Why Clinical Alarms are a TOP TEN Hazard

Similar documents
Alarm Management. Objectives

2011 National Clinical Alarms Survey: Perceptions, Issues, Improvements and Priorities

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

You finally make it home after a long shift, shower,

The Joint Commission's National Patient Safety Goal on Alarm Management: How Do We Get Started?

Impact Of Clinical Alarms On Patient Safety. American College of Clinical Engineering Healthcare Technology Foundation (AHTF)

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

Managing Clinical Alarms

Improving Alarm Management Utilizing Technology. NJ/DVHIMSS Annual Fall Event. Empowering the New Healthcare Era

Focus on Respiratory Care & Sleep Medicine Irvine, CA. Alarm Management. September 14-15, 2018

Hospital Ward Alarm Fatigue Reduction Through Integrated Medical Device Instruction and Hospital System Policy

Alarms That Deserve Attention. Mike Rayo 3/29/2016

Clinical Alarm Management Strategies Meaningful Alerts

Reference Case: Avera Heart Hospital Data-Driven Approach Helps Hospital Build Effective Clinical Alarm Management Program

"It's Alarming Simple Steps To Reduce Nuisance Alarms

Ensuring the Effectiveness of Clinical Alarm Systems

Sample Content for the. FlipChart. Example: Medical Facility Emergency Preparedness Guide

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

Clinical Alarm Management. Compendium

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

A Novel Approach to Cardiac Alarm Management on Telemetry Units. Medical Device Alarm Safety in Hospitals Joint Commission Webinar May 1, 2013

LASER SAFETY TRAINING CATALOG LASER INSTITUTE OF AMERICA S MAKE LASER SAFETY YOUR PRIORITY LASER

Star Fire District staridaho.org/government/firedept.php

URGENT - Field Safety Notice Medical Device Correction

Health Care. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

LASER SAFETY TRAINING CATALOG LASER INSTITUTE OF AMERICA S MAKE LASER SAFETY YOUR PRIORITY LASER

2013 Compliance Report RCW 52.33

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

Running head: REDUCING THE HARM ASSOCIATED WITH CLINICAL ALARMS 1

The Complexity of Clinical Alarm Systems

Improving Alarm Response in ICU/CCU

Star Fire District staridaho.org/government/firedept.php

Cl inician Training Packet

Carbon Monoxide Awareness Badge Pack

LASER SAFETY TRAINING CATALOG LASER LASER INSTITUTE OF AMERICA S MAKE LASER SAFETY YOUR PRIORITY.

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

Safety Innovations FOUNDATIONHTSI. Plan, Do, Check, Act: Using Action Research to Manage Alarm Systems, Signals, and Responses

FIRE PLAN. In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required.

Reducing the Risk of Fire for the vulnerable person. London Fire Brigade

The Contra Costa EMS System and Fire Station Closures: Impact and Mitigation

DIAL 911 EMERGENCY PROCEDURES

Active Assailant Training Tool

Ontario Homes for Special Needs Association

Battery Performance Alert

BUSINESS PLAN CEN/TC 215 RESPIRATORY AND ANAESTHETIC EQUIPMENT EXECUTIVE SUMMARY

June 17, Skanray Technologies Pvt Ltd. c/o Ms. Yolanda Smith Regulatory Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

Regulation of Alarm Remote Notification Systems

Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

SAPLING HEALTHCARE SOLUTIONS

PATTERNS OF FIREFIGHTER FIREGROUND INJURIES

1. What does the 3T Heater-Cooler Vacuum & Sealing Upgrade ( 3T V&S Upgrade ) consist of?

Frequently Asked Questions About Carbon Monoxide Detectors

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

Fire Protection and Safety in Tunnels 2017 Overview of tunnelling and technology challenges

Fire FY Performance Plan

An Analysis of Volunteer Firefighter Injuries,

The Memorial Souad Kafafi Medical Center Skills Competency Checklist

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

BUSINESS PLAN: Fire Prevention & Education

Emergency Codes. Student Orientation Centre for Education. Modified September 2017

5/9/2017. Understanding Risk Analysis and Emergency Planning and How They Affect the Design of Emergency Communications Systems

Burton Hospitals NHS Foundation Trust. On: 27 April Review Date: March Corporate / Directorate. Department Responsible for Review:

Hospital Preparedness: A Pilot Program for Radiation Monitoring in Emergency Departments

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Alarm Safety in 2017:

ALCATEL-LUCENT OPENTOUCH NOTIFICATION SERVICE IMPROVE REAL-TIME SITUATIONAL AWARENESS AND PERSONAL SAFETY

FFT Functional Family Therapy Evidence Based. Cost Effective. Sustainable. Family, Youth & Culture Sensitive.

Carbon Monoxide Poisoning

Emergency Response Guide for Laboratories

2017 First Quarter Report

Diagnostics with fieldbus

University of Bristol. Sleep Study Suite. Standard Operating Procedures Version 1 November 2011

Contra Costa County Fire District Station # 69. Battalion 7. November Your station responded to 129 Emergency Calls. Response breakdown

EXTERNAL CARDIAC AMBULATORY TELEMETRY

In the 1940s in Chicago, Illinois, a group of oxygentank technicians began meeting with doctors concerned with lung disease. This group named itself

999 AMBULANCE POLICE

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

Remote Monitoring of Offshore Structures using Acoustic Emission.

Dangerous Assumptions

Electric Shock Drowning

Managing fire safety. What s the risk? Bruce Kirkham Principal Consultant Capstone Ltd

College: Campus: Building: Room #: Building Marshall: # 1 st Responder: # 2 nd Responder: # Cut to 3 3/4 x 11 - white

Emergency Codes Overview

Puritan Bennett 980 Ventilator System Planning for Training Checklist

Emergency Preparedness General Response

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

BeneVision Central Monitoring System. Quick Reference Guide

White Paper Study on Refrigerator Safety and Solving Airflow Problems Are Your Refrigerators Really Safe?

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Meagan Ray, RN Safety Director

AST Guidelines for Best Practices in Alarm Management in the Operating Room

TOPICS IN CODE ENFORCEMENT

Customizing Alarm Limits Based on Specific Needs of Patients

Optimum Room Acoustic ComfortTM (RACTM) can be achieved by using a selection of appropriate acoustic descriptors

Deutsche Bank Securities 27th Annual Health Care Conference

FIRE & SAFETY TRAINING BROCHURE

RESPONSIVE. RELIABLE. RESPECTED. Case Study: A 15-Year Public/Private Partnership Goes the Distance

UO North Campus Conditional Use Permit Project

The workers that they had were the best I had in ages! I was most satisfied with the work and workmanship the crew did.

Transcription:

1

Why Clinical Alarms are a TOP TEN Hazard James P. Keller, Jr., M.S. Vice President, Health Technology Evaluation and Safety jkeller@ecri.org American Heart Association Conference November 6, 2012 2

An Alarming Challenge More and more devices with alarms More and more patients are connected to one or many alarm-based devices 150-400 alarms per patient per day can be typical in a critical care unit Alarm-based devices are not standardized in many institutions Flexible alarm setting features allow for inconsistent use of alarms 3 3

The Consequences are Alarming And Routinely in the News Alarm Fatigue a Concern for New Haven Hospitals. New Haven Register, June 11, 2011 4 4

A Typical Event Patient admitted with chest pain and shortness of breath---was on a monitored unit. At 3:25 am, patient s nurse noticed the leads were off and on checking on the patient found him in the bathroom unresponsive. Resuscitation efforts were unsuccessful. Monitor showed the leads had come off at 2:32 am Alarm Interventions During Medical Telemetry Monitoring: A Failure Mode & Effects Analysis, A Pennsylvania Patient Safety Advisory Supplemental Review, March 2008 5 5

A Steady Flow of Data ECRI Institute s search of FDA Maude database using alarm and death revealed 216 deaths involving physiologic monitor alarms (Jan 2005 - Dec 2010) In 73 of the cases, alarms sounded, but staff silenced them, did not hear them because the volume was too low, or did not respond for another reason The Boston Globe reported on at least 15 alarm-related deaths in Massachusetts over the last six years. (February 13, 2011) 6 6

A Steady Flow of Data Pennsylvania Patient Safety Authority reports: 35 deaths associated with physiologic monitor alarms (June 2004-Dec 2010) 28 involved staff failure (e.g., inadequate response, alarms silenced) 28 specific to telemetry monitoring 14 involved equipment not connected 14 communication problems 14 distractions/interruptions 7 7

Updated from Earlier Research 12 Deaths Connecting Remote Cardiac Monitoring Issues with Care Areas. Pennsylvania Patient Safety Authority 2009 Sep;6 (3): 79-83. 8 8

National Alarm Survey Healthcare Technology Foundation www.thehtf.org 4,278 healthcare professionals surveyed Covered perceptions, issues, suggested improvements, and priorities Major contributors were respiratory therapists and nurses (93% respondents clinical staff) Nuisance alarms disrupt patient care 71% agree or strongly agree http://www.thehtf.org/documents/2011_htfalarms SurveyOverallResults.pdf 9 9

Other Top Ten Considerations Routine ECRI Institute accident investigations in a variety of settings ECRI Institute surveys Some estimates suggest that the actual number of alarm-related deaths is actually ten-fold higher than what problem data shows A complex problem to solve The front page factor 10 10

Typical Case of Alarm Fatigue Ventilator-dependent patient frequent coughing Coughing triggers high-pressure alarm Frequent response to alarm by nurse with no real problem Pressure alarm limit increased to minimize the number of false-positive alarms An accident waiting to happen Patient movement crimps breathing circuit Secretions clog the endotracheal tube Inadequate ventilation (inhalation or expiration) 11 ECRI ECRI Institute Institute 2012 2012 11

Some Questions to Ask Does the nurse understand the purpose of the high-pressure alarm? Was the nurse s competence in ventilator use validated? Does the hospital have a policy for who can and cannot set ventilator alarms? Is there a policy on how ventilator alarms should be set? If so, is it generic or does it consider specific circumstances? 12 ECRI ECRI Institute Institute 2012 2012 12

My Own Alarm Fatigue https://www.ecri.org/blog/lists/posts/post.aspx?id=140 https://www.ecri.org/blog/lists/posts/post.aspx?id=143 13 13

Device Evaluation Perspectives Turning off the alarm at the central station Very low volume settings Alarm escalation not available For a silenced alarm condition no reminder that it has been silenced Inconsistency within the same product line regarding the same alarm function (e.g., for silencing) 14 ECRI ECRI Institute Institute 2012 2012 14

Goals for Improvement Minimize patient safety vulnerabilities Reduce risk Improve the efficiency of alarm notification and response Improve the efficacy of alarm management With buy-in from all stakeholders Support technology improvement/advances 15 ECRI ECRI Institute Institute 2012 2012 15

Example Scenario 32-bed step-down area with alarm integration system: all patients alarms sent to all nurses pagers Alarm Fatigue Underlying Causes Diffuse responsibility for alarm response Assumptions that someone else will respond No alarm escalation plan 16 16

Example Solution Delineate responsibility for alarm response Develop an alarm escalation plan Who receives initial alarm notification for each type of alarm Who receives back-up alarm notification for each type of alarm Time intervals per escalation 17 17

www.ecri.org THANK YOU 18