Clothes Cleaning Process

Similar documents
Issued $2.50. DuraPark Type A2LS. Heavy-Duty Drum Brake Assembly. Maintenance Manual MM Supersedes Lucas Catalog No. XDA911 (July 1995)

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

Respirable Crystalline Silica Exposure Control Plan

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Lead Safety for Renovation, Repair, and Painting. Requirements in the EPA RRP Rule:

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Contractor Safety. Workplace Safety & Environmental Division

BLAST-IT-ALL BUMPER BLASTER

Protecting Tuckpointing Workers from Silica Dust: Draft Recommendations for a Ventilated Grinder

or with a higher exposure potential than the processes, types of material, control methods, work

Spray Painting and Coating

Dust Collectors & Fume Exhausters

REVOLUTIONARY RESPIRATORY PROTECTION CLEANSPACE2 NIOSH APPROVED TC-21C

FLUID BED EQUIPMENT. Drying

REVOLUTIONARY RESPIRATORY PROTECTION CLEANSPACE2 NIOSH APPROVED TC-21C-0957

An Aid to Fugitive Material Control in Coal Ash Applications

Silica Dust Specified Exposure Control Methods

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

Portable Dust Collection Systems

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

DUST COLLECTION TRAINING. Revision 2013

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

MARTIN Insertable Dust Collector

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

Type N RotoClone. Hydrostatic Precipitator. Better Air is Our Business

Guidelines for Optimizing Drying and Blow-Off Operations

Reducing the Cost and Risk of Dust Collection in Coal

Materials to Restrict Access and Cover the Floor/Ground Signs

Table 1. Exposure Control Methods for Selected Construction Operations

RESPIRABLE CRYSTALLINE SILICA PARAGRAPHS (C) THROUGH (J)

airblastechtips Technical Tips for the Surface Treatment Industry

Quick Reference Guide to Cabinet types

Fume Hood Safety TYPES OF FUME HOODS

Florida International University. Biosafety Cabinet Program

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Engineering and Work Practice Control Methods

DUST MANAGEMENT PRODUCT GUIDE DURA RANGE. Issue Date 01.18

Use saw equipped with integrated water delivery system that continuously feeds water to the blade.

HTIW brand names you may recognize include: In use HTIW:

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Results of Vacuum Attachment Efficiency Evaluation MBX Bristle Blaster Power Tool Dust Collection System KTA Project No

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Page 1 of 18. Part# /5/2013

10 Tips on Selecting Cartridge Dust Collection Equipment for Tablet Presses

73. MEDICAL SURVEILLANCE - Triggers 74. 1)Exposure AL > 30 days/year 75. 2)Exposure > PEL 76. Wearing a Negative Pressure Respirator - 30 days/year

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

Discover the Difference

DALAMATIC DUST COLLECTORS

Silica Exposure Control Matrix

HANTAVIRUS PREVENTION: CLEANUP OF RODENT CONTAMINATION

OSHA Table 1

BLAST-IT-ALL PRESSURE BLAST CABINET

LITTLE BLASTER LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC WITH DUST COLLECTOR

DUST REMOVAL SYSTEM SUBMITTALS

DUST. Dust is in all workplaces. It not only affects workers lungs, it clogs up. more maintenance and cleaning.

RONDA 200. RONDA 200 when life is too short for hobby vacuum cleaners OTHER MACHINES FOR SIMILAR PURPOSES RONDA 20 RONDA 400

DUST MANAGEMENT PRODUCT GUIDE DURA RANGE

Combustible Dust Issues

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

Division 11 - Equipment

VP, Facilities and Construction Management

Rutgers Environmental Health and Safety (REHS)

SEMICONDUCTOR FABRICATION FACILITIES

ACT Cartridge Dust Collector

x 24 POLYMER CABINET

42 X 24 FT 48 X 24 FT

Packed With Features. Smart Pulsar controls are conveniently

OPERATOR'S MANUAL. Cat. No. M18 CDEX M18-28 CPDEX M18 AND M18 /M28 HAMMERVAC DEDICATED DUST EXTRACTORS

Product Selection Guide

Perchloroethylene in Dry Cleaning

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Packed With Features ACCESSIBLE. Filter cartridge is automatically cleaned each time the pedal is operated.

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Underfloor Air Distribution:

SEMICONDUCTOR FABRICATION FACILITIES

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

C&W specializes in dust control for a variety of sand-related applications.

How to comply with CDC Guidelines

Crystalline Silica Control Methods

FAMILY OF CABINET BLASTERS INSTRUCTION AND ASSEMBLY MANUAL

When the Dust Settles: Combating Combustive Dust in Food Manufacturing

x 24 CABINET BLASTER x 24 CABINET BLASTER WITH FOOT PEDAL

EqUIPMENT LAYOUT MANUAL

Specified Exposure Control Methods When Working With Materials Containing Crystalline Silica

Key Question. What is the most important aspect to the removal and cleaning of material?

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

TRION Air Purification systems

Machine and Power Tool Safety Checklist. Version 1.2 January Chestnut Street, Suite 400, Philadelphia, PA

Models: GW/R-T GW/R-2-T GW/R-3-T

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

SEMICONDUCTOR FABRICATION FACILITIES

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

USER'S INFORMATION MANUAL

Unimaster Dust Collectors

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

Transcription:

Clothes Cleaning Process Instructional Materials

Table of Contents Background Information... 1-2 Crystalline Silica and Health Risks Silicosis Project History... 3 The Cleaning Process... 4-7 Booth Dimensions Air Spray Manifold Design Compressed Air Volume Required Exhaust Air Volume Reservoir Calculations Improved Booth Design... 8-9 Care & Maintenance... 10 Resources & References... 11 Clothes Cleaning Process Instructions... 12 Notice to U.S. Operations: This Clothes Cleaning Process is not currently approved by the Mine Safety and Health Administration (MSHA). A petition for modification to use this system was submitted by Unimin Corporation for its Marston facility and approved by MSHA in June 2004. For U.S. companies seeking to implement this system, contact Andrew Cecala to receive information on filing a petition for modification.

This pamphlet and the enclosed video describe a safe, effective and economical method for removing dust from work clothes. Background Information Dusty work clothes can increase a worker s exposure to respirable dust. Respirable dust is usually considered to be particles having an aerodynamic diameter of 10 microns or less and able to enter and deposit in the gas-exchange region of the human lung. A former U.S. Bureau of Mines report documented a 10-fold increase in worker dust exposure on a number of separate occasions from dusty work clothes.* It was found that once clothes become contaminated, they are a continual dust source until cleaned. The only MSHA-approved method to clean work clothes requires a HEPA-filter vacuuming system which is very time consuming and difficult to perform effectively. Therefore, most workers use a single air hose (not MSHA-approved) which can elevate dust levels for the worker, co-workers, and the work environment. A substantial amount of engineering technology has been developed that, when applied, can significantly lower respirable dust exposures of workers at mineral processing plants. But even with these improvements, some workers continue to exceed their permissible exposure limit. Elevated exposures increase the potential for developing debilitating or fatal lung diseases. The clothes cleaning method described within is an example of a continuing effort to reduce the potential for developing these lung diseases. Information about engineering research by the former U.S. Bureau of Mines and NIOSH can be found online at www.cdc.gov/niosh. This website can also be used for obtaining NIOSH information about health hazards associated with crystalline silica. * Cecala, A.B. & E. D. Thimons. Impact of Background Sources on Dust Exposure of Bag Machine Operator. BuMines IC 9089, 1986, 10 pp. 1

2 Crystalline Silica and Health Risks Crystalline silica is the combination of silicon and oxygen, chemically uncombined with any other element, where the atoms are arranged in a repeating 3D crystalline structure. The mineral quartz is the most common form of crystalline silica. This unique mineral has shaped human history since the beginning of civilization and has been used in glass; ceramics (china, porcelain, cookware, floor and wall coverings); fiberglass; water filtration; and to make steel. There are no known substitutes for this mineral. The International Agency for Research on Cancer (IARC) currently ranks crystalline silica as a Group 1 substance, meaning that if inhaled in the form of quartz or cristobalite from occupational sources is carcinogenic to humans. Silicosis Silicosis is a lung disease resulting from occupational exposure to silica dust. Silicosis causes slowly progressive fibrosis of the lungs, impairment of lung function, and tuberculosis. Crystalline silica of respirable size is primarily quartz dust occurring in industrial and occupational settings in the form of fine, breathable particles. Intense exposure to silica dust can lead to rapid onset of silicosis. In Gauley Bridge, WV, in the 1930s, 764 workers died within months of exposure while digging the Hawk s Nest tunnel. This incident is widely regarded as the worst silica-related industrial disaster, and it brought silicosis to the nation s attention. Silicosis can progress even after a person is no longer exposed to the dust, causing severe shortness of breath years later. The more years of exposure to dust, the greater the risk of the disease. Because there is no effective treatment for silicosis, prevention through exposure control is essential. Managing the dust and preventing the inhalation of particles are critical to reducing the risk of silicosis.

3 Project History The Unimin Corporation plant in Marston, NC, grinds silica sand to a fine size. Tools and other equipment utilized to maintain this milling operation often The Clothes Cleaning Process has been become coated with a cooperative research effort with NIOSH finely ground silica dust. that Unimin Corporation has been The plant s solution to pleased to be involved with... clean this equipment was to construct a booth where --Andy O Brien, CSP compressed air could safely be UNIMIN Health & Safety used. The booth was constructed to accommodate down-draft ventilation, and the exhaust (containing the dust) was routed directly to the baghouse dust collector. The equipment cleaning system worked so well that the plant safety and health team suggested that the booth be modified so employees could clean their work clothes along with their tools. The intended result of this clothes cleaning process was to further reduce the potential dust exposure to employees in an already very clean facility. In devising this clothes cleaning method, NIOSH researchers evaluated the effectiveness and time required to perform the existing methods: HEPA-filter vacuuming and a single-nozzle air hose (a method not approved by MSHA). As an alternative, several configurations of an air nozzle manifold were tested both in the laboratory and on-site using crushed limestone dust and coveralls made of cotton and a cotton-polyester blend. All subjects entered the booth wearing a fit-tested 1/2-face respirator equipped with N100 filters along with eye and ear protection. Respirable dust levels inside the respirators were below the Permissible Exposure Limits and the NIOSH-recommended exposure limits. Results indicate that the manifold cleaned the clothes 10 times faster and removed approximately 50% more dust than the commonly used single air hose or vacuuming methods. Average cleaning time (inside the booth) was less than 20 seconds.

The Cleaning Process Booth Dimensions figure 1. Layout and design of booth used in this study. 4 The excess capacity of the baghouse in the Marston plant determined the size of the booth used. For operations with different capacities, a smaller booth may be used thus lowering the cost.

Air Spray Manifold Design * * figure 2. Design of the air manifold system. The air spray manifold consists of a piece of schedule 40 steel pipe, capped at the base. The cleaning process starts when the worker presses the electrical start button which actuates a time-controlled pneumatic valve, allowing air to flow to the manifold. The timecontrolled valve is set for 18 seconds, which is ample time for the worker to rotate in front of the manifold. The valve has a safety interlock option, which automatically shuts off the air supply to the manifold if the exhaust ventilation system fails to keep the booth under sufficient negative pressure. Twenty-six air nozzles are mounted along the manifold, spaced on 2-inch centers. The manifold was drilled and tapped to 1/4 NPT to accept these air nozzles. The bottom nozzle is a circular design located 6 inches from the floor. *Vendor information provided does not imply endorsement or sponsorship by NIOSH or Unimin; it is furnished to provide cost estimates and comparison data. 5

Each of the top 25 nozzles (flat fan design - No. AA727-23), are 17/8-inches in width, which maximizes the effective cleaning width per nozzle. The bottom air nozzle (circular design - No. AA707-23), is mounted with a ball-type fitting and directed downward. During laboratory testing, this circular design was more effective when cleaning at greater distances and thus would be better suited for cleaning the worker s boots. It is recommended that a side barrier be installed to protect the air spray nozzles, since the top 25 nozzles extend 31/8 inches from the supply pipe and could easily be broken off if struck forcefully. During field testing, 1-inch wood sheeting was used along both sides of the nozzles, providing an effective barrier to minimize the potential for nozzle damage. Compressed Air Volume Required At 30 psi, 26 nozzles* expel 144 cubic feet of air from the reservoir tank in less than 20 seconds. The user must ensure that there is adequate pressure from the receiver tank (see table 1). table 1. AIR RECEIVER CAPACITIES TANK SIZE (inches) TANK SIZE (gallons) GAUGE PRESSURE ON TANK (PSI) 100 150 200 CUBIC FEET TANK CAPACITY 24 x 70 120 125 180 234 30 x 84 240 250 360 467 Exhaust Air Volume The clothes cleaning booth at Unimin s Marston plant measured an exhaust air volume of 4,400 cfm with a negative static pressure of 0.16-inch w.g. in a booth with a volume of 110 cubic feet. It must be noted that while this facility had an excess exhaust air volume available in its baghouse collector, most operations will not have this luxury. The volume delivered by the 26 nozzles must be added to the volume of the booth when calculating the required exhaust volume. Further, 6 * 25 Flat fan nozzles (Spraying Systems #AA727-23) and 1 Circular nozzle (Spraying Systems #AA707-23)

7 Reservoir figure 3. The air flows from the plant s compressed air supply to the reservoir, and from there to the manifold. the exhaust volume must be sufficient to maintain the booth s negative pressure during the operation of the air nozzle manifold, providing a fresh air exchange rate that prohibits leakage into the surrounding work environment. table 2. CALCULATIONS VOLUME OF AIR DELIVERED BY THE AIR NOZZLES FLAT FAN NOZZLES: 25 nozzles X 18.4 cfm/nozzle = 460 cfm CIRCULAR NOZZLE: 1 nozzle X 19.2 cfm/nozzle = 19.2 cfm TOTAL: (460 cfm + 19.2 cfm) X 1 min./60-sec X 18-second cleaning time = 144 cubic feet of air

8 Improved Booth Design Over time, additional design changes, improvements and modifications were incorporated into the clothes cleaning system. The booth remains 48 by 42 inches which provides sufficient space for the worker to rotate in front of the air spray manifold while performing the cleaning process. The booth has been modified to provide a 2-foot opening in the roof where the intake air enters, then flows down through the enclosure before exiting through an air plenum on the bottom back of the booth. As the intake air flows through the booth, it entrains the dust removed from the worker s clothing during the cleaning process and forces it down towards the exhaust plenum and away from the worker s breathing zone. A 240-gallon air reservoir is recommended when multiple workers will need to clean their work clothing within a short period of time. For effective dust removal, it is critical that the cleaning booth be ventilated under negative pressure at all times so as to not allow any dust liberated from the clothing to escape from the booth figure 4. This modification features a number of improvements to the clothes cleaning design to improve the airflow pattern through the booth to minimize potential exposure to the worker during the clothes cleaning process

and into the work environment. In the design stage of this technology, testing validated that an exhaust volume of 2,000 cfm was sufficient to maintain a negative pressure throughout the entire clothes cleaning cycle. A pressure switch should be incorporated into the system which will not allow the air spray manifold to activate unless an acceptable negative pressure is maintained within the cleaning booth. For dust removal from the cleaning booth, in the original design, dust-laden air was exhausted from the booth and filtered by a local exhaust ventilation system. For operations which do not have excess collection capacity, removing the dust from the airstream can be performed using a HEPA filtering system which can be located in ductwork in close proximity to the cleaning booth. Another option for some operations is to duct the dust-laden air outside and then release it at a point where it does not pose a risk to outside personnel or to be recirculated back into the facility. This has been field tested and shown to be a viable option. figure 5. Deflector slide (yellow) to prevent air from nozzles blowing into the face of shorter workers. The air spray manifold was designed for a person 5 feet 10 inches in height. Taller workers will have to stoop and drop their shoulders to effectively clean their upper body. When a person is shorter, the top air nozzles can be covered with deflectors to prevent the air sprays from directly hitting a worker s face. A deflector has been designed for the system that allows a slide to cover a number of the upper nozzles to deflect the air for shorter workers. It should be noted that the air spray manifold can be modified to account for height characteristics of workers at individual operations. 9

10 Care & Maintenance Make sure all air nozzles on the spray manifold are working properly. Check all connections, fittings, valves, and air nozzles for leaks and proper operation. Determine that the cleaning booth is at an acceptable negative pressure. This can be achieved by measuring the air velocity or pressure in the exhaust duct or the static pressure in the booth. Determine that the air pressure does not exceed 30 psi being delivered to the air nozzles. Check receiver tank air pressure to determine that an acceptable air pressure is maintained. Ensure that air inlet and exhaust metal screen are completely open and free of debris.

11 Resources & References Silica and Silicosis Sites on the Internet: NIOSH: http://www.cdc.gov/niosh/topics/silica/default.html MSHA: http://www.msha.gov/s&hinfo/silico/silico.htm OSHA: http://www.osha.gov/dsg/etools/silica/index.html WHO: http://www.who.int/occupational_health/topics/silicosis/en/ National Industrial Sand Association: http://www.sand.org Videos: Stop Silicosis - MSHA #VC-826 Silicosis: A Preventable Disease - MSHA #VC-929 Works Cited: Crystalline Silica Primer, U.S. Bureau of Mines, 1992. http://geology.usgs.gov/pdf/silica.html MedicineNet.com Hawk s Nest Incident Summary, Ashley Lucas and Ariadne Paxton Cherniack, 1999. Impact of Background Sources on Dust Exposure of Bag Machine Operator, U.S. Bureau of Mines Information Circular #9089, 1986.

Clothes Cleaning Process Instructions (as seen on the video) 1. Don required personal protective equipment 1/2-face, fit-tested respirator w/ N100 filter Hearing protection Eye protection (full seal goggles required) 2. Enter booth 3. Press Start button to activate air spray manifold 4. Rotate 5. When time-controlled pneumatic valve turns off the air spray manifold, the worker can exit the booth 12 figure 6. Signage used on the door of the booth indicating the personal protective equipment required.

For more information on the Clothes Cleaning Process contact: NIOSH Office of Mine Safety and Health Research Andrew B. Cecala 412.386.6677 acecala@cdc.gov Delivering on the Nation s Promise: Safety and health at work for all people through research and prevention For more information about occupational safety and health topics contact NIOSH at: 1.800.CDC.INFO (232.4636) email: omshr@cdc.gov www.cdc.gov/niosh/mining Print Design and Layout: David L. Caruso, NIOSH Video Production: Chuck Urban, NIOSH