Development of capillary barriers during water infiltration in a geotextile-reinforced soil wall

Similar documents
Pullout of Geosynthetic Reinforcement with In-plane Drainage Capability. J.G. Zornberg 1 and Y. Kang 2

Performance of nonwoven geotextile-reinforced walls under wetting conditions: laboratory and field investigations

Evaluation of the Development of Capillary Barriers at the Interface between Fine-grained Soils and Nonwoven Geotextiles

HYDRAULIC CLASSIFICATION OF UNSATURATED GEOTEXTILES FOR USE IN CAPILLARY BARRIERS

Keywords: Unsaturated flow, infiltration, marginal fill, rainfall, nonwoven geotextile, sand cushion 1 INTRODUCTION

Combined functioning of geotextile as barrier and drainage material in unsaturated. earth retaining structures. Amalesh Jana 1 and Arindam Dey 2

Infiltration into unsaturated reinforced slopes with nonwoven geotextile drains sandwiched in sand layers

Capillary barrier dissipation by new wicking geotextile

Mechanical Behavior of Soil Geotextile Composites: Effect of Soil Type

EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL

LARGE-SCALE SHEAR TESTS ON INTERFACE SHEAR PERFORMANCE OF LANDFILL LINER SYSTEMS

Numerical Analysis of Leakage through Geomembrane Lining Systems for Dams

Assessment of Geotextile Reinforced Embankment on Soft Clay Soil

Experimental tests for geosynthetics anchorage trenches

Moisture Content Effect on Sliding Shear Test Parameters in Woven Geotextile Reinforced Pilani Soil

Field performance of retaining walls reinforced with woven and nonwoven geotextiles

TRANSMISSIVITY BEHAVIOR OF SHREDDED SCRAP TIRE DRAINAGE LAYER IN LANDFILL COVER SYSTEM *

GEOTEXTILE DEFORMATION ANALYSIS OF GEOSYNTHETIC CLAY LINERS WITH FEM

Keywords: slope stability, numerical analysis, rainfall, infiltration. Yu. Ando 1, Kentaro. Suda 2, Shinji. Konishi 3 and Hirokazu.

EAT 212 SOIL MECHANICS

Load-Carrying Capacity of Stone Column Encased with Geotextile. Anil Kumar Sahu 1 and Ishan Shankar 2

Backfill Stress and Strain Information within a Centrifuge Geosynthetic-Reinforced Slope Model under Working Stress and Large Soil Strain Conditions

EFFECT OF BOLT CONNECTION OF SQUARE-SHAPED GEOCELL MODEL ON PULLOUT TEST RESULTS

O M E Taha. Keywords: nanoparticles, shrinkage strain, expansive strain, nano-copper, nano-alumina ABSTRACT

Transmissivity of a Nonwoven Polypropylene Geotextile Under Suction

2.2 Soils 3 DIRECT SHEAR TEST

SUBGRADE IMPROVEMENT OF CLAYEY SOIL WITH THE USE OF GEOTEXTILES

Leakage through Liners under High Hydraulic Heads. PH (512) ; FAX (512) ;

Technical Supplement 14D. Geosynthetics in Stream Restoration. (210 VI NEH, August 2007)

Improvement of Granular Subgrade Soil by Using Geotextile and Jute Fiber

Full Scale Model Test of Soil Reinforcement on Soft Soil Deposition with Inclined Timber Pile

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

A new test procedure to measure the soil-water characteristic curves using a small-scale centrifuge

ABSTRACT. Work in this dissertation consists of three numerical studies undertaken to investigate the

Lessons Learned From the Failure of a GCL/Geomembrane Barrier on a Side Slope Landfill Cover

Comprehensive Material Characterizations for a Pavement Embankment Installed with Wicking Fabric

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

TECHNICAL REPORT STANDARD PAGE

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Geosynthetics: GEOTEXTILES ASDSO WOVEN GEOTEXTILE GEOSYNTHETICS IN DAMS. Geosynthetics in Dams, Forty Years of Experience by J.P.

Identification of key parameters on Soil Water Characteristic Curve

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Piles subject to excavation-induced soil movement in clay

Evaluating Tubular Drainage Geocomposites for use in Lined Landfill Leachate Collection Systems

[Gupta* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

COMPARISON OF SHEAR STRENGTH PARAMETERS OF BLACK COTTON SOIL WITH EFFECT OF RELATIVE COMPACTION

AASHTO M Subsurface Drainage

Behaviour of a Strip Footing on Compacted Pond Ash Reinforced with Coir Geotextiles

Performance of Geosynthetics in the Filtration of High Water Content Waste Material

Shear Strength of Soils

The University of Iowa Department of Civil & Environmental Engineering SOIL MECHANICS 53:030 Final Examination 2 Hours, 200 points

THE ULTIMATE SKIN RESISTANCE OF CONCRETE PILE IN PARTIALLY SATURATED COHESIVE SOIL BY MODIFIED Β METHOD

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Unsaturated Shear Strength Behavior under Unconsolidated Undrained Tests

A Method for Predicting the Matric Suction of Unsaturated Soils with Soil Color Recognition

Centrifuge modelling and dynamic testing of Municipal Solid Waste (MSW) landfills

CHAPTER 4 EXPERIMENTAL WORK 4.1 GENERAL

G E O T E X T I L E S

Reinforcement with Geosynthetics

Liner Construction & Testing Guidance Overview

Effect of characteristics of unsaturated soils on the stability of slopes subject to rainfall

A Drainage Geocomposite for Coal Combustion Residual Landfills and Surface Impoundments

Woven Polyester High. ACETex the proven choice for: n Embankment Support over piles. n Support over voids

Effect of Placement of Footing on Stability of Slope

Study on Effect of Water on Stability or Instability of the Earth Slopes

Overview of Geosynthetic Materials, Their Characteristics, Applications, and Design Considerations

A Study on Suction-rainfall Response of a Cut Slope in Unsaturated Residual Soil Using a Field Rain Simulator

PERFORMANCE OF GEOSYNTHETICS IN THE FILTRATION OF HIGH WATER CONTENT WASTE MATERIAL

The use of geosynthetics in the installation of ballast layers

SOIL STABILIZATION USING NATURAL FIBER COIR

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Desiccation of Fiber-Reinforced Highly Plastic Clays

Movement of soil water- Infiltration, percolation, permeability Drainage -

Geotextile Testing Equipment

Soil characteristics that influence nitrogen and water management

PULLOUT CAPACITY OF HORIZONTAL AND INCLINED PLATE ANCHORS IN CLAYEY SOILS

A METHODOLOGY FOR THEEVALUATION OF GEOTEXTILE POREOPENING SIZES UNDER CONFINING PRESSURE

Sea to Sky Geotechnique 2006

Assessments of Long-Term Drainage Performance of Geotextiles

Section Specification for Geotextile Used in Permanent Erosion Control Application

COHESIONLESS SOIL PROPERTIES IMPROVEMENT USING BENTONITE

Basic Geosynthetics: A Guide to Best Practices in Forest Engineering

LOAD TRANSFER MECHANISM IN PULL-OUT TESTS

INFLUENCE OF STRAIN RATE, SPECIMEN LENGTH AND CONFINEMENT ON MEASURED GEOTEXTILE PROPERTIES

Loading unsaturated soil. *Mohamed Abdellatif Ali Albarqawy 1)

GRI White Paper #8. - on - Construction Quality Assurance-Inspectors Certification Program (CQA-ICP)

Bearing Capacity Theory. Bearing Capacity

Global Journal of Engineering Science and Research Management

APPLICATIONS IN FILTRATION AND DRAINAGE & EROSION CONTROL

Geotextiles and Loess: Long-Term Flow

FINAL COVER VENEER STABILITY ANALYSES FOR SCA DESIGN

An Experimental Study on Variation of Shear Strength for Layered Soils

Merrill Zwanka Geotechnical Materials Engineer SCDOT Research and Materials Lab February Definitions Sampling and Testing Classification

Geosynthetic materials Solutions for improved ground structure. Name it. We ll do it.

Technical Specification Guidelines

Consolidation Stress Effect On Strength Of Lime Stabilized Soil

Settlement analysis of Shahid Kalantari highway embankment and assessment of the effect of geotextile reinforcement layer

Usage of Woven Geo-Textiles in the Construction Subgrade in Flexible Pavements

Modified geotextile tube a new geotextile tube for optimized retaining efficiency and dewatering rate

Transcription:

Development of capillary barriers during water infiltration in a geotextile-reinforced soil wall F. H. M. Portelinha Federal University of Sao Carlos, Sao Paulo, Brazil J. G. Zornberg The University of Texas at Austin, Texas, USA Portelinha, F.H.M., and Zornberg, J.G. (214). Development of Capillary Barriers during Infiltration in a Geotextilereinforced Soil Wall. Proceedings of the 1th International Conference on Geosynthetics, 1ICG, Berlin, Germany, 21-2 September 214 (CD-ROM). ABSTRACT: Nonwoven geotextiles have often been selected to provide internal drainage when reinforcing fine-grained soils. However, capillary effects have been typically neglected, although there are evidences that such barriers can develop in this system. In practical applications, backfill materials present low water contents and, consequently, negative pore water pressures (matric suction) often develop within the fill. This study includes an experimental investigation of the possible development of capillary barriers during infiltration in an unsaturated geotextile-reinforced soil model. A full-scale wall model was constructed in laboratory using a clayey sand soil. A wetting system was developed to simulate rainfall infiltration. The test setup allows simultaneous rainfall and loading. During infiltration, instrumentation was used to monitor water content and matric suction inside the reinforced fill. The testing program allowed observations of the capillary barrier development at interface soil-geotextile during infiltration process. In addition, the drainage function of reinforcements after the breakthrough was observed to occur when water pressure became negligible. Capillary barriers retarded the infiltration by 7 days per reinforced layer. Experimental profiles based on water contents measured inside the wall could be well defined and are represented for three values of water content: initial water content (compaction), field capacity water content (during infiltration) and saturation water content (capillary barrier formation). The configuration of capillary barriers development in reinforced systems requires that designers account for this phenomenon when using fine-grained backfill soils. Keywords: Geotextiles, Infiltration, Capillary barriers, reinforced soil, drainage 1 INTRODUCTION Although granular soils are recommended in design of geosynthetic reinforced soil structures in North America (FHWA, 1998, AASHTO, 22) and Europe (BS 86, 199), this type of structure has also been constructed using local soils, frequently poorly draining soils. Use of these soils may lead to significant cost savings in areas where granular materials are not readily available (Zornberg and Mitchell, 1994, Stulgis, 2, Pathak and Alfaro, 21). As poorly draining soils are capable of developing pore water pressures, permeable geosynthetics (e.g. nonwoven geotextiles, geocomposites) can be used as a double function material: reinforcement and internal drainage (Ling and Tatsuoka, 1994; Zornberg and Mitchell, 1994, Kempton et al., 2; Tan et al., 2;, Zornberg and Kang, 2; Portelinha et al., 213). However, in-plane drainage of the nonwoven geotextile can only occur after reaching high moisture content (or saturation) of the soil-reinforcement interface. In practical applications, backfill materials present low water contents and, consequently, also have negative pore water pressures (matric suction). Zornberg et al. (21) reports capillary barriers develop in nonwoven geotextiles when the soil suction exceeds a certain value, at which the nonwoven geotextile permeability becomes lower than the permeability of soil. Iryo and Rowe (2) shows by finite element simulation that nonwoven geotextiles act as a drainage material only when the threshold limit is reached and that their drainage performance improves when they are installed with an inclination. Capillary barriers can be understood by the assessment of water flow and storage in porous geomaterials (e.g. granular soils, geosynthetics) under unsaturated conditions. As a material dries, its hydraulic conductivity drops significantly with decreasing saturation degree. The hydraulic conductivity of unsaturated

materials with relatively large pores decreases more significantly than that of fine-grained soils. This characteristic leads to the counterintuitive situation in which the hydraulic conductivity of unsaturated gravel or geotextiles can be significantly smaller than that of fine-grained soils. The specific phenomenon that resists the passage of water from an unsaturated soil into a nonwoven geotextile is referred to as the capillary break effect (Stormont and Anderson 1999). This paper consists of an experimental examination of the infiltration into a geotextile-reinforced soil wall, focusing on the capillary barriers effects and internal drainage effectiveness. It involves monitoring of an instrumented full-scale geotextile-reinforced wall model constructed to evaluate the infiltration in the reinforced fill with specific focus on the interface hydraulic behavior. 2 EXPERIMENTAL PROGRAM 2.1 Materials A Full-scale model was constructed using a lateritic soil. The grain size distribution is presented in Figure 1a. Physical properties of the soil are reported in Table 1. As the soil includes approximately 4% of fine particles, it would not meet the AASHTO (22) specifications. As this study focus in an unsaturated behavior of soil-geotextile interface, the soil water retention curve is provided in Figure 1b. Table 1. Physical properties of soil Properties Standard Gs NBR68 Liquid Limit NBR649 Plasticity index NBR 718 Maximum dry unit weight ASTM D17 Optimum water content ASTM D17 Cohesion ASTM D7181 Friction angle ASTM D7181 Hydraulic conductivity NBR144 Values 2.7 4% 19 17.88 kn/m3 14.6% 1 kpa 32º 4.9x1-7 m/s.4 1 8 6 6.2 4 S (%).3 % passing 8 1 4 Wetting.1 2.1 Drying van Genutchen (Drying) 2 van Genutchen (Wetting).1.1 Particle size (mm) 1 1.1 1 1 1 1 1 1 Matric Suction, ua-uw (kpa) Figure 1. Properties of backfill soil: (a) Grain size distribution; (b) Soil water retention curve. The reinforcement is a polyester needle-punched nonwoven geotextile with a mass per unit area of 293 g/m2, thickness of 2.69 mm, tensile strength of 1 kn/m and strain at failure of 83% (ASTM D49). Hydraulic properties of this geotextile include its permittivity of 1.96 s-1 (ASTM 4491), transmissivity of 6x1-6 m2/s (ASTM 4716) and apparent opening size of 93 µm (AFNOR G38-17). 2.2 Full scale models Full-scale walls were constructed in the Laboratory of Geosynthetics located within the Sao Carlos School of Engineering at the University of Sao Paulo, Brazil. A reinforced steel frame allows the reinforced soil wall structures to be constructed with 1.8 m height by 1. m width, with backfill soil extending to a distance of 1.8 m from the front edge of the metallic box. For this study, the soil was compacted to 98% of relative density and optimum water content in relation to standard Proctor (Table 1). In order to obtain the required relative density, compaction was performed manually in cm high layers. Compaction control

was achieved using the drive-cylinder method (ASTM D2937), spiked every compacted layer reaching 3 cm height. The backfill soil was placed over a rigid concrete foundation. Geotextile reinforcements were placed at 3 cm vertical spacing with a declivity of 1% towards the face. Each layer of reinforcement had a total length of 1.6 m measured from the face. The wall was constructed with no facing batter and using the wrap-around technique. Protective shotcrete coating ranging from to 8 cm in thickness was used. Drainage geocomposites were used as face drainage elements in the second and forth reinforced layers, extending to 3 cm from the face forward into the wall. Figure 2 presents the cross section view of the model. Figure 3a shows a photograph of the model during test. This paper consists of an experimental examination of the infiltration into a geotextile-reinforced soil wall, focusing on the capillary barriers effects and internal drainage effectiveness. It involves monitoring of an instrumented full-scale geotextile-reinforced wall model constructed to evaluate the infiltration in the reinforced fill with specific focus on the interface hydraulic behavior. Airbag for loading ) Rainfall distributionlayer layer Rainfall distribution (drainage geocomposite) (drainage geocomposite) Water content sensors 1 3 Tell tails 2 3 4 Electrical Tensiometers Mechanical tensiometers 3 3 3 Shotcrete b Water tap for volumetric flow rate measurements 1 Rainfall distribution layer (Coarse-grained soil) Water Reserviour 8 6 Nonwoven geotextile (cm) L1 L2 L3 L4 L C1 C2 C3 C4 Layer 1 1 3 16 LVDT 2, cm 1 cm cm cm cm Camada Layer 2, cm Geotêxtil tecido Nonwoven não geotextile 1 6 6 3 16 Figure 2. Cross section of the full-scale reinforced wall model, instrumentation layout and wetting system. 2.3 Wetting system After construction of the wall, a wetting system was installed on the top of the wall surface, which was graded with an inclination of 2% toward the face. The wetting system includes a series of supplying pipes and a water distribution layer placed over the structure. The water distribution layer involves a 1 cm high sand layer and a drainage geocomposite installed over the sand layer. The configuration of the drainage geocomposite and the sand layer provided a uniform water distribution over the top surface. Water was supplied by a reservoir with a float switch enabling constant hydraulic head to induce a uniform rainfall intensity. The intensities of precipitation were controlled by defining of volumetric flow rate in the output water tap installed in the water reservoir, using a bucket and chronometer. Figures 2 and 3b provide details of the wetting system.

b Water supply Geocomposite layer Suppying pipes Water tap for volumetric flow rate measurement Sand layer Figure 3. Full -scale reinforced wall model: (a) frontal view; (b) view of wetting system. 2.4 Instrumentation Instrumentation was installed to monitor positive and negative (matric suction) pore water pressures, water content, internal horizontal displacements and horizontal face displacements. The instruments layout is presented in Fig. 6. As the focus of this paper is on the infiltration, the data on the mechanical response of the wall are not to be reported herein. The advancement of water infiltration into the model was monitored using piezometers with a measurement range of -1 to 1 kpa placed in each reinforced layer cm over the reinforcements. Frequency domain reflection sensors (FDR) were installed to measure the water content in each reinforced layer (located 1 cm over the reinforcement). Four columns and five lines of sensors were specifically concentrated on layer (upper layer), in order to evaluate capillary barriers effects as shown in Fig 6b. 2. Test procedure Data from the multiple instruments installed in the full-scale model were collected during wetting simultaneously. An infiltration rate of 1.8x1-7 m/s was applied over the full-scale prototype, while maintaining a uniform loading of 1 kpa during the entire test. Loading was applied using air bags on the top of the wall and a reaction structure. No pounding occurred on the top of the wall, because the imposed water flow was lower than the hydraulic conductivity of soil (approximately 2. times smaller than the saturated hydraulic conductivity of the soil). 3 RESULTS The water content along each column is shown in Figure 4 for each of the five elevations where sensors had been placed. The positioning of various sensors is also illustrated in Figure 2. As illustrated by the water content data shown in Figure 4, three distinct phases of water flow can be identified after applying a constant infiltration rate in this test. Initially, the entire profile was relatively dry, with an as-compacted volumetric water content of.262, identified herein as the initial volumetric water content (θi). Although the supplied infiltration rate is constant, the wetting front moves through soil layer as a transient process. As the wetting front reaches the location of each of the sensors the water content is observed to increase up to a value of approximately.31, which corresponds to the field capacity volumetric water content (θfc). Once the wetting front reached the top of the geotextile (after 3 to 6 min), water did not immediately flow into the geotextile. Instead, a capillary barrier developed and water accumulated within the soil immediately above the geotextile until the matric suction decreases to a value at which capillary breakthrough occurred (after 1 to 1 min). During the water storage by capillary effect, the water content was approximately.34, which corresponds to the saturation value (θsat). The capillary barriers temporarily prevented infiltration into reinforced layer 4. Specifically, this mechanism retarded the infiltration by 7 days per reinforcement layer, until the threshold level was achieved and pore pressure exceeds the value at which geotextiles become more permeable than soil. After capillary breakthrough, water progress to the underlying layer and transient flow resulted in a moisture towards to the corresponding field capacity water content value.

.36.36 Water storage above geotextile.32.3 Distance from the top:.28 1 cm 1 cm 2 cm 27. cm 3 cm.26 W.C. under geotextile.24 Breakthough of water.32.3 Distance from the top: 1 cm 1 cm 2 cm 27. cm 3 cm.28.26 W.C. under geotextile.24 1 1 2 2 3 3 Water storage above geotextile.34.34 Breakthough of water 1 1 2 2 3 3 Time (min) Time (min) Figure 4. Time history of water content during infiltration: (a) in column location C1; (b) in column location C2. Considering the three distinct water content values occurring during infiltration (θi, θfc, θsat), infiltration profiles were defined for different times of the test. Accordingly, infiltration front advancement could be examined, including the development of capillary barriers. Figure illustrates infiltration profiles at three different times. Using the three distinct water content values allowed a reasonable definition of infiltrations front, even though the field capacity water content showed to be lower in long periods of test, since geotextile drainage reduced the infiltrated volume of water due to in-plane lateral flow..26.28.3.32.34.36.36.34 3.24 3.26 12 1 θsatθsat 6 9 3.34.34.36.36.24 C1 C2 C3 C4 center of layers center of layers 1 3 θi 1 θfc.26.28.3.32.34.36 3 values θsat 12 2 2 1 9 3 θfc.32 values θi.3 values 6.28.24 6 θi θfc θsat 3 9 θsat 2 C1 C2 C3 C4 centerofoflayers layers center 2 12 1 1 C1 C2 C3 C4 center of layers Figure. Infiltration profiles based on VWC after (a) 2 min., (b) 1 min. and (c) 3 min. of irrigation. Progress of the infiltration front into the reinforced soil wall prototype with time is shown in Figure 6a. This plot was defined using the infiltration profiles for different periods of test, as illustrated in Figure. The figure shows predicted infiltration without reinforcements and measured and predicted infiltration with reinforcements. Infiltration without reinforcement was predicted using the rate of the infiltration front based on readings from sensors located in the upper layer before reaching the geotextile. The same approach was used to predict the infiltration with geotextile reinforcements; however, with capillary barriers retarding infiltration. The figures show that the predicted infiltration with geotextile agreed with the experimental values. Additionally, infiltration into the full-scale model without reinforcements was expected to completely occur in 1 days; however, it occurred in 22 days. As regards the internal drainage, this hydraulic behavior was observed with the reduction of saturation degree toward the wall toe, mainly after infiltration front through the layer (Figure c). Figure 6b shows a view of the transparent side of the wall during infiltration in which moisture stains of the face are evidenced exactly along reinforcement elevations.

Tempo(min) (min) Time 1 1 2 2 3 3 4 4 infiltração (cm) z do perfil de (cm) advancement Infiltration 3 Infiltração prevista Predicted infiltration com barreiras with reinforcements capilares 6 Moisture stains line 4 4 3 3 9 Infiltração medida infiltration 2 2 12 Taxa de Predicted infiltration infiltraçãowithout no solo (sem reinforcements 1 reforços) Fig 6. (a) Predicted and measured infiltration advancement with time, (b) Transparent side of the wall. Results have shown positive and negative effects of using geotextiles as reinforcement and internal drains, simultaneously. As positive effects, the internal drainage was clearly observed, even though not measured, which allows the use of fine-grained soil as backfill material of reinforced soil walls. As regards capillary barriers, to predict or design the restriction of water flow by capillary barriers for a specific region can assure that water do not progress to the reinforced zone. This solution keeps the unsaturated condition of the fine-grained backfill, resulting in a good performance of the structure. On the other hand, if the water flow advances to the reinforced zone and capillary barriers formation occurs, resulting in water storage, water pressure can increase and interface shear strength (soil-geotextile) can be reduced. 4 CONCLUSIONS This paper presents the results of an experimental evaluation involving water infiltration into an instrumented full-scale model reinforced with nonwoven geotextiles. Experiments were conducted to examine the effect of the hydraulic responses of nonwoven geotextiles in a fine-grained backfill soil. Based on the analysis and instrumentation results, the following results can be drawn: Capillary barriers were found to develop, which ultimately retarded infiltration in the reinforcement soil mass, until enough water accumulated at the soil-geotextile interface to reach negligible matric suction during infiltration. Infiltration into the full-scale model without nonwoven geotextile reinforcements was expected to occur in 1 days to the wall toe; however, it occurs in 22 days. Therefore, the nonwoven geotextiles used as reinforcements were found to provide beneficial in-plane drainage, but only after enough moisture had accumulated to lead breakthrough. Infiltration monitored properly, using volumetric water content sensors, which allowed identifying three representative values of water content during infiltration: initial compaction water content; field capacity water content; and, saturation water content observed during development of capillary barriers. Reduction of saturation degree toward the wall toe and moisture stains in the concrete wall face provide evidences of the in-plane drainage occurring in the geotextiles after breakthrough. As recommendation, capillary barrier in reinforced systems requires that designers account for this phenomenon when using fine-grained backfill soils since it has a significant influence on drainage capacity. This can be predicted based on water retention curve of both materials in the interface as recommended by Zornberg et al. (21) and others research works.

ACKNOWLEDGEMETS The authors wish to thank the Sao Paulo research foundation (FAPESP) and the National Council of research and technology developments (CNPq) for the financial support and scholarships that allowed to perform and to publish this research. REFERENCES AASHTO 22. Standard Specifications for Highway Bridges. American Association of State Highway and Transportation Officials, Div. 1, Sect., Retaining Walls, Seventeenth Edition, Washington, DC, USA. ASTM D2937 21. Standard Test Method Density of Soil in Place by the Drive-Cylinder method, West Conshohocken, Philadelphia, USA. ASTM D49 211. Standard Test Method for Tensile Properties of Geotextile by the Wide-width Strip Method, West Conshohocken, Philadelphia, USA. ASTM D17 29. Standard test methods for laboratory compaction characteristic of soil using modified effort. American Society of Testing Materials. ASTM D7181 211. Method for consolidated drained triaxial tests for soils. American Society of Testing Materials. ASTM 261 21. Standard test method for measuring mass per unit area of geotextiles, American Society of Testing Materials. ASTM 199 212. Standard test method for measuring nominal thickness of geosynthetics, American Society of Testing Materials. ASTM 4491 29. Standard test methods for water permeability of geotextiles by permittivity. American Society of Testing Materials. ASTM 4716 214. Standard test method for determining the (in plane) flow rate per unit width and hydraulic transmissivity of a geosynthetic using a constant head. American Society for Testing Materials. AFNOR G38-17 1986. FOS from hydrodynamic sieving. French committee on geotextiles. Iryo, T. & Rowe, R. K. 2. Infiltration into an Embankment Reinforced by Nonwoven Geotextiles. Canadian Geotechnical Journal, J. 42: 114-119. Kempton, G. T., Jones, C. J. F. P., Jewell, R. A. & Naughton, P. J. 2. Construction of slopes using cohesive fills and a new innovative geosynthetic material. Proceedings of II European Geosynthetics Conference, Bologna, Italia, p.1-6. Ling, H. I., Wu, J. T. H. & Tatsuoka, F. 1993. Short-term Strength and Deformation Characteristics of Geotextiles under Typical Operational Conditions. Geotextiles and Geomembranes. 11 (2):p. 18-219. Stormont, J. C. & Anderson, C. E. (1999). Capillary barrier effect from underlying coarser soil layer. Journal of Geotechnical and Geoenvironmental Engineering, 12, No. 8, 641 648. Stulgis, R.P. (2). Full-scale MSE Test Walls. Proceedings of NAGS 2/GRI-19 Conference, on CD, Las Vegas, NV, USA. Pathak, Y.P. & Alfaro, M. C. (21).Wetting-drying behavior of geogrid-reinforced clay under working load conditions. Geosynthetics International, 17 (3): 144-16. Portelinha, F. H. M., Bueno, B. S. & Zornberg, J. G. 213. Performance of nonwoven geotextile reinforced soil walls under wetting conditions: laboratory and field investigation. Geosynthetics International, 2 (2), p. 9-14. Tan, S. A., Chew, S. H., Ng, C. C., Loh, S. L., Karunaratne, G. P., Delmas, & Loke, K. H. 21. Large-Scale Drainage Behavior of Composite Geotextile and Geogrid in Residual Soil. Geotextiles and Geomembranes, 19 (3): p.163 176. Tatsuoka, F. & Yamauchi, H. 1986. A Reinforcing Method for steep Clay Slopes using a Non-woven Geotextile. Geotextile and Geomembranes, 4 (3): p. 241-268. Zornberg, J.G. & Mitchell, J.K. (1994). Reinforced soil structures with poorly draining backfills, Part I. Geosynthetics International, 1 (2): p. 13 148. Zornberg, J. G.; Kang, Y. (2). Pullout of geosynthetic reinforcement with in-plane drainage capability. Geosynthetic Research and Development in Progress, GRI-18. Zornberg, J. G.; Bouazza, A. & McCartney, J. S. 21. Geosynthetic capillary barriers: current state of knowledge. Geosynthetics International, v. 17, n., p. 273-3. Zornberg, J. G.; Bouazza, A. & McCartney, J. S. 21. Geosynthetic capillary barriers: current state of knowledge. Geosynthetics International, v. 17, n., p. 273-3.