FSTRONIC AND FSTRONIC 24 CONTROLS FOR DRIVES OF SLIDING AND SECTIONAL FIRE DOORS

Similar documents
CONTROL DEVICE SLIDETRONIC HD

Control box FSTronic DES-FS

Control box FSTronic DES-FI

FirePro control MANUAL

Installation instructions

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Fire Control Panel FS4000

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Instructions for the fan motor control system, SILVER C

1.7. Insulation fault evaluators EDS460/490 EDS461/491

TCM-2 Thyristor Control Module DATA SHEET

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Beacon 800 Gas Monitor Operator s Manual

UV - Monitor UVT 16. Use. Description

SCHMIDT LED Measured Value Display MD Instructions for Use

Gate Operator. Modfications

M2500 Engine Controller Installation Manual

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

WARNING FIRE DOOR CLOSING

EVO192 v3.0 Fire and Burglary What s New

DOCUMENTATION IPS640

Instructions for the fan motor control system with integrated wiring terminals SILVER C

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

10yr O2NE & Safe-Ox. User Manual

Insulation fault evaluator EDS460-DG

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

BSR Addressable Fire Detection control panel. Installation operation manual

OPERATION MANUAL Gas Alarm Processing Unit GAZ 203 VN VN 10

M2000 Engine Controller

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

G34 AU1B (External Ultrasonic Sensor) Version 3

DOCUMENTATION IPS640

M1000 Alarm Annunciator

Model 17A00 Expansion Enclosure

INFRARED MODULATED BARRIERS

User Manual 120/240/300 Outdoor Motion Detector

QD6310. Fixed Gas Detector Operation Manual

EC3-X33 Stand-alone Superheat Controller Technical Data

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

User Guide. OPTYMA TM Control Three-phase AK-RC 103

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

DIESEL Engine Fire Pump Controllers Features

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

All-In-One Wireless Security System V1.0. Model #: MG-6060

Introduction. OM-THA2

Pioneer-R16 Gas Monitor Operator s Manual

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

INSTALLATIONN GUIDE & OPERATION MANUAL

SECTION AUTOMATIC TRANSFER SWITCHES

FLAMA USER S AND INSTALLER S MANUAL

SERVICE MANUAL REFRIGERATION

Interface and EOL Modules 8

VACUUM CONTACTOR TYPE SVC-T 32. 7,2 kv A MANUAL FOR MOUNTING, OPERATION AND MAINTENANCE

SAFETY WARNINGS. isolated cables with minimum cross-sectional area of 0,75 mm for 230V power supply must be used.

ELECTRONIC PANEL LRX 2035 ALARM

5, SE GÅNGHESTER,

AL600ULADA. NAC Power Extender. Installation Guide

Fire Control Panel FS4000

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

Installation Instructions

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

FIL-SPL Flow-through heater for central heating USER MANUAL

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

CTT8 TEMPERATURE MONITOR DEVICE

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Conventional Fire Alarm System 2014 V1.2

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

HX-80NRAM. High Mount Outdoor Detector

SAFETY WARNINGS. Power cable to the alarm system. Automatic two-pole circuit breaker. Cable from power distribution board

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Memcom Emergency Telephone

USE AND INSTALLATION HANDBOOK

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Transcription:

FSTRONIC AND FSTRONIC 24 CONTROLS FOR DRIVES OF SLIDING AND SECTIONAL FIRE DOORS Producer: Somati system s.r.o. Jihlavská 510/2c 664 41 Troubsko, okr.brno - venkov Tel.: 547 427 011 Fax: 547 427 013 E-mail: export@somati-system.cz www.somati-system.cz 5/2015

List of documentation: 1 POWER SUPPLY... 1 2 CONFIGURATION... 1 3 INSTALLATION AND SETUP... 2 4 DESCRIPTION OF CONTROLS AND TERMINAL BLOCKS... 4 4.1 Description of functions set up on the DIP switch... 4 4.2 Description of function settings on the DIP switch... 5 4.3 Description of control feature functions on the panel... 5 5 CONTROL PANEL... 8 5.1 Control panel description... 8 5.2 Door cycle counter on the control panel... 10 6 REGULAR PREVENTIVE CHECKS... 11 7 ELECTRICAL AND DIMENSIONAL DATA... 12 8 CIRCUIT DIAGRAMS... 13 8.1 Connection of the FSTronic with the GfA FS motor (in control box)... 13 8.2 Connection of the FSTronic with the GfA FS motor (in the motor)... 14 8.3 Connection of the FSTronic with the GfA FS motor (in control box) with terminal... 15 8.4 Connection of the FSTronic with the GfA FS motor (in the motor) with terminal 16 8.5 Connection of the FSTronic 24 with the MFZ FDF motor (in control box)... 17 8.6 Connection of the FSTronic 24 with the MFZ FDF motor (seting limit switches). 18 9 WAY OF CONNECTION OF OPTICAL SEAL SAFETY EDGE (OSE)... 19 9.1 List of components of OSE... 19 9.2 Interconnection... 19 9.3 Activation of OSE functions... 20 10 DECLARATION OF CONFORMITY... 21 5/2015

1 POWER SUPPLY Voltage system: Operating voltage: Motor output voltage: Brake voltage: 3 NPE, 50 Hz, 3 x 400/230 V, TN-S 24 V DC 3 PE, 50 Hz, 400 V AC, TN-C 24 V DC Protection against electrical accidents is provided in accordance with ČSN 33 2000-4-41 by automatic disconnection of the faulty section from the power source and by means of supplementary safety circuits. 2 CONFIGURATION The FSTronic design controls the sliding door drive using an FS (fail-safe) motor manufactured by GfA and in the FSTronic 24 modification an FDF motor manufactured by MFZ for controlling a sliding door drive. FSTronic in combination with the FS motor it ensures gravitational closing of the door in case of an alarm. FSTronic 24 in combination with the FDF motor it ensures closing of the door with an auxiliary battery-powered DC motor in case of an alarm. Both control panels, FSTronic and FSTronic 24, have identical outer dimensions and all the same control features. The only difference is in the internal connection and components. Power to the control circuits is backed up by batteries, thereby enabling the door to remain in open position even during a power outage. The battery also provides power to all supplemental safety features during gravitational (FS motor) or electrical (FDF motor) closing after a power outage. (Closing by gravitational/electrical auxiliary motor will occur if the power supply from the network is not reestablished and the voltage on the battery drops below the threshold of 21.0 V. Closing by gravitational/electrical auxiliary motor will also occur if the battery is depleted below 18.0 V, even if network power is supplied.) Instrumentation is situated on the panel in the FSTronic switchboard, and an instrument wiring diagram is included in the design documentation. The dimensions of the switchboard are 400 x 300 x 130 mm (W x H x D). The inputs and outputs of power and control circuits are led through PG bushings at the bottom of the switchboard. In exchange for control of engine power FS engine brake (brake is energized and keep doors locked in position) connected via an auxiliary (NC) contacts. Move the door "hard" in a wrong position by pressing the contactor must be simultaneously unlocked (disconnect power) FS engine brakes. There was a problem transferring power supply 24 V for brake motor and it happened that did not hold the door in position - unidentifiable error. This is resolved by an additional jumper - bypass the auxiliary contacts on the terminal block for connecting the motor. In addition the new connection terminal 8 ' which is connected with a jumper to terminal 8 - bridged contactor auxiliary contacts. In a situation where it is necessary to operate the door "hard" by the contactors, it is necessary for the manual control to remove this jumper to 8-8 '. The contactors will be stuck as the need to remove the jumper for manual control. Re-commissioning of the 1

control panel to it s normal state to be involved again this jumper to eliminate any error voltage transmission via auxiliary contacts of contactors. 3 INSTALLATION AND SETUP The drive is preset and after connecting the external control elements (controllers and limit switches) it requires only a function check. Pay particular attention to the functionality of the limit switches. Improper mechanical or electrical setup of these switches can damage the door s mechanics. The entire mechanical part of the door installation must be completed during the first installation so that the door will not be mechanically damaged when the motor is turned on. Before first activation, connect only the: - power cable - motor cable - EPS (X2: and X:10) connectors, NC contact (with a disconnected contact, the door still closes gravitationally [electrically from batteries - batteries to the controls. The battery as supplied is disconnected (one battery connector is disconnected); the connector is insulated by a cover which must be removed. Connecting the batteries is absolutely necessary for providing power to the auxiliary DC motor in the FSTronic 24 version. If an alarm is sounded without the batteries being connected, the FSTronic 24 variant will overload the 24 V source and the unit will reset the closing alarm will not function. To maintain proper fire-protection functioning, the batteries must be connected and sufficiently charged so they are able to provide power to the auxiliary DC motor. Do not connect any external controllers or other devices before the limit switches are set up. Automatic operation may commence without restriction if the limit switches are not set up. After the setup of limit positions is tested, other external elements may be connected. The FSTronic control panel includes a switch plate with standard Open and Close buttons. These can be used to open the door in the dead man mode. For automatic operation (one-press start) upwards it is necessary to connect the connectors X2: and X2:3 by a jumper or electronic safety device. In case of a door surface which a person can hold onto or though which an object can be put, it is absolutely necessary for automatic operation to be accompanied by the upper infrared detection safety feature. Downward automatic movement is activated by connecting the lower infrared detector photodetectors to the X2: and X2:2 connectors (lower infrared detector) or the optical sensing strip (OSE) to connectors X2:G, X2:W and X2:B. If the photodetector disconnects (when it is OSE equipped) as the door is closing, then the door will move back and stop. If the lower infrared detector is permanently disconnected (when it is OSE equipped) then the door can be closed in the dead man mode. The lower infrared detector has no effect on opening of the door. It is also possible to connect the safety contact strip of the system to the resistance (8.2 kω) by a closed loop. The function is then the same as for the OSE strip and lower infrared detector. If the contact strip is not connected, then the 8.2 kω resistance must be connected to connectors X2:41 and X2:42. Without the resistance, automatic operation will not function. 2

When the pull switch (X2:8) is activated, the door opens to the top final position and remains there for the time set on the T3 timer (range 3 to 130 seconds). It will then close automatically. With the step-by-step control (X2:7), the door can be opened and closed with a single button. When the button is pressed, the door opens to the final position, or it will stop after being pressed again. When pressed once again, the door closes to the final position or stops when the button is once again pressed. The door can be stopped at any time by pressing the STOP button. When EPS is activated (disconnection between X2: and X2:10), the door is in alarm mode: - FSTronic = the door immediately closes by gravity (if closing delay is not set up, there is a warning light). - FSTronic 24 = the door immediately closes by auxiliary motor (if closing delay is not set up, there is a warning light). During a power outage, the door will remain open until the voltage in the reserve battery drops below the limit of 21 V (time depends upon the condition and charge of the battery), it then will close to the bottom final position as during an alarm. During an alarm closing, the door can be stopped by pressing the STOP button. It will remain stopped so long as the button is pressed. The lower infrared detector or OSE optical sensing strip only stops the closing without moving back. If the lower infrared detector or OSE optical sensing strip is disconnected for more than 10 seconds, the door starts to close again. If the door is closed by the EPS signal, it can in case of emergency be opened to an intermediate position by the Emergency open button (X2:9). The door remains in the intermediate position (set by the additionally available limit switch on the motor intermediate position) for the time set on the T3 timer (range 0 to 130 seconds). It will then close as during an alarm. The warning light does not begin to flash before such emergency opening. The function only applies if a 3 x 400 V network power feed is present. In normal regime, the horn and warning light alert function sets off the horn and warning light for the duration set on the T1 timer (range 0 to 25 seconds) before the door will start to move. The warning light can be disabled by setting the timer to 0. If the warning light and dead man functions are used, it is necessary to hold the button pressed in the required door movement direction and wait the set time of the warning light before until the door begins to move and reaches the desired position.!!! IF ANY FUSE IS TRIPPED, IT IS POSSIBLE TO REPLACE IT AT THE SWITCHBOARD ONLY ONCE! IF IT IS TRIPPED A SECOND TIME, REPLACING IT AGAIN IS NOT PERMITTED!!!!!! IF THE PROCEDURES STATED IN THE TECHNICAL DOCUMENTATION ARE NOT OBSERVED, THE WARRANTY CONDITIONS MAY BE VOIDED!!!!!! IN CASE OF A MALFUNCTION IT IS FIRST NECESSARY TO DETERMINE THE CAUSE OF THE MALFUNCTION AND TO RECTIFY THE SITUATION! ONLY THEN CAN THE TRIPPED CIRCUIT BREAKER OR FUSE BE RESET AGAIN!!!!!! IT IS FORBIDDEN TO INTERFERE WITH THE CIRCUITRY OF THE SWITCHBOARD AND CHANGE THEIR CONNECTIONS. IF THIS 3

CONDITION IS NOT OBSERVED, THE SWITCHBOARD WARRANTY WILL NO LONGER APPLY!!!!!! THE SWITCHBOARD CANNOT BE OPENED BY A PERSON WITHOUT APPROPRIATE TRAINING AND QUALIFICATION IN ACCORDANCE WITH, at minimum, Section 6 of Decree No. 50/1978!!! Operating temperature of the FSTronic switchboard is +10 C to +35 C. If ambient temperature drops below +10 C or exceeds +35 C, the switchboard cannot be operated! In temperatures exceeding +25 C and less than +15 C, the battery life is reduced. In exceptional cases, the FSTronic switchboard can be operated in lower temperatures, to as low as 5 C, but only if input power is permanently connected in order to provide minimal warming of the control circuits. 4 DESCRIPTION OF CONTROLS AND TERMINAL BLOCKS 4.1 Description of functions set up on the DIP switch DIP1 activates signaling of the lower infrared detector on indicating LEDs DIP2 activates signaling of the upper infrared detector on indicating LEDs DIP3 activates automatic closing after opening by pressing the open button on the control panel. When pressed, the open button has the identical function as does the pull switch (i.e., after a time set on the T2 it will close automatically). DIP4 activates shortening of the automatic closing time after the photo-detector is interrupted. If the function is activated and photo-detectors are installed, the door will close immediately after passing through the photo-detector and will not wait until the time T2 passes. DIP5 selects whether the lock on the control panel locks only the panel buttons (open/close) or also all external inputs on the terminal block (remote control...) DIP6 selects the response mode to collision with an obstacle when closing. It is possible to select either 1) that the door will only move back and stop if it collides with an obstacle, or 2) that upon colliding with an obstacle the door will fully open and after passing of time T2 try to close again (5 attempts in total). DIP7 selects whether the motor stop reacts to the bottom limit switch immediately or with a delay ( limit switch overrun ). This is appropriate for use if the bottom OSE safety strip is installed, and due to its sensitivity an undesirable move back occurs when closing into the final position. Actual value of final position overrun: - GfA FS motor with 76/14 gearing and main cylinder diameter 324 mm = ca 20 mm - MFZ FDF motor when set on shaft and main cylinder diameter 168 mm = 25 mm DIP8 selects activation of OSE safety strip signaling. If the OSE safety strip is not connected, it is necessary to disable its signaling on the panel. If conversely the OSE safety strip is connected, then its operation must be activated. 4

4.2 Description of function settings on the DIP switch POSITION OFF ON 1 lower infrared detector signaling switched on switched off 2 upper infrared detector signaling switched on switched off 3 automatic operation of the open button on the panel switched off switched on 4 shortening of closing after passing the photodetector switched off switched on 5 locking external inputs (impulse+pull) switched off switched on 6 obstacle detection during automatic closing opens fully opens partially 7 final position overrun switched off switched on 8 OSE activation switched off switched on 4.3 Description of control feature functions on the panel internal switch plate a) buttons open = door opening stop = stops door movement close = door closing b) key switch lock control lock on the panel in 0 position = the open and close buttons are blocked when alarm is activated by the detectors, turn off and on with the key = alarm reset c) LED switch plate LED (green LED) = network power - normally on, flashing during movement LED (red LED) = OSE - normally off, flashing when OSE is activated LED (yellow LED) = infrared detector - normally off, flashing when infrared detector is activated LED (red LED) error(!) - normally off, flashing if any of the alarms is activated 5

External connectors on the DPS in the unit (terminal block X2) a) input side (top part of the X2 terminal box) connectors marked are common (0V), inputs are activated by connecting to OSE optical sensing strip +(B) +12 V (brown receiver and transmitter) -(W) 0 V (white receiver and transmitter) O(G) output (green receiver and transmitter) 1 +24 V for powering the photocells and external devices 0 V for powering the photocells and external devices 2 lower infrared detector NC contact of the infrared detector for closing 0 V 3 upper infrared detector NC contact of the infrared detector for opening against closing 0 V 4 open NO contact 0 V 5 stop NC contact 0 V 6 close NO contact 0 V 7 impulse NO contact (step by step) 0 V 8 pull NO contact (always opens and, safety features permitting, opens after time-out) 0 V 9 emergency NO contact (after alarm activation opens to intermediate position 1, times out and disengages the brake closes with alarm closing) 0 V 10 EPS NC contact 0 V 11 reset NO contact resets the unit 0 V 12 lock NO contact on the panel if there is a detector alarm, resets 0 V The other inputs are connected to the X1 power terminal block. b) output side (bottom part of the X2 terminal block) 26 warning light 0 V 27 warning light +24 V 28 alarm COM 29 alarm NO 30 alarm NC 31 COM relay (for connectors X2:32 through X2:38) 32 no 230V switched on when network power is present 33 battery power down switched on if battery voltage is above 21.0 V 6

34 safety limit switches switched on if safety limit switches disconnect 35 fall brake switched on when fall brake is activated 36 intermediate position 1 switched on in this position 37 open switched on in this position 38 closed switched on in this position 39 detectors 0V (closed 4.7 kω loop for connecting detectors between X2:39 and X2:40) 40 detectors +24V (closed 4.7 kω loop for connecting detectors between X2:39 and X2:40) 41 contact strip 8k2-0V (closed 8.2 kω loop for connecting contact strip between X2:41 and X2:42) 42 contact strip 8k2 - +24V (closed 8.2 kω loop for connecting contact strip between X2:41 and X2:42) Timers for setting up times T1 time of warning light 0 to 25 s T2 time until automatic closing 3 to 130 s T3 time of emergency opening 0 to 130 s Power terminal block (X1 terminal block) for FSTronic L1,L2,L3,N,PE power feed 3 x 400/230 V TN-S 1,2,3,PE drive motor 4 brake 0 V 5 common for limit switches 6 limit switch intermediate position 1 (emergency) NO 7 limit switch open NC 8 brake +24 V 8 brake +24 V (auxiliary contactor) 9 limit switch closed NC 10 safety limit switch NC 13,14 fall brake NC Power terminal block (X1 terminal block) for FSTronic 24 L1,L2,L3,N,PE power feed 3 x 400/230 V TN-S 1,2,3,PE drive motor 4,5 safety limit switch NC 6,7 limit switch open NC 8,9 limit switch closed NC 10,11 limit switch intermediate position 1 (emergency) NO 12 brake 0 V (220 Ω) 13 brake +24 V (220 Ω) 14,15 fall brake NC 16 auxiliary DC motor +24 V (max. 10 A) 17 auxiliary DC motor 0 V (max. 10 A) 7

5 CONTROL PANEL 5.1 Control panel description A switch plate with Open, Stop and Close buttons is installed for controlling the FSTronic. LED lights on the switch plate display all possible states of the control so the door operator can easily determine the states and possible door alarms. Description of the individual lights: If the light is uninterruptedly on, the control is active. If the light is flashing, the door is moving Normally, the light is off and does not flash. If it flashes, the bottom OSE safety strip has been activated. If the bottom OSE safety strip is not installed it is flashing continually, which can be deactivated by switching DIP 8 to OFF. Normally, the light is off and does not flash. If it flashes, the lower or upper infrared sensor (a security element) has been activated. If the lower infrared sensor is not installed, it flashes continually, which can be deactivated by switching DIP 1 to ON. If the upper infrared sensor is not installed it will flash continually, which can be deactivated by switching DIP 2 to ON. 8

If the light flashes 1x quickly, the lower infrared sensor was activated. If the light flashes 2x quickly, the upper infrared sensor was activated. If the two infrared sensors are activated concurrently, the two states are displayed consecutively, i.e. one flash pause two flashes. Normally the light is off and does not flash. If the light is flashing, one of the alarms has been activated (see below). If the light flashes 1x quickly, EPS was activated. There is a fire alarm either from the central fire signaling or local detectors. If local detectors are installed, to disable the alarm it is necessary to turn off the key switch on the panel and turn it on again. This will RESET the detector. If it is an alarm from the central fire signaling, then the control alarm will be disabled automatically once the central fire signaling cancels the alarm, so there is no need to RESET using the key switch. If the light flashes 2x quickly, there is a power outage of the 3 x 400 V network. If the light flashes 3x quickly, this signals the battery is bad, voltage of the battery cells dropped below 21.0 V. If the light flashes 4x quickly, the safety limit switch has been activated. The door has passed over one of its standard end positions. A service intervention is necessary. The door can only be moved from this position by pushing the KM1 contactor (for movement upward, otevřít ) or KM2 contactor (for movement downward, zavřít ) by hand for such time as needed for the door to move by at least 5 cm. The contactor can only be pushed using a tool ideally a slender insulated screwdriver. This operation may only be performed by a trained and authorized person. In any case, a service intervention must be performed on the door mechanism to determine the cause for activating the safety switch. Activation of the safety limit switch is the most typical cause of 4x flashing diodes. This alarm (4x flashing) can also indicate other alarms of engine, especially the engine thermal cutout - check the surface temperature of the engine - after cooling the engine on operating condition of the engine (see engine parameters) alarm automatically cancel and controls will operate again. Another cause may be the case with the engine MFZ is plugged hand crank for manual control of engine - pull out the crank of engine and controls will operate again If the light flashes 5x quickly, the safety fall brake has been activated. A service intervention is necessary. In this case, the Close button is blocked and the door can only be moved in the direction Open in the dead man mode. To unblock the fall brake, the door must very cautiously be opened by ca 5 cm, which should disengage the fall brake. Further, the micro switch on the fall brake must be deactivated (see the fall brake manual that was supplied). This operation can only be performed by a trained and authorized person. In any case, a service intervention must be performed on the door mechanism to determine the cause of activating the safety fall brake. In case of several concurrent alarms, the individual alarms are displayed by short flashes with a pause in between (For example, 2 quick flashes pause 4 quick flashes means there was a power outage and at the same time the safety limit switch is activated.) 9

5.2 Door cycle counter on the control panel The FSTronic controls have an integrated internal memory which can display the number of completed door cycles. The counter is supplied reset to zero after door installation. After replacing certain components (e.g., the motor) or a total overhaul of the door mechanism, the counter can be reset to zero. This operation is only performed by a trained service technician authorized for such operation (which needs to be entered into the door s service book). Displaying counter number: The number can be displayed if the control (door) is in the stop state not in alarm state. Press the stop button on the switch plate and hold for 10 s 1) All the LEDs will light up momentarily. 2) All the LEDs will turn off. 3) Now the digit positions of the cycle count number will be displayed by the numbers of LED flashes for the individual LEDs, as described below: 4) The LED will light up The LED will flash as many times as there are 100,000s (hundreds of thousands) of cycles. 5) The LED will light up The LED will flash as many times as there are 10,000s (tens of thousands) of cycles. 6) The LED will light up The LED will flash as many times as there are 1,000s (thousands) of cycles. 7) The + LEDs will light up The LEDs will flash as many times as there are 100s (hundreds) of cycles. 8) The + LEDs will light up The LEDs will flash as many times as there are 10s (tens) of cycles. 9) The + + LEDs will light up The LEDs will flash as many times as there are 1s (units) of cycles. The display will automatically return to the normal mode. Indicating the lapse of the service interval: The FSTronic control panel is equipped with an internal memory that will display the passing of the preset service interval by synchronous flashing of all LEDs. The standard preset interval is 2,500 door cycles or 1 year from the last service (or installation). In case the passing of the service interval is signaled, it is necessary to call upon the service organization to perform a service check. The technician will check the door and put the controls back into their standard operating state. Even if signaling of the lapse of the service interval is active, all functions of the controls remain unaffected only the display of alarms is affected by the synchronous flashing of the service interval. 10

6 REGULAR PREVENTIVE CHECKS a) Switchboard Component Check Action performed Cycle Loose screws Terminal block Loose connectors Loose connections Contactor, relay Visual check Tighten Tighten Replace after check 1 year 1 year b) Battery mandatory user maintenance (the risk is a loss of function during a power outage) Component Check Action performed Cycle Battery(ies) FSTronic Battery(ies) FSTronic 24 Time of door held open until b a t tery is d i s c h ar g e d minimally 30 minutes. The guarantee for batteries for safety devices is 1 year. Closing the door by sounding the alarm closing by the auxiliary DC motor minimally 5x in the entire cycle. The guarantee for batteries for safety devices is 1 year. Turn off power supply. If needed, replace the batteries with brand new ones! Turn off power supply. If needed, replace the batteries with brand new ones! 1 year 1 year The FSTronic is equipped with hermetically sealed lead acid batteries. The following instructions should be followed for their safe operation: Proper recharging is a precondition for obtaining the full life from hermetically sealed lead acid batteries (for usual types, this is ca 5 years at an optimal operating temperature of 15 20 C). This is provided by the FSTronic recharging circuit so long as the control panel is powered from the electricity network. In case of a network power outage for more than 2 hours, disconnect the batteries by disconnecting the connector so that the batteries do not discharge themselves in supplying the control panel. The battery connector should be insulated by covering with the plastic cover (see section 3 installation). Under normal operating conditions, the battery is hermetically sealed, nothing should be leaking from the safety plugs and the battery can be operated in any position. In order to ensure the safe function of the seals (e.g. in case of a charger malfunction) it is necessary also to maintain some free space in front of the upper side that has the seals. Extreme discharging also decreases the life of lead acid batteries. When the battery is fully discharged, it even can be damaged. New batteries are supplied partially charged. The optimal storage temperature is 15 20 C. Load must be disconnected when they are in storage! Before storing, it is necessary to charge the battery. During long-term storage at the listed temperature it is appropriate to recharge it after no more than 9 months, and sooner if the temperature is higher. With higher temperature the total life of a lead acid battery significantly decreases. 11

SAFETY INSTRUCTIONS FOR HERMETICALLY SEALED LEAD ACID BATTERIES: Maintain proper polarity do not switch poles, keep contacts clean. Use them only for the electrical appliances for which they were designed. Hermetically sealed lead acid batteries cannot be replaced by common car or motorcycle batteries. If the battery is overcharged even though the original charger is used, that means the charger is damaged. Disconnect the faulty charger immediately and have it repaired by a professional service center. Chargers for common car or motorcycle batteries or chargers for nickel cadmium, nickel metal hydride or other types of batteries must not be used. Protect the batteries from shorts. Do not overload or warm them. Do not place them into fire, open or modify or damage them in any other way. Dispose of old batteries properly at an appropriate collection facility. Batteries damaged through improper use and by not observing the principles stated above are not subject to guarantee! In order to determine the causes of failure for a battery subject to a claim, the seller reserves the right to test the specific operating conditions. If improper conditions are confirmed, the work related to their checking and measuring will be billed. 7 ELECTRICAL AND DIMENSIONAL DATA System 3NPE, 50 Hz, 3x 400/230 V, TN-S Voltage 230 V/50 Hz, max. 50 VA Control voltage 24 Vss. Backup battery 2pcs 12 V/7,2 Ah Cover IP 54 Maximum output power BRAKE (X1:, X1:) 1 A Maximum output power 1 (X2: 1, X2: ) 0,2 A Maximum output power SIREN (X2: 27, X2: 28) 1 A Sum of currents BRAKE, output 1, SIREN max. 1,2 A constantly Output ALARM switching potencial free relay and outputs from X2: 32 to X2: 38 max. 60 Vss./dg., 1 A individually, 5 A overall Output fort the auxiliary engine FSTronic 24 24 Vss./16 A max. you must have charged battery, the motor is powered by 2 batteries from a source, protected by fuses 20 A Panel size H: 40 cm; W: 31 cm; D: 15 cm 12

8 CIRCUIT DIAGRAMS 8.1 Connection of the FSTronic with the GfA FS motor (in control box) SL OT OF SE NS O R SL OT OF SE NS O R 40 39 40 3 13

8.2 Connection of the FSTronic with the GfA FS motor (in the motor) 14

8.3 Connection of the FSTronic with the GfA FS motor (in control box) with terminal SL OT OF SE NS O R SL OT OF SE NS O R 40 39 40 3 15

8.4 Connection of the FSTronic with the GfA FS motor (in the motor) with terminal 16

8.5 Connection of the FSTronic 24 with the MFZ FDF motor (in control box) terminal X2 terminal X2 ter mi na l X1 SL OT OF SE NS OR S 40 39 SL OT OF SE NS OR S 40 3 17

8.6 Connection of the FSTronic 24 with the MFZ FDF motor (seting limit switches) Adjustment of limit switch FDF motor (FTA / FDS) 1) Additional limit switch OPEN green 2) Limit switch OPEN green 3) Safety limit switch OPEN red 4) Safety limit switch CLOSED red 5) Limit switch CLOSED white 6) Additional limit switch CLOSED white 1) Drive the gate to wished CLOSED position. 2) Set the control cam 5 (white) the way that the limit switch is operated. 3) Tighten the fixing screw A. 4) Fine adjustment is done with the screw B. 5) Drive the gate to wished OPEN position. 6) Set the control cam 2 (green) the way that the limit switch is operated. 7) Tighten the fixing screw A. 8) The safety limit switches 3 and 4 (red) must be set the way that they react directly after passing the control limit switch. 9) After the operation test, control the fixing screw. 10) The additional limit switches 1 and 6 have change-over contact free of potential. 18

9 WAY OF CONNECTION OF OPTICAL SEAL SAFETY EDGE (OSE) 9.1 List of components of OSE Connection box with spiral cable Connection box with spiral cable connects control unit FSTronic with plug-in transmitter, which is built-in OSE. Plug-in receiver Plug-in transmitter Rubber OSE Plug-in receiver is a component, which receives optical signal in OSE from the plug-in transmitter. If the signal is interrupted during closing of gate, fire shutter stops and immediately starts to open. Plug-in transmitter is a component, which transmits optical signal in OSE to plug-in receiver. If the signal is interrupted during closing of gate, fire shutter stops and immediately starts to open. Rubber OSE is installed on bottom segment with optical receiver and transmitter. 9.2 Interconnection Transmitter, receiver and spiral cable has to be connected with conductors of the same colour (brown, white, green). 19

White cables from the transmitter and receiver have to be connected in hub with white cable made from spiral cable. We follow the same procedure with green and brown cable as well (always the same colour to the same colour). Plug-in receiver and transmitter (prepared from production) have to be inserted into rubber OSE. Plug-in transmitter is placed on the side of connection box with spiral cable, which is installed on bottom segment (of rolling shutter) or on bottom section (of sectional shutter). Into connection box lead two cables from plug-in transmitter and receiver. Out of connection box leads spiral cable into switchboard FSTronic through bracket with grommet. 9.3 Activation of OSE functions - Necessary to activate on DIP 8 see 4.1. in the manual. - Necessary to connect clips X2: and X3: (input of info-bolt, see point 3 in the manual). 20

10 DECLARATION OF CONFORMITY EC Declaration of Conformity Manufacturer: ID No. CZ29260159 Product: ROLLTRONIC FSTRONIC Designed for controlling fire doors Method of assessing conformity: Tests were performed by the testing lab no. 1063 TESTCOM accredited by the Czech Accreditation Institute which issued the following protocols: On 3 April 2006 protocol no. EB1367-1, electrical safety On 28 April 2006 protocol no. 11/06 electromagnetic compatibility List of technical regulations used in assessing conformity: Government Decree No. 17/2003 Coll., on technical requirements for low-voltage devices, as amended; Government Decree No. 616/2006 Coll., on electromagnetic compatibility, as amended. And the pursuant harmonized Czech technical norms: ČSN -EN60950-1:2003, Č S N - E N 5 0 1 3 0-4 : 1 9 9 9, a m e n d m e n t A 1 : 1 9 9 9, a m e n d m e n t A 2 : 2 0 0 3, Č S N - E N 6 1 0 0 0-6 - 3:2002, ČSN-EN61000-4-2:1997, amendment A1:1990, amendment Z1:2001, ČSN-EN61000-4-3 ed. 2:2003, ČSN-EN61000-4-4:1997, ČSN-EN61000-4-5:1997, amendment Z1:2001, ČSN -EN61000-4-6:1997, amendment Z1:2001, ČSN-EN61000-4-11:1996, ČSN-EN55011:1999, amendment A1:2001, amendment A2:2003 The manufacturer hereby confirms that the properties of the product conform to the basic requirements according to government decrees nos. 17/2009 Coll. (2006/95 ES) and 616/2006 (2004/108 ES) Coll., or the requirements of other technical regulations and that the product is safe under the conditions of the aforementioned use. The manufacturer also has adopted measures to ensure conformity of all the products introduced to the market with the technical documentation and basic requirements. In Troubsko on Ing. Jiří Ruč, Somati system s.r.o. 21