Date: Customer: Project: Type: Qty: M6 My White Order Code: L6 - A - TW - - - - - - - L6 A Series L6 M6 Light Engine A 695 lm/9.95w per foot Values calculated from a fixture with CLL using LW Shielding and DMD driver. For additional information please see page. TW CCT TW Tunable White - 700K thru 6500K Shielding LW MI LED Optimized Clear Lens white lens w/microprism NB LMO Symmetric A LMO Asymmetric 0 Wall Washer A5 LMO Asymmetric 5 Wall Grazer BW LMO Batwing Mounting C S RS W FF Cable Swivel Stem Rigid Stem Wall Mount Nominal Fixture Length 0 ft. 0 ft. 0 ft. 05 5 ft. 06 6 ft. 07 7 ft. 08 8 ft. 09 9 ft. Surface Mount (w/flex Whip) 0 0 ft. ft. Individual fixtures and runs are supplied in nominal lengths to ensure full, even, illumination. See pages thru 6 for additional details. F F Surface Mount Surface Mount (w/ x J-Box (w/x J-Box cover) cover) ft. XX Runs (over ), round up to the nearest foot and replace the xx with the # (i.e. = nominal) Over 8 supplied with or more housings that are joined in the field. Finish WH White BK Black SV Silver SP Specify Premium Color Custom colors are available, please consult Factory Voltage 0 0 Volt 77 77 Volt UNV 0 thru 77 50/60hz capable Fixture Options DL Damp Location Rated FS In-line Fuse SS Separate Switching See page 8 for full details and restrictions Dimming Options DMD eldoled DALI (Logarithmic) DMX eldoled DMX (Linear) Emergency Options EC Emergency Circuit Wiring See page 8 for full details and restrictions Product Modifications Please list modification requirements for review by factory: Approvals 5YEAR LED WARRANTY ARRA Compliant ADA Compliant Date: Page of 0 M6MYWHITE v.0
/6 (7mm) 5 /6 (mm) 7 /6 (7mm) Construction: Housing - Continuous, low copper 606-T6 extruded aluminum profile with aluminum endcaps, available as Individual fixtures (up to ) or Runs. Geartray - Low copper 606-T6 extruded aluminum profile. Shielding - Extruded, impact resistant acrylic lens: - LED optimized white lens (LW) - Clear lens with microprism inlay (MI) - LMO symmetric lens (NB) - LMO Asymmetric 5 wall grazer (A5) - LMO Asymmetric 0 wall washer (A) - LMO Batwing (BW) As a result of the color mixing LEDs, LW lens is recommended for the most uniform illumination, other lenses may allow the separation of colors to be visible Mounting(s) - /6 Aircraft Cable, Ø/ Swivel or Rigid Steel Stem, Wall Bracket, Surface mounting (see pages thru 6 for details). ** Cable, Stem and Wall mountings may not be symmetrical for Runs and Configurations due to the use of modular housing lengths. If symmetrical suspensions are required please consult the factory. Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs are available in approximately increments starting at the nominal fixture length. ** Individual luminaires are not joinable in the field. Exact length luminaires - Individual luminaires and runs are available in exact lengths to meet your project needs. Please consult factory with your requirements. ** Lens luminance may soften at the very ends of the straight sections for exact length luminaires. M6 Joiner(s) - Runs are supplied with multiple housings that are joined together in the field using the supplied M6 Joiner System. This allows ease of installation and ensures a uniform appearance (see page 8 for detail). Electrical/Performance: Constant Lumen Level (CLL) Curve Selux recommends utilizing the Constant Lumen Level (CLL) curve for the MyWhite product. This is achieved using an algorithm programmed into the controls for driving the two channels of the driver simultaneously so that while adjusting the CCT, the lumen output remains the same. For recommended controls for CLL, please consult Selux. Max Output An alternate way to control the output is by having each channel of the driver controlled individually while changing the CCT. Controlling the channels individually can result in a higher lumen level (see chart on Photometry page). LED Light Engine Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 9% at 5,000 hours and 86% at 60,000 hours per TM- report (based on CLL); 86% at 5,000 hours and 7% at 50,000 hours (based on max output). LED Life Calculated L70 greater than 0,000 hours and Reported L70 greater than 60,000 hours at 5 C per TM- (for CLL); Reported L70 of 58,000 hours at 5 C per TM- (for max output). Delivered Lumens - Due to LED manufacturer s tolerances the listed output has a ±5% tolerance. For outputs based on different shielding please see photometry section at the end. CCT - Tunable CCT from 700K thru 6500K, tolerance within a -step MacAdam ellipse. CRI - Min. 80 Driver - High efficiency, constant current, soft start, Electronic Class with a PFC>0.90. For more detailed information on the available drivers please see page 7. Wall Controller - Optional wall controller can be ordered for use with DMX fixtures. See DMX controller spec sheet for more details. Thermal Performance: Ambient Operating Temperature - Luminaires suitable for Max. ambient temperature of 5 C (95 F). Min. ambient temperature of -0 C (- F). Luminaire Finish: Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI. All products undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultraviolet resistance for color retention. Standard interior colors are White (WH), Black (BK), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. Warranty: 5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the M6 MyWhite LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see Selux Terms and Condition of Sale. Certifications and Compliance: NRTL - For Dry and Damp location (I.E. culus; ccsaus) ADA Compliant ARRA Compliant RoHS Compliant Page of 0 M6MYWHITE v.0
Cable Mounting (C) Cable Mounting (C). Ø /6 Aircraft Cable with chrome gripper for easy adjustment (8 max. from ceiling to luminaire). Nominal Length A Housing Length Cable Mounting (C) - Dimensions * B (Ref.) End Suspensions C D Power Feed Location DMX In/Out MM MM MM MM MM 0 ( ft.) ' - /" 66 0' - /8" 5 '- 8 /6" 509 0' - /8" 9 0' - /8" 9 0 ( ft.) ' - 5/6" 9 0' - /8" 79 '- 6 /6" 76 0' - /8" 5 0' - /8" 5 0 ( ft.) ' - /" 5 0' - /8" 79 '- 6" 067 0' - /8" 5 0' - /8" 5 05 (5 ft.) ' - 0 /6" 9 0' - /8" 79 '- 7/6" 0' - /8" 5 0' - /8" 5 06 (6 ft.) 5' - 0 5/8" 79 0' - /8" 79 5'- 7/6" 66 0' - /8" 5 0' - /8" 5 07 (7 ft.) 7' - /" 0 0' - /8" 79 6'- 6" 98 0' - /8" 5 0' - /8" 5 08 (8 ft.) 8' - /" 0' - /8" 79 7'- 6" 86 0' - /8" 5 0' - /8" 5 09 (9 ft.) 8' - 0 5/8" 709 0' - /8" 79 8'- 7/6" 55 0' - /8" 5 0' - /8" 5 0 (0 ft.) 9' - 0 5/8" 0 0' - /8" 79 9'- /8" 85 0' - /8" 5 0' - /8" 5 ( ft.) ' - /6" 58 0' - /8" 79 0-6" 00 0' - /8" 5 0' - /8" 5 ( ft.) ' - /6" 66 0' - /8" 79 '- 5 5/6" 50 0' - /8" 5 0' - /8" 5 *Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance. L60 Cable (C) Suspension Detail (DMX Feed location(s) only) L6 Cable (C) Suspension Detail (Feed location(s) only) L6 Cable (C) Suspension Detail (Non-Feed location(s) only) r Outlet box for feed only (by others) Cross bar with /-0 rod and ground screw x Outlet box screws (by others) / x 5 diameter canopy Outlet box for feed only (by others) Cross bar with /-0 rod and ground screw x Outlet box screws (by others) / x 5 diameter canopy Cord strain relief bushing Min. 5/8 to Max. / / - 0 Threaded Rod (supplied & installed in the field by others) / x diameter Canopy /-0 Slip ring coupler D Cable Grommet /-0 Slip ring coupler DMX cables /6 Aircraft cable x White cable stay /-0 Slip ring coupler Feed cord /6 Aircraft cable x White cable stay Chrome gripper Luminaire /6 Aircraft cable Chrome gripper Luminaire Chrome gripper Luminaire Cable Grommet Page of 0 M6MYWHITE v.0
Stem Mounting (S & RS) Stem Mounting (S & RS). Ø / Swivel Stem provides 5 swivel and can be cut in field (8 max. from ceiling to luminaire).. Ø / Rigid Stem is fixed and is not able to be cut/adjusted in field (8 max. from ceiling to luminaire). If the project requires different lengths than above, please consult the factory. Nominal Length A Housing Length Swivel (S) & Rigid Stem (RS) Mountings - Dimensions * B (Ref.) End Suspensions C D Power Feed Location DMX In/Out MM MM MM MM MM 0 ( ft.) '- /" 66 0' - /8" 5 '- 8 /6" 509 0' - /8" 5 0' - /8" 5 0 ( ft.) '- 5/6" 9 0' - /8" 79 '- 6 /6" 76 0' - /8" 79 0' - /8" 79 0 ( ft.) '- /" 5 0' - /8" 79 '- 6" 067 0' - /8" 79 0' - /8" 79 05 (5 ft.) '- 0 /6" 9 0' - /8" 79 '- 7/6" 0' - /8" 79 0' - /8" 79 06 (6 ft.) 5'- 0 5/8" 79 0' - /8" 79 5'- 7/6" 66 0' - /8" 79 0' - /8" 79 07 (7 ft.) 7 - /" 0 0' - /8" 79 6'- 6" 98 0' - /8" 79 0' - /8" 79 08 (8 ft.) 8'- /" 0' - /8" 79 7'- 6" 86 0' - /8" 79 0' - /8" 79 09 (9 ft.) 8'- 0 5/8" 709 0' - /8" 79 8'- 7/6" 55 0' - /8" 79 0' - /8" 79 0 (0 ft.) 9'- 0 5/8" 0 0' - /8" 79 9'- /8" 85 0' - /8" 79 0' - /8" 79 ( ft.) '- /6" 58 0' - /8" 79 0-6" 00 0' - /8" 79 0' - /8" 79 ( ft.) '-/6" 66 0' - /8" 79 '- 5 5/6" 50 0' - /8" 79 0' - /8" 79 *Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance. L6 Swivel Stem (S) Suspension Detail (feed wires through stem supplied by Selux) L6 Rigid Stem (RS) Suspension Detail (feed wires through stem supplied by Selux) Outlet box (supplied & installed by others) Hemispherical assembly Cotter pin Swivel crossbar with ground screw / x 5 diameter canopy / IP steel swivel stem /8 Male x / Male hex bushing Luminaire Outlet box (supplied & installed by others) / IP Crossbar with ground screw / IP Hex nut / x 5 diameter canopy Canopy securing screw / IP Steel rigid stem /8 Male x / Male hex bushing Luminaire Page of 0 M6MYWHITE v.0
Wall Mounting (W) Nominal Length A Housing Length Wall (W) Mount - Dimensions * B (Ref.) End Suspensions C D Power Feed Location DMX In/Out MM MM MM MM MM 0 ( ft.) ' - /" 66 0' - /8" 79 ' - 6 /6" 58 0' - /8" 79 0' - /8" 79 0 ( ft.) ' - 5/6" 9 0' - 6 /8" 56 ' - /8" 6 0' - 6 /8" 56 0' - 6 /8" 56 0 ( ft.) ' - /" 5 0' - 6 /8" 56 ' - 0" 9 0' - 6 /8" 56 0' - 6 /8" 56 05 (5 ft.) ' - 0 /6" 9 0' - 6 /8" 56 ' - 0 7/6" 80 0' - 6 /8" 56 0' - 6 /8" 56 06 (6 ft.) 5' - 0 5/8" 79 0' - 6 /8" 56 ' - 0 7/6" 8 0' - 6 /8" 56 0' - 6 /8" 56 07 (7 ft.) 7' - /" 0 0' - 6 /8" 56 6' - 0" 89 0' - 6 /8" 56 0' - 6 /8" 56 08 (8 ft.) 8' - /" 0' - 6 /8" 56 7' - 0" 0' - 6 /8" 56 0' - 6 /8" 56 09 (9 ft.) 8' - 0 5/8" 709 0' - 6 /8" 56 7' - 0 7/6" 98 0' - 6 /8" 56 0' - 6 /8" 56 0 (0 ft.) 9' - 0 5/8" 0 0' - 6 /8" 56 8' - 0 /8" 70 0' - 6 /8" 56 0' - 6 /8" 56 ( ft.) ' - /6" 58 0' - 6 /8" 56 9' - 5/6" 07 0' - 6 /8" 56 0' - 6 /8" 56 ( ft.) ' - /6" 66 0' - 6 /8" 56 0' - 7/8" 50 0' - 6 /8" 56 0' - 6 /8" 56 *Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance. Wall Mount (W) (Covers a x J-Box only) / (70mm). Aluminum wall bracket (by Selux). x J-Box at feed location (supplied and installed by others).. /-0 Threaded rod, /-0 lock washer and /-0 nut required to anchor the wall bracket. Mounting hardware supplied and installed to code by others. (0mm) (5mm) 7 /6 (6mm) Page 5 of 0 M6MYWHITE v.0
Surface Mounting (FF, F & F) - to 8 Surface Mounting (FF, F & F) - Over 9 Nominal Length A Housing Length MM * B (Ref.) End Suspensions MM * B End Suspensions Surface Mount (FF, F, & F) - Dimensions MM C MM C MM C D Power Feed Location DMX In/Out MM MM MM 0 ( ft.) ' - /" 66 0' - 5/8" N/A ' - 9" 5 N/A N/A 0' - /8" 05 0' - /8" 05 0 ( ft.) ' - 5/6" 9 0' - 6 /8" 56 N/A ' - /8" 6 N/A N/A 0' - /8" 5 0' - /8" 5 0 ( ft.) ' - /" 5 0' - 6 /8" 56 N/A 9 N/A N/A 0' - /8" 5 0' - /8" 5 05 (5 ft.) ' - 0 /6" 06 (6 ft.) 5' - 0 5/8" 9 79 0' - 6 /8" 56 N/A ' - 0 7/6" 0' - 6 /8" 56 N/A ' 9 80 N/A N/A 0' - /8" 5 0' - /8" 5 ' - 0 /8" 569 N/A 0' - /8" 5 0' - /8" 5 07 (7 ft.) 7' - /" 0 0' - 6 /8" 56 N/A ' 9 ' 9 N/A 0' - /8" 5 0' - /8" 5 08 (8 ft.) 8' - /" 0' - 6 /8" 56 N/A ' 9 ' 9 N/A 0' - /8" 5 0' - /8" 5 09 (9 ft.) 8' - 0 5/8" 0 (0 ft.) 9' - 0 5/8" 709 0 0' - 6 /8" 56 6 5 ' - 0 7/6" 0' - 6 /8" 56 6 5 ' 9 80 N/A ' 9 0' - /8" 5 0' - /8" 5 ' - 0 /8" 569 ' 9 0' - /8" 5 0' - /8" 5 ( ft.) ' - /6" 58 0' - 6 /8" 56 6 5 ' 9 ' 9 ' 9 0' - /8" 5 0' - /8" 5 ( ft.) ' - /6" 66 0' - 6 /8" 56 6 5 ' 9 ' 9 ' 9 0' - /8" 5 0' - /8" 5 *Dimension(s) rounded to the nearest /6 with a ± /6 (mm) tolerance. Surface Mount (FF)* (with Flex Whip) Surface Mount (F) (with x J-Box cover) Surface Mount (F) (with x J-Box cover) * Please note: Fixture does not cover a J-Box.. 6 Flex Whip. Ø 5/6 Mounting hole drilled at the factory(mounting hardware to code by others).. x J-Box at feed location (supplied and installed by others).. x J-Box cover (by Selux). 5. x J-Box at feed location (supplied and installed by others). 6. x J-Box cover (by Selux). Page 6 of 0 M6MYWHITE v.0
eldoled Dimming Driver: eldoled DALI dimming (DMD) Luminaires supplied with DUALdrive DALI dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to %. For dim to dark (down to 0.%), please consult factory. Max. inrush current per driver 0mA²s. *For control recommendation for eldoled drivers, please contact eldoled. eldo DMX dimming (DMX) Luminaires supplied with POWERdrive DMX dimming driver for linear dimming curve. Minimum dimming level preset at factory to %. For dim to dark (down to 0.%), please consult factory. Max. inrush current per driver 0mA(squared)s. Selux recommends a maximum of drivers in a DMX universe. DMX fixtures can be daisy chained together (remove the terminating resistor at the end of the fixture and connect the DMX cable from the next fixture). Driver Quantity ft. ft. ft. 5 ft. 6 ft. 7 ft. 8 ft. 9 ft. 0 ft. ft. ft. RUN DMD or DMX driver Approximately drivers per ft. Wiring Diagrams DALI Logarithmic (DMD) DMD Page 7 of 0 M6MYWHITE v.0
Wiring Diagrams DMX dimming (DMX) GREEN POWER FEED BLACK WHITE TERMINATION RESISTOR DMX FEED When Daisy Chaning fixtures, WHEN DAISY CHANING FIXTURES, REMOVE remove TERMINATION termination RESISTOR AND CONNECT resistor DMX and connect OUT CABLE DMX out cable HOUSING, INDIVIDUAL/START GREEN POWER FEED BLACK WHITE DMX CABLE HOUSING, MID HOUSING, END TERMINATION RESISTOR DMX FEED BLACK - DMX NEGATIVE WHITE - DMX POSITIVE BARE - SHIELD BARE WHITE BLACK BLACK WHITE BARE POSITION MALE CONNECTOR 8- GA 00V 0A POSITION FEMALE CONNECTOR 8- GA 00V 0A BLACK WHITE BARE BARE WHITE BLACK POSITION MALE CONNECTOR -GA 00V 0A POSITION FEMALE CONNECTOR -GA 00V 0A Page 8 of 0 M6MYWHITE v.0
Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed. (supplied with an 8A slow burn fuse). Damp Location (DL) - Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings. All solder points on LED boards are conformal coated. The phosphor layer of the LEDs is free of coating to avoid hazing. Separate Switching (SS) - Luminaires available with separately switched (nominal) sections starting at 7 and up. Luminaire is intended to be wired to the same panel/breaker (not intended for Emergency use). - To specify this option, the number of separately switched sections and locations of these sections must be provided at time of order. *If the project requires different separate switching than outlined above please consult the factory. Emergency Circuit (EC) - Luminaires with EC option compliant to UL 9 listed emergency luminaire. EC luminaires are intended to be wired to separate panels/breakers for emergency use. - For to 6 nominal luminaires, the entire fixture is wired for operation on emergency circuit. - For 7 and up nominal luminaires, the first nominal length is wired for operation by a separate EM circuit by default to meet the required Life Safety Code (NFPA 0). **If a different configuration is needed please consult the factory. Flex Whip - standard for FF mounting 90 Elbow on top of the housing (7/8" feed hole) /8" flexible metal conduit (6' long) 6" leads Straight fitting Joiner System - standard for Runs Fixture extrusion Recommended # Phillips drive Joiner extrusion Fixture extrusion Additional view Page 9 of 0 M6MYWHITE v.0
Photometry LW Optics / W LED / CLO Link to photometry (IES & PDF files) 06 785 5 6 Catalog #: L6-A-TW-LW-X-0-WH-0 Report #: 75-0CLL Delievered Lumens: 776 Input Watts: 8.86W Efficacy: 70 Power Factor: 0.977 Total Harmonic Distortion: 5.% CCT: 700-6500K CRI: 8. Max Candela: 06.7 @ from Vertical Spacing Criterion (0-80):.6 Spacing Criterion (90-70):. Spacing Criterion (Diagonal):. Maximum Candela = 06.7 Located At Horizontal Angle = 0, Vertical Angle = # - Vertical Plane Through Horizontal Angles (90-70) # - Vertical Plane Through Horizontal Angles (0-80) LUMEN OUTPUT BASED ON CONTROL SETTINGS MAX OUTPUT LEVEL Driver may limit output above this line This photometry can be used for all CCTs when utilizing the constant lumen level (CLL) curve for My White. For other outputs, please consult the factory. CONSTANT LUMEN LEVEL 700K 6500K CCT RECOMMENDED AREA OF OPERATION (CONSTANT LUMEN LEVEL [CLL] SETTINGS) ADDITIONAL Results may LUMEN fluctuate ADJUSTABILITY when USING fixture MAX is OUTPUT used outside CURVE of the Constant Lumen Level curve. My White and the Circadian Rhythm Humans have an internal clock that affects everything from sleep patterns to productivity to health. This clock is called the circadian rhythm. As humans evolved in the days before electric lighting, they had natural exposure to various levels (both color temperature and intensity) from the sun. By adjusting electric lighting to mimic the natural hue and intensity of the sun, it can help restore the body to a natural state. Various studies have shown that this can help with alertness, behavioral issues, and productivity. The Selux proprietary My White technology allows you to adjust both the amount and color of your light, creating a comfortable environment for offices, educational facilities, hospitality, or any other installation where varying light could benefit the occupants. Set up the My White luminaires to a whole building solution, and you could create an automatic adjustment to the light to mimic daylight. Page 0 of 0 M6MYWHITE v.0