Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

Similar documents
PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

Pepperl+Fuchs GmbH Lilienthalstrasse Mannheim Germany

operational excellence Solutions for

Installing Foundation Fieldbus in Hazardous Areas. Understanding your Options and How to Use Them

Two global companies, one solution.

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

Fieldbus Foundation TM Bus diagnostics and troubleshooting

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac- Carriers Type Universal

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

Segment design & and Bus Diagnostics

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

Foundation Fieldbus Usability from field Device Perspective. Hemal Desai Endress+Hauser India Pvt. Ltd 16 th October 2014 Automation 2014 Mumbai

Assembly. Host Sub-D Alarm

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Instrumentation Products and Applications

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Temperature Measurement Transmitters for field mounting

Model 144H. Product Data Sheet , Rev DB February Content

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Figure 1 DirectLine DL423 Sensor. Description, continued

Practical Distributed Control Systems (DCS) for Engineers & Technicians. Contents

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

2015 Honeywell Users Group Europe, Middle East and Africa

Rosemount 848T High Density Temperature Measurement Family

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

Safety Instrumented Systems

RAYCHEM NGC-30 COMPONENTS

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Dräger Polytron 7000 Fixed gas detector

Rosemount 3051CFC Compact Flowmeter

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

Rosemount 3144P Temperature Transmitter

Operating Instructions Edition 02/2007

Rosemount 752 Fieldbus Remote Indicator

Model 144H. Product Data Sheet , Rev DB February Content

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

Security that fits your needs perfectly DS7220 V2/DS7240 V2 intrusion control panel

Protect your investment with Safety Manager

technical datasheet technical datasheet

ARC BRIEF. MTL: Expanding Opportunities with a Focus on Fundamentals. Keywords. Summary. Analysis THOUGHT LEADERS FOR MANUFACTURING & SUPPLY CHAIN

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Product Information to the manual

APPLICATION DATA SHEET

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Rosemount 3144P Temperature Transmitter

Rosemount 644 Temperature Transmitter

explosion protection automation global partner of the process industry

Panel Mounted Fault Annunciator Series

/ sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities.

UDC100 Universal Digital Controller Specifications

Tank Gauging System Special Safety Instruction

Enraf Servo Gauge 854 ATG

Annubar Flowmeter Series

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Rosemount 3051CFP Integral Orifice Flowmeter

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Analog Input Module IC670ALG630

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Rosemount 3051SFC Compact Orifice Flowmeter

High Integrity Pressure Protection System

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Analog Annunciator Unit SACO 16 A3. Product Guide

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Certification Report of the ST3000 Pressure Transmitter

Certificate of Compliance

IQ8Control C Fire Alarm Panel

Rosemount 3051L Level Transmitter

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Certification Report of the ST 3000 Pressure Transmitter with HART 6

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

OPTIBAR DP 7060 Supplementary Instructions

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Transcription:

FOUNDATION TM fieldbus for LEPIU The TDC 2000 and TDC 3000 Low Energy Process Interface Unit (LEPIU) provides termination and pre-processing of various temperature signals. Due to the age of various components, these have become unavailable or very expensive to purchase. Many users are looking for a cost effective replacement. This document describes how, in case of temperature signals, the LEPIU system could be replaced by a FOUNDATION TM fieldbus solution in Zone 1 and Zone 2 hazardous area applications. Prepared by: Thomas Klatt Business Development Manager Marty Brickner Global Account Manager Honeywell

Pepperl+Fuchs is the proven market leader for innovative and highly available components for your fieldbus according to IEC 61158-2. With quality components to fit your process automation system and demands in the field our highly reliable and energy-efficient design allows you to focus on the task at hand. Knowing that your fieldbus is running. The High-Power Trunk Concept with Entity or FISCO devices: Connect the maximum number of devices to the same fieldbus trunk; and at the same time make use of maximum cable lengths. This concept utilizes standard power supplies such as the easy to install and configuration free Power Hub. Segment Protectors and FieldBarriers are installed close to field devices and limit the energy at the spur. You are free to work on field devices without hot work permit. Advanced Diagnostics: Take control of your fieldbus installation. This latest innovation brings transparency to fieldbus. Speed up commissioning with automated documentation. Measure fieldbus performance and detect changes in the control room before they become critical to your plants operation. You can rely on products built to serve your every need in fieldbus for process automation. You can gain from the experience of knowledgeable engineers to create your fieldbus solution. You can be at ease with products and solutions from Pepperl+Fuchs.

Page 1 of 8 FOUNDATION TM fieldbus for LEPIU Content Introduction......2 Structure of a LEPIU System.........2 FOUNDATION fieldbus solution on......3 Engineering......4 Workflow......7 Advantages...... 13

FOUNDATION T M fieldbus for LEPIU Page 2 of 13 Introduction The Low Energy Process Interface Unit (LEPIU) is used in a lot of applications for termination and preprocessing of analog inputs. They are commonly used with temperature signals where intrinsic safety (IS) or remote multiplexing of these signals is required. The LEPIU is a development of the late 1980's, therefore not only is the technology old, a lot of the components have now become obsolete and/or difficult to get. This document describes how such a LEPIU system for temperature signals could be replaced by Temperature Multi-Input devices (TM-I), using FOUNDATION TM fieldbus as data transmission technology. Structure of a LEPIU System LEPIU is a multiplexer system, consisting of A common card file assembly (CCFA) IS barrier(s) for intrinsic safe application Up to 16 multiplexer boxes, which contain the termination cards Figure 1: Structure of a LEPIU system Each termination card is able to handle up to 16 temperature sensors. Overall it is possible to handle up to 254 temperature sensors. The RTD/TC termination cards in the field are mounted in an enclosure according to the environmental requirements. There are two options available for a replacement: Replacing the whole enclosure including the required electronic Replacing just the electronic If the second option should be realized the new electronics must be mounted on a board which matches the inner dimensions of the field enclosure. These dimensions typically are 430 mm * 340 mm.

FOUNDATION TM fiel ieldbus solution Page 3 of 13 The main target is to transmit as many temperature signals as possible via the lowest amount of cables. Today a common technology for such a data transfer is FOUNDATION TM fieldbus. A solution for transmission of temperature signals by using this technology is shown in the following figure: Figure 2: Transmission of temperature signals via FOUNDATION TM fieldbus The temperature termination board is able to handle 16 temperature signals. This is equal to a termination card of the LEPIU system, and consists of a FieldBarrier and two Temperature Multi-Input devices for Zone 1 application or a Segment Protector and two Temperature Multi-Input devices for safe area or Zone 2 application As an example the following drawing shows the Zone 1 solution when just the electronic shall be replaced:

FOUNDATION T M fieldbus for LEPIU Page 4 of 13 Figure 3: Zone 1 temperature termination board With the original LEPIU system, differentiation had to be made between an RTD and a T/C termination board, using FOUNDATION fieldbus technology and the TM- I, this is not required anymore. Each input can be configured via the system independently. Engineering The number of connectable temperature termination boards depends on The required update time of the temperature signals Distance between

Page 5 of 13 o o the control room, where the fieldbus power supply used for this application is mounted and the last termination board the termination boards in the field When using as an example 4 temperature termination boards per segment, where each termination board consists of one FieldBarrier and two 8-channel TM-I (see Figure 2). This is equal to 16 temperature signals per termination board or 64 temperature signals per segment. One fieldbus power supply board with 25 V supply voltage at 360 ma for 4 segments One 4-segment Series C-FIM the overall amount of temperature signals per Series C-FIM is 256. Update time The update time for this layout can be calculated as follows: The Series C FIM (Fieldbus Interface Module) is the newest development from Honeywell. It supports four (4) H1 links and is able to realize 16 publications of process variables per second and link. Taking this into account all temperature signals of one temperature termination board will be transmitted within 1 s. Per link up to 4 temperature termination boards can be handled per segment/link which is equal to an update time of 4 s. Due to that the Series C FIM supports four (4) H1 links in parallel the update time for 256 temperature signals is also 4 s. Segment layout The field equipment consisting of Temperature sensors Temperature Multi Input device FieldBarrier (for zone 1 application) or Segment Protector (for zone 2 application) is completely powered by the fieldbus power supply located in the control room. It must be ensured that the fieldbus power supply provides enough energy to the field equipment. This could easily be verified by using the Segment Checker software (download free of charge see www.segmentchecker.com). When using the example mentioned above (64 temperature signals per segment) with the most cost effective fieldbus power supply (HD2-FBPS-1.25.360) a distance of approx. 400 m between the control room and the 1 st temperature termination board could be reached at an ambient temperature of 50 C. In this example the distance between 2 temperature termination boards is set to 50 m.

FOUNDATION T M fieldbus for LEPIU Page 6 of 13 Figure 4: Example segment layout If longer distances are required A fieldbus cable with a higher cross section (in the example above the cross section of the fieldbus cable is 0.8 mm²) A fieldbus power supply which offers more energy to the field can be used. Using existing cables? Fieldbus foundation recommends for FF application a cable called cable type A. It is not ensured that existing cables are matching the requirements of the FOUNDATION TM fieldbus cable specification. If existing cables should be used it is strongly recommended to do a checkout in advance. This checkout could be done by building up the worst segment and do a checkout with the Advanced Diagnostic module from Pepperl+Fuchs. In this respect worst segment means the segment with the longest cable run and the highest amount of temperature signals.

Page 7 of 13 Mechanical replacement Workflow Typically the LEPIU exchange will be done either when the existing system fails or during a modernization of the DCS (e.g from Honeywell TDC 2000 to Experion C300 controller). In that case the workflow for the hardware exchange is as follows when just the electronic will be replaced: 1. Remove old LEPIU PCB 2. Mount the Pepperl+Fuchs temperature termination board into the enclosure

FOUNDATION T M fieldbus for LEPIU Page 8 of 13 3. Connect the wires of the temperature sensors to Ex i terminals of the TM-I 4. Connect the Ex e trunk terminals to FF H1 trunk Configuration and Parameterization When installing a Temperature Multi Input device each channel of this component needs to be parameterized with the type of sensor connected to the channel technology in use (e.g. 2, 3 or 4-wire technology for RTD s; internal or external cold junction compensation for T/C s) lead breakage and/or short circuit monitoring To keep this required engineering work as easy and quick as possible the Honeywell Experion PKS system and the Pepperl+Fuchs TM-I are supporting a method which allows the user to do this parameterization and to select to which channels this parameter set shall be downloaded. These methods can be executed from Experion by starting the Method Manager (see example below) or from the Control Builder. Example: Eight PT100 RTD s are connected to a Temperature Multi Input device. They all require the same set of parameters. This example shows how this works within Experion PKS by starting the Methods Manager:

Page 9 of 13 Step 1: Define channels to be configured. In case Select channels will be chosen it can be configured which channels shall be configured. Step 2: Choose type of temperature sensor

FOUNDATION T M fieldbus for LEPIU Page 10 of 13 Step 3: Define type of sensor connection (RTD s only) Step 4: Define type of Unit

Page 11 of 13 Step 5: Enable/disable sensor diagnostics Step 6: Define filter time for primary value

FOUNDATION T M fieldbus for LEPIU Page 12 of 13 Step 7: Confirmation of channels to be parameterized Step 8: The parameter set will be written automatically to the device channel by channel. Step 9: Confirmation that all 8 channels are written and the channels are set to Auto mode. The procedure above has shown how to configure the Transducer Blocks of the TM-I. Additionally it is required to configure the application itself in the meaning of engineering the control or monitoring loops. When for example Control Builder is used it is simply Defining a Control Module Opening the Control Module Selecting the required Function Blocks for example o AI function blocks or o MAI function block for the TM-I Drag and drop the function blocks in the loop

Page 13 of 13 Configure o Interconnection of the function blocks o Required PV range o Channel number o Alarms o After configuring the loops just a download is required and the system can operate. Advantages Existing field wiring for all T/C s and RTD s can be used and do not need to be extracted out of the cable glands with the possible risk of breaking leads. Standard solution for zone 1 or zone 2 application. Other solutions can be made available on demand. Full diagnostic capability of physical layer by using an Advanced Diagnostic Module. Future proof technology (FF) compatible. Cost effective; minimum cabling between cabinet and control room exchange. If the existing cable matches the requirements of FOUNDATION TM fieldbus H1 no wiring is required (can be approved with Advanced diagnostic module from Pepperl+Fuchs). Quick and easy engineering by the use of methods