65 High Bay Dual Sense Sensor

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

LIGHTING CONTROL DEVICES

SENSA MRE DDM MR

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Emery County Senior Center Green River 06/07

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Analogue Dimming Microwave Presence/Absence Detector

East Central College

Vive PowPak Fixture Controls

SECTION LIGHTING CONTROL DEVICES

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Direct Dim Microwave Presence/Absence Detector

GE LightSweep Lighting Control System Guideform Specification

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Sensors and Detectors

IP65 High Bay Dual Sense Sensor

Integrated PIR detectors

LIGHTING CONTROLS

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

FR-A180 FR-A360. Occupancy detector. Use

Tri-level Control HF Sensor

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Incentive & Measure Specifications

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Transcription:

Section D Index Product Sensor Technology Page Smart Technologies for Smart Buildings... D-2 Energy Savings with Occupancy Sensors... D-3 Wall Switches Features and Benefits... D-4 Wall Switches with Adaptive Technology... D-5 Wall Switches with Passive Infrared Technology and Digital Timer... D-6 Residential Occupancy and Vacancy Sensors... D-7 Ceiling Sensors Features and Benefits... D-8 Ceiling Sensors with Adaptive Technology... D-9 Line Voltage and Low Voltage Ceiling Sensors... D-10 Wall Mount Sensors, Control Units and Accessories... D-11 OPTIMYZER High Bay Controls and Daylight Harvesting... D-12 Specifications and Wiring Schematics Dual Technology and Wall Switches... D-13 Passive Infrared Wall Switches... D-15 Ceiling and Wall Mount Sensors... D-17 Control Units and Add-A-Relay... D-18 Ceiling and Wall Mount Sensors... D-19 Wall Switches Wall and Ceiling Mount Sensors Residential and Vacancy Sensors High Bay and Daylight Harvesting Index www.hubbell-wiring.com D-1

Smart Technologies for Smart Buildings Smart Technologies for Smart Buildings combine innovative technologies for industry proven performance. How to Select the Right Technology for the Proper Application Dual Technology Dual technology occupancy sensors combine both passive infrared () and ultrasonic (US) technologies for maximum reliability. Because US and need to both detect occupancy to turn lighting on, dual technology sensors minimize the risk of lights coming on when the space is unoccupied false triggering. Continued detection by only one technology then keeps lighting on as necessary. Dual technology sensors offer the best performance for most applications. (US) Adaptive Technology (US) technology senses occupancy by bouncing sound waves (32 khz - 45 khz) off of objects and detecting a frequency shift between the emitted and reflected sound waves. Movement by a person or object within a space causes a shift in frequency, which the sensor interprets as occupancy. While US occupancy sensors have a limited range, they are excellent at detecting even minor motion such as typing and filing, and they do not require an unobstructed line-of-sight. This makes US technology sensors ideal for an application like an office with cubicles or a restroom with stalls. Adaptive Technology is a Hubbell breakthrough that delivers benefits to both building owners and occupants. The building owner achieves reduced energy costs, fewer adjustments and less maintenance, and the building occupant experiences fewer false-offs and disturbances. Adaptive technology occupancy sensors use microprocessors that make all the decisions for setting adjustments. Internal software constantly monitors the controlled area and automatically adjusts the sensitivity and timer based on environmental history. This means that instead of manually adjusting the sensor for seasonal changes, modified airflow, furniture layout or occupancy pattern changes, the sensor automatically adjusts itself. These automatic adjustments eliminate the need for multiple manual adjustments by maintenance personnel or outside contractors. Hubbell offers adaptive technology throughout its product offering wall switches, ceiling and wall mount sensors in conjunction with dual technology, ultrasonic and passive infrared products. Passive Infrared () Passive infrared () technology senses occupancy by detecting the movement of heat emitted from the human body against the background space. Unlike US technology, sensors require an unobstructed line-of-sight for detection. These sensors use a segmented lens, which divides the coverage area into zones. Movement between zones is then interpreted as occupancy. sensors are ideal for detecting major motion (e.g. walking), and they work best in small, enclosed spaces with high levels of occupant movement. D-2 www.hubbell-wiring.com

Energy Savings with Occupancy Sensors Typical Applications Wall Switch Ceiling Sensor Wall Sensor Applications are generalized. Consult your Hubbell representative for the type of technology and products that fit your needs. Hubbell Occupancy Sensors Play a Key Role In the U.S., lighting consumes 22% of electricity and represents $40 billion a year in energy costs. Using advanced technology, Hubbell s are doing their part to save energy and provide sustainability by automatically and effectively turning lights on when a room is occupied and off when a room is vacant. In a typical office building, where lighting accounts for 35 to 45% of energy use, H-MOSS Occupancy Sensors have the potential to reduce wasted lighting by 13 to 90% for a significant return on investment (ROI). Hubbell offers a broad range of occupancy and vacancy sensors and lighting controls that meet the latest codes and standards, including ASHRAE/IESNA 90.1 and California Energy Commission (CEC) Title 24. H-MOSS Occupancy Sensors can also provide LEED points in categories like Sustainable Sites, Energy and Atmosphere, Indoor Quality and Innovative Design Process. Backed by Hubbell Service and Support are backed by Hubbell s Wise sustainability initiative and superior service and support including: Valuable online H-MOSS ROI worksheet for calculating energy savings Detailed H-MOSS online e-learning courses that can be taken anywhere, anytime Product selection guide for choosing the right H-MOSS Occupancy Sensor and technology Online specification assistance through spec wizard, AutoCAD drawings, templates, BIM objects and documentation Comprehensive design assistance for deploying occupancy sensors in a variety of applications Highly knowledgeable network of specification professionals and trained, dedicated sales staff Backed by Hubbell who is committed to safeguarding the environment through environmental stewardship, innovative products and efficient operations Application Sensor Technology Sensor Style Adaptive Dual Wall Switch Ceiling Wall Office Small + + + Large + + + Open Office + + + Storage/ Small + + Warehouse Large + + + + Rest Room Small + + + Large + + + Conference Small + + + Room Large + + + Classroom Small + + + Large + + + Hall + + + Electrical bill impact for a typical office building* Uses 39% of Total Electricity Other 14% Refrigeration 5% Office Equipment 15% 39% Climate Control 27% Savings 16% Potential electricity bill savings** Note: * Energy Information Administration: Commercial Buildings Energy Consumption Survey ** Based on 40% lighting savings from sensors. Actual results may vary. Energy Savings with Occupancy Sensors www.hubbell-wiring.com D-3

Features and Benefits Adaptive Dual Technology Wall Switches Features and Benefits Available in ivory, white, light almond, black and gray Dual technology sensing combines the individual advantages of passive infrared and ultrasonic detection Impact resistant hard lens is standard and color matched to the switch Designed for use on 120 or 277V AC circuits. No neutral needed for fast retrofits and white models available to match office decor High density 1200 square foot coverage with color matched lens Two-color LED provides instant feedback of sensor status Front press switch allows the occupant to switch the sensor from automatic operation to momentary off mode. The sensor returns to automatic operation mode 30 minutes after the last detected motion Designed for use on 120 or 277V AC circuits. No neutral needed for fast retrofits AD1277W1 Adaptive Passive Infrared Wall Switches Features and Benefits AT1277W Adaptive technology - Install and forget operation, analyzes environment and adjusts sensitivity and timer, eliminating the need for manual adjustment Built in photocell with manual super saver mode for daylight harvesting Auto or manual On operating modes. Available in either single relay or dual relay versions for enhanced savings with bi-level switching applications Heavy-duty relay controls up to 1800 watts at 120V AC or 4155 watts at 277V AC Soft tone alert provides audible indication of sensor time-out 12 seconds prior to switching lights out Digital pushbutton ambient light level control located behind cover allows for quick, accurate setting of ambient light threshold D-4 www.hubbell-wiring.com

Wall Switches Featuring Adaptive Technology Adaptive Technology Adaptive technology - Install and forget operation All digital sensing technology Dual 120/277V AC operation. No neutral required Auto or manual On operating modes No minimum load requirements Hard lens (dual technology, passive infrared) Dual ( and Passive Infrared) 1000 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC, 50/60Hz Description Single Circuit; 1 Button for manual/auto control AD1277I1 AD1277W1 Single Circuit; Auto control with no button AD1277I1N AD1277W1N Dual Circuit; 2 Buttons for manual/auto control AD1277I2 AD1277W2 Dual Circuit; Auto control with no button AD1277I2N AD1277W2N 400 square foot coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC, 50/60Hz Description Single Circuit; 1 Button for manual/auto control AU1277I1 AU1277W1 Single Circuit; Auto control with no button AU1277I1N AU1277W1N Dual Circuit; 2 Buttons for manual/auto control AU1277I2 AU1277W2 Dual Circuit; Auto control with no button AU1277I2N AU1277W2N Passive Infrared 1000 sq. ft. coverage with photocell, 800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC, 50/60Hz Description Single Circuit; 1 Button for manual/auto control AP1277I1 AP1277W1 Single Circuit; Auto control with no button AP1277I1N AP1277W1N Dual Circuit; 2 Buttons for manual/auto control AP1277I2 AP1277W2 Dual Circuit; Auto control with no button AP1277I2N AP1277W2N Note: Sensors are also available in: LA (Light Almond), GY (Gray) or BK (). These colors have minimum lead times. Please call Customer Service for further information. Wallplates are sold separately. Coverage Patterns Minor Motion: 26' 21' 28' 28' 50' Major Motion: 29' 24' 14.5' 14.5' Zero arc point switching Built in photocell with manual super saver mode for daylight harvesting Bi-level switching or dual load control (AD, AP AU1277x2, 2N series) culus, CEC Title 24 Certified 26' 21' AD1277W1 AU1277W1 AP1277W1 AD1277 Series AU1277 Series AP1277 Series 24' 28' 28' 50' AD1277W1N AD1277W2N AU1277W2 AP1277W2 Wall Switches with Adaptive Technology www.hubbell-wiring.com D-5

Wall Switches and Digital Timer with Passive Infrared Technology Wall Switches and Digital Timer Featuring Passive Infrared Technology AT1277W WS1277W WS1277W2 10' (3.0m) ATP1277W WS120W DT1277W Coverage Patterns Minor Motion: 20' (6.1m) 14.5" (36.8cm) Mounting Height 42" to 54" (106.7 to 137.2cm) Vertical Coverage AT1277, ATP1277 Major Motion: 29" (73.3cm) 3.5º 3.5º See Horizontal View for Range Adaptive Technology, Passive Infrared Adaptive technology - Install and forget operation Passive infrared technology Dual 120/277V AC operation, no neutral required Heavy duty relay (AT1277) Description Coverage 120V AC 277V AC Color One button; 120/277V AC 1200 sq. ft. 800W 1200W WS1277I WS1277W One button; 120V AC One button; 277V AC Double pole; 120/277V AC 16' 16' 900 sq. ft. 800W Incandescent 1000W Fluorescent 40' 16' 16' N/A 900 sq. ft. N/A 1800W Fluorescent 1000 sq. ft. 600W Incandescent* 1000W Fluorescent* *per circuit 1800W Fluorescent Two-gang adapter wallplate for WS1277W2 to mount to a 2-gang box. Audible alarm before turning lights off (AT1277) 1200 sq. ft. coverage Built in photocell for daylight harvesting Nylon wallplate included culus, CEC Title 24 Certified Description 120V AC 277V AC Color One Button 1800W Incandescent 4155W Fluorescent AT1277I AT1277W One Button 800W Incandescent 800W Fluorescent Passive Infrared Wall Switches Passive infrared technology Manual adjustment time delay (WS1277-20 sec. to 30 min.) (WS120/WS277-30 sec. to 30 min.) Photocell (WS1277I, WS1277W) Digital Timer Wall Switch AT1277, ATP1277, WS1277 1200W Fluorescent 35' WS120, WS277 Gray Bi-level switching (WS1277W2) Wallplate included No neutral required culus, CEC Title 24 Certified 36' 36' ATP1277I ATP1277W ATP1277GY WS120I WS120W WS277I WS277W WS1277W2 WSAP Description 120V AC 277V AC Color Dip switch enabled preset intervals - 5,15 or 30 minutes - 1, 3, 6, 9 or 12 hours Includes an on/off momentary push button switch feature 800W 1200W DT1277W 36' WS1277W2 D-6 www.hubbell-wiring.com

Wall Switches Residential Occupancy and Vacancy Sensors Residential Occupancy Sensors - Passive Infrared Passive infrared technology. No neutral required Photocell equipped for daylight harvesting Auto-on, auto-off Time delay adjustment, 30 seconds to 30 minutes Description Coverage 120V AC 277V AC Color Switch with button; N/A 150 view Switch with dimming; 150 view Heavy duty switch; 180 view Coverage Patterns Minor Motion: 14' 14' 800 sq. ft. 500W Incandescent only 800 sq. ft. 500W Incandescent only 900 sq. ft. 800W Incandescent 1000W Fluorescent Vacancy Sensors - Passive Infrared Passive infrared technology. No neutral required Manual-on, auto-off Patent pending alert to off dims lights prior to going off (RMS100 & 120) Major Motion: N/A 1800W Fluorescent Mounting Height 36" to 54" (91.44 to 137.16 cm) 35' 35' Horizontal Coverage Vertical Coverage RMS101, RMS121, RMS100, RMS120 5 5 Almond Lt. Almond Almond Lt. Almond Almond Description Coverage 120V AC 277V AC Color Switch with button; N/A 150 view Switch with dimming; 150 view Heavy duty switch; 180 view 800 sq. ft. 500W Incandescent only 800 sq. ft. 500W Incandescent only 900 sq. ft. 800W Incandescent 1000W Fluorescent N/A 1800W Fluorescent Patent pending alert to off dims lights prior to going off (RMS101&121) Wallplate included culus Almond Lt. Almond 16' 16' Standard Nightlight RMS101I RMS101ILI RMS101W RMS101ILW RMS101AL RMS101ILAL RMS101LA RMS101ILLA RMS121I RMS121W RMS121AL RMS121LA RMS141I RMS141W RMS141AL Time delay adjustment, 30 seconds to 30 minutes Wallplate included culus, CEC Title 24 Certified Almond Lt. Almond Almond RMS121ILI RMS121ILW RMS121ILAL RMS121ILLA Standard Nightlight RMS100I RMS100W RMS100AL RMS100LA RMS120I RMS120W RMS120AL RMS120LA RMS140I RMS140W RMS140AL RMS100ILI RMS100ILW RMS100ILAL RMS100ILLA RMS120ILI RMS120ILW RMS120ILAL RMS120ILLA RMS101W RMS121ILW RMS100W RMS120ILW RMS121W RMS141W RMS120W RMS140W 15 15 Mounting Height 36" to 54" (91.44 to 137.16 cm) 35' 35' Horizontal Coverage Vertical Coverage RMS141, RMS140 Residential Occupancy and Vacancy Sensors www.hubbell-wiring.com D-7

Features and Benefits Adaptive Technology Ceiling Sensors Features and Benefits LED indicates passive infrared detection Digital, crystal controlled ultrasonic transmitter and receiver for coverage in each direction for superior sensing of motion Off-white ABS enclosure blends with ceiling tile Dual technology sensing combines the individual advantages of passive infrared and ultrasonic detection 110 coverage provides complete room sensing when corner mounted Isolated relay included on sensors with "RP" suffix for interfacing with auxiliary systems such as HVAC ATD2000C Dual element passive-infrared detector and lens sense heat in motion Adaptive Technology Wall Mount Sensors Features and Benefits ATD1600W LED indicates ultrasonic detection Isolated relay included on sensors with RP suffix for interfacing sensor to auxiliary systems such as HVAC Ambient light level control featured on sensors with RP suffix to prevent unnecessary lighting usage when natural light is sufficient Swivel mounting bracket allows sensor to be easily adjusted in ceiling or wall mount applications LED indicates ultrasonic detection LED indicates passive infrared detection Ambient light level control featured on sensors with RP suffix to prevent unnecessary lighting usage when natural light is sufficient D-8 www.hubbell-wiring.com

H-MOSS Occupancy Sensors H-MOSS Occupancy Sensors Ceiling Sensors Featuring Adaptive Technology Adaptive Technology Adaptive Technology- Install and forget All digital sensing technology Photocell for daylight harvesting and relay to interface with auxiliary systems such as HVAC (CRP models) Mounting base included with sensor Non-volatile memory settings retained after power outage 24V DC, 33mA 32kHz (ATD/ATU500C & CRP - 40kHz) culus, CEC Title 24 Certified Dual ( and Passive Infrared) Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared () long-range major motion detection Coverage Color 2000 sq. ft. with photocell and isolated relay 2000 sq. ft. 1000 sq. ft. with photocell and isolated relay 1000 sq. ft. 500 sq. ft. with photocell and isolated relay 500 sq. ft. ATD2000CRP ATD2000C ATD1000CRP ATD1000C ATD500CRP ATD500C ATD2000C Series ATD1000C/ ATD500C Series ATU2000C Series ATU1000C/ ATU500C Series Note: All ATD ceiling sensors must use a CU series control units. See page D-11 for details. Excellent minor motion detection Coverage Color 2000 sq. ft. with photocell and isolated relay 2000 sq. ft. 1000 sq. ft. with photocell and isolated relay 1000 sq. ft. 500 sq. ft. with photocell and isolated relay 500 sq. ft. ATU2000CRP ATU2000C ATU1000CRP ATU1000C ATU500CRP ATU500C Note: All ATU ceiling sensors must use a CU series control units. See page D-11 for details. Passive Infrared Outstanding long range major motion detection Coverage Color Wide view lens Wide view lens High density lens High density lens 1500 sq. ft. with photocell and isolated relay 1500 sq. ft. 450 sq. ft. with photocell and isolated relay 450 sq. ft. ATP1500CRP ATP1500C ATP600CRP ATP600C ATP1500C/ ATP600C Series Note: All ATP ceiling sensors must use a CU series control units. See page D-11 for details. Coverage Patterns Minor Motion: Major Motion: 22' 12' 12' 32' 22' 12' 32' 45' 20' 64' ATD2000C Series 45' 64' 32' 45' 32' ATD500C Series 11' 7' 18' 32' 20' 14' ATP1500C Series ATU1000C Series www.hubbell-wiring.com ATP600C Series 32' 26' 64' 16' ATU2000C Series 12' 18' 26' 64' 32' 32' 22' 14' 32' ATD1000C Series 22' 64' 16' ATU500C Series ATU2000C Series Hallway Application D-9 Ceiling Sensors with Adaptive Technology Description

Line Voltage and Low Voltage Ceiling Sensors Ceiling Sensors Line Voltage and Low Voltage LVDT2000R120 LVUS1500R120 LVUS2000R120 LVPR1500R LVPR1500RP Coverage Patterns Minor Motion: 34' 34' 38' 42' LVDT2000R Series Line Voltage Ceiling Sensors Adjustable Time Delay/Sensitivity Self Contained Power Supply uced Installation Time Low Voltage Ceiling Sensor Adjustable Time Delay/Sensitivity Integral photocell control for Daylight Harvesting Passive Infrared () Outstanding long range major motion detection Connect to Existing Line Voltage Circuits culus, CEC Title 24 Certified Dual Technology Passive Infrared/ Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared () long-range major motion detection Voltage Coverage Load Rating Color 120V AC 277V AC Excellent minor motion detection. 32.7kHz operating frequency Voltage Coverage Load Rating Color 120V AC 277V AC 120V AC 277V AC Passive Infrared () Outstanding long range major motion detection in a compact low profile housing Voltage Coverage Load Rating Color 120-347V AC with photocell and isolated relay 1500 sq. ft. 800W Inc. 1000W Fl. @ 120V AC 1800W Fl. @ 277V AC 2200W Fl. @ 347V AC LVPR1500R Compact Low Profile Minimizes Visual Impact Integrates into Building Automation Systems Description Coverage Color With Relay isolated relay 1500 sq. ft. LVPR1500RP Note: For use with building automation and HVAC systems, power with 24V DC from Hubbell CU series control units. See page D-11 for details. 40' 48' 38' Major Motion: 63' 2000 sq. ft. 2000 sq. ft. 2000 sq. ft. 2000 sq. ft. 1500 sq. ft. 1500 sq. ft. LVUS2000R Series 2400W 5000W 2400W 5000W 2400W 5000W 40' 46' LVUS1500R Series 20' LVDT2000R120 LVDT2000R277 LVUS2000R120 LVUS2000R277 LVUS1500R120 LVUS1500R277 LVPR1500R(P) D-10 www.hubbell-wiring.com

Wall Mount Sensors, Control Units and Accessories Adaptive Technology Wall Mount Sensors Adaptive Technology - Install and forget operation Swivel mounting bracket included for wall or ceiling mounting All digital sensing technology Accessories Control Units The CU300A provides a 24V DC power supply for 1 to 4 sensors or sensor/add-a-relay combinations or 1 to 3 for CU347A. The control units contain an internal relay for the control of an external lighting load. Control units are plenum rated culus Listed. Description 120/277V AC, 50/60 Hz for use with ATD, ATU and ATP series ceiling/wall mount sensors CU300A Same as CU300A above, manufactured in U.S.A. CU300AU 347V AC, 60 Hz, for use with ATD, ATU and ATP series ceiling and wall mount sensors CU347A Add-A-Relay Hubbell AAR Add-A-Relay contains an internal relay for control of an external lighting load. The AAR requires a 24V DC power supply from the Hubbell CU series control unit. The AAR is typically used when: 1. It is desired to switch more than one circuit when occupancy is sensed. 2. The lighting load exceeds the maximum rating of the control unit. Description For use with CU series control units and Hubbell ATD, ATU and ATP series ceiling and wall mount sensors Coverage Patterns 32' 32' 20' 40' ATD1600W Series 20' 40' ATP1600W Series Photocell for daylight harvesting and relay interface with auxiliary systems such as HVAC (RP models) 24V DC, 33MA culus, CEC Title 24 Certified Dual ( and Passive Infrared) Description Coverage Color 32kHz, with photocell and isolated relay 32kHz 1600 sq. ft. 1600 sq. ft. 7' 7' 30 20 10 0 120' ATP120HB Series Top View 120' Side View ATD1600WRP ATD1600W Passive Infrared Description Coverage Color With photocell and isolated relay 1600 sq. ft. 1600 sq. ft. ATP1600WRP ATP1600W For aisle and high bay applications, 120 linear ft. ATP120HBRP with photocell and isolated relay For aisle and high bay applications 120 linear ft. ATP120HB Note: All wall mount sensors must use a CU series control units. See below for details. AAR Ceiling Accessories Wall Mount and Switch Accessories Description Description Ceiling Sensor Infrared NEMA 4X Enclosure Ceiling Mount Wire Guard Ceiling Mount Raceway Adapter ACIPE ACMG ACMRA Wall Switch Wire Guard Wall Mount Wire Guard AWSG AWMG Minor Motion: Major Motion: ATD1600W Series ATP1600W, ATP120HB Series CU347A, CU300A AAR ACIPE AWSG ACMG AWMG Wall Mount Sensors, Control Units and Accessories www.hubbell-wiring.com D-11

Daylight Harvesting and High Bay Controls OPTIMYZER High Bay Controls and Daylight Harvesting HMHB21U DHADC DHIP, DHOP DHAP, DHSP DHCM OPTIMYZER High Bay Controls Digital passive infrared () sensor Multiple (single and dual) output versions Single and dual timer operation Low-profile design Daylight Harvesting Multiple calibration options Selectable 3- or 8-second dimming rate Supports mounting heights up to 40 ft. Area and aisle coverage Universal voltage (120/277/347V AC) models available No minimum load Standard Description Voltage Fluorescent High Bay Sensor, 1 Relay 120-347V AC HMHB21U Fluorescent High Bay Sensor, 2 Relays 120-347V AC HMHB22U Fluorescent High Bay Sensor, 1 Double Pole Relay 208, 240V AC HMHB23A Fluorescent High Bay Sensor, 1 Double Pole Relay 480V AC HMHB23B Fluorescent High Bay Sensor 24V DC HMHB2LV* Daylight Harvesting (With Photocells) Description Voltage Fluorescent High Bay Sensor, 1 Relay with Photocell 120-347V AC HMHB21UP Fluorescent High Bay Sensor, 2 Relays with Photocell 120-347V AC HMHB22UP Fluorescent High Bay Sensor, 1 Double Pole Relay 208, 240V AC HMHB23AP with Photocell Fluorescent High Bay Sensor, 1 Double Pole Relay 480V AC HMHB23BP with Photocell Fluorescent High Bay Sensor with Photocell 24V DC HMHB2LVP* Low Temperature (-40 F, -40 C Min) Description Voltage Fluorescent High Bay Low Temp. Sensor, 1 Relay 120-347V AC HMHB21UC No Photocell Fluorescent High Bay Low Temp. Sensor, 1 Relay 120-347V AC HMHB21UPC with Photocell Fluorescent High Bay Low Temp. Sensor, 2 Relays 120-347V AC HMHB22UC Fluorescent High Bay Low Temp. Sensor, 2 Relays 120-347V AC HMHB22UPC with Photocell Fluorescent High Bay Low Temp. Sensor, 1 Double Pole Relay 208, 240V AC HMHB23AC Fluorescent High Bay Low Temp. Sensor, 1 Double Pole Relay 208, 240V AC HMHB23APC with Photocell Fluorescent High Bay Low Temp. Sensor, 1 Double Pole Relay 480V AC HMHB23BC Fluorescent High Bay Low Temp. Sensor, 1 Double Pole Relay 480V AC HMHB23BPC with Photocell Fluorescent High Bay Low Temp. Sensor 24V DC HMHB2LVC* Fluorescent High Bay Low Temp. Sensor with Photocell 24V DC HMHB2LVPC* Accessories Description High Bay Mounting Extension Adapter External Daylight Control HMHBSA HMHBEP Low-profile design Light-sensitivity range of 0 500 foot-candles Description Voltage Single Zone Continuous Automatic Dimming Control Indoor Photocell Outdoor Photocell Atrium Photocell Skylight Photocell Control Module 10V DC 24V DC 24V DC 24V DC 24V DC 24V DC DHADC DHIP DHOP DHAP DHSP DHCM Note: * For use with CU series control units. See page D-11 for details. For use with 0-10V DC dimming ballasts. For use with DHCM and CU series control units. D-12 www.hubbell-wiring.com

Specifications and Wiring Schematics Dual Technology and Wall Switches Adaptive Dual Technology Wall Switch AD1277 Series Wall Switches Electrical AD1277 Series Power Supply 120/277V AC, 50/60Hz. Load Capacity Incandescent 0 to 800 watts. 120V AC Ballast 0 to 1000 watts. 277V AC Ballast 0 to 1800 watts. Agency Approvals culus Listed. High impact plastic (UL-94-5V). Lens Dual element pyrometer and 12 element cylindrical hard lens. Dimensions Face 2.59"H x 1.73"W, 0.37"D (from wall out). Mounting Height 42 to 54 inches above floor. Operating 32 F to 104 F (0 C to 40 C); 0% to 95% non-condensing relative humidity. Controls Time Delay Digital, adaptive 4 to 30 minutes. Ambient Light Adjustable ambient light override, 10 to 500 foot candles. Front Press Switch Auto/Off. Sensitivity Adaptive 0% to 100%. Service Switch Air gap off. Sensing Indicator Passive Infrared LED. LED. Wiring Schematic AD, AU, AP, 1277 Series Wall Switch Sensors 120/277 VAC Ground Ground Hot Load 1 Line circuit 1 120/277 VAC Ground Line circuit 2 120/277 VAC Load A Violet Adaptive Technology and Passive Infrared Wall Switches AP1277 and AU1277 Series Wall Switches Electrical AP1277 Series, AU1277 Series Power Supply 120/277V AC, 50/60Hz. Load Capacity Incandescent 0 to 800 watts. 120V AC Ballast 0 to 1000 watts. 277V AC Ballast 0 to 1800 watts. Agency Approvals culus Listed. High impact plastic (UL-94-5V). Lens Dual element pyrometer and 12 element cylindrical hard lens (AP1277 only). Dimensions Face 2.59"H x 1.73"W, 0.37"D (from wall out). Mounting Height 42 to 54 inches above floor. Operating 32 F to 104 F (0 C to 40 C); 0% to 95% non-condensing relative humidity. Controls Time Delay Load 1 Load 2 Ground Hot Digital, adaptive 4 to 30 minutes. 20 minutes default. Ambient Light Adjustable ambient light override, 10 to 500 foot candles. Front Press Switch Auto/Off. Sensitivity Adaptive 0% to 100%. Service Switch Air gap off. Sensing Indicator Passive Infrared LED (AP1277 only). LED (AU1277 only). Single Circuit Wiring Dual Circuit Sensor, Wired for Dual Circuits Dual Circuit Sensor, Wired for Single Circuit Single Circuit Sensors, Wired as 3-Way Sensors* Note: * Load can not exceed the rating of one switch. Sensor is shipped with all dip switches in the OFF position (factory default). Line circuit 120/277 VAC Ground Violet Load 1 Violet Load 2 Dual Circuit Sensors, Wired as 3-Way Sensors* Load A Load B Specifications and Wiring Schematics www.hubbell-wiring.com D-13

Specifications and Wiring Schematics Specifications and Wiring Schematics Passive Infrared Wall Switches Adaptive Technology Wall Switch AT1277 Series Wall Switches Electrical AT1277 Series Power Supply 120/277V AC, 50/60Hz. Load Capacity 120V AC 0 to 1800 watts. 277V AC 0 to 4155 watts. Agency Approvals UL Listed, culus Certified. Flame retardant UL 94 V-0 ABS. Lens Polyethylene. Dimensions Face 2.61"H x 1.29"W, 0.73"D (from wall out). Mounting Height 42 to 54 inches above floor. Operating 32 F to 122 F (0 C to 50 C) with rate of change not exceeding 20 F (11 C) per hour; 20% to 90% noncondensing relative humidity. Storage -20 F to 150 F (-29 C to 65 C); 20% to 90% non condensing relative humidity. Controls Time Delay Digital, test (15 seconds), Adaptive 5 to 30 minutes. Ambient Light Digital, pushbutton, 30 to 300 foot candles. Front Press Switch Auto/Momentary Off (30 minutes after last motion, switch returns to automatic mode). Service Switch Auto/Off. Sensing Indicators Passive Infrared 2-color LED (red, green). Wiring Schematic AT1277, ATP1277 and WS1277 Series Wall Switches Normal Wiring Hot (Load) (Line) Load Adaptive Technology Wall Switch ATP1277 and WS1277 Series Wall Switches Electrical ATP1277 Series, WS1277 Series Power Supply 120/277V AC, 60Hz. Load Capacity Incandescent 0 to 800 watts. 120V Ballast 0 to 800 watts. 277V Ballast 0 to 1200 watts. Agency Approvals UL Listed, culus Certified. Flame retardant UL 94 V-0 ABS. Lens Polyethylene. Dimensions Face 2.61"H x 1.29"W, 0.73"D (from wall out). Mounting Height 42 to 54 inches above floor. Operating 32 F to 122 F (0 C to 50 C) with rate of change not exceeding 20 F (11 C) per hour; 20% to 90% noncondensing relative humidity. Storage -40 F to 150 F (-40 C to 65 C); 20% to 90% non condensing relative humidity. Controls Time Delay ATP1277 Series Digital, test (20 seconds), Adaptive 5 to 30 minutes. WS1277 Series Manual 20 seconds to 30 minutes. Ambient Light Digital, pushbutton, 30 to 300 foot candles. Front Press Switch Auto/Momentary Off (30 minutes after last motion, switch returns to automatic mode). Service Switch Auto/Off. Sensing Indicators Passive Infrared LED. Sensors Wired as 3-Way Sensors* Hot (Line) (Load) (Line) (Load) Note: * Load can not exceed the rating of one switch. Load D-14 www.hubbell-wiring.com

Specifications and Wiring Schematics Passive Infrared Wall Switches Passive Infrared Wall Switches RMS100, RMS101, RMS100IL, RMS101IL, RMS120, RMS121, RMS120IL, and RMS121IL Electrical Power Supply 120V AC, 60Hz. Load Capacity Incandescent 25 to 500 watts. Agency Approvals UL Listed, culus Listed. Lens Dimensions Mounting Height Operating Storage Wiring Schematic RMS100, RMS101, RMS100IL, RMS101IL, RMS120, RMS121, RMS120IL, RMS121IL, RMS140, and RMS141 Series Wall Switches Normal Wiring Hot High-impact ABS. Polyethylene. Face 2.6"H x 1.3"W, 0.40"D (from wall out). 42 to 54 inches above floor. 32 F to 122 F (0 C to 50 C) with rate of change not exceeding 20 F (11 C) per hour; 20% to 90% non condensing relative humidity. -23 F to 150 F (-10 C to 65 C); 20% to 90% non condensing relative humidity. Controls Time Delay 30 seconds to 30 minutes. Front Press Switch Auto/Off. Manual Override 50% Dim Down Lights dim to 50% 30 seconds prior to switching off. Sensing Indicator Passive Infrared LED. (Load) (Line) Load Passive Infrared Wall Switch for Dual Level RMS140 and RMS141 Electrical Power Supply 120/277V AC, 50/60Hz, ¹ ₆ HP. Load Capacity Incandescent 800 watts. 120V Ballast 0 to 1000 watts each fluorescent circuit. 277V Ballast 0 to 1800 watts each fluorescent circuit. Agency Approvals UL Listed, culus Certified. High-impact ABS. Lens Polyethylene. Dimensions Face 2.6"H x 1.3"W, 0.36" (from wall out). Mounting Height 42 to 54 inches above floor. Operating 32 F to 122 F (0 C to 50 C) with rate of change not exceeding 20 F (11 C) per hour; 0% to 95% non condensing relative humidity. Storage -23 F to 150 F (-10 C to 65 C); 20% to 90% non condensing relative humidity. Controls Time Delay 30 seconds to 30 minutes. Front Rocker Switches (two) Auto/Off. Manual Override Sensing Indicator Passive Infrared Wiring Schematic RMS140 and RMS141 Series Wall Switches Sensors Wired as 3-Way Sensors* Hot (Line) (Load) LED. (Line) (Load) Note: * Load can not exceed the rating of one switch. Load Specifications and Wiring Schematics www.hubbell-wiring.com D-15

Specifications and Wiring Schematics Specifications and Wiring Schematics Passive Infrared Wall Switches Passive Infrared Wall Switches WS120I, WS120W, WS277I, WS277W Electrical WS120I, WS120W WS277I, WS277W Power Supply 120V AC, 60Hz. 277V AC, 60Hz. Load Capacity Incandescent 0 to 800 watts. NA 120V Ballast 0 to 1000 watts. NA 277V Ballast NA 0 to 1800 watts. Agency Approvals UL Listed, culus Certified. UL Listed, culus Certified. Lens Dimensions Mounting Height Operating Storage Controls Time Delay Front Press Switch Sensing Indicator Passive Infrared WS120I, WS120W, WS277I, WS277W High-impact ABS Polyethylene Face 2.6"H x 1.3"W, 0.51"D (from wall out). 42 to 54 inches above floor. 32 F to 122 F (0 C to 50 C) with rate of change not exceeding 20 F (11 C) per hour; 20% to 90% noncondensing relative humidity. -40 F to 150 F (-40 C to 65 C); 20% to 90% noncondensing relative humidity. 30 seconds to 30 minutes. Auto/Off. LED. Passive Infrared Wall Switch for Dual Level WS1277W2 Electrical Power Supply Load Capacity Incandescent 120V Ballast 277V Ballast Agency Approvals Lens Dimensions Mounting Height Operating Storage WS1277W2 120/277V AC, 60Hz. 0 to 600 watts each circuit. 0 to 1000 watts each circuit. 0 to 1800 watts each circuit. UL Listed, culus Certified. High-impact ABS Polyethylene Face 4.54"H x 2.79"W, 0.95" (from wall out). 42 to 54 inches above floor. 32 F to 122 F (0 C to 50 C) with rate of change not exceeding 20 F (11 C) per hour; 20% to 90% noncondensing relative humidity. -40 F to 150 F (-40 C to 65 C); 20% to 90% noncondensing relative humidity. Controls Time Delay 3 to 30 minutes. Front Rocker Switches (two) Auto/Off. Manual Override Bypass Override ON key provided. Sensing Indicator Passive Infrared LED. Wiring Schematic WS120 and WS277 Series Wall Switches Normal Wiring Dual Level Switching of a Single Circuit Line (Hot) Line (Hot) Circuit #2 Hot (Load) SW-1 SW-2 WS1277W2 Violet Dual Level Switching of Two Circuits Line (Hot) Circuit #1 SW-1 SW-2 WS1277W2 (Line) Sensors Wired as 3-Way Sensors* Hot (Line) (Load) Wiring Schematic WS1277W2 Wall Switch Violet (Line) (Load) Note: * Load can not exceed the rating of one switch. Load #1 Load #2 Load #1 Load #2 Load Load D-16 www.hubbell-wiring.com

Specifications Ceiling and Wall Mount Sensors Adaptive Dual Technology, and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU, ATP Series Electrical Power Requirements 24V DC nominal, 33mA from Hubbell CU series control unit. Isolated Relay Normally open and normally closed. (sensors with RP suffix) Terminals available. Agency Approvals UL Listed. Ceiling Sensors Flame retardant UL 94 V-0 ABS. Lens Polyethylene. Dimensions 1.5"H x 4.5"D. Color Office white. Mounting Height 8 to 12 feet. Wall Mount Sensors Flame retardant UL 94 V-0 ABS. Lens Polyethylene. Dimensions 6"H x 2"W x 1.5"D. Color Office white. Mounting Height 8 to 12 feet, 8 to 30 feet (ATP120HB series). Operating 32 F to 104 F (0 C to 40 C) with rate of change not exceeding 20 F (11 C) per hour; 0% to 95% non condensing relative humidity. Storage -20 F to 150 F (-29 C to 65 C); 0% to 95% non-condensing relative humidity. Controls Time Delay Test (8 seconds), adaptive 8 to 40 minutes. Ambient Light 1 to 1000 foot candles. Sensitivity Adaptive 0 to 100%. Sensing Indicators (ATD and ATU Series) LED. Passive Infrared (ATD and ATP Series) LED. High Bay Specifications HMHB21U, HMHB22U Electrical Power Requirements Line voltage units: 120/277/347V AC, 60Hz. Load Capacity 120V AC: 0 800W ballast or tungsten 277V AC: 0 1,200W ballast 347V AC: 0 1,500W ballast ¼-HP motor load Agency Approvals ETL, Conforms to UL STD 916, Certified to CAN/USA STD 22.2 No. 61010-1-04 and Title 24 Compliant. Casing High-impact injection-molded plastic. Size 4.4 inch x 3.6 inch x 2.0 inch. Weight 7 oz. Color. Mounting Fixture mount. Operating Indoor use only. 32 F to 104 F (0 C to 40 C) with rate of change not exceeding 20 F (11 C) per hour; 0% to 95% noncondensing relative humidity. Storage -20 F to 150 F (-29 C to 65 C); 0% to 95% non-condensing relative humidity. Controls Time Delay Primary: Secondary: 8-second test mode 4, 8, 16 and 30 minute time-outs Can be disabled 30, 60 and 90 minute time-outs R1 R2 H = 0' to 30' R1 = 1.4 x H H = 30' to 45' R2 = 1.1 x H Specifications www.hubbell-wiring.com D-17

Specifications Specifications Control Units and Add-A-Relay CU Series Control Units CU300A(U) and CU347A Electrical CU300A(U) CU347A Power Supply 120 to 277V AC, 50/60Hz. 347V AC, 60Hz. Power Output 24V DC, 150mA. 24V DC, 100mA. Load Capacity Incandescent 0 to 1800 watts. NA 120V Ballast 0 to 2400 watts. NA 230V Ballast NA NA 277V Ballast 0 to 5540 watts. NA 347V Ballast NA 0 to 5205 watts. AT Sensor/AAR Capacity 1 to 4 combined. 1 to 3 combined. Agency Approvals UL Listed, culus Certified. UL Listed, culus Certified. All CU Series Control Units Flame retardant UL 94-5V thermoplastic. Dimensions 3.69"L x 2.33"W x 1.36"H. Color. Operating 32 F to 104 F (0 C to 40 C); 0% to 90% non condensing relative humidity. Storage -20 F to 150 F (-29 C to 65 C); 0% to 90% non condensing relative humidity. Add-A-Relay AAR Electrical Power Input Load Capacity Incandescent 120V Ballast 230V Ballast 277V Ballast 347V Ballast Agency Approvals Dimensions Color Operating Storage 24V DC nominal, 33mA from Hubbell CU series control unit. 0 to 1800 watts. 0 to 2400 watts. 0 to 3680 watts. 0 to 5540 watts. 0 to 5205 watts. UL Listed. Flame retardant UL 94-5V thermoplastic. 3.69"L x 2.33"W x 1.36"H.. 32 F to 104 F (0 C to 40 C); 0% to 90% non condensing relative humidity. -20 F to 150 F (-29 C to 65 C); 0% to 90% non condensing relative humidity. D-18 www.hubbell-wiring.com

Wiring Schematics Ceiling and Wall Mount Sensors Adaptive Dual Technology,, and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU and ATP Series Single Circuit Application: 1 to 4 sensors wired to control unit with optional override off switch. N H CU Series Control Unit (Specify Voltage) Switch* Load * Optional Override Off Switch Circuit 1 N H Circuit 2 N H Load Load CU Series Control Unit (Specify Voltage) AAR Add-A-Relay ATD, ATU and ATP Series Sensors** Two Circuit Application: 1 to 4 sensors wired to control unit and Add-A-Relay (control unit switches circuit 1, Add-A-Relay switches circuit 2). ATD, ATU and ATP Series Sensors** Note: ** For wiring sensors with isolated relay and photocell option (models with RP suffix): Photocell Option: Cap off sensor wire. Connect Grey sensor wire to control unit wire. Isolated Relay Option: Common-/ wire, Normally Closed-/ wire, Normally Open-Yellow/ wire. Single Circuit Application: Two control units wired in parallel to operate 5 to 8 sensors in a single zone. Maximum 4 sensors per control unit any sensor will activate lighting. N H CU Series Control Unit (Specify Voltage) Circuit 1 N H Circuit 2 N H Load CU Series Control Unit (Specify Voltage) Load (+24V) (+24V) CU Series Control Unit (Specify Voltage) Load CU Series Control Unit (Specify Voltage) Load (+24V) (+24V) ATD, ATU and ATP Series Sensors** Two Circuit Application: Two control units wired in two circuits to operate 2 to 8 sensors in a single zone. Maximum 4 sensors per control unit any sensor will activate both lighting loads. ATD, ATU and ATP Series Sensors** Wiring Schematics www.hubbell-wiring.com D-19

Wiring Schematics Wiring Schematics Ceiling and Wall Mount Sensors Adaptive Technology Dual,, and Passive Infrared Ceiling and Wall Mount Sensors ATD, ATU and ATP Series Single Circuit, Dual Level Switching Application: 1 to 4 sensors wired to control unit with optional override off switches. CU Series Control Unit (Specify Voltage) ATD, ATU and ATP Series Sensors** H Single Pole Switch Single Pole Switch N Multi-Circuit Application: 1 to 4 sensors wired to control unit that is wired to a multi-pole lighting contactor. N H CU Series Control Unit (Specify Voltage) Contactor C Multipole, Normally Open contactor to be supplied by Contractor (+24V) Outboard Ballast Inboard Ballast ATD, ATU, ATP, Series Sensors** Note: ** For wiring sensors with isolated relay and photocell option (models with RP suffix): Photocell Option: Cap off sensor wire. Connect Gray sensor wire to control unit wire. Isolated Relay Option: Common-/ wire, Normally Closed-/ wire, Normally Open-Yellow/ wire. Single Circuit, 3-Way Switching Application: 1 to 4 sensors wired to control unit with optional override off switches. CU Series Control Unit (Specify Voltage) ATD, ATU and ATP Series Sensors** CU Series Control Unit (Specify Voltage) ATD, ATU and ATP Series Sensors** H H 3-Way Switch 3-Way Switch N N Traveler Traveler Traveler Traveler Load 4-Way Switch Traveler 3-Way Switch Single Circuit, 4-Way Switching Application: 1 to 4 sensors wired to control unit with optional override off switches. 3-Way Switch Load D-20 www.hubbell-wiring.com