HR150 SERIES DEHYDRATOR USER MANUAL

Similar documents
SAHARA SERIES DryLine DEHYDRATOR USER MANUAL

SAHARA2A-HP SERIES DryLine DEHYDRATOR USER MANUAL

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

MDH Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

Owner s Manual PCS PRO

domnick hunter PNEUDRI DME012-RX - DME080-RX USER GUIDE Original Language

Dual Column Dehydrating Breather Manual

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Environmental Monitoring SmartSlot Card

Heated Desiccant Air Dryer

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

OG5000 Ozone Generator Model OG5000B-A. User Manual

Series: MBC1-TC Mini Benchtop Temperature Controller

Automatic Air Dehydrator with Ethernet Communications Model ADH NETCOM

Dimension drawing. Main feature. Dimension (H x W x D) Cooling capacity *Note. Standalone temperature control. Rated voltage.

Waveguide Dehydrators

HEX200PB Heat Exchanger Instruction Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

P/N CC-100. Coolant Circulator. Operation manual

V LPM Desiccant Air Dryer Installation and Operation Manual

CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

Heatless Desiccant Compressed Air Dryers

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Installation and Operation Manual Low Power (LP) DC Power System

A COMPLETE GUIDE TO OPERATION, TROUBLESHOOTING AND SERVICE PROCEDURES 2005 DRY AIR SYSTEMS Group (04/05)

Automatic Air Dehydrator with Ethernet Communications Model ADH NETCOM

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Panel Mounted Heat Exchangers by Dantherm, Inc.

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

Adsorption dryer PDAD. (en) Operating instructions g [ ]

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

MODEL B2 INSTALLATION MANUAL

Heat of Compression Desiccant Air Dryers. NRG-LES SERIES scfm ( nm 3 /h)

Geotech High Vacuum Sampler

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

HEX050QA Heat Exchanger Instruction Manual

Operating Instructions

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

ID SERIES CABLE DRYER USER MANUAL. Bulletin AE01B-A Date: 6 FEB 07

Operator s Manual. IP-100 Immersion Probe Cooler

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Public Safety DAS Annunciator Panel

OWNERS MANUAL OPERATION GUIDE

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

USER MANUAL WATER DISPENSER WITH ICE MAKER

AD SP. Air Dryer User Manual. Innovation with Integrity. Version 001 NMR

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SITESTAR CABINET DESCRIPTION

Desiccant Air Dryers. Heatless, Heated and Heated Blower

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

P4200PM / P5000PM Remote Air Dryer User s Guide

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

Model OP155 Air Dryer

MODEL MW200 MODEL MW600 AIR DRYER

USER S OPERATING AND INSTRUCTION MANUAL

Model CAC 500M Media Air Cleaner

P6500W Air Dryer User s Guide

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY

MDA-Range of Modular Desiccant Compressed Air System

½ Monitored Pneumatic Valves On Series Ported Manifold

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

PNEUDRI High Efficiency Compressed Air Dryers.

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Technical Manual. Operation and installation cooling units PKS 3000 SERIES 115V / 230V / 460V. Version 1.0, March 2018

Heat of Compression Desiccant Air Dryers. HOC SERIES scfm ( nm 3 /h)

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

48 TAYLOR CEILING FAN

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 14 DEC NOVATEC, Inc All Rights Reserved

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Installation, Operation & Service Manual

Instruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Transcription:

HR150 SERIES DEHYDRATOR USER MANUAL Bulletin AE01B-A0595-001 Rev: A 2014 CommScope, Inc. All rights reserved (06/14) Page 1 of 12

HR150 SERIES DEHYDRATOR USER MANUAL Contents Section 1 General Information... 3 1.1 Introduction... 3 Section 2 Safety Information... 3 Section 3 Equipment... 4 3.1 Supplied Equipment... 5 Section 4 Description... 6 Section5 Installation... 6 5.1 Unpacking... 6 5.2 Mounting... 7 5.2.1 19 Rack Mounting... 7 5.2.2 Wall Mounting... 7 5.3 Electrical Connections... 7 5.3.1 Power Connections... 7 5.3.2 Power Connections... 8 5.4 Pneumatic Connections... 8 5.4 Operation... 8 5.6 Alarms... 8 Section 6 Corrective Maintenance and Spare Parts... 9 Section 7 Outline... 10 Section 8 Customer Service... 11 8.0 Introduction... 11 8.1 In Case of Trouble... 11 8.2 Initial Steps by CommScope... 11 8.3 Repair Center Process... 11 Page 2 of 12

HR150 SERIES DEHYDRATOR USER GUIDE MANUAL Section 1 1.1 Introduction General Information The HR150 is a heat regenerative air dryer. It utilizes redundant compressors and drying canisters to insure a reliable flow of dry air for pressurization of air cable. The canisters automatically regenerate, eliminating the maintenance associated with typical desiccant dryers. The HR150 must be located such that only authorized personnel have access. CAUTION: The HR150 utilizes heat to regenerate the drying canisters. Mount the HR150 at the top of the equipment rack if possible. Should be placed in the top of the equipment rack with nothing mounted above it. Section 2 Safety Information Make sure that the information in this document has been understood by the persons performing the procedures: Electrical Hazard! Unplug power cord before servicing unit. Let unit cool before removing cover. Page 3 of 12

HR150 SERIES DEHYDRATOR USER MANUAL Section 3 Equipment Output Pressure 3 kpa (.44 psig), nominal Maximum Flow Rate 150 lph (5.3 scfh) Safety Valve 7 kpa (1.0 psig) Output Air Dew Point 45 C ( 50 F), nominal Desiccant Regeneration Automatic by heat Regeneration Phase Interval 2 hours heat / 5 hours operation Alarms low pressure, high pressure, high humidity (optional) Low Pressure Alarm 1.5 kpa (0.22 psig) High Pressure Alarm 4.5 kpa (0.65 psig) High Humidity Alarm 10% RH LED Indications Power on, Alarm codes Acoustic Noise 50 dba Enclosure Degree of Protection IP20 Operating Temperature 5ºC to +50ºC (+23ºF to + 122ºF) Storage Temperature 40ºC to +70ºC ( 40ºF to +158ºF) Power Supply Std. 48 / 60 V DC Power Consumption <45 W Dimensions 2 RU (428 mm x 87 mm x 234 mm) (16.85 in x 3.43 in x 9.21 in) European Community Directives CE Safety Normative ETSI EN 60950 1 ANSI/UL 60950 1 CAN/CSA C22.2 No. 60950 1 07 Electromagnetic Compatibility Normative ETSI EN 301 489 1 ANSI CFR 47 Part 15 Quality Assurance Std. ISO 9001 Weight 4.8 kg (10.58 lbs) Output Pneumatic Connector 4 each 3/8 Compression Fittings Page 4 of 12

HR150 SERIES DEHYDRATOR USER GUIDE MANUAL 3.1 Supplied Equipment Item QTY Description A 1 HR150 Dehydrator B 2 Mounting Brackets B1 6 M4x10 PPH Screws, SST, Pass B2 6 M4 Flat Washer, SST, Pass C 1 Power Cable D 30.5 m 100 ft 9.5 mm (3/8 ) Output Tubing Additional Accessories (sold separately) HR150 KIT ETSI HR150 KIT ACDC HR150 ETSI N3 RACK BRACKETS KIT HR150 AC TO 48 V DC POWER CONVERTER KIT Page 5 of 12

HR150 SERIES DEHYDRATOR USER GUIDE MANUAL Section 4 Description The HR150 dehydrator system is designed for continuous automatic operation. It is a heat regenerative desiccant dehydrator designed to operate on 48 / 60 V DC. The desiccant automatically regenerates by periodic heating and requires no scheduled maintenance. It will supply up to 150 liters per hour (5.3 scfh) of air with a dew point of better than 45 C ( 49 F) at a nominal pressure of 3 kpa (0.44 psig). The HR150 is designed for mount in a standard 19 equipment rack and has an option for ETSI N3 rack mounting with adapter plates (sold separately). The HR150 requires 2 rack units to mount. Section5 5.1 Unpacking Installation J2 Alarm Connection 4 OUTPUT PORTS 48/ 60 DC POWER CONNECTOR Dry air is supplied to the transmission lines by four independent outlets located on the rear of the chassis. Ambient air is drawn through desiccant beds by two low power diaphragm compressors. The adsorbent material in the desiccant canisters removes moisture from the ambient air prior to passing it through the internal manifold where the system pressure and humidity level (optional) is monitored. System pressure dictates demand and the HR150 will respond by changing the speed of the compressors allowing the dehydrator to function without pressure switches or regulators. This increases compressor life and overall unit reliability. The HR150 includes all necessary brackets and electrical terminations to successfully install the unit in a site. Installation of the HR150 requires the following tools: #1 and #2 Phillips head screw drivers Wire cutters and wire strippers for alarm terminations Page 6 of 12

HR150 SERIES DEHYDRATOR USER MANUAL 5.2 Mounting CAUTION: The HR150 utilizes heat to regenerate the drying canisters. Mount the HR150 at the top of the equipment rack. The heat created by the HR150 is dissipated out of the top and side of the dehydrator. DO NOT mount any equipment above the HR150. 5.2.1 19 Rack Mounting enough clearance for the tubing and electrical connections. Secure the unit to the wall using appropriate fasteners for the wall material. The hardware for mounting to the wall is not included. Attach the supplied rack brackets with the included screws to the front mounting holes for installation in a standard 19 equipment rack as illustrated below. The hardware necessary for mounting to the equipment rack is not included 5.3 Electrical Connections Caution: The ON/OFF switch on the front must be switched off prior to disconnecting the dehydrator from the power supply prior to servicing. A protective earth terminal is available through the power connector J1 and is marked by the Earth Ground symbol. Additionally, there is an external ground stud that can be used for additional electrical protection. 5.2.2 Wall Mounting Install the standard 19 rack brackets on the rear of the chassis with the included screws as illustrated below. The brackets will provide 5.3.1 Power Connections Verify that the power supply is the correct type and rated voltage prior to connecting the HR150. See power ratings label on rear side of the dehydrator. The power cable comes pre terminated for connection to J1 on the rear of the dehydrator. The HR150 incorporates reverse polarity protection. If the unit does not power up when connected to the DC supply, verify polarity and correct if necessary. The supply end of the Page 7 of 12

HR150 SERIES DEHYDRATOR USER MANUAL power cable is left un terminated to accommodate any type of power supply. If the proper DC power supply voltage is connected to the dehydrator and the power switch is turned on but the unit fails to operate, verify the polarity. If the polarity is incorrect, have it reversed and then re connect to the dehydrator. The HR dehydrators are equipped with reverse polarity protection, but will not operate under reverse polarity. Polarity for the power cable is: Red Positive Black Negative White Ground The first compressor will start and air will begin flowing to the transmission line(s) ). If thiss is a new installation, the transmission lines must be purged by creating a small leak at the far end of the transmission lines and allowing the dehydrator to pump dry air through them. A minimum of threee air volume exchanges is required. If the installation is located in a very humid area, up to twelve air exchanges may be necessary to properly purge the transmission line. The time, in hours, necessary to exchange the air one time is based on the total air volumee (V) off the waveguide and antennaa system. Purging time (hours) = (3 x V) / 150, where V is line volume in liters At the conclusion of the purging cycle, close the far end of the transmission lines. 5.3.2 5.4 Alarm Connections Alarm wiring will need to be provided by the customer at the installation site. Pneumatic Connections The HR150 has a quantity of four 9.5 mm (3/8 in) compression fittings located on the rear of the chassis. The dehydrator is shipped with one port open to ambient air. The other three ports are plugged with pressure caps in order to prevent air from escaping from these ports when not in use. In order to use these additional ports, simply remove the pressure caps. 5.6 Alarms The HR150 is equipped with an LED on the frontt panel for a visual indication of alarm conditions.. A green LED indicates all is well with the dehydrator. A solid or blinking amber LED indicates a problem with the dehydrator. 5.4 Operation Connect the included tubing to an open port on the rear of the unit. All unused ports must be plugged with pressure caps. Turn on the power switch located on the front face. The LED will illuminate. Page 8 of 12

HR150 SERIES DEHYDRATOR USER MANUAL Blinks Alarm Description Solid Amber 1 2 3 System Failure High Humidity (optional) Low Pressure High Pressure Indicates a failure of the controller. Replacement will be necessary. Indicates output air is above 10% RH. This can be caused by long storage periods and should clear in the first 24 hours of operation. Indicates a system pressure lower than alarm threshold. Indicates a system pressure higher than alarm threshold. If multiple alarms exist at the same time, they will blink in sequence with approximately two seconds between. Section 6 Corrective Maintenance and Spare Parts The HR150 is designed to be maintenance free. If you experience any issues with the HR150, please contact CommScope. See Section 8 for additional information. ALARM SYMBOLS Front of Chassis ALARM OUTPUT WIRES COLORS BLACK (NO) WHITE (COM) RED (NC) Rear of Chassis Page 9 of 12

Section 7 Outline HR150 SERIES DEHYDRATOR USER MANUAL Outline without mounting brackets Outline for 19 rack and wall mounting Outline side view Outline side view wall mounting Page 10 of 12

Section 8 8.0 Introduction Customer Service CommScope provides in warranty and out ofwarranty repairs as well as dehydrator and compressor overhauls from several Repair Centers. Coordination of these services is provided through the nearest Sales Office or Customer Service Center. The Center is also prepared to help you with the following: Technical Assistance Troubleshooting Repairs Loaner Units Spare Parts Installation Materials System Accessories 8.1 In Case of Trouble Symptom Pump Not Running Low Pressure Alarm High Pressure Alarm High Humidity Alarm Unit Will Not Power Up The first step you should take if trouble develops using a dehydrator is to read the operators manual and follow the trouble shooting procedures given in it. HR150 SERIES DEHYDRATOR USER GUIDE MANUAL Potential Solution Cycle power of the unit Verify pumps are connected to PCB Open output port and verify pump speed increases Unused output port not capped Transmission line open/leaking Internal tubing disconnected / leaking Very small system volume; allow unit pressure to settle over 20 minutes Leaking desiccant canister end plate Insufficient system purge DC Power polarity may be reversed Loose or disconnected wire inside of the unit If the steps in the manual do not identify and remedy the problem, then contact a CommScope Customer Service Center for 24 hour telephone assistance. Record the Model Number (e.g. HR150) and Serial Number from the product label, as you will be asked for these when you call. Two main locations are currently available to help: From North America Telephone: 1 800 255 1479 Fax (U.S.A.): 1 800 349 5444 International Telephone: +1 779 435 6500 Fax Number: +1 779 435 8579 Web Access Internet: www.commscope.com email: #prc@commscope.com 8.2 Initial Steps by CommScope When your call or fax communication is received, the CommScope staff will work with you to pinpoint the possible cause of trouble. If the pressurization equipment is suspect, they will: ask for your unit Model Number and Serial Number check the warranty status of the unit advise the availability of a loaner unit provide an estimate of the cost for inspection and repairs, if the unit is out of warranty fax a Return Material Authorization Sheet to you 8.3 Repair Center Process A method of Payment must be provided prior to issuing of RMA regardless of warranty status. IN WARRANTY REPAIR: This CommScope pressurization product carries a warranty of one year. Warranty details are available on our web page. If your unit falls within its warranty period, inspection and repairs will be performed at no charge and the unit will be promptly returned to you. If a warranty unit is deemed no problem found an inspection fee and freight will be charged to the customer. OUT OF WARRANTY REPAIR: We will inform you with the cost of repair and obtain your approval to proceed with repairs or, if you elect not to have the unit repaired, your instructions on disposition of your unit. When repairs are complete, we will return your unit and invoice you for the inspection charge, materials used for the repair and labor applied to complete the repair. If you elected not to repair the unit, we Page 11 of 12

HR150 SERIES DEHYDRATOR USER MANUAL 8.4 will invoice you for the inspection and freight charge if unit is to be returned. LOANER UNITS: Loaner units may be available from the repair center to maintainn your system while repairs are being performed. If you feel you need a loaner, please contact us at one of the contact numbers. If a loaner unit is available, a P.O. for the full value of the unit must be issued priorr to shipment. Also contact us when the loaner is i ready to be returned so that we can issue a NEW RMA number to identify your return and create the appropriate credit to your account. Damages to loaner will be deducted from the P.O. PACKING INSTRUCTIONS: Pack your unit securely for shipment to the Repair Center. If you received a loaner unit, we suggest you use the box and packing materials to return your unit. Otherwise we have factory packing materials available for a nominal fee. Enclose a completed copy of this form inside the box and clearly mark your Company Name and RMA: XXXXXXX on outside of the box. Address the box to the following Ship To Address: CommScope Pressurization Servicee Center RMA# XXXXXXX 11312 S. PIPELINE RD. EULESS, TX. 76040 6629 Pleasee note, Units received with Biological/animal contamination will be returned unrepaired or scrapped after notification and you will be invoiced for inspection and freight. CONTACT NUMBERS: If you have any questions about the repair process or status of your unit, pleasee contact us directly through one of the following methods Telephone (below) TEL: 817 864 4150 817 864 4155 FAX: 817 864 4179 RoHS Inquiries For inquiries on RoHS please contact the following: CommScope Inc. Corke Abbey, Bray Co., Dublin, Ireland Attn: Legal Department Page 12 of 12