DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Similar documents
DS7465i. Installation Instructions. Input/Output Module

Multiplex Eight Input Remote Modules

D7053. Installation Instructions Multiplex Input/Output Module

D7052. Installation Instructions Multiplex Dual Input Module

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

FMR Installation Instructions. Addressable Fire System Controller

D7044. Installation Instructions Multiplex Single Input Module

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Independent Zone Control (I.Z.C.)

Reference Guide for the DS7400Xi (Version 3+) Control/Communicator

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

DS160/161 Request To Exit PIR sensors Installation Instructions

Control/Communicator Installation Manual

EVO192 v3.0 Fire and Burglary What s New

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

IDS X-Series Installer Manual H Issued July 2013

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Remote NAC Power Supply D7038

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Model 17A00 Expansion Enclosure

Sentry 4 Zone Alarm Panel User Manual

DS7400Xi Addressable Control/ Communicator

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DS160/DS161 Request To Exit PIR sensors Installation Instructions

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

D343. Installation Instructions. Air Duct Smoke Housing

MO144. Operators Guide. Universal Timer Module

Duct smoke housings, 4-wire D341/D341P and D342/D342P

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

Solution-8248 Installation Manual ISSUE 1.16

INSTALLATION MANUAL & PROGRAM RECORD SHEET

Installation Manual Premier 412/816/832. Issue 10

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

8-zone Expansion Module

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CC408. Quick Reference Guide Solution 880

rvm4c Installation Guide Remote Video Module

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

EC-P Zone Intruder Alarm System

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Contents. Glossary

ELT-KLED EliteSuite LED Keypad Installation Manual

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Flair 500 Series Annunciators

Notification Appliance Circuit Module

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MR-2602 Two Zone Fire Alarm Control Panel

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Installation Instructions

VAP304 PRO INSTALLATION & OPERATION MANUAL

3 User s settings. 3.3 Internal clock setting

AXI LED USER MANUAL (REV. 1.0)

4-PGM Expansion Module

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

CHEAT SHEET: SPECTRA V2.1

Training Manual with Bi-directional Wireless

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

D1255RB/D1256RB/D1257RB

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

TABLE OF CONTENTS TABLE OF CONTENTS 1

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

IDS816 User Manual H Issued January 2009

Installation & Programming Guide

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Property of Monitronics Inc

2000 Series. Program Entry Guide. Control Panels

System Introduction. 1.1 Specifications S E C T I O N 1

D7024 Fire Alarm Control Panel

CC488. Quick Reference Guide Solution Ultima 880

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

F220-B6PS/M. Installation Guide. Addressable Detector Bases

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

JA-63 Profi User manual

JA-63 PROFI Alarm System MGK55402

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

GSM RFID VOICE Alarm System

Digiplex Control Panel (DGP-848) - V4.0

ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

Control/Communicator

User s Information Guide R2A

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Watchguard WGAP864 User Manual

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

KT-100 Door Controller

Installation, Operating and Maintenance Manual

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Transcription:

DS3MX-E-I EN Installation Guide 3 Mini Control Panel

DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed as a stand-alone device or connected to the DS7400Xi Alarm Control Panel Multiplex Bus for integrating individual apartment housing units into a large building monitoring system. The mini control panel has three alarm input zones, one alarm relay output, two solid state outputs, a keyswitch input, and an instant input. The mini control panel supports three user PIN codes including the master code and one door unlock PIN code. 3.2 Electrical Box Mounting The DS3MX can be mounted directly to U.S. or European size switch boxes. Figure 1: Mounting 1 2.0 Specifications Table 1: Specifications 2 12.7 cm (5 in.) Operating Voltage: 10.2 VDC to 15 VDC Operating Current: Alarm Relay: 30 ma standby 70 ma alarm C, 3 A 28 VDC/120 VAC 3 1 4 5 Solid State Output: 250 ma sink max. Operating Temperature: Response Time: -20 o C to +50 o C (-4 o F to +122 o F) 500 ms 8.3 cm (3.25 in.) EOL Resistors: Cover/Wall Tamper: Tamper 10 kω Built-in If the tamper switch is not activated within 3 seconds of powering up, then the tamper is bypassed. 1 - Single gang mounting slots 2 - Wire entrance 3 - Wall surface mounting holes 4 - Tamper 5 - Do not use as wire entrance To use with the DS7400Xi requires the DS7400Xi China ROM version 4.05 or later. 3.0 Mounting 1. Mount the DS3MX in a convenient location for operation and no higher than the shoulder height of the shortest person operating the system. 2. Remove the chassis from the base by inserting a small flathead screwdriver in the two slots at the bottom of the housing. Press up while pulling the rear chassis away from the front cover. 3.1 Wall Mount Using the base as a guide, mark the location for the three mounting holes and the wire/cable entry on the wall.

DS3MX-E-I Installation Guide 4.0 Wiring EN 3 4.0 Wiring Be sure all wiring is un-powered (de-energized) before routing or connecting to the DS3MX. 1. Route all wiring for power, zone inputs, and multiplex bus through the rear chassis wire entry hole (see Figure 1). 2. Make all necessary wire connections to the DS3MX terminals (see Figure 2). If using as a Multiplex device, see Table 4. Figure 2: DS3MX Wiring Diagram 1 +MUX- +12V- P01 P02 COM KS INS Z1 Z2 Z3 COM NO C NC 6 6 6 2 5 4 3 1 - Alarm relay 2 - DS7430 or DS7436 MUX Driver 3-12 VDC 4 - Smoke detector 5 - Alarm 6-10 K Figure 3: Address DIP Switch and Jumper Setting +MUX - +12V- P01 PO2 COM KS INS Z1 Z2 Z3 COM NO C NC O N 1 2 3 4 5 6 7 8 P1 P1 P2 P2 1 1 - Address DIP switch setting

DS3MX-E-I Installation Guide 5.0 Programming Functions EN 4 5.0 Programming Functions Table 2: Programming Function Steps Step Operation Important Note 1 Master Code [x][x][x][x] Only the master code can be used to program. The other two user codes cannot be used to program. 2 [*] for 3 seconds to enter A 1 second beep and the three zone LEDs flash quickly to indicate you entered the Programming Mode. 3 Programming address [x] or [x][x][*] You only need to input one digit for addresses 0 to 9. For addresses 10 to 23, you must enter two digits. 4 Programming value [x] or[x][x] or [x][x][x] or [x][x][x][x] 5 Repeat items 3 and 4 to program other addresses 6 Press [*] for 3 seconds to exit programmers mode. You must input four digits for addresses 0 to 2 and 22, three digits for addresses 3 to 5 and 23, and one digit for addresses 6 to 21. A 1 second beep confirms the correct input. A 1 second beep and the three zone LEDs off, indicate that you quit the Programming Mode. 1. Enter the four digit master code. The factory set default master code is [1][2][3][4]. If you forget the master code, do the following to retrieve the factory set default master code: a. Power off the DS3MX. b. Plug in jumper J1. c. Power On the DS3MX. d. Remove jumper J1. 2. Press [*] for 3 seconds. The buzzer sounds a 1 second beep and the three zone LEDs flash indicating you entered the programming mode. 3. Enter the one or two digit programming function, and press [*]. 4. Enter the new value for the function. One long beep (2 seconds) confirms the entry. To program another function, repeat Steps 3 and 4. Examples: To change the master code to 3345 after entering the Programming Mode, type: [0][*][3][3][4][5] To change the quick arm function after entering programming mode, type: [1][3][*][1] Table 3: Program Function Program Function Description Description Factory Default Allowed Program Value Range 0 Master code 1234 0001 to 9999 (0000 is not ) 1 User code 1 1000 0001 to 9999 (0000 = Disable) 2 User code 2 2000 0001 to 9999 (0000 = Disable) 3 Alarm output time 180 000 to 999 (0 second to 999 second) 4 Exit delay 090 000 to 999 (0 second to 999 second) 5 Entry delay 090 000 to 999 (0 second to 999 second) 6 1 type 2 1 = Instant delay 2 = Delay 3 = 24-hour 4 = Follower 7 1 bypass 2 1 = Bypass 2 = No bypass

DS3MX-E-I Installation Guide 6.0 Types EN 5 Table 3: Table 3: Program Function Description Factory Default Allowed Program Value Range 8 1 shunt 2 1 = shunt 2 = No zone shunt 9 2 type 4 1 = Instant 2 = Delay 3 = 24-hour 4 = Follower 10 2 bypass 2 1 = Bypass 2 = No bypass 11 2 shunt 2 1 = shunt 2 = No zone shunt 12 3 type 3 1 = Instant 2 = Delay 3 = 24-hour 4 = Follower 5 = Request to exit (REX) 13 3 bypass 2 1 = Bypass 2 = No bypass 14 3 shunt 2 1 = shunt 2 = No zone shunt 15 Alarm piezo 1 0 = Off 1 = On 16 SS output 1 1 1 = Follows armed state 2 = Follows zone alarm 17 SS output 2 1 1 = Follows fire reset 2 = Follows zone alarm 3 = Follows door unlock code 18 Quick arm 2 1 = Quick arm on, 2 = Quick arm off 19 Keyswitch input 1 1 = Allows arm only 2 = Allows arm/disarm Program Function Description Factory Default Allowed Program Value Range 20 Panic keys 0 0 = Off 1 = On (enable) 21 Relay function 0 0 = Follows alarm 1 = Follows unlock code 22 Door unlock code 23 Door unlock time 0000 0000 to 9999 (0000 = Disabled) 000 000 to 999 (0 seconds to 999 seconds) 000 = disabled For each address, you must enter the allowable program value described in Table 3. If an incorrect entry is made (not the number length, only the value), you can press [#] to clear your previous entry and re-enter it again. 5. After finishing the programming, press [*] for 3 seconds to leave the Programming Mode. One long beep and the three zones LEDs turn off indicating you left the Programming Mode. The DS3MX automatically exits the Programming Mode after 3 minutes if there is no activity (no key pressed). 6.0 Types The DS3MX supports the following zone types and functions. Instant: When the DS3MX is armed, violating an instant zone causes an immediate alarm. Delay: When the DS3MX is armed, violating this zone causes an alarm after the entry or exit delay time expires. Follower: When the DS3MX is armed and the entry zone is violated first, a follower zone experiences the same delay as the entry zone. 24-hour: Active at all times, DS3MX armed, or disarmed. Any violation causes an alarm. REX: Active at all times, armed, or disarmed. Triggering this input activates the output programmed to follow the unlock code and timer setting.

DS3MX-E-I Installation Guide 7.0 Using the DS7400Xi Alarm Control EN 6 Bypass: If a zone is programmed to allow bypass, entering a user code, pressing the [Bypass] key, a zone number, and the [On] key, bypasses the zone during this arming period. The zone bypass clears when the DS3MX is disarmed. Shunt: If a zone is programmed for zone shunt, only the first zone trigger activates the DS3MX. All additional triggers during this armed period are ignored. Shunt clears when the DS3MX is disarmed. 7.0 Using the DS7400Xi Alarm Control When using the DS3MX on the DS7400Xi Multiplex Bus, the maximum number of devices of all types is 240. DS3MX devices can be powered directly from the DS7400Xi Aux Power Terminals. However, if connecting more than twelve DS3MX devices, a separate power supply(s) is needed. Each power supply should have its 12 VDC output floating from ground to avoid a MUX bus fault and each should have its own internal battery back-up. See Figure 4 for power supply connections. Each DS3MX must have a different address using the DIP switch on the PCB. Follow standard DS7400Xi multiplex point addressing guidelines and refer to Table 4 for the proper setting. Figure 4: DS3MX with DS7400Xi System Diagram 2 3 1 4 4 1 2 3 5 6 9 7 8 11 1-12 VDC Power Supply 2-12 VDC @ 2 A supply 20 pieces DS3MX 3 - DS3MX 4 - Up to 240 DS3MX maximum 10 5 - MUX 6 - MUX + 7 - DS7400Xi 8 - DS7430/DS7436 12 9 - CMS-7000 10 - DS7412 11- RS-232 12 - Central monitoring software The DS3MX can send the following information to the DS7400Xi: arm, disarm, alarm, tamper, and trouble. Additionally, this information can be reported from the DS7400Xi to the CMS7000 multi-panel monitoring software. Refer to the CMS7000 documents for more information. See the following sections in the DS7400xi Reference Guide (Ver. 4+ [P/N: 40816]) for more information: Programming Section: Control/Communicator and Address 0419 to 0538 (requires the DS7400Xi China ROM version 4.03a or later). Programming Section if using a zone type of DS3MX = 6.

DS3MX-E-I Installation Guide EN 7 If we set the DS3MX as a single point mode device, the type is programmed as 0, the same as DS7457 Module. Only if set the DS3MX in the DS3MX expanded mode should the zone type be set to 6! Function Programming Section for more information on the 24-hour zone function. The zone function of DS3MX can only be programmed as 24-hour (value = 2), interior (value = 7), and fire zone without verification (value = 1). Other programming options are the same as standard device zone types. 8.0 Multiplex Address DIP Switch Settings Address Multiplex Address DIP Switch Setting 1 2 3 4 5 6 7 8 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 Address 1 2 3 4 5 6 7 8 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059

DS3MX-E-I Installation Guide 8.0 Multiplex Address DIP Switch Settings EN 8 Address 1 2 3 4 5 6 7 8 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090 091 092 093 094 095 096 097 098 099 Address 1 2 3 4 5 6 7 8 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139

DS3MX-E-I Installation Guide 8.0 Multiplex Address DIP Switch Settings EN 9 179 Address 1 2 3 4 5 6 7 8 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 Address 1 2 3 4 5 6 7 8 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217

DS3MX-E-I Installation Guide 8.0 Multiplex Address DIP Switch Settings EN 10 218 219 Address 1 2 3 4 5 6 7 8 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248

DS3MX-E-I Installation Guide 8.0 Multiplex Address DIP Switch Settings EN 11 Figure 5: DS3MX Using Smart Lock Wiring Diagram 1 +MUX- +12V- P01 P02 COM KS INS Z1 Z2 Z3 COM NO C NC 2 2 2 5 4 6 8 3 7 1 - Alarm relay 2-10 K 3 - Keyswitch 8 4 - Arm/disarm 5 - DS7430 or DS7436 MUX Driver 6 - Arm LED 7 - Smart Lock 8-12 VDC

Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 2003 Bosch Security Systems 49990E