Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Similar documents
CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

INSTALLATION INSTRUCTION

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MODELS K2EU060A, K4EU090A, & K3EU120A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

INSTALLATION INSTRUCTION-50 Hz

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

VariCool VAV Engineering Guide

INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

C13-Series Engineering Guide

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

VertiCool Aurora Engineering Guide

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

SKYPAK II, 3 Ton Series, gives you a

INSTALLATION INSTRUCTION

SKYPAK II, 3 Ton Series, gives you a

COMMERCIAL AIR HANDLER

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

COMMERCIAL AIR HANDLER

Split System Heat Pumps

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

PACKAGE AIR CONDITIONER

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

Installation, Start-Up and Service Instructions

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Water-Cooled Self-Contained Units

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

technical guide Water-Cooled Self-Contained Units

INSTALLATION INSTRUCTIONS FAS/FHS Series, Package Air Handling Units 6 to 25 Ton Air Conditioners 6to20TonHeatPump

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

40 RM/RMS Packaged Air-Handling Units

CoolSpot Engineering Guide

TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM HEAT PUMP FOUR PIPE SYSTEM DESCRIPTION E*FB180 & 240 F*EH180 & & 20 NOMINAL TONS INDOOR UNIT

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Release September 2009

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

Commercial High-Efficiency Condensing Units

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Commercial High-Efficiency Condensing Units

CWA4 Chilled & Hot Water Fan Coil

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

JCseries EVAPORATIVE CONDENSER. engineering data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 60 HZ MODELS: EF-10 & FF-10

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

INSTALLATION INSTRUCTION

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

EHH SERIES DRAW THROUGH FAN COILS CFM

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

PAJ3. Product Specifications

Installation, Start-Up and Service Instructions

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Installation, Start-Up and Service Instructions

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

SSL & SBS Engineering Guide

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Transcription:

DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The units are shipped as single packages with the blower module mounted on top of the coil module. Tthe blower module can be repositioned in the field to meet almost any installation requirement. The unit is manufactured under ISO 9002 Quality System Certification. The blower module includes the blower wheels and room for a fieldmounted motor and drive. The coil module includes direct expansion coils, 25mm (1 in.) throwaway filters, liquid line solenoid valves for both capacity reduction and pumpdown, thermal expansion valves, distributors and a condensate drain pan. Each evaporator coil is pressurized with air to 2240 kpa (325 psig) and leak tested under water. After the headers are brazed onto the coil and the coil is installed in the unit, the coil is pressurized with a combination of Refrigerant-22 and nitrogen to 1035 kpa (150 psig) for pressure testing and additional leak testing. After the coil is evacuated and dehydrated, it is pressurized with a holding charge of Refrigerant-22 for storage and/or shipping. A supply air plenum, return air grille, steam coil, hot water coil, base section, suspension hardware, blower motors and drive accessories are available for field-installation to provide additional application flexibility. This evaporator blower, applied with a matching condensing unit, will provide years of quiet, efficient and dependable operation. FEATURES APPLICATION FLEXIBILITY - This evaporator blower can be arranged for a variety of air discharge patterns in either the horizontal or the vertical position. The following illustration shows three of the more common installation arrangements. Refer to the unit installation instruction for other possibilities. ISO 9001 Certified Quality Management System The unit can be bottom-supported or ceiling-suspended and can be arranged to meet almost any space or duct requirements. Each unit is available with a choice of blower motors, drive packages plus other accessories to make them suitable for most applications. PART LOAD OPERATION - Each evaporator blower has multiple coils with pre-piped distributors, expansion valves and solenoid valves. They require no field modifications for part load operation. Capacity reduction not only provides economical operation but also maintains more even temperature and humidity levels in the conditioned space. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TABLE OF CONTENTS DESCRIPTION................................... 1 FEATURES..................................... 1 ACCESSORIES.................................. 3 ACCESSORY DIMENSIONS........................ 8 LIST OF FIGURES Fig. # Pg. # 1 COIL CURCUITING - LIQUID LINE.............. 7 2 UNIT DIMENSIONS.......................... 7 3 SUPPLY AIR PLENUM - MODEL 1SP0405........ 8 4 RETURN AIR GRILLE - MODEL 1RG0405........ 8 5 BASE SECTION* - MODEL 1BS0405............. 8 6 HOT WATER COIL* - MODEL 1HW0405.......... 9 7 STEAM COIL* - MODEL 1NF0453............... 9 8 SUSPENSION KIT - MODEL 1HH0451........... 9 LIST OF TABLES Tbl. # Pg. # 1 PHYSICAL DATA - UNIT AND ACCESSORIES.... 4 2 ELECTRICAL DATA.......................... 4 3 SUPPLY AIR BLOWER PERFORMANCE, M 3 /S.... 5 4 SUPPLY AIR BLOWER PERFORMANCE, CFM.... 5 5 BLOWER MOTOR AND DRIVE DATA............ 6 6 HOT WATER CAPACITY, KW / MBH............. 6 7 STEAM COIL CAPACITY, KW @ 14 KPA / MBH @ 2 PSIG.................................... 6 8 ACCESSORY STATIC RESISTANCE PA / IWG.... 6 9 PLENUM PERFORMANCE.................... 6 10 PLENUM PERFORMANCE.................... 6 PRODUCT NOMENCLATURE L 4 E U 2 4 0 A PRODUCT CATEGORY L = Split-system Evaporator Blower FACTORY INSTALLED HEAT A = Cooling Only PRODUCT GENERATION 4 = 4TH Generation PRODUCT IDENTIFIER NOMINAL COOLING CAPACITY 240 = 20 Tons EU = Evaporator Blower Unit 2 Unitary Products Group

FEATURES - CONT. EASY SERVICE - Serviceable expansion valves are provided on every unit. These superior valves are factoryinstalled to provide many years of trouble-free operation. If service is required, it is not necessary to unbraze any joints. PUMPDOWN - Each evaporator blower includes a solenoid valve for non-recycling pumpdown. When the cooling requirement in the conditioned space is satisfied, the refrigerant is pumped into the high side of the system. ACCESSORIES RETURN AIR GRILLE - This decorative, expanded metal grille enhances the appearance of any unit that has no return air ductwork. It is especially recommended for units located within the conditioned space. SUPPLY AIR PLENUM - This decorative, horizontal discharge plenum enhances the appearance and performance of any unit that does not have supply air ductwork. It has the same durable finish as the evaporator blower, is fully insulated, is shipped ready for mounting on horizontal or vertical units and has grilles which may be adjusted to meet the throw and spread requirements of the conditioned space. BASE SECTION - The base section can be used to elevate units off the floor. If desired, outdoor air may be introduced through these sections by cutting an access opening to accommodate the outdoor air duct connection. The base has a durable finish to match the evaporator blower unit. It may have to be insulated for certain applications. SUSPENSION PACKAGE - This accessory can be used to suspend horizontal units from above without interfering with access to the unit. It can also be used for elevating a floormounted unit (either horizontal or vertical) to provide additional height for the installation of a trap at the condensate drain connection. A suspension package can be used with vibration isolators. HOT WATER COIL - A drainable water coil is available for field installation between the blower and the coil modules of both horizontal and vertical units. Since their casings match the dimensions and the finish of the basic units, they become an integral part of the unit after installation. The coil slides out of its casing for easy installation. The coil has copper tubes that have been mechanically expanded into aluminum fins. Both headers are located on the same end of the coil. Each coil is leak-tested at 2240 kpa (325 psig) under water and dried before their connections are capped for storage and shipping. STEAM COIL - A steam coil is available for field installation between the blower and coil modules of both horizontal and vertical units. Since their casings match the dimensions and the finish of the basic units, they become an integral part of the unit after installation. The coil slides out of its casing for easy installation and is pitched in its casing to facilitate condensate drainage. The coil has copper tubes that have been mechanically expanded into aluminum fins. Both headers are located on the same end of the coil. Each coil is leak-tested at 2240 kpa (325 psig) and dried before their connections are capped for storage and shipping. BLOWER MOTORS - Different HP motors are available to meet almost any air delivery requirement. All motors have inherent protection, permanently lubricated ball bearings and get field-mounted within the insulated cabinet of the unit to minimize the transmission of sound to the surrounding space. Power wiring for blower motor is field supplied. DRIVE PACKAGES - Different size pulleys and belts are available to provide a blower RPM range to meet almost any air delivery requirement. Variable pitch motor pulleys can be adjusted to provide the proper blower RPM. All drive packages are rated at least 25% above the nominal HP rating of the blower motor. Two-groove pulleys and two belts are provided on every drive package rated at 5 HP. Unitary Products Group 3

TABLE 1: PHYSICAL DATA - UNIT AND ACCESSORIES Evaporator Coil Centrifugal Blowers Filters (Throwaway) (8 Req d) Component Description Model Rows Deep 3 Rows High 32 Finned Length mm (in.) 2108 (83) Fins per 25mm (1 in.) 13 Tube OD (in.) 9.5 3/8 Face Area m 2 (sq. ft.) 1.7 (18.4) Wheel Dia. x Width, mm (in.) (2 Per Unit) 240 381 x 305 (15 x 12) Size mm (in.) 508 x 559 x 25 (20 x 22 x 1) Face Area m 2 (sq. ft.) 2.2 (24.1) Operating Charge Refrigerant-22 kg (lbs) 3.4 (7.4) Drainable, Hot Water Coil Accessory Non-Freeze, Steam Distributing Coil Accessory Weight Kg (Lbs.) Accessory Operating Weight (Lbs.) 1. Less Motor and Drive. Rows Deep 2 Fins per 25mm (1 in.) 8 Tube OD mm (in.) 12.7 (1/2) Face Area m 2 (sq. ft.) 1.35 (14.5) Supply/Return (Copper) OD mm (in.) 34.9 (1-3/8) Rows Deep 1 Fins per 25mm (1 in.) 8 Tube OD mm (in.) x ID mm (in.) 25 (1) x 15.9 (5/8) Face Area m 2 (sq. ft.) 1.3 (13.5) Inlet/Outlet (Brass) NPTEmm (in.) 38.1 (1-1/2) Shipping 1 313 (690) Operating 363 (800) Motor & Drive 3 HP 41 (90) 5 HP 54 (120) Supply Air Plenum 68 (150) Base 54 (120) Return Air Grille 7 (15) Steam Coil 68 (150) Hot Water Coil 68 (150) 3 TABLE 2: ELECTRICAL DATA Motor Rating 3 HP 5 HP Power Supply Nameplate Amps MCA Max. Fuse 1 / Breaker 2 Size (Amps) 380-3-50 5.4 6.8 15 415-3-50 5.2 6.5 15 380-3-50 9.0 11.3 25 415-3-50 8.7 11.0 25 1. Dual element, time delay fuses. 2. HACR type per NEC. 4 Unitary Products Group

TABLE 3: SUPPLY AIR BLOWER PERFORMANCE 1, m 3 /s RPM (Pa) AIRFLOW 3.0 m 3 /s 3.4 m 3 /s 3.8 m 3 /s 4.2 m 3 /s 4.5 m 3 /s (Pa) (Pa) (Pa) (Pa) 600 62 1.04 1.2 25 1.27 1.5 - - - - - - - - - 700 141 1.34 1.8 107 1.56 1.8 64 1.79 2.1 15 2.09 2.4 - - - 800 236 1.71 2.0 206 1.94 2.3 166 2.16 2.5 124 2.53 2.9 74 2.98 3.5 900 332 2.09 2.4 305 2.38 2.8 270 2.76 3.2 233 3.20 3.7 186 3.73 4.3 1000 432 2.53 2.9 404 2.98 3.5 374 3.50 4.1 340 4.02 4.7 - - - 1. Unit resistance is based on a wet evaporator coil and clean filters. 2. Available ESP (external static pressure) in kpa/iwg to overcome the resistance of the duct system and any accessories added to the unit. Refer to the blower motor and drive data table and the accessory static resistance table for additional information. 3. Motors can be selected to operate into their service factor because they are located in the moving air stream, upstream of any heating device. Units with steam or hot water coils are the only exception. On these units, the kw/bhp must not exceed the nominal HP rating of the motor. 5 HP Motor Required TABLE 4: SUPPLY AIR BLOWER PERFORMANCE 1, CFM RPM* (iwg) AIRFLOW 6400 CFM 7200 CFM 8000 CFM 8800 CFM 9600 CFM (bhp) (iwg) (bhp) 1. Unit resistance is based on a wet evaporator coil and clean filters. 2. Available ESP (external static pressure) in kpa/iwg to overcome the resistance of the duct system and any accessories added to the unit. Refer to the blower motor and drive data table and the accessory static resistance table for additional information. 3. Motors can be selected to operate into their service factor because they are located in the moving air stream, upstream of any heating device. Units with steam or hot water coils are the only exception. On these units, the kw/bhp must not exceed the nominal HP rating of the motor. *Min./Max. speed for 3 HP drive accessory is 615/795 RPM. Min./Max. speed for 5 HP drive accessory is 740/902 RPM. (iwg) (bhp) (iwg) (bhp) (iwg) (bhp) 600 0.25 1.4 1.2 0.10 1.7 1.5 - - - - - - - - - 700 0.57 1.8 1.6 0.43 2.1 1.8 0.26 2.4 2.1 0.06 2.8 2.4 - - - 800 0.95 2.3 2.0 0.83 2.6 2.3 0.67 2.9 2.5 0.50 3.4 2.9 0.30 4.0 3.5 900 1.34 2.8 2.4 1.23 3.2 2.8 1.09 3.7 3.2 0.94 4.3 3.7 0.75 5.0 4.3 1000 1.74 3.4 2.9 1.63 4.0 3.5 1.51 4.7 4.1 1.34 5.4 4.7 - - - 5 HP Motor Required Unitary Products Group 5

TABLE 5: BLOWER MOTOR AND DRIVE DATA Drive Accessory Model No. Motor Blower Pulley Motor Pulley Belt RPM Range HP 1 Frame Shaft Size Mfgs. No. Size Mfgs. No. Size 1LD0451 616-798 3 56 7/8 A52 AK84 8 x 1-3/16 1VM50 3.4-4.4 x 7/8 1LD0452 740-902 5 184 1-1/8 A57 2 AK114 11 x 1-3/16 2VP71 5.2-6.2 x 1-1/8 1. All motors are 1450 RPM and have a 1.15 service factor. 2. Two matched belts. TABLE 6: HOT WATER CAPACITY 1, kw / MBH Hot Water Coil Accessory Unit Model Ls / GPM CFM 1HW0405 240 2.2 / 35 1. These capacities do no include any blower motor heat. NOTE: Water Temperature Drop ( F) = 2 x MBH / GPM. Entering Water Temp. Minus Entering Air Temp., C/ F 70 90 110 130 150 3.0 / 6400 52 / 179 67 / 229 82 / 280 97 / 331 112 / 382 3.8 / 8000 58 / 199 75 / 255 91 / 312 108 / 369 124 / 425 4.5 / 9600 64 / 220 83 / 282 101 / 344 122 / 407 137 / 469 Hot Water Coil Accessory 1HW0405 Ls / GPM Pressure Drop1 PSI Capacity Correction Factory.95 / 15 0.2 0.74 2.2 / 35 0.8 1.00 3.5 / 55 1.5 1.04 4.7 / 75 2.5 1.06 1. For pressure drop in feet (water), multiply these values by 2.31. CAUTION: Do NOT operate a supply air blower motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. Do NOT use steam in these hot water coils. TABLE 7: STEAM COIL CAPACITY 1, kw @ 14 kpa / MBH @ 2 PSIG 2 Steam Coil Model Unit Model m 3 /s / CFM 1NF0453 240 1. These capacities do not include any blower motor heat. 2. Multiply these capacities by the following factors to correct for higher steam pressures. Dry Bulb Temperature Of Air Entering Coil, ºf -12 / 10-1 / 30 10 / 50 21 / 70 3.0 / 6400 120 / 402 107 / 364 95 / 325 84 / 286 3.8 / 8000 136 / 464 123 / 419 110 / 374 97 / 330 4.5 / 9600 141 / 481 128 / 435 114 / 388 100 / 342 Steam pressure, kpa/psig 35 / 5 70 / 10 105 / 15 140 / 20 175 / 25 Capacity correction factor 1.05 1.12 1.19 1.25 1.30 NOTE: Steam rate (lbs./hr) = 1.025 x MBH CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. Although these coils are suitable for much higher pressures, steam above 25 psig will provide too much heat and could damage the blower motor. TABLE 8: ACCESSORY STATIC RESISTANCE Pa / IWG m 3 /s / CFM Supply Air Plenum Return Air Grille Non Freeze Steam Coil Hot Water Coil 3.0 / 6400 7.4 /.03 9.9 /.04 34.7 /.14 17.4 /.07 3.4 / 7200 7.4 /.03 12.4 /.05 42.2 /.17 19.8 /.08 3.8 / 8000 9.9 /.04 14.9 /.06 52.0 /.21 24.8 /.10 4.2 / 8800 12.4 /.05 17.3 /.07 62.0 /.25 29.8 /.12 4.5 / 9600 14.9 /.06 19.8 /.08 72.0 /.29 34.7 /.14 TABLE 9: PLENUM PERFORMANCE Throw, Meters / Feet m 3 /s / CFM Minimum Maximum 3.0 / 6400 24 / 80 44 / 145 3.8 / 8000 30 / 98 50 / 165 4.5 / 9600 35 / 115 56 / 185 6 Unitary Products Group

FIGURE 1 - COIL CURCUITING - LIQUID LINE 58 2-5/16 All dimensions are in millimeters and inches. They are subject to change without notice. Certified dimensions will be provided upon request. 679 26-3/4 749 518 29-1/2 20-3/8 70 2-3/4 70 2-3/4 70 2-3/4 70 2-3/4 FIGURE 2 - UNIT DIMENSIONS A B C D E F G H J K L M N P 2273/89-1/2 215985 664/26-1/8 749/29-1/2 1499/59 62/2-7/16 403/15-7/8 316/12-7/16 527/20-3/4 406/16 406/16 527/20-3/4 25/1 41/1-5/8 ACCESSORIES Heating Coil - Add 154mm (6 in.) to overall unit height when used. Plenum - Add 625mm (24-5/8 in.) to overall unit height when used. Base - Add 594mm (23-3/8 in.) to overall unit height when used. APPROXIMATE SHIPPING WEIGHT (Less Motor and Drive) LEU240-363 kg CLEARANCES 610mm (24 in.) on one side for piping connection and access to blower motor. 25mm (1 in.) on opposite side. 25mm (1 in.) on rear. Unitary Products Group 7

ACCESSORY DIMENSIONS 138 5-1/2 32 1-1/2 438 17-1/4 610 24 457 18 625 24-5/8 92 3-5/8 100 3-15/16 953 37-1/2 168 6-5/8 227 89-1/2 953 37-1/2 76 3 781 30-3/4 76 3 SHIPPED KNOCKED DOWN FOR FIELD ASSEMBLY 100 3-15/16 FIGURE 3 - SUPPLY AIR PLENUM - MODEL 1SP0405 2273 89-1/2 749 29-1/2 16 5/8 FIGURE 4 - RETURN AIR GRILLE - MODEL 1RG0405 594 23-1/8 SHIPPED KNOCKED DOWN FOR FIELD ASSEMBLY 2273 89-1/2 781 30-3/4 *Ventilation air can be brought into the unit through the base section providing the base section is fully insulated in the field. FIGURE 5 - BASE SECTION* - MODEL 1BS0405 8 Unitary Products Group

35 1-3/8 35 1-3/8 86 6-3/4 171 2273 6-3/4 89-1/2 781 30-3/4 FIGURE 6 - HOT WATER COIL* - MODEL 1HW0405 51 2 98 3-7/8 76 6 54 2-1/8 *Coil is field-installed between the evaporator coil and the blower section of the unit. 38 1-1/2 38 1-1/2 76 6 64 2-1/2 2273 89-1/2 10 2 381 15 781 30-3/4 51 2 *Coil is field-installed between the evaporator coil and the blower section of the unit. FIGURE 7 - STEAM COIL* - MODEL 1NF0453 127 5 1397 55 1111 40-3/4 1111 43-3/4 76 3 BASIC UNIT SUSPENSION WGTS, kg/lbs Suspension Point w/3 HP Motor* A 64.4 / 142 B 59.8 / 132 C 68.9152 D 73.5 / 162 E 56.8 / 132 F 57.6 / 127 Total Weight 38.1 / 847 *Motor location at suspension point F. FIGURE 8 - SUSPENSION KIT - MODEL 1HH0451 Unitary Products Group 9

10 Unitary Products Group

Unitary Products Group 11

Subject to change without notice. Printed in U.S.A. 293941-XTG-A-0307 Copyright by Unitary Products Group 2007. All rights reserved. Supersedes: 262987/036-21164-001-B-0206 Unitary 5005 Norman Products York OK Group Drive 73069