Series 4XSHV 18 Frame Driver 76mm Spherical Solids Handling

Similar documents
Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

KEENER GRINDER PUMPS

brands you trust. The Next Generation of SH Series Pumps BARNES SH SERIES PUMPS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

The Next Generation of

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

K4RH(X) Solids-Handling Pumps

Reliable Long-Term Solutions For Your Toughest Pump

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

C. SUBMERSIBLE SUMP PUMPS

FLANGE-MOUNT CENTRIFUGAL PUMPS

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

- Sewage and Sludge Pumps

POULTRY MARKET CATALOG

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

NJWEA TECH TRANSFER MARCH 1, 2016

SECTION FIRE PUMP AND CONTROLS

Industrial. Solutions brands you trust. Product Overview

Electric Submersible Pumps

SECTION WASTEWATER PUMPING STATION DESCRIPTION

MARLOW PUMPS RECIRCULATION

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

5. CONDENSATE PUMPS/UNITS

CLOSED COUPLED CENTRIFUGAL PUMPS

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

HOMA Pump, Ansonia Connecticut

Company name: Created by: Phone:

SL EX.4.51D

Electric Submersible Pumps

SL S.S.N.51D

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

CR20-07 A-F-A-E-HQQE 3x400/ HZ

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 3HP THRU 10HP CENTRIFUGAL SUBMERSIBLE GRINDER SEWAGE PUMPS

MULTISAN Fully automatic sewage and waste water pump

INTRODUCTION 09/'16 SUPSD 06/'15

Goulds Trash Hog. Self-Priming Solids Handling Pumps

PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS DB & SP SERIES

Specially Designed Waste Water & Sewage Pumps

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

PUMPS AND CONTROLS. Submittal #1 Pumps. Project Torrance Memorial Medical Center Storm Lift Sation Project #

CR A-F-A-E-HQQE 3x400/ HZ

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

GRUNDFOS PLUMBING & HVAC PRODUCTS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Flygt N-pumps 3231, 3306, 3312, 3356, 3400

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

SELF-PRIMING PUMPS CORNELL PUMP COMPANY STX & STL SERIES INDUSTRY LEADING EFFICIENCY WITH CYCLOSEAL SYSTEM EFFICIENT BY DESIGN FIVE-YEAR WARRANTY

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

CR A-F-A-V-HQQV 3x400D 50 HZ

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

Machine Tool Coolant Units

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

DESCRIPTION IMPELLER INSPECTION MAINTENANCE POWER CORD REPLACEMENT IMPELLER REPLACEMENT MECHANICAL SEAL REPLACEMENT IMPELLER INSPECTION /REPLACEMENT

Pump Installation and Service Manual SPX50/SPX50H Submersible Explosion-Proof Pumps

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

DUPLEX CONDENSATE TANK SYSTEM

Ampco s Complete Line of AC SERIES PUMPS AC, AC+, IC+

Fuji Electronic VFC 084P-5T

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

SUBMERSIBLE SOLIDS HANDLING PUMPS Features and Benefits:

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

SEWAGE PUMPS WITH CUTTER IMPELLER

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Wilo IL Vertical Split-Coupled Inline Pumps

471 US Hwy 250 East, Ashland, Ohio PH: FX:

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

INSTALLATION AND SERVICE MANUAL WHR5H, 10H, 15H, 20H Series Submersible Sewage Pumps

The Replacement Motor & Fan Specialists

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

Dean Pump High Temperature Chemical Process Inline Pumps

CORNELL PUMP COMPANY MINE DEWATERING WHEN RELIABILITY MATTERS

SECTION STEAM CONDENSATE PUMPS

dualarm Vertical In-Line Pumps

Plumbing Supply Products

FEATURES. Other Fed-Flush Arrangements

TP /4-A-F-A-BQQE 400D 50HZ

effluent and drain water pumps FEATURES Efficient Dosing Two-vane cast iron impeller design provides maximum dosing efficiency

Intelligent Variable Speed Pump

Full-line Product Overview

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

CRN A-F-G-E-HQQE 3x400D 50 HZ

Description. Construction

Barnes Oil Sensor Switch

Transcription:

18 Frame Driver 76mm Spherical Solids Handling Specifications: DISCHARGE...4", 125 lb. Horizontal Flange Slotted to accommodate 100mm ISO Flanges LIQUID TEMPERATURE...104 F (40 C) Continuous VOLUTE...Cast Iron ASTM A-48, Class 30 WEAR RING...C954 Lead-Free Bronze MOTOR HOUSING...Cast Iron ASTM A-48, Class 30 SEAL PLATE...Cast Iron ASTM A-48, Class 30 IMPELLER: Design...Vortex, With Pump Out Vanes on Back Side. Dynamically Balanced ISO G6.3 Material...Ductile Iron ASTM A-536, 65-45-12 SHAFT...416 Stainless Steel O RINGS...Buna-N HARDWARE...300 Series Stainless Steel LIFTING BAIL...300 Series Stainless Steel PAINT SEAL:...Epoxy Dupont Corlar Amine Epoxy, Two Coats Design...Tandem Mechanical, Oil Filled Reservoir. Material: Inboard...Rotating Faces - Carbon Stationary Faces - Ceramic Material: Outboard...Rotating Faces - Silicon Carbide Stationary Faces - Silicon Carbide Elastomer - Buna-N Hardware - 300 Series Stainless CORD ENTRY...Custom Molded, Quick Connected for Sealing and Strain Relief POWER CORD...CSA Certifi ed Submersible Power Cable 2000V - Ordered Separately SPEED...1450 RPM (Nominal) UPPER BEARING: Design...Single Row, Ball, Oil Lubricated Load...Radial LOWER BEARING: Design... Double Row, Ball, Oil Lubricated Load...Radial & Thrust MOTOR: Design...NEMA B Three Phase Torque Curve. Oil-Filled, Squirrel Cage Induction, Inverter Duty rated per NEMA MG1 Insulation... Class H Varnish & Magnet Wire SINGLE PHASE... Requires overload protection to be included in control panel. Requires start components to be included in panel. Provided with pump. THREE PHASE... 400V, 1.5-7.5kW. Requires Overload Protection to be Included in control panel. MOISTURE SENSOR... Normally Open (N/O), Requires Relay in Control Panel TEMPERATURE SENSOR... Normally Closed (N/C). To be wired in series with connector control circuit OPTIONAL EQUIPMENT... Seal Material, Impeller Trims, Cord Length, Leg Kit MARKINGS... CSA, CE PUMP WEIGHT... 218 lbs (99 Kg) NOISE EMISSION MAX... In-Air 65 db-a SUBMERGENCE... Max Depth 66ft (20m) RECOMMENDED: Accessories...Break Away Fitting (BAF) Check Valve Control Panel Series: 4XSHV 1.5-7.5kW, 1450RPM, 50Hz Explosion Proof, Class 1, Division 1, Groups C & D, T4 DESCRIPTION: Canadian Standards Association File No. LR16567-25 This product may be covered by one or more of the following patents and other patent(s) pending: US Patents 7,931,473 & 8,128,360 Sample Specifi cations: Section 0.1C Page F. SUBMERSIBLE NON-CLOG SEWAGE PUMP DESIGNED FOR RAW SEWAGE APPLICATIONS. 1 3/17

21 Frame Driver 76mm Spherical Solids Handling Specifications: Series: 4XSHV 11-22kW, 2850RPM, 50Hz 7.5kW, 1450RPM, 50Hz Explosion Proof, Class 1, Division 1, Groups C & D, T4 DESCRIPTION: Canadian Standards Association File No. LR16567-25 This product may be covered by one or more of the following patents and other patent(s) pending: US Patents 7,931,473 & 8,128,360 Sample Specifi cations: Section Page F. SUBMERSIBLE NON-CLOG SEWAGE PUMP DESIGNED FOR RAW SEWAGE APPLICATIONS. DISCHARGE...4", 125 lb. Horizontal Flange Slotted to accommodate 100mm ISO Flanges LIQUID TEMPERATURE...104 F (40 C) Continuous VOLUTE...Cast Iron ASTM A-48, Class 30 WEAR RING...C954 Lead-Free Bronze MOTOR HOUSING...Cast Iron ASTM A-48, Class 30 SEAL PLATE...Cast Iron ASTM A-48, Class 30 IMPELLER: Design...Vortex, With Pump Out Vanes on Back Side. Dynamically Balanced ISO G6.3 Material...Ductile Iron ASTM A-536, 65-45-12 SHAFT...416 Stainless Steel O RINGS...Buna-N HARDWARE...300 Series Stainless Steel LIFTING BAIL...300 Series Stainless Steel PAINT SEAL:...Epoxy Dupont Corlar Amine Epoxy, Two Coats Design...Tandem Mechanical, Oil Filled Reservoir. Material: Inboard...Rotating Faces - Carbon Stationary Faces - Ceramic Material: Outboard...Rotating Faces - Silicon Carbide Stationary Faces - Silicon Carbide Elastomer - Buna-N Hardware - 300 Series Stainless CORD ENTRY...Custom Molded, Quick Connected for Sealing and Strain Relief POWER CORD...CSA Certifi ed Submersible Power Cable 2000V - Ordered Separately SPEED...2850 RPM or 1450 RPM (Nominal) UPPER BEARING: Design...Single Row, Ball, Oil Lubricated Load...Radial LOWER BEARING: Design... Double Row, Ball, Oil Lubricated Load...Radial & Thrust MOTOR: Design...NEMA B Three Phase Torque Curve. Oil-Filled, Squirrel Cage Induction, Inverted duty rated per NEMA MG1 Insulation... Class H Varnish & Magnet Wire THREE PHASE... 400V. Requires Overload Protection to be Included in control panel. MOISTURE SENSOR... Normally Open (N/O), Requires Relay in Control Panel TEMPERATURE SENSOR... Three Normally Closed (N/C). To be wired in series with connector control circuit OPTIONAL EQUIPMENT... Seal Material, Impeller Trims, Cord Length, Leg Kit MARKINGS... CSA, CE PUMP WEIGHT... 399 lbs (181 Kg) NOISE EMISSION MAX... In-Air 73 db-a SUBMERGENCE... Max Depth 66ft (20m) RECOMMENDED: Accessories...Break Away Fitting (BAF) Check Valve Control Panel 2 3/17

28 Frame Driver 76mm Spherical Solids Handling Specifications: DISCHARGE...4", 125 lb. Horizontal Flange Slotted to accommodate 100mm ISO Flanges LIQUID TEMPERATURE...104 F (40 C) Continuous VOLUTE...Cast Iron ASTM A-48, Class 30 WEAR RING...C954 Lead-Free Bronze MOTOR HOUSING...Cast Iron ASTM A-48, Class 30 SEAL PLATE...Ductile Iron ASTM A-536, 65-45-12 IMPELLER: Design...Vortex, With Pump Out Vanes on Back Side. Dynamically Balanced ISO G6.3 Material...Ductile Iron ASTM A-536, 65-45-12 SHAFT 416 Stainless Steel O RINGS...Buna-N HARDWARE...300 Series Stainless Steel LIFTING BAIL...300 Series Stainless Steel PAINT SEAL:...Epoxy Dupont Corlar Amine Epoxy, Two Coats Design...Tandem Mechanical, Oil Filled Reservoir. Material: Inboard...Rotating Faces - Carbon Stationary Faces - Ceramic Material: Outboard...Rotating Faces - Silicon Carbide Stationary Faces - Silicon Carbide Elastomer - Buna-N Hardware - 300 Series Stainless CORD ENTRY...Custom Molded, Quick Connected for Sealing and Strain Relief POWER CORD...CSA Certifi ed Submersible Power Cable 2000V SPEED...2850 RPM (Nominal) UPPER BEARING: Design...Single Row, Ball, Oil Lubricated Load...Radial LOWER BEARING: Design... Double Row, Ball, Oil Lubricated Load...Radial & Thrust MOTOR: Design...NEMA B Three Phase Torque Curve. Oil-Filled, Squirrel Cage Induction, Inverted duty rated per NEMA MG1 Insulation... Class H Varnish & Magnet Wire THREE PHASE... 400V. Requires Overload Protection to be Included in control panel. MOISTURE SENSOR... Normally Open (N/O), Requires Relay in Control Panel TEMPERATURE SENSOR... Three Normally Closed (N/C). To be wired in series with connector control circuit OPTIONAL EQUIPMENT... Seal Material, Impeller Trims, Cord Length, Leg Kit MARKINGS... CSA, CE PUMP WEIGHT... 642 lbs (291 Kg) NOISE EMISSION MAX... In-Air 73 db-a SUBMERGENCE... Max Depth 66ft (20m) RECOMMENDED: Accessories...Break Away Fitting (BAF) Check Valve Control Panel Series: 4XSHV 30kW, 2850RPM, 50Hz Explosion Proof, Class 1, Division 1, Groups C & D, T4 DESCRIPTION: Canadian Standards Association File No. LR16567-25 This product may be covered by one or more of the following patents and other patent(s) pending: US Patent 8,128,360 Sample Specifi cations: Section 0.1C Page F. SUBMERSIBLE NON-CLOG SEWAGE PUMP DESIGNED FOR RAW SEWAGE APPLICATIONS. 3 3/17

76mm Spherical Solids Handling 18 Frame Driver inches (mm) 17.48 (444) 30.53 (775) 6.76 (172) 13.19 (335) 4.33 (110) 18 Frame Driver (4XSHVBA ONLY) Optional Leg Kit - p/n 125506 IMPORTANT! 1.) MOISTURE AND TEMPERATURE SENSORS MUST BE CONNECTED TO VALI THE CSA LISTING. 2.) A SPECIAL MOISTURE SENSOR RELAY IS REQUIRED IN THE CONTROL PANEL FOR PROPER OPERATION OF THE MOISTURE SENSORS. CONTACT BARNES PUMPS FOR INFORMATION CONCERNING MOISTURE SENSING RELAYS FOR CUSTOMER SUPPLIED CONTROL PANELS. 3.) THESE PUMPS ARE CSA LISTED FOR PUMPING WATER AND WASTEWATER. DO NOT USE TO PUMP FLAMMABLE LIQUIDS. 4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS A COMMON OCCURRENCE. 5.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS 1 DIVISION 1 HAZARDOUS LOCATIONS. 4 9/15

76mm Spherical Solids Handling 21 Frame Driver inches (mm) 28 Frame Driver Optional Leg Kit - p/n 125506 IMPORTANT! 1.) MOISTURE AND TEMPERATURE SENSORS MUST BE CONNECTED TO VALI THE CSA LISTING. 2.) A SPECIAL MOISTURE SENSOR RELAY IS REQUIRED IN THE CONTROL PANEL FOR PROPER OPERATION OF THE MOISTURE SENSORS. CONTACT BARNES PUMPS FOR INFORMATION CONCERNING MOISTURE SENSING RELAYS FOR CUSTOMER SUPPLIED CONTROL PANELS. 3.) THESE PUMPS ARE CSA LISTED FOR PUMPING WATER AND WASTEWATER. DO NOT USE TO PUMP FLAMMABLE LIQUIDS. 4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS A COMMON OCCURRENCE. 5.) THIS PUMP IS NOT APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS 1 DIVISION 1 HAZARDOUS LOCATIONS. 5 9/15

6 12/13 XSHVA Pump XSHVB Pump MODEL NO PART NO kw VOLT PH Hz RPM (Nom) NEMA START CODE FULL LOAD AMPS LOCKED 1.2 SERVICE DRIVER ROTOR FACTOR AMPS FRAME AMPS CORD P/N * CORD SIZE CORD NOTES 4XSHVA40X2 134129-50 4.0 220 1 50 2850 G 30.5 34.6 132.8 18 125498 8/4-18/4 SOLD SEPARATELY 4XSHVA40Z2 134130-50 4.0 400 3 50 2850 H 8.1 9.5 47.2 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVA55Z2 133650-50 5.5 400 3 50 2850 J 14.6 16.4 85.8 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVA75Z2 133652-50 7.5 400 3 50 2850 G 17.6 20.5 85.5 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVA110Z2 127426-50 11.0 400 3 50 2850 C 30.0 34.5 84.3 21 125497 12/4-18/4 SOLD SEPARATELY 4XSHVA150Z2 127428-50 15.0 400 3 50 2850 G 33.1 38.5 180.2 21 125497 12/4-18/4 SOLD SEPARATELY 4XSHVA185Z2 127430-50 18.5 400 3 50 2850 E 39.9 47.3 180.2 21 125499 8/4-18/4 SOLD SEPARATELY 4XSHVA15X4 134286-50 1.5 220 1 50 1450 J 15.51 16.38 67.5 18 125496 12/4-18/4 SOLD SEPARATELY 4XSHVA15Z4 134287-50 1.5 400 3 50 1450 M 4.07 4.51 31.8 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB40X2 134131-50 4.0 220 1 50 2850 G 30.5 34.6 132.8 18 125498 8/4-18/4 SOLD SEPARATELY 4XSHVB40Z2 134132-50 4.0 400 3 50 2850 H 8.1 9.5 47.2 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB55Z2 133655-50 5.5 400 3 50 2850 J 14.6 16.4 85.8 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB75Z2 133657-50 7.5 400 3 50 2850 G 17.6 20.5 85.8 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB110Z2 127476-50 11.0 400 3 50 2850 C 30.0 34.5 84.3 21 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB150Z2 127478-50 15.0 400 3 50 2850 G 33.1 38.5 180.2 21 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB185Z2 127480-50 18.5 400 3 50 2850 E 39.9 47.3 180.2 21 125499 8/4-18/4 SOLD SEPARATELY 4XSHVB220Z2 127482-50 22.0 400 3 50 2850 D 47.3 56.9 180.2 21 125499 8/4-18/4 SOLD SEPARATELY 4XSHVB300Z2 127485-50 30.0 400 3 50 2850 G 56.0 67.0 329.0 28 130907 6/4-18/4 INCLUDED WITH PUMP 4XSHVB370Z2 127487-50 37.0 400 3 50 2850 F 69.9 82.8 329.0 28 130908 2/4-18/4 INCLUDED WITH PUMP 4XSHVB15X4 134295-50 1.5 220 1 50 1450 J 15.51 16.38 67.5 18 125496 12/4-18/4 SOLD SEPARATELY 4XSHVB15Z4 134296-50 1.5 400 3 50 1450 M 4.07 4.51 31.8 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB22X4 134298-50 2.2 220 1 50 1450 E 18.11 20.46 67.5 18 125496 12/4-18/4 SOLD SEPARATELY 4XSHVB22Z4 134299-50 2.2 400 3 50 1450 K 5.24 6.07 31.8 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB40X4 134301-50 4.0 220 1 50 1450 E 32.65 36.32 111.0 18 125498 8/4-18/4 SOLD SEPARATELY 4XSHVB40Z4 134302-50 4.0 400 3 50 1450 G 8.63 10.15 44.2 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVB55Z4 134304-50 5.5 400 3 50 1450 G 13.90 16.30 62.1 18 125497 12/4-18/4 SOLD SEPARATELY IMPORTANT! Moisture and Temperature sensor leads are integral to power cord. Pump rated for operation at ± 10% voltage at motor. * Cord Suffi x: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet. 76mm Spherical Solids Handling

7 9/15 XSHVBA Pump MODEL NO PART NO kw VOLT PH Hz RPM (Nom) NEMA START CODE FULL LOAD AMPS LOCKED 1.2 SERVICE DRIVER CORD ROTOR FACTOR AMPS FRAME P/N * AMPS CORD SIZE CORD NOTES 4XSHVBA185Z2 139117 18.5 400 3 50 2850 E 39.9 47.3 180.2 21 125499 8/4-18/4 SOLD SEPARATELY 4XSHVBA220Z2 139118 22.0 400 3 50 2850 D 47.3 56.9 180.2 21 125499 8/4-18/4 SOLD SEPARATELY 4XSHVBA300Z2 139119 30.0 400 3 50 2850 G 56.0 67.0 329.0 28 130907 6/4-18/4 INCLUDED WITH PUMP 4XSHVBA370Z2 139120 37.0 400 3 50 2850 F 69.9 82.8 329.0 28 130908 2/4-18/4 INCLUDED WITH PUMP 4XSHVBA40X4 138970 4.0 220 1 50 1450 E 32.65 36.32 111.0 18 125498 8/4-18/4 SOLD SEPARATELY 4XSHVBA40Z4 138971 4.0 400 3 50 1450 G 8.63 10.15 44.2 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVBA55Z4 138972 5.5 400 3 50 1450 G 13.90 16.30 62.1 18 125497 12/4-18/4 SOLD SEPARATELY 4XSHVBA75Z4 138973 7.5 400 3 50 1450 H 22.00 24.50 91.7 21 125497 12/4-18/4 SOLD SEPARATELY IMPORTANT! Moisture and Temperature sensor leads are integral to power cord. Pump rated for operation at ± 10% voltage at motor. * Cord Suffi x: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet. 76mm Spherical Solids Handling

4-7.5kW, 2850RPM, 50Hz, 18 Frame 4XSHVA Pump 8 5/12

1.5-2.2kW, 1450RPM, 50Hz, 18 Frame 4XSHVA Pump 9 5/13

11-18.5kW, 2850RPM, 50Hz, 21 & 28 Frame 4XSHVA Pump 10 5/12

4-7.5kW, 2850RPM, 50Hz, 18 Frame 4XSHVB Pump 11 5/12

1.5-5.5kW, 1450RPM, 50Hz, 18 Frame 4XSHVB Pump 12 5/13

11-30kW, 2850RPM, 50Hz, 21 & 28 Frame 4XSHVB Pump 13 5/12

1.5-7.5kW, 1450RPM, 50Hz, 18 & 21 Frame 4XSHVBA Pump 14 9/15

18.5-37kW, 2850RPM, 50Hz, 21 & 28 Frame 4XSHVBA Pump 15 9/15