Rick Stanley. October 21, TFE 731 Technical

Similar documents
Aerospace W l e come t t o h the

Introduction. 1 The Global Customer Committee Charter

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Simsite. Impellers and Wear Rings. Improve Longevity & Performance with Simsite Products!

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

Type Acceptance Report

Custom Design TYPE CS

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

Avionics/Systems Policy Updates - Small Airplane Directorate

HONEYWELL, INC.

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

REVISION NO. 1 DATED SEPT 20/10 HIGHLIGHTS

Acquisition and Collection Development Section

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

FALCON 900EX EASy N988H S/N 125

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Innovation for a Better & Greener Future

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

Magnetic Refrigeration. Study Case

SECTION PLUMBING EQUIPMENT

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

Developments in the Americas Sector

Welcome to the Family Kit Eagle 407HP Commercial Helicopter & HTS900 Engine

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

ASME/ANSI Interpretations No. 6. Replies to Technical Inquiries July 1, 1987, Through April 30, 1988

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

TSEI Fall 2011 Meeting. Emergency Products Committee

LONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS

Chapter-8 Capacity Control of Refrigeration Systems

Belt Driven Mixed Flow Fans

ISO/TS TECHNICAL SPECIFICATION

A. Codes and Standards that are Standard at the University:

CASE STUDY ANALYSIS OF CENTRIFUGAL FAN HIGH AMPLITUDE VIBRATION. Ken Singleton

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

TURBO BLOWER. High Efficiency / Low Noise / Oil Free / 60,000rpm High Speed Motor(PMSM) ISO-9001 REGISTERED FIRM Det Norske Veritas B.V.

ECO-ANT21 Corporation

COMPONENT MAINTENANCE MANUAL

Multistage Centrifugal Blowers

Aerospace and Defense Applications

VERIFICATION OF FIRE ALARM SYSTEMS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Midea VFD Centrifugal Chiller Technology

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

This document is a preview generated by EVS

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

CAP SERIES SEWAGE AND WASTE WATER PUMPS

The Digital Scroll Dryer

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Design And Analysis Of Centrifugal Pump

INTRODUCTION: COOLING TOWER INTRODUCTION: COOLING TOWER FANS. The cooling Tower is commissioned since 2006 and 1 st failure was encountered in 2007

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Horizontal Split Case Pumps Type U

K4RH(X) Solids-Handling Pumps

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

3M Personal Safety Division. Standards Update. NFPA 1981/1982, 2018 Edition. March 30, 2018

CR A-F-A-E-HQQE 3x400/ HZ

Status Report of the SPE Oil and Gas Reserves Committee Where Is Our Focus?

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

CR A-F-A-E-HQQE 3x400/ HZ

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

equivaq Design Portfolio Last updated 3/1/2017

KEENER GRINDER PUMPS

INSTRUCTION AND REPAIR MANUAL

AIR CONDITIONING - DISTRIBUTION INSPECT, AND IF NECESSARY, REPLACE THE AIR CONDITIONING HOSES IN THE DE-FOG SYSTEM

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

Welcome to the Family

SPOC Before Change After Change Since today is publication/effective date, correction has actually been made to the manual and is viewable.

FILLING TECHNOLOGY FROM THE EXPERTS SAFE, CLEAN, POWERFUL

[Docket No. FAA ; Product Identifier 2017-NE-02-AD; Amendment ; AD ]

Turbo-blowers and Turbo-compressors

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

BULLETIN PIPER CONSIDERS COMPLIANCE MANDATORY. Piper Aircraft, Inc Piper Drive Vero Beach, FL, U.S.A Date: April 29, 2016 (S) (M)

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

SERVICE INSTRUCTION SI0035 Rev NC Page 1 of 3

This translation is for your convenience. It is not legally binding

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION COOLING TOWERS

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Wilo IL Vertical Split-Coupled Inline Pumps

Cent$ible Power Users Manual

ISO INTERNATIONAL STANDARD. Industrial fans Mechanical safety of fans Guarding

Failure Modes, Effects and Diagnostic Analysis

ANSI RAB QMS. Parag Energy Efficient Axial Flow FRP Fans

SECTION (15833) - HVAC POWER VENTILATORS

Flygt N-pumps 3231, 3306, 3312, 3356, 3400

Custom Projector Enclosure

Ashbridges Bay Erosion and Sediment Control Project

CAC OVERVIEW. CAC Roles and Responsibilities CAC Operations CAC Membership CAC DAC Relations

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Waters 2795 Separations Module

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

RAIN GUTTER, INTRODUCTION OF. HELICOPTERS AFFECTED: Serial numbers through

CFE738, HTF, HTS900, TFE731, TPE331

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

Transcription:

Rick Stanley October 21, 2014 TFE 731 Technical

HONEYWELL CONFIDENTIAL: This copyrighted work and all information are the property of Honeywell International, Inc., contain trade secrets and may not, in whole or in part, be used, duplicated, or disclosed for any purpose without prior written permission of Honeywell International, Inc. All Rights Reserved. EXPORT CLASSIFICATION: The enclosed technical data is export classified as 9E991. Its export is being transmitted under U.S. Export Administration Regulations designation NLR (No License Required) and is to be used solely by the individual / organization to whom it is addressed. Diversion contrary to U.S. export laws and regulations is prohibited. 2 This page subject to the restrictions noted in the introduction.

TFE731 Propulsion Systems Update 3 This page subject to the restrictions noted in the introduction.

Agenda TFE731 Propulsion Systems Update Global Customer Committee (GCC) TFE731 Fleet Statistics TFE731-60 Oil Line PN 3061253-4 Crack TFE731-20/40/50/60 Air Oil Cooler Supply Tube Chafing TFE731-20/40/50/60 Fan Bypass Stator Vane Repair TFE731-20/40 Fan Bypass Stator Vanes Redesign TFE731-20/40 Re-occurring Fan Vibration EEI Compatibility with Windows 7 4 This page subject to the restrictions noted in the introduction.

Global Customer Committee Highlights GCC Committee US 77 members worldwide 41 United States, 20 EMEAI, 16 APAC Operators, Pilots, Channel Partners Dan Frisone (440) 523-4809 Pilot Vice Chair Peter Zeeb 702.739.3742 Chairman Joe Bocsy 614-239-5443 Electrical Vice Chair Dan Wieprecht 214.353.2334 Mechanical Vice Chair Drastically improved our Management Operating System Top 25 Rolling Action Item List Balanced focus -mechanical/avionics/processes Closed 49 actions YTD 8 meetings/year (2 Face to Face/region, 2 Global Telecoms) Customer Teams work with Honeywell on top actions OEM Liaisons communicate directly with OEM Advisory Boards e-mail: GCC@Honeywell.com visit: http://committees.honeywell.com Committee Members 5 This page subject to the restrictions noted in the introduction.

TFE 731 Current Fleet Statistics TFE731-2/3/4/5 Engines in Service 9,202 Total Fleet Hours 79,742,021 12 month cumulative average 1,030,997 TFE731-20/40/50/60 Engines in service 3,340 Total Fleet Hours 12,206,103 12 Month cumulative average 966,599 As of August 2014 6 This page subject to the restrictions noted in the introduction.

TFE731-60 Oil Line PN 3061253-4 Crack Issue Oil lines found cracked at AGB supply tube Cracked oil tube can lead IFSD due to LOP Weld joint at the AGB supply branch tube to the large tube body cracked due to fatigue Action Re-design tube to improve robustness Status Redesigned to eliminate weld joints Incorporates IN625 casting Honeywell SB 79-5124 released Feb. 6th, 2013 Sister engine program available Commercially supported by Special Pricing Notice (SPN 36) Recommended for incorporation at MPI Current Design New Design 7 This page subject to the restrictions noted in the introduction.

TFE731-20/40/50/60 Air Oil Cooler Supply Tube Chafing Issue TFE731-20/40/50/60 Air Oil Cooler Oil Supply Tube Chafing Causing Oil Leaks Effected Part Numbers: 3060997-1 (-20/40); 3061934-1 (-50) & 3061042-4 (-60) Action Provide new tube design that solves the chafing issue on the TFE731-20/40/50/60 fleets Status New tube design certification complete Changing to a new 2-piece design to improve tube alignment SB released March 2014 - TFE731-79-5127 (TFE731-20/40/50/60 Civil Fleet) 8 This page subject to the restrictions noted in the introduction.

TFE731-20/40/50/60 Fan Bypass Stator Vane Repair Issue Leading edge screen on bypass stator vane can delaminate from vane Epoxy resin erosion can drive early vane replacement Action Develop vane epoxy resin repair (complete) Long term - Improve design - Foil leading edge vanes Screen Delamination Status Re-work service bulletin created to restore bypass stator vanes (TFE731-72-5232RWK released Feb 8, 2013) Bypass Stator Vane re-design program moving forward 9 This page subject to the restrictions noted in the introduction.

TFE731-20/-40 Bypass Stator Vane Re-Design Issue TFE731-20/40 bypass stator vane leading edge screen erodes and delaminates prematurely. Action A newly designed fan bypass stator vane with a foil leading edge that will increase vane life 4-6x. Screen Delamination Status Bypass Stator Vane re-design program moving forward Straight vane Foil leading edge Expected Q4 2014 certification Expected April 2015 Production Incorporation Expected Field release via SB July 2015 New design Prototype 10 This page subject to the restrictions noted in the introduction.

TFE731-20/-40 Re-occurring Fan Vibration Issue Operators report in-cabin noise leading to fan balance maintenance Action Observed on 25% of the TFE731-20 fleet (Learjet 40/45) Develop improvements to reduce the number of in-cabin noise and fan balance maintenance events Status Internal on-wing troubleshooting procedure developed May14, 2014 Will be undertaken on a case by case basis Being used on bad actors to collect further data Channel partners assisting Continue to closely work with operators that experience fan vibration issues Captured bad actor engine for further investigation in Phoenix Fan module analysis in support of root cause investigation Launched fan module investigation in August 2014 Update fan stack pilot analysis Root Cause Investigation Continuing in 2014 11 This page subject to the restrictions noted in the introduction.

EEI Compatibility With Windows 7 Issue Windows 7 is not FAA qualified as an operating system for Honeywell EEI software Action Test and qualify Windows 7 as a valid operating system for EEI and then release the software to the field Status Formal Qualification Testing Complete October 2013 FAA/DER sign off (all above documents) Complete March 2014 EEI Win 7(v 3) & FAQ document uploaded to My Aerospace portal Complete Issue SIL (Service Information Letter) Complete Windows 7 Compatibility Complete EEI Win 7 release article published in Business Aviation Newsletter 6/30/2014 http://aerospace.honeywell.com/news/available-now-win-7-e-engine-interface-software 12 This page subject to the restrictions noted in the introduction.

Questions?

Rick Stanley October 21, 2014 CFE738 Propulsion System Update 21-15417 Page 14 Use or disclosure of information contained on this page is subject to the restrictions on the cover. CFE COMPANY CONFIDENTIAL

Agenda CFE738 Propulsion System Update CFE738-1-1B Operational Experience No. 3 Bearing Cage Cracking Compressor Impeller Splitter Vane Airfoils Compressor Rotor Misconfiguration Revised Preservation & Storage Procedures Shrouds In Service Limits 15 This page subject to the restrictions noted in the introduction. CFE COMPANY Honeywell CONFIDENTIAL Proprietary

CFE738-1-1B Operational Experience 16 This page subject to the restrictions noted in the introduction. CFE COMPANY Honeywell CONFIDENTIAL Proprietary

No. 3 Bearing Cage Cracking Issue Unscheduled engine removals and sump entries following oil chip indication (front sump/agb) 4340 Steel Platelets liberated from cracks formed on low time No. 3 bearing ball separators (cages) Bearing inner race tilted on compressor shaft at install Action/Status Improved bearing installation procedures in Light (LMM) and Heavy (HMM) Maintenance Manuals Added new bearing drop checks and fixture, seating check fixture, through Temporary Revisions (TR) LMM TR 72-229 released November 6, 2013 HMM TR 72-173 released November 6, 2013 Service Information Letter D201303000061, Rev 1 Released December 17, 2013 Cracks Develop in Cage Web 17 This page subject to the restrictions noted in the introduction. CFE COMPANY Honeywell CONFIDENTIAL Proprietary

Compressor Impeller Splitter Vane Airfoils Issue Compressor surge events primarily in Max Cruise Borescope inspection findings of damaged compressor centrifugal impeller Manufacturing change in 2010 to vane thickness within tolerances Resulted in higher than expected stress Impeller splitter vane distress/missing material Action/Status Improved compressor impeller with thicker vanes Service Bulletin CFE738-72-8076 released October 31, 2013 Introduces new impeller PN 6079T77P09 Recurring, 400-hour limited borescope inspections Service Bulletin CFE738-72-8074 released November 7, 2013 Refer to Engine Logbooks to determine effectivity Service Information Letter D201304000128, Rev 1 Released December 17, 2013 Ensure Recurring Borescope Inspections are Performed 18 This page subject to the restrictions noted in the introduction. CFE COMPANY Honeywell CONFIDENTIAL Proprietary

Compressor Rotor Misconfiguration Issue Unintentional High Pressure Compressor (HPC) rotor configurations discovered in service Estimate up to sixty-nine (69) engines may be affected refer to engine logbooks Post-Service Bulletin CFE738-72-8057 Stage 2-3 Compressor Blisk used with pre-sb CFE738-72-8057 Tie Rod and Air Supply Tube Action/Status Configuration not approved for service SB CFE738-72-8057, Rev 3, released August 18, 2014 clarifies configuration SB CFE738-72-8077, Rev 0, released August 18, 2014 Replace Tie Rod and Air Transfer Tube at next CZI or access for cause 19 This page subject to the restrictions noted in the introduction. CFE COMPANY Honeywell CONFIDENTIAL Proprietary

New Preservation & Storage Procedures Issue Preservation instructions for installed engines too restrictive during major airframe inspections Engine motoring was required every 4 weeks to ensure oil wetted areas coated to prevent corrosion Key changes implemented CFE738 Light Maintenance Manual (72-06-03) Temporary Revision 72-232, released 06/18/14 Clarifications include return to service and corrective actions for procedure non-compliance Three (3) preservation Methods for uninstalled engines Two (2) Methods for installed engines Method 4 Changed motoring every 4 weeks to ground run after 60 days and then return to service Method 5 Up to 180 days hand-rotate spools every 30 days and start engine at end of period New Procedures Provide Increased Flexibility and Clarity 20 This page subject to the restrictions noted in the introduction. CFE COMPANY Honeywell CONFIDENTIAL Proprietary

Shrouds In Service Limits Issue: Falcon 2000 CFE738, most replaced LRU is fan inlet housing due to fan abradable material on the shroud missing. You can do knock test with screwdriver, be proactive with the inspection for fan inlet to prevent AOG. Could also be related to Domestic Object Damage (DOD). Actions & Status: Tap test inadequate to detect internal honeycomb disbond X-Ray & Ultrasonic Test inspections developed to detect Light Maintenance Manual (LMM) Temporary Revisions issued to reduce AOGs and rare DOD 03/24/2011: TR72-211, 72-212 and 72-213 released Added a 25-hour repair deferral; expanded missing material allowed (20 to 60 sq in); added Alodine treatment; added more readily available filler material (1.0 sq in areas, or less) 21 This page subject to the restrictions noted in the introduction.

Discussion