Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar Chimney

Similar documents
GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

Evaporative cooling process adaptive for Baghdad city climate

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

AR/IA 241 LN 231 Lecture 6: Passive Cooling

Chapter 10. Passive Cooling Contents

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Drying of agricultural products using forced convection indirect solar dryer

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Solar Drying Techniques And Performance Analysis: A Review

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Open Cooling Tower. Equipment Layout Guide

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Influence of the magnitude of the angle of attack on the voltage produced by a miniature wind turbine

Performance analysis of solar water heater in NEH region of India

2. HEAT EXCHANGERS MESA

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Indoor Air of a Double-Storey Residential House in Malaysia

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

HME09 NATURAL VENTILATION

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

EqUIPMENT LAYOUT MANUAL

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

POSSIBILITY TO USE SOLAR INDUCED VENTILATION STRATEGIES IN TROPICAL CONDITIONS BY COMPUTATIONAL FLUID DYNAMIC SIMULATION

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

EVALUATION OF THE THERMAL PERFORMANCE OF METAL ROOFING UNDER TROPICAL CLIMATIC CONDITIONS

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

USE OF DOE-2 TO EVALUATE EVAPORATIVE COOLING IN TEXAS CORRECTIONAL FACILITIES

Performance Optimization of the Evaporative Condenser Design

COOL BUILT FORMS The Design/Planning Dilemma of Courtyards

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

How to improve air cooler vacuum steam condensers performance in the field

HUMIDITY RELATIONSHIP DETERMINATED IN THE DRYING CEREAL SEED FLUIDIZED BED

Falling Film Heat Exchangers for Solar Water Heaters

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

How Much Energy is Really Being Wasted?

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Thermal Properties and Temperature

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Heat transfer and heating rate of food stuffs in commercial shop ovens

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Effect of Inclination Angle on Temperature Characteristics of Water in- Glass Evacuated Tubes

Design and Development of Combined Direct and Indirect Evaporative Cooling System

Compression of Fins pipe and simple Heat pipe Using CFD

Passive Indirect Evaporative Cooler

A Novel Approach for the Thermal Management. of PC Power Supply

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

To investigate the surface properties for increasing efficiency of solar water heater

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Modified Air Cooler with Split Cooling Unit

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

The effects of green spaces (Palme trees) on the microclimate in arides zones, case study: Ghardaia, Algeria

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

K.F. Fong *, C.K. Lee, T.T. Chow

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

HVAC (Heating, Ventilating, and Air Conditioning)

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

Purdue e-pubs. Purdue University

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Scholars Research Library

The following report is prepared and published by:

Transcription:

PLEA2005 - The 22 nd Conference on Passive and Low Energy Architecture. Beirut, Lebanon, 13-16 November 2005 1/6 Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar Chimney Judhajit Chakraborty and Ernesto Fonseca College of Architecture and Environmental Design, Arizona State University, Tempe, Arizona, USA ABSTRACT: Passive Evaporative Cooling is one of the most efficient and long recognized ways of inducing thermal comfort in predominantly hot and arid climates. In order to extend the use of evaporative cooling, a downdraft evaporative 'cool tower' was integrated at the Solar Lab at the School of Architecture and Landscape Architecture, Arizona State University. The model explains how elevated temperature and pressure differences can increase the efficiency of a cooling tower, and how adding a Solar Chimney can create that elevated pressure difference. The synergy created by the cooler incoming air through the cool tower (positive pressure) and the hot air exiting through the solar chimney (negative pressure) will definitely alter the air movement and therefore the fluid dynamics. Our objective is to analyze the indoor air velocity increment and the indoor air movement, as well as the possible heat gains through convection and conduction due to increased air circulation. To accomplish our research, a scaled model has been built at the Solar Laboratory of the College of Architecture and Environmental Design where we will be executing, monitoring and collecting data for a period from 25 th April to 5 th June, 2005. The time for data under consideration for the paper is 24 hours from AM, 31 st May to AM, 1 st June. Conference Topic: 4 Innovative Low Energy Technologies. Keywords: Down-draft cool tower, Passive Evaporative Cooling, Buoyancy Ventilation, Thermal comfort INTRODUCTION A Cool Tower is one of the most efficient ways of inducing passive evaporative cooling in buildings located in predominantly hot and arid climates. It does not require any blowers or fans to move the cool air. The only power required is for a small DC pump to circulate water over the cooler pads or a mister. A cool tower is a perfect answer for cooling a Renewable Energy powered dwelling. Cool towers use gravity to move cool air without any fans, although fans might be used in order to reduce the size of the towers. The most common cool towers do this by having a wet pad medium in the top of the tower. Since cool air is heavier than warm air, it moves down, creating its own airflow. Wind is not required, but will improve the airflow in a cool tower. Passive ventilation systems rely on the movement of air through buildings to equalize pressure. The pressure difference can be caused by Wind or the Buoyancy effect created by stratified warm air. In either case, the amount of ventilation will depend critically on the size and placement of openings in the building. The maximum the pressure difference, the greater will be the efficiency of a Cool Tower. 2. TWO RELATED TERMS 2.1 Buoyancy Ventilation Buoyancy ventilation, which is more commonly known as temperature-induced or stack ventilation, results from differences in air density. The density of air depends on temperature and humidity. Cool air is heavier than warm air at the same humidity. Thus, the dropping of heavier air, forcing lighter air to exhaust, generates airflow. Tower height, or the distance from the air intake (top of tower) to the air outlet (bottom of tower), will determine the velocity or pressure of the air. The greater this distance the more air pressure created, similar to a water column. The tower uses a column of cool moist air (compared to the hot dry air outside) to create this pressure. Wind causes a positive pressure on the windward side and a negative pressure on the leeward side of buildings. To equalize pressure, fresh air will enter any windward opening and be exhausted from any leeward opening. Cooler pads or misters sit at the top of a tower with pump re-circulating water over them. As hot air passes through the pads or misters it is cooled by the evaporation of the water. Cool moist air is heavier than hot dry air and drops down the tower and into your house. In order for the cool air to flow in, hot air must be exhausted. 2.2 Solar Chimney A solar chimney is another ingredient for providing naturally drafted ventilation and thermal comfort inside living spaces. It generates air movement by buoyancy forces, in which hot air rises and exits from the top of the chimney, drawing air through the building core in a continuous cycle. The driving force on the air column in the chimney is the difference in the density of the air inside and outside the chimney. If the height of the chimney is such that the normal variation of pressure and temperature in the atmosphere can be neglected, together with temperature changes within the Chimney due to

PLEA2005 - The 22 nd Conference on Passive and Low Energy Architecture. Beirut, Lebanon, 13-16 November 2005 2/6 adiabatic expansion, the pressure difference P can be given by: P = 11.67 (1- T a / T c) h Where h is height of chimney, T a is ambient air temperature and T c is temperature inside the chimney. Neglecting losses in the chimney (a reasonable assumption for a chimney of diameter greater than 1/10 of its height), the air velocity at the top of the chimney can be given by: V= (2 P 1) Where 1 is the density of air at chimney temperature. Thus, the effort in this experiment will be prove that a combination of both these strategies which work on the same principle can bring about a much higher degree of comfort which will be directly proportional to the outside dry bulb temperature. Alternatively, the building can be aerodynamically shaped to encourage an increased velocity air stream over the building. This improves the draw and therefore the performance of the wind tower. 3. THE EXPERIMENT 3.1 Set up The experimental evaluation for evaluating the efficiency of a Down Draft Evaporative Cool Tower (DECT) was performed at the Solar lab at the School of Architecture & Landscape Architecture, ASU, from the 25 th April to the 5 th June 2005. The experiment required setting up a scaled model of a cool tower having tower dimensions of 25 X 30 X 244 (l X b X h) Cu.Cms. The tower is made of single ply board. The tower is attached to a box made up of Styrofoam as seen in Fig 5 & Fig 6. An opening is made at the plane of attachment to provide the cool air inlet. There is also another opening in the northern side, which is provided with a single glass cover as shown in Fig 6. A solar chimney of diameter 10cms and height of 1mt. is then attached and is colored pitch black in order to increase the negative pressure to scoop out the hot air from inside the box. The sizes we came up with for the cool tower and the chimney at this scale were too small to be calculated in the COOL T program which is a simple DOS tool developed by N.V. Chalfoun, at the University of Arizona, Tucson for calculating sizes of cool towers and their corresponding air velocities. So, the sizes of the tower and the chimney we came up with were actually averaged out from the Thomson & Cunnigham cool tower dimensions built in Tucson, Arizona. Thermocouples were then attached to each surface as tabled in Fig 1 to take down the temperatures. A total of 15 thermocouples are then attached in the order shown in the table above. All the thermocouples are then connected to an AGILENT BENCHLINK data logger which collects all the temperatures at an interval of 10 seconds. Two MRT (Fig 1 & 3 below) Fig 1. Position of the 15 thermocouples attached to the various Cool Tower components. balls are kept inside the box to collect mean radiant temperatures. One is placed near the cool air inlet of the box and the other one is placed near the solar chimney opening to ascertain exit air temperature and also of the surroundings. The wind tower is provided with a conical scoop at the top. The scoop is provided with a mister (Fig 8) to provide with a supply of water to cool off the air comes down from the scoop, and thus it becomes heavier and moves down the tower and inside the box through the opening for the cool air inlet. Water to the mister is pumped from a pump and a valve from lower level as shown below in Fig 9. Fig 2. A comparative study and chart of different scoop design done by Prof. Yair Etzion et al. for cool tower performance enhancement. 3.2 Design of the scoop for air intake The utilization of wind capture has been investigated as a potential improvement to the above said configuration, which helps in: (i) Saving on the need for a mechanical fan, and thereby increasing potential energy savings accordingly, and (ii) Enlarging the potential for overall airflow, and in turn the cooling capability of the tower. Since the supply of wind energy is not constant throughout the

PLEA2005 - The 22 nd Conference on Passive and Low Energy Architecture. Beirut, Lebanon, 13-16 November 2005 3/6 desired hours of operation, an optimal configuration should be sought which would exploit positive wind pressure when available and minimize resistance to airflow when the tower is fan-assisted. After a thorough research done for appropriate designs for wind scoop, the research done by Prof. Yair Etzion et al. (Fig 2) was carefully studied and so, the conical scoop was chosen appropriate for the project. The variations of wind catcher designs done by Prof. Etzion et al. included louver-panel entrances of different sizes, and flat and curved deflectors inside the capture unit of both fixed and dynamic configuration as shown in the figure below. All configurations made use of the same symmetrical Figures 3 & 4: Conical scoop design for the cool superstructure, which admitted wind. The three initial designs (configurations 1-3, fig 2) employed inwardly swinging louvers of different sizes installed in each of the two openings, with the intention of reducing energy losses due to outflow on the leeward side of the wind catcher. Such flows appeared to be relatively weak, and the expenditure of kinetic energy on opening the louvers against the force of gravity apparently factored heavily in the low wind capture efficiency of these configurations, which failed to rise above 20% regardless of specific louver size or density (see graph in Fig.2). The resistance of these louvers also led to below average flows when forced air from a mechanical fan was used. Configurations 4 and 5 (Fig 2) employed fixed deflectors to channel wind flow into the tower. This approach led to an increased efficiency of over 25% in the case of flat deflectors, and nearly 35% in the case of curved deflectors. The latter also provided the least resistance to forced airflow, allowing an average velocity of 3.5 m/s. Two additional configurations (6 and 7, Fig 2) were also investigated by them, with swinging panels centred in the capture unit, both alone and in combination with a fixed deflector. While these yielded better results than the initial louvered openings, they did not surpass the performance of the curved fixed deflector, which was seen to provide the greatest overall wind capture. All these factors led us to come up with a conical scoop design for the experimental set up under consideration here, which can be seen in Fig 3 and Fig 4. Fig 5 (Top): The cool tower along with the solar chimney side elevation Fig 6 (left): Front/ north elevation. Fig 7 (Top Right): Placing the upper MRT ball in the enclosed space. Fig 8 (Bottom Right): View of the Tower from top showing the mister in action. Fig 9 (Bottom Left): Control Valve for the water supply to the misters.

PLEA2005 - The 22 nd Conference on Passive and Low Energy Architecture. Beirut, Lebanon, 13-16 November 2005 4/6 4. ANALYSIS OF EXPERIMENTAL DATA Looking at the theory, it can be assumed that the WBT depression (DBT - WBT); the ambient wind speed; the tower's height and cross section and the solar chimney can affect the performance of a passive evaporative cool tower to a large extent. The expected effects of the WBT depression, the ambient wind speed, and the solar chimney on the diurnal patterns of the flow rate through the cool tower are all in the same direction and thus enhance the airflow. There is a strong correlation between the diurnal patterns of the WBT depression, the wind speed, and the solar chimney temperature: all of them reach their maximum in the early afternoon and a minimum during the night. To distinguish between the separate effects of these correlated factors on the performance of the cool tower, the analysis of the individual effects was applied in sequence: starting with the factor considered to be the major one, and then observing the deviations of computed data from measured values as functions of the other factors. The data under analysis is for a 24 hour long period from AM on the 31 st May to AM, 1st June 2005. The first graph (Graph 1) shows efficiency of the misters that has been installed at the top of the cool tower just below the scoop. Though in that period the dry bulb temperature or the air temperature above the wind tower soared as high as 100.58 F at 5:17 pm and the average being 86.5 F, the average inlet air temperature remained as low as 67.8 F on an average. The inlet air temperature was 74.1 F at 5:17 pm when the highest temperature of the day was recorded. So, it can be said that the misters, though they need to be operated through out the entire length of the day, (night time temperatures after 9 pm are quite comfortable and so, water supply may be stopped at that time) proves to be effective in dropping down the temperature to a great extent. Now looking at the temperature recorded (Graph 2) by the MRT ball placed at a lower level at some distance to the air inlet, shows a little increase in temperature which is nothing but the cumulative effect of the internal heat gain as well as the cool air entry. The temperature record thus is a step ahead towards attaining the comfort level inside the box. It can be seen from the graph below that the MRT is also well below the air temperature outside, the average being 74.7 F in the peak hours that is between AM and pm, which is pretty much satisfactory. The maximum delta T however was actually on 5:17 pm when the outdoor temp. reached 100.5 F whereas the indoor temperature as taken from the Lower MRT ball was 77.7 F which is well within the comfort zone. Looking at this value, it can be said that the cool tower design is efficient to a greater extent. Now, looking at the temperature recorded by the upper MRT ball near the solar chimney, (Graph 3) it can be seen from the graph below that since the cool air becomes hot as it moves towards the chimney. It is mainly due to internal heat gains by the surface and also by the uninsulated glass surface on the other side of the set up. Thus the average temperature recorded by the upper MRT ball during the peak hours (AM PM) is 80.69 F. Now the mean of both the MRT readings will give the operative indoor temperature of the set up which is 77.7 F at the peak hours. And this temperature is well within the comfort zone. The next set of results as shown in Graph 4 shows comparison of the Dry Bulb Temperature to the temperature at the Inlet of the solar chimney and also to the temperature at the top of the solar chimney or the exit air temperature. The temperature readings seem to be satisfactory in the sense that air is being heated up by the chimney that creates a negative pressure through out the length of the chimney. This negative pressure then scoops out the air inside the set up thereby maintaining the air circulation cycle inside the experimental box. Thus looking at the data, it can be seen that the maximum temperature at the top of the chimney is 88.17 F where as at the bottom of the chimney at the inlet is 80.60 F. During daytime, this difference is higher than nights. This differential heat inside the chimney creates the negative pressure. In the next phase of the experimentation, evaluation of the pressure difference and wind flow will be ascertained. Finally, the last set of numbers make a graph (Graph 5) which shows the comparison between the pressure difference and wind velocity inside the chimney to the operative temperature inside. Although the maximum pressure difference took place at 9:47 pm and that was around 9.53 inches but the delta T was near 19 F the maximum being 19.72 F. The maximum air velocity inside the chimney was also recorded at the same time and the velocity was 11.50 mph. The graph thus succeeds in proving that not only elevated temperatures but higher pressure difference and wind velocities can increase the efficiency and performance of a passive evaporative cool tower. Future research in this experimentation will include an extensive research of water consumption and diurnal frequencies when the cool tower should be kept on along with the effects of the internal heat gains to the cooling process. CONCLUSION A simple model of a passive evaporative cool tower, as developed and tested in the Solar Lab of the School Of Architecture, Arizona State University has been described. Taking temperature readings through thermocouples attached at different parts of the set up did validation of the model. Based on the performance of the solar chimney and the ambient wind speed on the flow rate, demonstrated in the experimental study, the expected performance of an evaporative cool tower can be expressed as a function of the delta T, the pressure difference as well as the details of the tower and the main thermal properties of the building cooled by it. The model calculates the hourly values of the tower air entry temperatures, the chimney exit air temperatures, the temperatures of all the surfaces of the box, and two MRT balls for a day between the 31 st May and 1 st June 2005 and the results were satisfactory.

PLEA2005 - The 22 nd Conference on Passive and Low Energy Architecture. Beirut, Lebanon, 13-16 November 2005 5/6 12 10 8 Temp. 6 4 2 Time Graph 1 showing comparison of the external air temperature to the Inlet cool air 4- Dry Bulb Temp. (F) 5-Inlet cool air(f) 12 10 8 6 4 2 4- Dry Bulb Temp. (F) 9 Lower MRT (F) Graph 2 showing comparison of the external air temperature to the Lower MRT. 12 10 8 6 4 2 12 10 8 4- Dry Bulb Temp. (F) Operative Indoor Temperature. Graph 3 showing comparison of the external air temperature to the Operative Indoor temperature 6 4 2 4- Dry Bulb Temp. (F) 11 Inlet solar Chim (F) 15 Chimney up(f) Graph 4 showing comparison of the external air temperature to the temperature at the Inlet of the solar chimney and the temperature at the top of the solar chimney or the exit air temperature

PLEA2005 - The 22 nd Conference on Passive and Low Energy Architecture. Beirut, Lebanon, 13-16 November 2005 6/6 25.00 2 15.00 1 5.00 9:47 1 11:17 1 12:47 1 14:17 1 15:47 1 17:17 1 18:47 1 2 20:47 2 22:17 2 23:47 0:47 1:17 2:17 2:47 3:47 4:17 5:17 5:47 6:47 7:17 8:17 8:47 14.00 12.00 1 8.00 6.00 4.00 2.00 Graph 5 (below) showing comparison between the pressure difference, temp. difference and the air velocities at different times inside the cool tower Pressure difference ( P) Temperature Difference ( T) Air Vel. At the top of the chimney (V) in mph REFERENCES [1] B. Givoni, Semi-empirical model of a building with a passive evaporative cooling Tower, Sol. Energy, 50 (1993) 425-434. [2] Pearlmutter D., Etzion Y., Erell E., Meir I.A., Di H., "Refining the use of evaporation in an experimental down-draft cool tower", Energy and Buildings, Vol. 23, No. 3, pp. 191-197, 1996. [3] Kumar, Sanjay, Sinha, S; and Kumar,N. Experimental investigation of solar chimney assisted bio climatic architecture, Energy Conversion and Management, 39(Mar./Apr.): 441-444. 1998. [4] http://www.i4at.org/lib2/aircool.htm visited on June 2005. [5] http://www.battlemccarthy.com/research/windtowers visited on June 2005. Image Citation: [1] Figure 2: A comparative study and chart of different scoop design done by Prof. Yair Etzion et al. for cool tower performance enhancement cited from Pearlmutter D., Etzion Y., Erell E., Meir I.A., Di H., "Refining the use of evaporation in an experimental down-draft cool tower", Energy and Buildings, Vol. 23, No. 3, pp. 191-197, 1996.