Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

Similar documents
Rental Housing Inspection Guide

Rental Registration & Safety Inspection Program: Inspection Checklist

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

BUILDER S PRE-INSPECTION CHECKLIST

BUILDER S PRE-INSPECTION CHECKLIST

Short-Term & Accessory Short-Term Rental Safety Certification

El 0. El 0. El El. El El. El 0 TWO FAMILY HOUSING INSPECTINO CHECKLIST

General Room Standards. Room Electrical Requirements

Section 8 Housing Choice Voucher Program. Housing Quality Standards (HQS) Inspection Checklist

Maintaining Your Rental Property Part 2. An Overview of the Local Laws that Apply to Rental Properties. Please Sign In

PLAN REVIEW SUBMITTAL GUIDE

Montgomery County Land Bank PRE SALE INSPECTION REPORT

Conversion to Vacation Home Permit Life Safety Survey

2012 B.C. Building Code Compliance Review (Division B Part 3)

City of Madison Heights Landlord Licensing Program 300 W. Thirteen Mile Road Madison Heights, MI (248)

Tarrant County Community Development Division

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Short Term Accommodations Fire Code Requirements

REQUIREMENTS & GUIDELINES

CHAPTER 7 ALTERATIONS LEVEL

Agency for Health Care Administration

Habitability Guidelines

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Code verification sign-off

Apartment Fire & Safety Inspection. City of Guadalupe

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

City of Rehoboth Beach

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

BC Building Code Checklist Part 3 Planning and Development Department

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

RENTAL INSPECTION CHECKLIST

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Lighthouse. Prepare for your LHA inspection. Inspection Guide

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

OFFICE USE ONL Y BELOW

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Agency for Health Care Administration

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

CMHC HOME MAINTENANCE CHECKLIST

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Certificate of Inspection CHECKLIST

Code Compliance Report

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

PENNSYLVANIA. Downloaded

BUILDING DIVISION. Multi-family Rental Inspection Program SELF-CERTIFICATION APPLICATION

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Agency for Health Care Administration

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Code Compliance Report

Residential Care Facilities Requirements

Axiom Property Inspections

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Washoe County Department of Social Services

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Residential Based Care Facility Guidelines

Home Maintenance Schedule

Family Foster Home Fire Safety Evaluation Checklist Instructions

* Not all chapters have significant changes covered in this handout.

CONNECTICUT. Downloaded

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

Osceola County Department of Fire Rescue and Emergency Medical Services

ALABAMA. Downloaded

FAIRA TRANSPARENCY REPORTS. November 21, 2016

BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

January 1, 2014 Mandatory Effective Date

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

HOME REHABILITATION LOAN PROGRAM MINIMUM PROPERTY STANDARDS

fieldwork report contains the Functional

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

INTERIOR FINISH REVIEW

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

I. STRUCTURAL SYSTEMS

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Smoke Alarms and Carbon Monoxide Alarms

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Chapter Nursing Homes

Residential-based Care Facility R-4 Guideline

Code Compliance Report

Transcription:

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN 55021 www.faribault.org (507) 333-0359 Property Address: Number of Units Building Type Name & Contact #: Property Information Total: Rental Units: Owner Occupied Units: Single Family Duplex (2 units) Triplex (3 units) Four-plex (four units) Apartment (5+ units) Manufactured Home Mixed Use Faribault, MN 55021 (commercial/residential) Parking # of off-street parking stalls: Exterior [IPMC 302] Premises kept in clean, safe & sanitary condition Soil graded to prevent erosion & stagnant water Walkways, driveway & parking maintained Free from (noxious) weeds, tall grass Free from rodent harborage & infestation Vents, etc. not discharging onto adjacent property Accessory structures maintained No inoperative or unlicensed motor vehicles No damage or defacement of property Exterior Structure [IPMC 304] Maintained in good repair & structurally sound Exterior surfaces in good repair, no unprotected wood House numbers (min. 4" high, visible from street) Structural supports maintained & adequately sized Foundation plumb & free from open cracks Exterior walls weatherproof & maintained Roof, flashing & gutters weatherproof & maintained Cornices, decorative brick, etc. in sound condition Soffits, overhangs, etc. maintained & securely fastened Exterior stairs, decks, porches, etc. maintained & structurally sound Chimneys structurally safe & in good repair Handrails & guards fastened & in good repair Window & door frames weather tight All glazing free from cracks & holes All windows easily openable & remain open Insect screens provided & in good repair Doors & locks maintained & operable Basement hatchways (bulkhead enclosures) maintained weather & rodent tight Basement windows protected against rodents Building Security: Unit doors equipped with dead bolt Locks to open without keys or special knowledge Windows within 6 ft of grade are lockable Basement hatchways secured against entry Interior Structure [IPMC 305] Maintained in clean & sanitary condition Structural support maintained & adequately sized Interior surfaces maintained in good condition Stairs, walking surfaces in sound condition Handrails & guards fastened & in good repair Doors fit well, open & close as intended Handrails & Guardrails [IPMC 306] Handrails on all flights of stairs with more than four risers Min. 30 inches, max. 42 inches above the nosing Guardrails on open sides of stairs, landings, ramps, decks, etc. more than 30 inches above floor or grade below Min. 30 inches high with intermediate rails Rubbish & Garbage [IPMC 307] Free from accumulation of rubbish & garbage Rubbish & garbage placed in approved containers Owner provides leakproof, covered, outside garbage containers Doors removed on abandoned, stored refrigerators Extermination [IPMC 308] All structures free from insect & rodent infestation (Extermination not to be hazardous to human health, precautions taken against re-infestation) C:\Users\Rhanson\Desktop\Bldg Code\Initial Inspection Checklist (3&more Units) June 2013.doc

Light [IPMC 402] Each habitable space has at least one window Glazing shall be min. 8% of total floor area Other spaces have adequate lighting Multi-unit Dwellings (more than 2 units): adequate light on common halls & stairs min. 60 watt per 200 sq ft, max. 30 ft between Ventilation [IPMC 403] Min. one openable window in every habitable space Total openable area to be min. 45% of required glazing (see above) Window or mechanical ventilation in every bathroom & toilet room Exhaust vents where fumes, gases, etc. produced Clothes dryers exhausted per manuf. instructions Rooming Houses & Dorms: No cooking appliances in units Occupancy Limitations [IPMC 403] Dwelling units provide privacy Habitable rooms are min. 7 ft wide Kitchen passageways are min. 3 ft clear Habitable spaces have min. 7 ft ceiling height Unfinished basements min. 6 ft-4 in ceiling height Min. 1/3 of required floor area in bedrooms with sloped ceilings shall have min. 7 ft ceiling height Max. 1 family per unit (City Unified Dev. Ordinance Section 1-120, see definition of Family) Room available for food prep., storage & disposal Bedrooms & Living Rooms: Living room is min. 120 sq ft Each bedroom is min. 70 sq ft Access to bedroom not through another bedroom Access to bathroom not through a bedroom No sleeping in kitchens & unfinished spaces Efficiency Units (max 3 occupants): 1-2 occupants: min. 220 sq ft 3 occupants: min. 320 sq ft Kitchen sink, stove, refrigerator each have a clear working space of 30 inches in front Separate bathroom (min. sink, toilet, shower) Required Facilities [IPMC 502] Each unit has bathtub or shower, lavatory, toilet & kitchen sink Rooming Houses: Min. 1 toilet, lav. & bathtub or shower per 4 units Toilet Rooms [IPMC 503] Bathroom is not used as passageway Bathroom has lockable door Rooming Houses & Dorms: Max. 1 flight of stairs to bathroom Plbg Systems & Fixtures [IPMC 504] Fixtures are properly installed & maintained Fixtures have adequate clearance No hazards in plumbing system to occupants or structure may include: undersized piping, inadequate venting, cross connections, lack of backflow prevention, damaged or worn piping or fixtures, inadequate support, inadequate water pressure or volume Water System [IPMC 505] Sinks, laundry facilities, bathtubs & showers have hot & cold running water All water inlets located above flood-level rim of fixtures Hose bibs & faucets with permanently attached hoses have vacuum breakers Water heaters: Adequate combustion air in small rooms Temp. & pressure-relief valve & discharge pipe Electrical & gas lines properly installed Accessible gas shut off valve Approved vent/chimney; approved material in good condition; adequate slope, clearance & support Sanitary Drainage System [IPMC 506] All fixtures properly connected to sewer Every stack, vent, waste & sewer line in good condition Sanitary drainage system free of leaks, approved materials, correct slope, free of patching Fixture vents provided & maintained Each fixture has a trap Adequate support on all piping Storm Drainage [IPMC 507] Drainage of roofs & paved areas does not cause a public nuisance Storm water discharged away from structures Page 2 of 6

Heating Facilities [IPMC 602] Heating facilities capable of maintaining 68 F in all habitable rooms, bathrooms & toilet rooms (Measured 3 ft above the floor, min. 2 ft from wall) Forced-air heat: Separate furnaces serve each unit [2006 MN Mechanical Code, Section 618.7] Mechanical Equipment [IPMC 603] All equipment properly installed & maintained All fuel-burning equipment connected to approved chimney or vent (Unvented heaters & decorative appliances are not allowed in any dwelling [MN Mech. Code, Sec. 620]) Clearances to combustibles maintained Safety controls maintained in effective operation Combustion & ventilation air provided in the space containing fuel-burning equipment Energy conservation devices installed are labeled & approved Electrical Facilities [IPMC 604] Min. 60-amp service with proper fusing & overcurrent protection No hazards in electrical system to occupants or structure may include: insufficient receptacle distribution, lack of sufficient lighting, damaged or worn wiring, improperly installed wiring, lack of grounding, inadequate support, exposed conductors, missing cover plates, excessive use of extension cords, overloaded receptacle or circuitry, lack of GFCI protection Electrical Equipment [IPMC 605] All equipment properly installed & maintained Min. 1 lighting fixture in every hall, stairway, toilet room, bathroom, kitchen, laundry & mechanical room Receptacles: Every habitable space has min. of 2 (separated) Laundry outlet to be grounded and/or GFCI Every bathroom has min. 1 receptacle (New receptacles to be GFCI protected) Elevators & Dumbwaiters [IPMC 606] Most current certification of inspection on display (Annual testing required per MR Chapter 1307) Min. 1 elevator in operation when available Duct Systems [IPMC 607] Functional & maintained free of obstructions Means of Egress [IPMC 702] Safe, continuous & unobstructed path to public way Egress doors do not need keys, special knowledge or effort to unlock from the inside Emergency Escape Openings: Maintained to code in effect at time of construction Operational without the use of keys or tools Bars, grills & grates are releasable/removable from inside without key, tool or force greater than that of window Fire-Resistance Ratings [IPMC 703] Fire-resistance-rated walls, fire stops, shaft enclosures, partitions & floors are maintained Opening protectives maintained & operable Fire & smoke barrier doors are not blocked or inoperable Fire Protection Systems [IPMC 704] All fire detection, alarm & suppression devices are maintained & operable Alarms located outside bedrooms, in each bedroom & on each story (including basements) Alarms hardwired & interconnected in new construction Fire extinguishers in all apartment buildings IFC906 CO Alarms [MN Stat. 299F.50] Alarm located within 10 ft of every bedroom (May be exempted if no gas appliances) Housing Inspector Applicable Codes Questions? If you have any questions about this form or the Rental Registration Program, please contact the Community Development Department at: 507-333-0359 2006 International Property Maintenance Code [IPMC] as adopted & amended by the City of Faribault 2007 Minnesota State Fire Code [MSFC] as adopted by the City of Faribault Page 3 of 6

Requirements on this page are for buildings with more than two dwelling units Excerpted from State Fire Marshal Div. Information Sheet Combustible Waste [MSFC 304] No accumulation of combustible waste Dumpsters are min. 5 ft from combustible walls Fueled Equipment [MSFC 313] Vehicles & lawn-care equipment & portable cooking equipment is not stored or repaired inside building (Except when building is sprinklered & fuel does not exceed 10 gallons) Combustible Materials [MSFC 315] Storage of materials is orderly & separated from heaters Storage in attics, concealed spaces & under stairs and floors protected by 1-hour fire-rated construction or a sprinkler system Fire Extinguishers [MSFC 906] Max. 50 ft travel distance, Type 2-A:10-B:C (or Type 1-A:10-B:C if in each unit) Conspicuous, unobstructed location, mounted on supplied bracket Quick check performed each month Inspected annually per NFPA 10 & records kept Exits & Egress Egress Illumination: [MSFC 1006] Emergency lighting installed & maintained in common egress areas (except where units have direct access to grade) Hardwired with backup power Exit Signs: [MSFC 1011] Exit signs unobstructed & illuminated at all times Hardwired with backup power Stairway Identification: [MSFC 1020] Signs on each floor landing Required on stairways connecting 3 or more floors Emergency Escape: [MSFC 1026] Every bedroom has a second means of egress: (not required with approved sprinkler system) - An egress window (see attached worksheets) - A door leading directly to exterior - Second means of egress through non-lockable space, sufficiently separate from primary exit Exits: [MSFC 1015] Second exit door required from an area when: Floor has an occupant load of 10 or more (square footage of more than 2000 sq ft) The common path of egress travel exceeds 75 ft (125 ft in buildings with a sprinkler system) Exit Access: [MSFC 1027] Max. 200 ft from most remote point within a story (Max. 250 ft in buildings with a sprinkler system) Dead-End Corridor: [MSFC 1027] Max. length of 50 ft Fire-Resistive Construction Occupancy Separation: [MSFC 705] Min. 1-hr fire-rated construction between most other occupancies unless building has approved sprinkler system (see code for exact requirements) Corridor Construction: [MSFC 1027] Existing walls with wood lath and plaster or ½" gypsum board in good condition, 1-hr fire-rated construction or approved sprinkler system Vertical Openings: [MSFC 704] Stairways, shafts, etc. connecting 2 or more stories are enclosed Stairways, shafts, etc. connecting 3-5 stories are protected by min. 1-hr fire-rated construction or an approved fire sprinkler system Maintenance: [MSFC 703] All fire-rated construction is maintained All openings & penetrations are protected Fire Alarm Systems [MSFC 907] Alarm system provided if any unit is above the 2nd floor, any unit is more than one story below grade, OR if there are more than 16 units (Not required if there are no interior corridors and each unit has an exterior exit OR if sprinklered) Fire detectors located in furnace, laundry, mechanical & electrical rooms, trash-collection, storage & similar areas Smoke detectors located in all common areas & interior corridors Unit smoke detectors located outside bedrooms, in each bedroom & on each story Visible & audible alarms for hearing impaired Fire Sprinkler & Standpipe Systems Automatic Sprinkler System: [MSFC 903] Approved system required when units located - in basement & basement exceeds 2500 sq ft - in existing rubbish & linen chutes Standpipe Systems: [MSFC 905] Required when occupied floors are more than 50 ft above or below the lowest level of fire dept. access Page 4 of 6

Egress Window Worksheet for Windows Installed before April 11, 1983 Egress Window Worksheet for Ground Floor Windows Installed on or after March 31, 2003 Page 5 of 6

For Escape Windows Installed Above or Below the Level of Exit Discharge on or after April 11, 1983 Window Well Worksheet Page 6 of 6