Chargebuster Overhead Ionizer Installation, Operation and Maintenance

Similar documents
Bench Top Ionizer Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance

CRITICAL ENVIRONMENT (C/E) SERIES OVERHEAD IONIZER OWNER S MANUAL

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

Critical Environment Ionizing Blower. Model 5810i. User s Manual

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

3M Overhead Ionizing Blower 991A

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

IONIZING AIR BLOWER INSTRUCTION MANUAL

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

OPERATION INSTRUCTION

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

3 963/963E Benchtop Air Ionizer Instructions

3M Benchtop Air Ionizer 963E. User s Guide

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL

ELIMINOSTAT DC-ESR-CL-S2

Veritas Appliance Hardware Service Procedure

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors

INTERNATIONAL STANDARD

ESD BASICS. Basic Concepts in ElectroStatic Discharge (ESD) Copyright 2005 DESCO INDUSTRIES INC. 9/05

Soldering Station INSTRUCTION MANUAL

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Electrostatic Discharge Control in the Manufacture of Telecommunications Equipment

STATIC ELECTRICITY SOLUTION APPLICATION SHEET

RLD-H10G Refrigerant Leak Detectors

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

CHARGED PLATE DETECTORS

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

RLD-H10P Refrigerant Leak Detector

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

Carbon Monoxide Transmitter

FLT93 Installation, Operation and Troubleshooting Guide

Safety and Installation Instructions Model 1700

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

EC Series Wall Unit Humidifier

Operating Instructions

Installation Instructions for W2H Series Signals

P4200PM / P5000PM Remote Air Dryer User s Guide

RE-PR3-E-27 3-Phase Panel Mount 27kW

อ เมลล :

Installation and Maintenance Manual IM 1102

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Document No

ZJ-FA10. Advanced Ionizer with Visible Discharge Status. Ionizer (Advanced Fan Type) Features. Sensing Charge and Discharge Status

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

P6500W Air Dryer User s Guide

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

RK Carbon Monoxide Transmitter Operator s Manual

CAUTION & SYMBOL DEFINITIONS:

SPLIT - TYPE ROOM AIR CONDITIONER

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

XPS-ProDry User s Guide Dryer Base

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Electrostatic Discharge. ESD Basics and Protection

Analog Room Pressure Monitor RPC Series

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

Schneider Electric Erie T155 Series

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Public Safety DAS Annunciator Panel

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

RangerNET Network Ready Constant Monitor Model CM2815

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

DC200 Digital Dispenser Operating Manual

Mark 25 Ultrapure Water Conductivity Analyzer

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

OG5000 Ozone Generator Model OG5000B-A. User Manual

108A OTP1800. Grid Support. General Description

BioZone Scientific International contact information

H-10PM. Refrigerant Leak Detector

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

Intensity Level. Intensity Control. Signal Type Switch. 12V Power Port. Signal Ports

Door Release Power Supply

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Model 4001 Series Single Channel Controller

Hand Dryer Installation & User Manual

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

40KMC KMQ

Controllers. Instruction Manual WARNING

Instruction Manual WARNING

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

INSTALLATION, OPERATION AND SERVICE MANUAL MIGHTY ION MODEL MI SERIES

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Transcription:

TECHNICAL BULLETIN TB-6545 Chargebuster Overhead Ionizer Installation, Operation and Maintenance Figure 1. EMIT 50682 Chargebuster Overhead Ionizer Figure 2. EMIT 50681 Chargebuster Overhead Ionizer Made in the United States of America Description EMIT Chargebuster Overhead Ionizers are steady-state DC ionizers designed for use in ESD protected areas. The 2-fan ionizers (50682, 50602) have a 2' x 4' coverage area, and the 3-fan ionizers (50681, 50603) have a 2' x 5' coverage area. The Chargebuster Overhead Ionizers discharge times (< 3 seconds at 18") and low offset voltage (±10 volts) meet the required limits of ANSI/ESD S20.20 < ±35 volts tested per ANSI/ESD STM3.1 and ESD TR53. Its emitters are made of pure tungsten and spaced further apart to minimize ion recombination, increase discharge efficiency and provide a broader coverage area. The fans have 3 speeds (high, medium, low) which produce consistent performance at all 3 settings. The Chargebuster Overhead Ionizers utilize an auto-feedback system that continuously optimizes its performance and automatically alarms and shuts down should its supply voltage drop. The EMIT 50602 and 50603 Chargebuster Overhead Ionizers include 700 lumen light panels (cool white) that provide additional illumination to the work area and improve visibility and productivity. The 50602 features one light panel, and the 50603 features two. Figure 3. EMIT 50602 Chargebuster Overhead Ionizer with Light Figure 4. EMIT 50603 Chargebuster Overhead Ionizer with Lights Necessary non-conductors in the environment cannot lose their electrostatic charge by attachment to ground. Ionization systems provide neutralization of charges on these necessary non-conductive items (circuit board materials and some device packages are examples of necessary non-conductors). Assessment of the ESD hazard created by electrostatic charges on the necessary nonconductors in the work place is required to ensure that appropriate actions are implemented, commensurate with risk to ESDS [ESD sensitive] items. (ANSI/ESD S20.20 Foreword) In order to mitigate field-induced CDM [Charged Device Model] damage, the ESD program shall include a plan for the handling of process-required insulators. If the field exceeds 2,000 volts/inch, steps shall be taken to either: A) Separate the insulator from the ESD-sensitive device by a distance of 30 cm (12 inches); or B) Use ionization or other charge mitigating techniques to neutralize the charge. (ANSI/ESD S20.20 section 8.3) The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g., most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and footwear. TB-6545 Page 1 of 9 October 2017

Air ionization is not a replacement for grounding methods. It is one component of a complete static control program. Ionizers are used when it is not possible to properly ground everything and as backup to other static control methods. In clean rooms, air ionization may be one of the few methods of static control available. (ESD Handbook ESD TR20.20 Ionization, section 5.3.6.1) The Chargebuster Overhead Ionizer is available in four models: Item Fans Lights Input Voltage Power Cord 50682 2 0 220 VAC None 50681 3 0 220 VAC None 50602 2 1 220 VAC None 50603 3 2 220 VAC None Packaging 1 1 2 3 1 Chargebuster Overhead Ionizer Hanging Kit Emitter Point Cleaners (50682, 50602) Emitter Point Cleaners (50681, 50603) Certificate of Calibration Installation The Chargebuster Overhead Ionizer is designed to mount above the work area, providing even coverage without using valuable worksurface area. Mounting is a matter of personal preference. Use the included hanging kit to suspend the ionizer with its brackets, or secure its brackets to a shelf. Ensure that the mounting is secure and capable of supporting the weight of the ionizer. The power cord should be supported as well to protect the operator from any hazard. Figure 5. Fan Speed Switch, Power Input and Power Switch Operation 1. Set the fan speed switch to the LOW, MED, or HI position. Higher airflow will result in faster neutralization rates. 2. Position the ionizer so that maximum airflow is directed towards the items or area to be neutralized. 3. Turn the unit ON. When the unit is first turned on, it conducts a self-test. The audible alarm will sound and the LED will cycle through the colors red, yellow and green. The LED will remain green during normal operation. 4. Toggle the light switch on the front of the ionizer to ON to power the LED panel(s) (50602, 50603 only). The ideal mounting height is 18" above the worksurface, although the ionizer may be located slightly higher or lower if required. For optimum performance, ensure that the intake grills for the fans are not obstructed. Verify that the ON/OFF switch located at the back of the ionizer is in the OFF position. Plug the power cord into the ionizer, and plug the other end into a properly wired power outlet. Figure 6. Light Switch (50602 and 50603 models only) TB-6545 Page 2 of 9

Maintenance All ionization devices will require periodic maintenance for proper operation. Maintenance intervals for ionizers vary widely depending on the type of ionization equipment and use environment. Critical clean room uses will generally require more frequent attention. It is important to set-up a routine schedule for ionizer service. Routine service is typically required to meet quality audit requirements. (ESD Handbook TR20.20 section 5.3.6.7 Ionizer Maintenance / Cleaning) EIA-625, recommends checking ionizers every 6 months, but this may not be suitable for many programs particularly since an out-of-balance may exist for months before it is checked again. ANSI/ESD S20.20 section 6.1.3.1 Compliance Verification Plan Requirement states: Test equipment shall be selected to make measurements of appropriate properties of the technical requirements that are incorporated into the ESD program plan. CLEANING THE EMITTER POINTS Under normal conditions, the ionizer will attract dirt and dust (especially on the emitter points). To maintain optimum neutralization efficiency and operation, cleaning should be performed on a regular basis. In the event of circuit failure, the unit will enter shutdown mode. When the unit enters shutdown mode, ionization will be stopped, the LED on the front of the unit will illuminate a constant red, and the audible alarm will continuously sound. The user must then reset the unit by turning it OFF and back ON. With normal handling, the emitter points should not require replacement during the life of the unit. If necessary, item 50659 Replacement Emitter Points are available for purchase. Adjustments and Compliance Verification BALANCE OFFSET VOLTAGE ADJUSTMENT The Chargebuster Overhead Ionizer is an auto-balancing unit. However, tuning or manual adjustment can be accomplished by inserting a small screwdriver or trimmer adjustment tool into the balance adjustment hole. To increase the output in a positive direction, turn the potentiometer clockwise. To increase the output in a negative direction, turn the potentiometer counter-clockwise. INPUT VOLTAGE CONFIGURATION WARNING - Risk of electric shock These servicing instructions are for use by qualified personnel only. Do not perform any servicing of internal parts unless you are qualified to do so. NOTE: The AC power cord MUST always be disconnected before the unit is disassembled. The input voltage may be verified or reset by opening the ionizer s enclosure. This can be accomplished by removing the 10 screws that secure the cover to the base. The ionizer s input voltage can be configured to 120 VAC or 220 VAC using the JH1 jumpers located on its PCB. See Figures 7 and 8 for these configurations. The emitter points should be cleaned using the included Emitter Point Cleaners or a swab dampened with Isopropyl alcohol. 1. Turn the unit OFF and unplug the power cord. 2. Open the top screen by loosening the screw and swinging the grill to one side. 3. Clean the emitter points using the included Emitter Point Cleaners or a swab dampened with Isopropyl alcohol. Figure 7. 120 VAC jumper setting Figure 8. 220 VAC jumper setting If the supply voltage drops from 110 Volts to below 85 Volts or from 200 Volts to below 170 Volts, the unit will shut down, the audible alarm will beep and the LED will blink red. The unit will automatically reset when the minimum voltage is restored. 4. Reattach the top screen. 5. Plug in the power cord and turn the unit ON. 6. Verify the performance of the ionizer by using a charged plate monitor, or ionization test kit. TB-6545 Page 3 of 9

Calibration When an alarm sounds, most users will clean emitter pins (see Maintenance / Alarms section) and calibrate the ionizer. Per ESD TR53 section 5.3.6.7.1 The best practice is to measure the offset voltage and discharge times, clean the unit, including emitter points and air filters if present, offset voltage to zero (if adjustable), and then repeat offset voltage and discharge time testing. If the unit does not meet offset voltage specifications or minimum established discharge time limits, further service is indicated. Manufacturers should provide details on service procedures and typical service intervals. Most companies will assign a number or otherwise identify each ionizer and setup a Compliance Verification / Maintenance / Calibration schedule. If the ionizers all test good, the data can justify lengthening the calibration period. If ionizers require adjustment the calibration period should be shortened. Although ESD TR53 does not advise a test frequency, JESDD625-A (Revision of EIA-625) recommends ionizers be tested semiannually, noting to use S3.1 except the number of measurement points and locations may be selected based on the application. NOTE: A charged plate analyzer or monitor should be used in order to properly calibrate the Chargebuster Overhead Ionizer (see the EMIT 50571 Analyzer). 1. Properly setup the ionizer as described in the Installation procedure on page 1. 4. Push and hold the ALARM RESET button on the ionizer until the STATUS LED turns red. Release the button and the LED should switch back to green. This allows the user to calibrate the balance (offset voltage) of the ionizer without setting off the alarm. 5. The balance (offset voltage) of each fan should be within 0 and ±10 volts. The required limit per ANSI/ ESD S20.20 is less than ± 35 volts. To increase the output in a positive direction, turn the BALANCE ADJUST potentiometer in a clockwise direction. To increase the output in a negative direction, turn the BALANCE ADJUST potentiometer in a counter-clockwise direction. 6. Test the neutralization (discharge) times by applying ±1,000 volts on the charged plate. The neutralization (discharge) time typically will be less than 3 seconds when charged plate analyzer is directly under a fan. See the Neutralization (Discharge) Times section for typical discharge times. The required limit per ANSI/ESD S20.20 is user defined. 7. Submit the balance (offset voltage) to the ionizer s control circuit by quickly pressing the ALARM RESET button. The STATUS LED should turn off and then illuminate green to verify that the control circuit was successfully programmed. 8. Test each fan s alarm by shorting its two grills located on the bottom side of the ionizer. The alarm should sound and the STATUS LED should illuminate red. 2. Turn the unit ON and set the FAN SPEED to HIGH. 3. Position the charged plate analyzer 18 inches underneath one of the fans of the ionizer. Figure 9. Calibration controls Figure 10. Shorting the ionizer s two fan grills TB-6545 Page 4 of 9

Neutralization (Discharge) Times All data was taken with the fan speed set to high. All time measurements are in seconds. The distance between the overhead ionizer and charged plate is 18" per ANSI/ESD STM 3.1. NOTE: Discharge times in seconds are representative only and are not a guarantee. Discharge times are actual measurements recorded in a factory ambient environment. Per ANSI/ESD S20.20, the test method for Product Qualification test is ANSI/ESD STM3.1, and for Compliance Verification is ESD TR53 which advises Measurements should be made at the location where ESD sensitive items are to be ionized. A larger area may require additional ionizers. Per S20.20 the required limit for ionizer discharge time is user defined. Use Table to determine the number of ionizers to achieve ionization of area to be neutralized to meet your company s ESD control plan specified discharge times. 16" 10.4(+) 3.4(+) 3.3(+) 9.1(+) 11.8(-) 3.7(-) 3.6(-) 9.7(-) 4.1(+) 2.0(+) 2.2(+) 3.4(+) 4.8(-) 2.3(-) 2.7(-) 3.9(-) 1 2 7.5(+) 2.6(+) 3.0(+) 7.0(+) 8.4(-) 3.2(-) 3.9(-) 9.1(-) Figure 11. 50681, 50603 Neutralization (Discharge) Times at 100VAC, 50Hz input TB-6545 Page 5 of 9

16" 8.2(+) 9.5(-) 2.2(+) 2.9(-) 2.2(+) 5.5(+) 6.7(-) 2.5(+) 3.4(-) 1.4(+) 1.9(-) 1.9(+) 2.3(-) 2.3(+) 1 2 5.2(+) 6.8(-) 2.1(+) 2.4(+) 5.8(+) 7.6(-) Figure 12. 50681, 50603 Neutralization (Discharge) Times at 120VAC, 60Hz input 16" 10.1(+) 10.8(-) 3.2(+) 3.4(-) 2.7(+) 3.0(-) 7.5(+) 8.4(-) 3.1(+) 3.2(-) 2.0(+) 2.1(-) 1.9(+) 2.0(-) 3.4(+) 4.2(-) 1 2 5.2(+) 5.4(-) 2.4(+) 2.6(-) 2.6(+) 3.0(-) 6.7(+) 7.5(-) Figure 13. 50681, 50603 Neutralization (Discharge) Times at 220VAC, 50Hz input TB-6545 Page 6 of 9

16" 9.9(+) 11.9(-) 2.7(+) 3.6(-) 3.3(+) 4.0(-) 15.6(+) 2 9.1(+) 11.8(-) 1.7(+) 2.1(-) 1.8(+) 2.2(-) 9.6(+) 1 1 2 13.5(+) 17.5(-) 3.9(+) 4.7(-) 3.8(+) 5.4(-) 14.8(+) 22.9(-) Figure 14. 50682, 50602 Neutralization (Discharge) Times at 100VAC, 50Hz input 16" 7.1(+) 9.3(-) 2.0(+) 2.5(+) 3.0(-) 10.3(+) 11.1(-) 6.1(+) 7.0(-) 1.4(+) 1.7(-) 1.9(+) 2.2(-) 8.5(+) 9.5(-) 1 2 9.8(+) 11.1(-) 3.0(+) 3.9(-) 3.7(+) 5.2(-) 10.7(+) 14.6(-) Figure 15. 50682, 50602 Neutralization (Discharge) Times at 120VAC, 60Hz input TB-6545 Page 7 of 9

16" 8.9(+) 11.8(-) 3.2(+) 3.5(-) 2.2(+) 3.2(-) 12.3(+) 14.9(-) 8.1(+) 9.2(-) 1.6(+) 2.1(-) 1.3(+) 1.8(-) 10.3(+) 14.4(-) 1 2 10.7(+) 11.3(-) 3.1(+) 3.6(-) 3.1(+) 4.3(-) 10.8(+) 1 Figure 16. 50682, 50602 Neutralization (Discharge) Times at 220VAC, 50Hz input TB-6545 Page 8 of 9

Specifications Typical positive and negative discharge times (1000V to 100V) measured using ANSI/ESD STM 3.1 are shown in the Neutralization (Discharge) Times section. The performance of the ionizer was measured with the unit positioned as shown, with the fan speed on high and without a filter. Air Flow 50681, 50603 - Three speed fan (150 cfm - 300 cfm) 50682, 50602 - Three speed fan (100 cfm - 200 cfm) Balance (offset voltage) ±10 Volts Typical ±20 Volts Maximum (Temperature Range: 65 F - 80 F, RH: 15% - 65%) Chassis Powder coated steel Health There are no known health risks associated with our devices. The emitters work at about 4-6 kv and can create ozone, but there have been no significant measurement of ozone from our emitter sets, as all our existing units test well below the OSHA limit of 0.05 ppm ozone. For additional safety information, see Dispelling an Old Myth written by William Metz of Hewlett-Packard published in Evaluation Engineering Magazine, September 2001. Limited Warranty, Warranty Exclusions, Limit of Liability and RMA Request Instructions See the EMIT Warranty - http://emit.descoindustries.com/warranty.aspx Dimensions 50681, 50603-3.9" H x 6.6" W x 37.3" L (9.9cm H x 16.8cm W x 94.7 cm L) 50682, 50602-3.9" H x 6.6" W x 22.3" L (9.9cm H x 16.8cm W x 56.6 cm L) Emitter Points.050" diameter Made of pure tungsten for improved mechanical strength and ionization stability. Fuse 400mA slow blow High Voltage Power Supply 5.5kV DC nominal Input Power AC line power Internally selectable for 100/120 VAC - 50/60Hz or 220/230 VAC - 50/60Hz Ion Emission Steady-state DC with sense feedback Lights (50602, 50603 only) 700 lumen each Cool white color 12 year estimated life expectancy (based on an average use of 10 hours per day) Mounting May be rigid-mounted or suspended from ceiling Ozone < 0.05 ppm Weight 50681, 50603-10 lbs (4.5 kg) 50682, 50602-7 lbs (3.2 kg) TB-6545 Page 9 of 9