Alarm System Performance Metrics

Similar documents
Alarm Management Reflections

Alarm Management Services

Economic and Effective Alarm Management

The Top 10 Worst Performing Alarm Systems in Industry

excellence in Dependable Automation ALARM MANAGEMENT

SCADA ALARM MANAGEMENT. Tim Okely. GWMWater

Too Many Alarms: Where Do I Begin?

Effective Alarm Management for Dynamic and Vessel Control Systems

Improvements in Transmission Control Center Alarm Management Practices

Alarm Management. Alarm Management. DeltaV Whitepaper. February 2011 Page 1

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

Exaquantum/ARA Alarm Reporting and Analysis

excellence in Dependable Automation The Alarm Shelving ebook

Alarm Management Optimization (AMO) at Saudi Aramco

Alarm Services. Introduction. Benefits. Service Data Sheet October Know and improve your alarm performance

Alarm Management Standards Are You Taking Them Seriously?

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

Alarm Rationalization

2012 Honeywell Users Group EMEA Tyron Vardy A Guide to Effective Alarm Management

Where Technology Shapes Solutions. Alarm management : Wasn t that problem already solved years ago?

Alarm Management Plan

Alarm Management for SCADA control rooms

Session Number: 3 Making the Most of Alarms as a Layer of Protection

2012 Honeywell Pacific Users Group. Sus tain.ability.

DynAMo Alarm & Operations Management

Alarm Management. Version Prepared by: Michael Davis- Hannibal. Softcon Software Control Services (Pty) Ltd.

DON T JUST REPORT ON ALARMS, TAKE

Current Trends in SCADA Systems. Situational Awareness Alarm Management Data Availability System Robustness/Redundancy

Product Brief for Alarm Analytics V9.2 April 2010

DeltaV Distributed Control System December 2017

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring

Ovation Alarm Management System

Benchmarking Industry Practices for the Use of Alarms as Safeguards and Layers of Protection

Product Brief for Alarm Analytics V9.3 October 2013

Embracing Change: High Performance Graphics to Improve Operations Water/Wastewater Case Study

SCADA 101 Introduction to SCADA Systems - Sensors, Data and Screens

Alarm Management Implementation on a Plant. Standards Certification Education & Training Publishing Conferences & Exhibits

Understanding and Applying the ANSI/ISA 18.2 Alarm Management Standard

Alarm Management: EPRI Survey on the State of Technology

Alarm Benchmark Module By Konnection Introduction Overview Description

DeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience

Meeting PHMSA Alarm Management Requirements: How TiPS Can Help

Fire and Gas Mapping- Updates to ISA84 TR7

Is your current safety system compliant to today's safety standard?

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell

Alarm Management for Pipelines

FAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN

Fire and Gas Detection and Mitigation Systems

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Diagnostics with fieldbus

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

Alarms play a significant role in maintaining plant

ISA 18.2 WG8. Purpose Definitions Status. By: Lieven Dubois, Co-chair

Enhance Alarm Management

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

ABB Ability System 800xA Alarm Management

Presented at the ISPE ISA Automation Forum VP, Engineering Services

Understanding the New IEC Alarm Management Standard A PAS White Paper

Managing Alarms to Support Operational Discipline

Monitor Alarms and Events

Control System Studio - CSS - Alarm Handling

USER APPROVAL OF SAFETY INSTRUMENTED SYSTEM DEVICES

Next Generation Alarm Management With DynAMo Alarm and Operations Management

Focus on Respiratory Care & Sleep Medicine Irvine, CA. Alarm Management. September 14-15, 2018

Table of Contents PART I: The History and Current Status of the Industrial HMI PART II: Fundamentals of HMI Design and Best Practices

Understanding and Applying the ANSI/ ISA 18.2 Alarm Management Standard in Australia

FIRE PROBABILISTIC SAFETY ASSESSMENT FOR KUDANKULAM NPP IN INDIA. G.Tokmachev. Atomenergoproekt, Bakuninskaya 7, Moscow, Russia

Product introduction Layers of Protection Layer 3: Safety System Instrumented & Mechanical. Layer 2: Alarms Manual action needed

Alarm and Event Analysis for Batch Process Improvement

Research to Inform and Improve Recycling in the Workplace. Webinar February 4, 2015

Scope of Work Urban Design Review Framework Monitoring Program Item #7.1

Implementing Safety Instrumented Burner Management Systems: Challenges and Opportunities

Effective Use of Statistical Models to Establish and Update Vibration Alarm

L automazione al servizio della manutenzione nell industria di processo

Evaluation of Strobe Lights in Red Lens of Traffic Signals

PERFORMANCE HUMAN NEXT-GENERATION SCADA HIGH. MACHINE INTERFACES Configuring HMIs to Display Operator-centric Information

JCI - Smoke Control Systems Overview 10/27/2016

Why AC800M High Integrity is used in Burner Management System Applications?

Building Automation Systems from Grantek: Going Beyond Compliance to Improve Operations

Alarm Enforcement or not?

HAZARDS EQUAL TRIPS OR ALARMS OR BOTH

Hazards Equal Trips or Alarms or Both

2000 Series. Program Entry Guide. Control Panels

Options for Developing a Compliant PLC-based BMS

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

2013 Compliance Report RCW 52.33

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

Critical Condition Management on a Corporate Scale. Lyondell Is a Major Global Chemical Company

Emerson Strategies for Abnormal Situation Avoidance & Alarm Management. Executive Overview... 3

Dennis Mullen System Operations Manager

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

Closing the Holes in the Swiss Cheese Model Maximizing the Reliability of Operator Response to Alarms

INSIGHTS GAINED FROM A REVIEW OF FIRE PRA RISK CONTRIBUTION BY IGNITION FREQUENCY BINS

Compact HMI Overview

Relay Performance Index for a Sustainable Relay Replacement Program

BRIDGING THE SAFE AUTOMATION GAP PART 1

Safety Instrumented Systems

L automazione al servizio della manutenzione

Alarm Tone Generator Model AG17

Architectural and Engineering Specification for a Security Management System. StarNet 2

Transcription:

Alarm System Performance Metrics FPID Symposium, Cork March 2016 Standards Certification Education & Training Publishing Conferences & Exhibits

Presenter Kim Van Camp is the Emerson Process Management DeltaV Marketing Product Manager for Alarm Management. He joined Emerson in 1976 and has held senior assignments in Manufacturing, Technology, Field Service, Customer Service, Service Marketing and Product Marketing. Kim is a voting member of the ISA-18.2 committee on Management of Alarm Systems for the Process Industries and has published multiple papers on alarm management. Kim holds a BS degree in Electrical Engineering from the University of Nebraska. 2

Presentation Abstract This presentation centers on the primary metrics commonly used to quantify alarm system performance; how they are constructed, benchmark performance targets, and typical causes for under-performance. The foundation of the presentation is Technical Report ISA- TR18.2.5-2012 Alarm System Monitoring, Assessment, and Auditing, supplemented by speaker insights gained from reviewing hundreds of performance reports received from process plants worldwide in multiple industries. 3

Reference Material TECHNICAL REPORT ISA-TR18.2.5-2012 Alarm System Monitoring, Assessment, and Auditing Approved 26 October 2012 4

Performance Metrics Performance metrics are usually targeted toward operations management. These metrics are broad indicators of alarm system performance, which should be assessed by comparison to performance goals stated in the alarm philosophy. These metrics may not identify specific problems. Average alarm rate Percent of time the system is in a flood condition Quantity and listing of out-of-service-alarms Alarm priority or type distribution 5

Diagnostic Metrics Diagnostic metrics are usually targeted toward the alarm system owner and personnel responsible to take action. These metrics identify specific problems with specific alarms. Listing and quantity of the most frequent alarms Listing and quantity of chattering alarms Listing of stale alarms Listing of shelved alarms with shelving duration Listing of out-of-service alarms with durations Listing of alarms shown by analysis to be potentially redundant 6

Deployment Metrics Deployment metrics are usually targeted toward alarm system owners and responsible personnel to measure progress on implementing alarm management practices. Percent of alarms rationalized Percent of alarms monitored Priority distribution of rationalized alarms. 7

Scaling Metrics Scaling metrics are measurements used to determine other metrics. This includes such items as: Number of configured alarms for a particular system Number of alarm occurrences for a particular system or group of systems. Scaling metrics are not directly used or reported, but are used in reporting other metrics. 8

Audit Metrics Audit metrics include the data on alarm systems that have been audited. These metrics include: Number and nature of unauthorized alarm changes; Number and nature of unauthorized alarm suppression. Audit metrics are usually targeted toward alarm system owners and operations personnel. These metrics can be used to measure execution of alarm management procedures stated in the alarm philosophy, e.g., management of change. 9

ISA-18.2 Suggested Target Values Metric Target Annunciated Alarms Per Day Per Operating Position 150 300 Annunciated Alarm Per Hour Per Operating Position 6 12 Annunciated Alarms Per 10 Minutes Per Operator Position 1 2 Percent of 10 minute periods containing > 10 alarms < 1% Maximum number of alarms in a 10 minute period <=10 Percent of time the system is in flood < 1% Annunciated Priority Distribution (Low Priority) ~80% Annunciated Priority Distribution (Med Priority) ~15% Annunciated Priority Distribution (High Priority) ~5% Percent contribution of top 10 most frequent alarms < 1% to ~5% Quantity of Chattering and Fleeting Alarms 0 Stale Alarms (Active for more than >24 hours) < 5 on any day Alarm performance based upon at least 30 days of data. 10

Sample Data Sets Performance and diagnostic metrics from 236 systems collected in in 2014-2015 Most are starting-point metrics, prior to nuisance alarm elimination and rationalization These were whole-system reports, nominalized by system IO count and number of operator positions for this presentation. 11

Average Alarm Rate A useful initial measure of the overall performance of the alarm system. The average alarm rate is the most common alarm system performance metric. Periods of unusually high alarm activity are easily identified in trend charts. 12

Average Alarm Rate Per Hour Per Operator Workstation 29.0 alarms/hr. for all industries 8.1 alarm/hr. For Food & Pharma Alarm Rate Acceptable Manageable Demanding Unacceptable Per 1 Hour ~ 6 Alarms ~12 Alarms ~ 30 Alarms > Alarms 13

What can we learn from average alarm rates? If very low. Then probably good. If very high. Need to know more. 14

Alarm Rate By System Per Hour Per Operator Workstation Per individual system it varied from near zero to 1063 alarms / hour! 15

Averages and Alarm Floods Averages can be misleading, providing no sense of peaks in the alarm rate, making it difficult to distinguish alarm floods vs. steady-state normal operation. An alarm flood can be defined as beginning when the alarm rate exceeds 10 or more alarms occurring in 10 minutes, and ending when the rate drops below 5 alarms in 10 minutes (a short-term manageable rate). 16

Percent of Time In Alarm Flood xx 17

Average Alarm Rates Per Operator Position Excluding Alarm Floods 1.6 alarms/hr. for all industries 0.8 alarm/hr. For Food & Pharma Alarm Rate Acceptable Manageable Demanding Unacceptable Per 1 Hour ~ 6 Alarms ~12 Alarms ~ 30 Alarms > Alarms 18

Average Alarm Rates Per Operator Position During Alarm Floods 73.8 alarms/hr. for all industries 18.0 alarm/hr. For Food & Pharma Alarm Rate Acceptable Manageable Demanding Unacceptable Per 1 Hour ~ 6 Alarms ~12 Alarms ~ 30 Alarms > Alarms 19

Typical Problems Associated With A High Alarm Rate Excluding Floods Chattering alarms System and device maintenance alarms Non-alarm notifications Messages Prompts Alerts Metric calculations? 20

Typical Problems Associated With A High Alarm Rate During Floods Redundant Alarms Cascading Alarms Process state transitions where the alarm system is not designed to follow the process 21

Alarm Flood Severity Flood severity based on the most alarms received in a single ten minute period: 10 to 20 alarms minor flood 20 to 30 alarms moderate flood > 30 alarms severe alarm flood In a severe flood, the alarm system can become a hindrance or distraction, rather than acting as a useful tool to assist the operator. During such periods, alarms are likely to be missed. 22

Most extreme alarm floods, Max. count of alarms in a 10 minute period XX 23

Alarm Priority Distribution Prioritization of alarms provides a mechanism for placing a qualitative value on the importance of the alarm. The priority of an alarm determines its significance and how quickly the operator should respond to an alarm. Proper guidelines for a recommended three-priority system distribution are widely known and reflected in ISA-18.2, namely: ~80% Low Priority ~15% Medium Priority ~5% High Priority 24

High Priority alarm percentages Average High Priority Alarm Percent of Total Alarms: 25

Typical Problems Associated With A High Percent of High Priority Alarms Alarms based on ultimate (unmitigated) consequences rather than direct (proximate) consequences Priority used to classify alarms for reasons other than guiding operator on order of actions Chattering high priority alarms, often system and device alarms Priorities left at vendor default settings 26

Top 10 Source Contribution To Total Alarm Count Relatively few alarms often produce large percentages of the total system alarm load. Substantial performance improvement can be made by addressing the most frequent alarms. 27

Top 10 Alarm Source Contribution By Industry and World Area Average Top 10 Alarm Percentage Per System: 28

Typical Problems Associated With A High Top 10 Percentage Nuisance alarms alarms that operators have come to expect, and in most cases, ignore or consider to be informational The alarm system is being misused to (frequently) generate operator prompts based on routine changes in process conditions or operating states 29

Stale Alarms Alarms which remain in the alarm state continuously for a substantial time period. (24 hours is a recommended value for analysis) They often last for days, weeks, or months. Following their initial appearance, such alarms provide little valuable information to the operators. They clutter the alarm displays and interfere with the operator s ability to detect and respond to new and meaningful alarms. 30

Stale Alarm Quantification Snapshot Method: Number present at a certain time of day. Takes into account any local operator alarm filtering which can be difficult or impossible to discern in the event history, providing the truest indication of actual operator experience Allows Direct comparison to ISA benchmark. Tally Method: A count of the number of alarms annunciations that reached an old age (e.g. 24 hours) during a fixed time period (typically a week or month) Can be applied uniformly to the ubiquitous OPC accessible event data available from multiple process control, safety and other systems Can generate ordered lists of the longest standing alarms for continuous improvement efforts 31

Stale Alarm Tallies By Industry and World Area Stale Alarm Tally Per 30 Days Per Operator Position: 32

Typical Problems Associated With Stale Alarms Not following one of the basic principles of alarm management, that alarms should be produced only upon abnormal conditions. For example, standby or other equipment that is intentionally shut down should not produce alarms simply because they are off. Alarms that persist beyond the called-for operator action, waiting for maintenance action. Alarms that are essentially latched due to excessive application of hysteresis. 33

Key Ideas and Thoughts Identify and resolve nuisance alarms, to get a more realistic picture when reviewing subsequent alarm rate metrics. A substantial reduction in configured alarms is the usual result of alarm rationalization, along with a resulting alarm priority distribution close to recommended values. Stale alarms are usually addressed by examination of the cause and application of logic or state-based techniques. Alarm floods are more difficult to address, often involving a dynamic alarm management solution. ISA-TR18.2.5-2012 is an excellent resource for interpreting alarm metrics and common causes.

Discussion 35