Fault Current Monitoring in Electrical Installations

Similar documents
3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

AS/NZS 3190:2011 AS/NZS

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

Residual Current Devices

Arrangements, Local Systems and Singularities

INTERNATIONAL STANDARD

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

Bringing power to life. TECHNICAL BULLETIN RESIDUAL CURRENT DEVICE (RCD) SELECTION

INTERNATIONAL STANDARD

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

C 271/32 Official Journal of the European Union

Rules for Classification and Construction Additional Rules and Guidelines

SECTION AUTOMATIC TRANSFER SWITCHES

Operation and use. Functions and characteristics

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Electrical Engineering Textbook

INTERNATIONAL STANDARD

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ACMA mandated EMC standards

INTERNATIONAL STANDARD

Welcome to Hager Presentation

Requirements for Electrical Installations

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

GB/T / IEC 62423:2009

INTERNATIONAL STANDARD

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

TECHNICAL REPORT IEC TR General testing procedures for medical electrical equipment. Edition

AS/NZS IEC :2013

SECTION AUTOMATIC TRANSFER SWITCHES

Operating Manual RCM420

INTERNATIONAL STANDARD

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Australian/New Zealand Standard

INTERNATIONAL STANDARD

(Notices) EUROPEAN COMMISSION

SEL Arc-Flash Solutions

AS/NZS 3133:2008 AS/NZS

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Speed and Frequency Seite 1 von 7

Electrical Safety Ungrounded Power Supply Systems in Medical Sites

SEL Arc-Flash Solutions

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET

Independent, accredited testing station Member laboratory of STL and LOVAG

INTERNATIONAL STANDARD

Latch key safety limit switches Technical data

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Ackrediteringens omfattning / Scope of accreditation Components and installation

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Substations and high voltage installations exceeding 1 kv a.c.

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Note 1: TC 61 does not deal with appliances which are already explicitly covered by the scope of other IEC Technical Committees.

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 173/05)

Electrical Energy department

Requirements for Electrical Installations

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

INTERNATIONAL STANDARD

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 293/03)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Amendment Number 3 of BS how it might affect you

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Requirements for Electrical Installations

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

SANS :2012 Edition 1.8

SOUTH AFRICAN NATIONAL STANDARD

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Process Control Systems Engineering

INTERNATIONAL STANDARD

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS:

This is a preview - click here to buy the full publication

AS/NZS IEC :2015

Guide to: 17 th Edition Consumer Units

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. October 2014

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

NZECP 12:1993 ISSN COVER PAGE

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Audible warning devices for external alarm

Insulation fault evaluator EDS460-DG

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

DRAFT TANZANIA STANDARD

INTERNATIONAL STANDARD

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

AS/NZS IEC :2016

UFGS (August 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

VAMP 121. Arc protection unit. User manual

Transcription:

Fault Current Monitoring in Electrical Installations Foundations, Applications and Methods of Measuring Residual Current in AC and DC Systems - With Residual Current Monitors (RCMs) according to IEC 62020 and other International Standards Bearbeitet von Wolfgang Hofheinz Neuerscheinung 2004. Buch. 120 S. Hardcover ISBN 978 3 8007 2796 4 Format (B x L): 14,8 x 21 cm Gewicht: 257 g Weitere Fachgebiete > Technik > Energietechnik, Elektrotechnik > Elektrotechnik schnell und portofrei erhältlich bei Die Online-Fachbuchhandlung beck-shop.de ist spezialisiert auf Fachbücher, insbesondere Recht, Steuern und Wirtschaft. Im Sortiment finden Sie alle Medien (Bücher, Zeitschriften, CDs, ebooks, etc.) aller Verlage. Ergänzt wird das Programm durch Services wie Neuerscheinungsdienst oder Zusammenstellungen von Büchern zu Sonderpreisen. Der Shop führt mehr als 8 Millionen Produkte.

7 Residual Current Monitors (RCMs) 7.1 The distinction between residual current monitor (RCM) and insulation monitoring device (IMD) Residual current monitoring devices (RCMs), for the application in earthed systems and insulation monitoring devices (IMDs) for the application in IT systems, place importance on similar aspects: Indication instead of disconnection Early warning alarm before disconnection, pre-warning indication Trend recognition when insulation levels drop High availability of current supply Reduced fire level Fast fault location Recognition of faulty outgoing circuit A distinction between RCM and IMD is therefore required. In 1991 the International Electrotechnical Commission (IEC) passed a resolution in Pretoria, to establish a standard for insulation monitoring devices (IMDs). The application was based on a Norwegian document 23E (Norway)18. The task was allocated to Working Group 6 of sub-committee IEC SC 23E. Working Group 6 defined, for the first time ever, distinguishing characteristics between active insulation resistance monitoring and passive residual current monitoring. It was decided that IEC SC 23E shall establish a standard for passive monitoring devices, which was IMD C e R F R F Figure 7.1 Symmetrical insulation faults 67

based on the method of measurement for residual current measurement. Their work resulted in the international standard IEC 62020:1998-08, Electrical accessories Residual current monitors for household and similar uses (RCMs). Since then passive monitoring devices were referred to as RCMs. The note in the scope of IEC 62020 makes a distinction between RCM and IMD: The RCM is passive in its monitoring function and only responds to an unbalanced fault current in the installation being monitored. The IMD is active in its monitoring and measuring functions it can measure the balanced and unbalanced insulation resistance or impedance in the installation (see IEC 61557-8) (Figure 7.1). 7.2 Residual current monitor (RCM) according to IEC 62020:1998-08 IEC 62020 was published in August 1998, the first amendment to the standard in September 2003. The title of the standard is: Electrical accessories Residual current monitors for household and similar uses (RCMs). It formed the basis for the European standard DIN EN 62020. The following are extracts of the International Standard. They are referring only to the passages that are relevant for operators or constructors of electrical installations. The introduction refers to RCM: The purpose of a residual current monitor (hereinafter referred to as RCM) is to monitor an electrical installation or circuit for the presence of an unbalanced earth fault current and to indicate, by means of alarm, the presence of a residual current when it exceeds a predetermined level. An RCM may be used in conjunction with protective devices (see IEC 60364-4). Installation and application rules are given in IEC 60364. 7.2.1 Scope The scope of the standard in the original says: This International Standard applies to residual current monitors having rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A for household and similar purposes. These devices are intended to monitor the residual current of the installation and to give a warning if the residual current between a live part and an exposed conductive part or earth exceeds a predetermined level. RCMs detect residual alternating currents and residual pulsating direct currents whether suddenly applied or slowly rising. This standard applies to monitors performing simultaneously the functions of detection of the residual current, of comparison of the value of this current with the re- 68

sidual operating current of the device and of providing the prescribed warning signal(s) when the residual current exceeds this value. RCMs having internal batteries are not covered by this standard. The requirements of this standard apply for normal environmental conditions. Additional requirements may be necessary for RCMs used in locations having severe environmental conditions. This standard does not cover Insulation Monitoring Devices (IMDs) which are covered by the scope of IEC 61557-8. 7.2.2 Definitions (IEC 62020:1998-08) For the purpose of the standard the following definitions apply (also see chapter 2.3.1 of this book): 7.2.2.1 Pulsating direct current current pulsating wave form which assumes, in each period of the rated power frequency, the value 0 or a value not exceeding 0.006 A d.c. during one single interval of time, expressed in angular measure, of at least 150. [3.1.3] 7.2.2.2 Energizing quantity electrical excitation quantity which alone, or in combination with other such quantities, shall be applied to an RCM to enable it to accomplish its function under specified conditions. [3.2.1] 7.2.2.3 Energizing input-quantity energizing quantity by which the RCM is activated when it is applied under specified conditions. These conditions may involve, for example, the energizing of certain auxiliary elements. [3.2.2] 7.2.2.4 Residual operating current value of residual current which causes the RCM to operate under specified conditions. [3.2.4] 7.2.2.5 Residual non-operating current (I Δno ) value of residual current at which and below which the RCM does not operate under specified conditions. [3.2.5] 69

7.2.2.6 RCMs functionally independent of line voltage RCMs for which the functions of detection, evaluation and actuation do not depend on the line voltage. [3.3.2] 7.2.2.7 RCMs functionally dependent on line voltage RCMs for which the functions of detection, evaluation or actuation depend on the line voltage. NOTE It is understood that the line voltage is applied to RCMs for detection, evaluation or actuation. [3.3.3] 7.2.2.8 RCM type A RCM for which actuation is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. [3.3.8] 7.2.2.9 Operation alteration of the state of the RCM from the non-alarm state to the alarm state or vice versa. [3.7.1] 7.2.3 Classification RCMs are classified according to: Method of operation Type of installation Number of current paths Possibility of adjusting the residual current Possibility of adjusting the time-delay Protection against external influences Method of mounting Method of connection Type of fault indication Ability to directionally discriminate between residual currents on supply side and load side 7.2.4 Characteristics of RCM This chapter of the standard is rather extensive. For the purpose of this book, only the most important characteristics for the user are listed: Preferred value of rated voltage U n are 230 V and 400 V. Preferred value of rated current I n are 10 13 16 20 25 32 40 63 80 100 125 A. 70

Preferred value of rated residual current I Δn are 0.006 0.01 0.03 0.1 0.3 0.5 A. Standard value of residual non-operating current is 0.5 I Δn. Preferred value of rated frequency is 50 Hz and/or 60 Hz. Maximum actuating time equal to or greater than I Δn shall not exceed 10 s. RCM shall be protected against short-circuits by means of circuit-breakers or fuses complying with their relevant standards according to the installation rules of IEC 60364. 7.2.5 Marking and other product information The standard states that each RCM shall be marked in a durable manner with all or, for small apparatus, part of the following data: Manufacturer s name or trade mark Type designation, catalogue number or serial number Rated voltage(s) Rated frequency, if the RCM is designed for frequencies other than 50 Hz and/ or 60 Hz Rated current Rated residual operating current Settings of residual operating current in case of RCMs with multiple residual operating current settings Installation instructions, including identification of CT which may be used with the RCM Listed here are only the most important markings for the user. The standard itself has to be referenced for more detailed information. 7.2.6 Requirements for construction and operation In general it should not be possible to alter the operating characteristics of the RCM by means of external intervention. The RCM shall have the following features: The RCM shall be provided with a visual Power On indicator which shall be green. The RCM shall be provided with means for indicating a fault condition when the residual current exceeds the preset operating value, the primary indicating means being visual. RCMs shall be provided with a test device in order to allow a periodic testing of the ability of the RCM to operate. The test circuit shall be designed for continuous operation at 1.1 times the rated voltage. 71

For in-depth requirements on construction and operation the standard should be referenced. 7.2.7 Tests The clause on tests is the most extensive part of the standard, with very detailed requirements for type- and routine tests. The requirements won t be commented on at this point, as it can be assumed that an RCM in accordance with IEC 62020:1998 has successfully passed all tests described in the standard. 7.2.8 Conclusion IEC 62020 surely has contributed to making RCMs widely known. The standard itself is being incorporated in other standards dealing with installations. International revision of the standard is currently on the way. 7.3 Principles Residual current protective devices (RCDs) and residual current monitors (RCMs) are devices, based on residual currents (I Δ ) measurement system. The fundamental principle demands that all conductors of power supply and distribution systems to be protected, are led through a current transformer (CT), with the exception of protective conductors. The vectorial sum of all currents in a fault-free system therefore equals zero, so that no voltage is induced in the CT. However if a fault current yields via earth, a current originating in the secondary winding of a CT will initiate electromechanical tripping or rather disconnection of the respective part of the installation. Electro-mechanical residual current circuit-breakers (RCCB) function with a closed-circuit current relay, which is anchored with very low power on a magnet. If the relay coil is energized by the fault current, the anchor drops. Because the RCD doesn t require auxiliary power, in the fault scenario they have to off-set relatively strong contact forces with low energy. Residual-current release (DI) on the contrary are RCCBs functionally dependant on line voltage. The residual current detected by the CT is evaluated electronically. The electronics are also controlling a circuit element, for example a contactor or a circuit-breaker [7.1]. 7.4 New definitions In the course of a harmonization process the International Electrotechnical Commission, the IEC, established new definitions for residual current protective devices 72

(RCDs). Since 2001 the definition Residual Current Protective Device (RCD) has been incorporated in all new respective standards. The following are defining variations on the devices: Residual current protective device (RCD) An RCD is a mechanical switching device or an interconnection of devices, which task it is, to trigger the opening of contacts, when the residual current reaches a predetermined value under specified conditions (IEC 60755:1983-05, General requirements for residual current operated protective devices). NOTE Installations according to this International recommendation can be operated with or without auxiliary supply. Residual current circuit-breaker (RCCB) A mechanical switching device designed to make, carry and break currents under normal service conditions and to cause the opening of the contacts when the residual current attains a given value under specified conditions (IEC 61008:1996, Title see below). Table 7.1 lists the new definitions in accordance with their respective international standards. Abbreviation New definition Standard RCD Residual current protective device IEC 60755 PRCD Portable residual current protective device IEC 61540 SRCD Fixed socket-outlets residual current protective device IEC 61541 RCCB RCBO Residual current operated circuit breakers without integral overcurrent Residual current operated circuit breakers with integral overcurrent IEC 61008 IEC 61008 RCM Residual current monitors for household and similar uses IEC 62020 Table 7.1 Survey of new IEC definitions on residual current devices Residual current operated circuit breakers without integral overcurrent (RCCB) IEC 61008-1:2002-10, Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) Part 1: General rules IEC 61008-2-1:1990-12, Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs); Part 2-1: 73

Applicability of the general rules to RCCBs functionally independent of line voltage Residual current operated circuit breakers with integral overcurrent (RCBO) IEC 61009-1:2003-02, Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) Part 1: General rules IEC 61009-2-1:1991-09, Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) Part 2-1: Applicability of the general rules to RCBOs functionally independent of line voltage Portable residual current protective device (PRCD) IEC 61540:1999-03, Electrical accessories Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs) Reference [7.1] Hofheinz, W.; Sellner, H.: Schützen ohne Überreaktion. Elektrische Energietechnik (1995) H. 2 74