Installation manual plugs and connectors QUICK-CONNECT (63 A)

Similar documents
Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Operating Instruction

Flameproof Manual Call Points

Instructions For Use ENG. LED Magnifier Lamp

3-way switching valve

FSW300 Series Flow Switch

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

EHA Hoffmann International GmbH

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

INSTRUCTIONS AND WARRANTY

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Installation and operating instructions. DK energy storage and DK energy buffer

Model: 1100 Float-Controlled Condensate Trap, PN 25

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

NEPTUN I Sole cleaning unit Art.-No.:

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Explosion Proof Combination Signal db (A) / 5 Joule

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

KETTLE WK 6330 ENGLISH

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

INSTRUCTIONS AND WARRANTY

Ceiling Fan Blade Arm Replacement

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

VADA - Rain2Main Automatic Rainwater Controller

USE AND INSTALLATION HANDBOOK

CEILING SPEAKER SYSTEMS F-2352CU2

INSTRUCTIONS AND WARRANTY

Operating instructions (translation) Stunning Device for Small Animals

Operator s manual. Battery charger C 48/ en / 03

Installation Instructions

USE AND INSTALLATION HANDBOOK

Operating instructions

INSTRUCTIONS AND WARRANTY

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

RHMP01 MULTI PURPOSE FAN

CEILING SPEAKER SYSTEMS F-2352C

Installation Instructions

MULTI - CYCLONIC VACUUM CLEANER VCC 7070

Operating Instructions UniTech Perfect

- Oscillating Table Model Fan

Universal Gripper UG 16, UG 18. Operating Instructions

MANUAL Overflow sensor NVF-104/34-PF

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

STRIP CUT PAPER SHREDDER

ELECTRIC STOVE HEATER Models: FS2213B

WET & DRY VACUUM CLEANERS

Read All Instructions Thoroughly Before Installing or Using the Disposer.

pure indoor living HIGH PERFORMANCE desk fan MODEL: BSF002, ISF004 INSTRUCTION MANUAL

INSTRUCTIONS AND WARRANTY

ELECTRIC ASH CAN Model: CVACASH500 Part No:

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Fig. 2. Fig. 1. Fig. 3. Fig. 4. Fig. 5. Fig. 7 Fig. 6. Fig. 9. Fig. 8. Fig. 10 MAX H2O

INSTALLATION GUIDE NZ AU C

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

INSTRUCTIONS AND WARRANTY

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

Operating Instructions (ENG) MODEL: 115 V UL LISTING FOR 1/2 HP MODELS ONLY. Read instructions before operating the machine J 07/05/07

CEILING SPEAKER SYSTEM

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

B INSTRUCTIONS FOR USE

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

IMPORTANT Read this manual thoroughly before using the appliance. This will ensure optimum results and maximum safety.

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

HD Kompakt Service Manual

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Installation Electric Dryers Instructions 01

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

INSTRUCTIONS AND WARRANTY

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

INSTRUCTIONS AND WARRANTY

Sandwich Press. Please read the manual fully before using the appliance and keep the manual safe for future reference.

CEILING SPEAKER SYSTEM F-122C INSTRUCTION MANUAL TABLE OF CONTENTS 7. REPAINTING THE SPEAKER SAFETY PRECAUTIONS... 2

INSTRUCTIONS AND WARRANTY MODEL NO. SFS-107. Salton Foot Spa

INSTRUCTIONS AND WARRANTY

Instruction Manual Suppository Penetration Tester. Type PM 30

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Installation & Operating Instructions

Model No: Little Devil II (inc ss)

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INSTRUCTIONS AND WARRANTY

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel. User manual. theatre spotlight

51AKB / 51 AKC OWNER S MANUAL

NRG NRG NRG NRG

FOOD WASTE DISPOSER Owner s Manual & Installation Instructions

Transcription:

EN Installation manual plugs and connectors QUICK-CONNECT (63 A) 60003217 Issue 04.2016 2016-04-01

Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended use 5 3 General safety instructions 6 4 Packaging, transport and storage 7 4.1 Packaging 7 4.2 Transport 7 4.3 Storage 7 5 Design 8 6 Assembly and disassembly 9 6.1 Connecting a cable to a 63-A plug or socket 9 6.2 Disconnecting a cable from a 63-A plug or socket 11 7 Cleaning and care 13 8 Decommissioning and disposal 14 2 / 16

1 About this manual This manual describes the assembly and disassembly of plugs and sockets of the QUICK-CONNECT system of Bals Elektrotechnik GmbH & Co. KG is an integral part of the product and must be kept in safe custody during the product service life must be read carefully and understood before use and any work. 1.1 Structure of the warnings The following picture illustrates the structure of a sample warning. 1 Hazard-specific symbol 2 Signal word 3 Type and source of the hazard 4 Possi ble consequences of failing to comply 5 Procedure for avoiding hazards 3 / 16

1.2 Symbols used General warning of a hazardous area Warning dangerously high voltage Notice 1.3 Signal words used All warnings in this manual are clearly highlighted. The following signal words are used for warnings: DANGER WARNING CAUTION NOTICE Warns of dangers which will lead to serious injuries or to death if the instructions are not followed. Warns of dangers that may lead to serious injuries or to death and/or cause considerable damage to property if the instructions are not followed. Warns of dangers that may lead to reversible injuries and/or considerable damage to property if the instructions are not followed. Warns of dangers that may lead to operational disruptions and/or considerable damage to property. Damage to the environment, too, may occur if the instructions are not followed. 4 / 16

2 Intended use The QUICK-CONNECT system is used as a screwless quick-connect system based on the cage clamp principle in electrical plugs and sockets. Plugs and sockets with QUICK-CONNECT are built for professional use. The installation and the fixed connection to the mains supply should be carried out only by trained and qualified experts. Any use going beyond the intended use is considered to be improper. The manufacturer is not liable for damages resulting from improper use. Any such risk shall be borne solely by the user. In case of unauthorised modifications or conversions, the CE conformity becomes null and void, and thus, also all claims for warranty. Modifications may lead to risks for life and limb as well as damage to the plugs and sockets or loads connected. Factory-fitted labels and markings on the plugs and sockets should not be removed, modified or blurred. Protect against foreign bodies and impact of weather The plugs and sockets meet either the protection degree IP44, IP54 or IP67 in accordance with DIN EN 60529 (VDE 0470-1), depending on the respective design. Each of these mean: Protection degree IP44: Protected against solid bodies with a diameter beyond 1.0 mm, e.g. a wire Protection against water sprayed from all sides Protection degree IP54: Protected against dust in damaging quantity Complete protection against contact Protection against water sprayed from all sides Protection degree IP67: Dust-proof Complete protection against contact Protection against temporary immersion Environment The following operating temperatures apply for the safe operation of the product: 5 / 16

Standard version Military version -25 C... +40 C -33 C... +49 C 3 General safety instructions Safe use is ensured only if this manual is followed completely. Before installation, commissioning or operation, read this manual thoroughly. The plugs and sockets must be installed, maintained and put into operation properly by qualified experts in accordance with the laws, ordinances and standards. Keep easily combustible and explosive materials away from the plugs and sockets. Handle the cables with care by always pulling at the plug and not the cable when unplugging, by preventing the cable from getting damaged mechanically, by keeping intense heat away. Never use faulty products or products with dirty, scratched or damage contacts. Keep the contacts on the product clean. Avoid tripping hazards. 6 / 16

4 4.1 4.2 4.3 Packaging, transport and storage Packaging Packaging materials are valuable raw materials and can be reused. The packaging materials should therefore be brought to an appropriate recycling facility. If this is not possible, dispose of the packaging materials according to the locally applicable regulations. Transport Check the delivery for completeness and integrity. If you identify transit damage or if the delivery is incomplete, notify your dealer or supplier immediately. Storage The product must be stored in clean condition and protected from dust and humidity. The original packaging is best suited for this purpose. 7 / 16

5 Design Based on an example, the following figure illustrates the main components of the QUICK-CONNECT plugs and sockets. 1 Front part with screwless quick-connect technique for all types of copper conductor 2 Housing 3 Cable gland with multi-grip as integrated strain relief Conductor cross-sections You can connect conductor cross-sections in the range of 6 mm 2 16 mm 2 to QUICK-CONNECT plugs and sockets (63-A designs). Cable diameter Cables with a diameter in the range of 16 mm 36 mm can be used with QUICK-CONNECT plugs and sockets (63-A designs) with multi-grip. Technical specifications The technical specifications of the plugs and sockets depend on the design. You will find them in our catalogue or on our website http://www.bals.com. 8 / 16

6 Assembly and disassembly DANGER Danger to life by electrical voltage The supply cable may carry high electrical voltage that is fatal. Pay attention to the five safety rules of electricity: 1. De-energise 2. Secure the supply from being switched on again 3. Ensure the de-energised condition 4. Connect to earth and short circuit 5. Cover or cordon off adjacent live parts 6.1 Connecting a cable to a 63-A plug or socket Proceed as follows: 1. Make sure that the cable is de-energised. 2. Open the rotary lock to separate the front part (1) from the housing (2). 3. Push the cable about 50 cm wide through the cable gland and housing. 4. Strip the cable to a length of 110 mm. 5. Remove the insulation from the individual conductors up to a length of 29 mm. Twist the multi-strand copper conductors slightly by hand. Conductor end sleeves are not necessary but may be used. 6. The terminals are open at the time of delivery. Guide the bare individual conductors into the opening near the contact slide (5) and press the contact slide (4) down in the direction of the arrow. The contact slide get latched and fixes the individual conductor. Take care to see that only the bare individual conductor (without insulation) is clamped. Pay attention to the marking of the terminals and ensure that the assignment of the individual conductors to the terminals is correct. 9 / 16

7. Check whether the individual conductors are seated tightly by pulling them lightly. If this is not the case, open the terminal and repeat the previous step. 8. Connect the housing and front part with screws until the triangular markings (7) lie over one another. 9. Fix the connection using the white latches (6) fixed on the side. The latch must be pressed in front until it gets latched audibly. 10. Next, tighten the cable gland (3). The tightening torque must lie between 7.5 Nm and 20 Nm in doing so. Please refer to the embossing on the cable gland for the exact value of the respective design. Secure the cable gland using the screw placed on the side for this purpose (8, depending on the design). 10 / 16

11. Check that the cable is seated tightly in the plug or socket. 6.2 Disconnecting a cable from a 63-A plug or socket 1. Make sure that the cable is de-energised. 2. If the cable gland (3) is secured with the help of a screw (8), loosen this screw. 3. Loosen the cable gland. 4. Disconnect the joint between the housing (2) and the front part (1). To do this, pry open the white latch (6) fixed on the side with a screwdriver. 11 / 16

5. Unscrew the housing from the front part. 6. Push the housing and the cable gland back on the cable until the connections in the front part are easily accessible. 7. Open the contact slide (4) by forcing it with a screwdriver and pull the individual conductors from the terminals. 8. Pull the cable out of the housing and out of the cable gland. 12 / 16

7 Cleaning and care It is recommended to clean the device as required. Use a dry cloth to clean the device. Use a wet cloth if the device is very dirty. DANGER Electrical voltage The device contains parts that carry hazardous voltage that may be fatal. 1. Pull out the plugs to the loads before cleaning them. 2. Make sure that the plug covers are closed. 3. Never use steam or water jet cleaners. NOTICE Damage to the plastic parts. Corrosive cleaning agents may attack or destroy the plastic parts. Use only a cloth moistened with water for cleaning. 13 / 16

Notes 8 Decommissioning and disposal Send the worn-out product for recycling or for proper disposal. Always make sure to observe and follow the local regulations. The product should not be disposed of in household waste. Environmental damage and risk to personal health are avoided with proper disposal. 14 / 16

Notes 15 / 16

Bals Elektrotechnik GmbH & Co. KG Burgweg 22 57399 Kirchhundern GERMANY Tel.: +49 27 23 / 7 71-0 Fax: +49 27 23 / 7 71-1 77 E-mail: info@bals.com Disclosure to third parties only with the consent of Bals Elektrotechnik GmbH & Co. KG. All rights reserved. Only valid at the time of printing. Update when reused.