Where technical minds provide innovative solutions

Similar documents
SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

ASCO Series 185 Power Transfer Switches

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

CHAPTER 20 SERVICE EQUIPMENT

PART GENERAL 1.01 SECTION INCLUDES

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

PANELBOARDS & BUILDING DISTRIBUTION

SECTION ISOLATED POWER SYSTEMS

A. Shop Drawing submittals shall include, but not be limited to, the following:

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Day after day, Season after season, Generation after generation.

MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET

SECTION ELECTRICAL GENERAL PROVISIONS

ASME Packaged Electric Water Heater

CONTENTS AUTOMATIC TRANSFER SWITCHES

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

PowerWave 2 Busway System

SUPPORT EQUIPMENT MODULAR RAPIDLY DEPLOYABLE MOBILE RUGGED RELIABLE VERSATILE

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

TOOLS & MISCELLANEOUS

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

uu3-1/2-inch-deep rigidized roof ribs are locked to the roof wind ring, so the roof acts as a single, dynamic unit.

Packaged Steam Fired Water Heater

TABLE OF CONTENTS page 2

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

CX1 ProVector Explosion-Proof Heaters

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

Installation and Maintenance Manual Please retain this manual for future reference.

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Electricity Unit Notes. Agriculture Mechanics I

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

DRYER INSTALLATION INSTRUCTIONS

Municipal Code of Chicago TITLE 14E ELECTRICAL CODE

PTAC 2017 Air Conditioner Collection

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

Installation Instructions

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Packaged Terminal Air Conditioner (PTAC)

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

CF1 ProVector Explosion-Proof Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Installation Instructions

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Schneider Electric ibusway for Data Center: Schneider Electric Powerbus Plug-In Busway

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

HOLDING/PROOFING CABINETS HP2H-2M-SN APPLICATION OPTIONAL MODULAR CONSTRUCTION

CADDY CORPORATION. Utility Distribution Systems

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

Portable Vertical Air-Conditioning and Heating Systems

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION INSTRUCTIONS

CATALOG OF REPLACEMENT PARTS

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Circulation Heaters Selection Guidelines

Miniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Student Guide. Wiring Edition. Compliments of. Georgia EMC East Exchange Place Tucker, GA (770)

Element D Services Electrical

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Compressed Air Distribution System

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

Instrument Rated Metering Equipment

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Principle of Operation:

MODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

SECTION DUCTWORK

Transcription:

Where technical minds provide innovative solutions From Utility Company (ConEd, PSE&G, etc) Service End Box CT Cabinet Custom Crown/ Pull Boxes Internal Construction (Example) Service Entrance Distribution Section Service Section Internal Construction (Example) PanelBoards (Meter Bank) Multi-Family Metering Pull Thru Wireway (Trough) Powder coated. Also available in Type 304 or 316 Stainless Steel Downstream Equipment Please visit our Pull Box and Enclosures section

Panelboards are available in different sizes(p1-p5), power ratings (Amp), internal construction. Here we use Lighting Panel (P1) as an example The interior includes overcurrent protection devices (breakers), bus bars and insulated neutral bus bars. A lighting panel interior is mounted inside the can (back box) using 4 mounting studs. Residential circuit breakers are typically1-pole, 2-pole, or 4-pole breakers with current ratings of 225 amps or less and voltage ratings of 120 volts, 120/240 volts, or 240 volts

SWITCHBOARD There are multiple elements that make up a switchboard. Included in the list of elements are a frame, buses, overcurrent protection devices(breakers, Switches), service metering, and outer covers. Bus (busbar) Phase Arrangement Bus bars (made out of copper) are required to have phases in sequence so an installer will find the same fixedphase arrangement in each termination point in any switchboard. This requirement is established by NEMA (National Electrical Manufacturers Association). Disconnect switches CT Cabinet Pull Box Several options are available to bring power into the switchboard service section, cable, pull box and bus duct. We will look at each one individually. Cable and Conduit Pull Box Added Bus Duct Entrance

Busway Advantage In electrical power distribution, a bus duct (also called busway), is a sheet metal duct containing either copper or aluminum busbars for the purpose of conducting a substantial current of electricity. The three main ways that a busway system will save you up front money over conduit and cable are: 1) Material Costs, 2)Shipping Costs, 3)Labor Costs Busway is defined by the National Electrical Manufacturers Association (NEMA) as:...a prefabricated electrical distribution system consisting of bus bars in a protective enclosure, including straight lengths, fittings, devices, and accessories. Busway includes bus bars, an insulating and/or support material, and a sheet metal housing. Elbows enable turns and height changes in the busway system. An elbow can turn the busway system right or left, up or down. Elbows are supplied with a joint stack and covers. Elbows may be ordered as stacks or sections. Elbow stacks are joint stacks that are angled "edgewise" (for up/down changes) or "flatwise" (for left/right changes).

Metering System An insulating block secures the lugs, jaws, and bussing to the enclosure. Current Path When in operation, electrical current flows from the service (line-side) conductors through the meter to the load-side conductors and then to the load center or panelboard for distribution to branch loads Each watt-hour meter requires a meter socket to safely and securely connect it to the electrical service. Because meter designs and utility requirements vary, Apelio offers a variety of singleposition and multiple-position meter sockets.

TROUGH Wireway Trough is designed to protect wiring against rain, sleet and snow in outdoor installations, or indoors against dripping water. Fabricated in accordance with UL specifications from 16-14 gauge Galvanized Powder coated Steel, Aluminum or SS304/ SS316. Continuously welded body, gasketed rainproof Cover with heavy duty butt hinges and quick release clamps. Telescope Fitting Adjustable Telescopic Fitting makes it easy to adjust the length of final connection and save the hassle of precise measuring 90 Sweep Elbow and Sweep Tee designed for large radius turns. Used with vertical or horizontal Trough sections. Removable top and inside covers.

Pull Boxes/ Crown Boxes Apelio's ability to manufacture high end Pull Boxes is not limited to custom boxes. We carry a large array of standard Pull Boxes ranging from the smallest to the largest sizes, painted to withstand rust and made from quality materials. Custom dimensioning to customer specifications, our boxes are made with superior welding that helps prevent box deformation when pulling cables or punching multiple holes in them. Our Pull Boxes made of rigid body acuminated by superior welding and materials to withstand harsh environments. Apelio offers wide range of material thickness and type to satisfy every need. Bodies and doors fabricated from 16,14, or 12 gauge carbon steel and pre-galvanized or Galvannealed steel Removable Covers Sectional Dismantle Powder coating availability SwitchBoard Hole Lineup Complex Design with dividing capabilities will allow customer to use the same box in different applications

Pull Boxes, Enclosures APELIO offers a wide range of electrical enclosures ideal for a variety of indoor or outdoor applications. The National Electrical Manufacturer Association (NEMA) uses a standard rating system that defines the types of environments in which an electrical enclosure can be used, and frequently signifies a fixed enclosure's ability to withstand certain environmental conditions. We manufacture All NEMA rated enclosures. Per customer request most of them can be made our of either Powder coated Galvanized steel, Aluminum or Stainless Steel type 304 or 316. Here we explain a few the most popular NEMA types.. NEMA 4X enclosures are primarily intended for outdoor use and offer a superior level of protection from corrosion and extreme environments. APELIO produces these enclosures in 5052-H32 aluminum, 304 or 316 Stainless Steel and they are available in a number of styles for your demanding applications. Our adherence to the rigorous NEMA standards will give you a quality enclosure, delivered quickly at a competitive price. NEMA 12 enclosures are intended mainly for indoor industrial, manufacturing, and machining applications. These metal enclosures will protect against dust, dirt, and dripping non-corrosive liquids, oil and lubricants NEMA 3R enclosures are compatible for both indoor or outdoor applications, and holds the least demanding rating for outdoor use. Mostly made for lighting contractors, housing power distribution, switch gear, and other electrical components that need to be protected in an outdoor environment. APELIO produces NEMA 1 electrical enclosures for general purpose indoor use. We adhere to NEMA standards to provide you a quality enclosure for most basic applications. NEMA 1 enclosures are intended for use fundamental applications, or where extreme environmental conditions do not exist