LED DRIVER CATALOGUE HYTRONIK USA LLC HYTRONIK UK LTD. Priory House, Mimram Road, Hertford, Hertfordshire SG14 1NN

Tri-level Control Sensor

Built-in HF Sensor for High Bay

Tri-level Control HF Sensor

Premium Version Tri-level Dimming Control

Integrated SensorDIM LED Driver Daylight Monitoring Version

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Daylight harvest function to regulate light output for maintaining required lux level

IP65 High Bay Dual Sense Sensor

Tri-level Control HF Sensor

IP65 High Bay Dual Sense Sensor

Tri-level Control HF Sensor

False Ceiling HF Sensors

HF Motion Sensor Introduction

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Excel-EN Conventional Fire Control Panel

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit

LED Linear Design Highlights

STAND-ALONE PRODUCT GUIDE HYTRONIK INDUSTRIAL LIMITED HYTRONIK INDUSTRIAL LIMITED CHINA FACTORY PIR USA WAREHOUSE HYTRONIK UK LTD.

Data sheet. Function description. Benefits

CONTROL DEVICE SLIDETRONIC HD

Product Specifications

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

LED HIGH BAY LINEAR ECO SERIES

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

LED T8 Tube Standard T8 LED TUBE (L05G-H)

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

TROPO 15W Dimmable LED Driver

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

INSTALLATION AND OPERATION INSTRUCTIONS FOR

SAT-3 Room Temperature Controller

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Dublin airport - Dublin, Ireland

HIGH POWER LED RETROFIT MODULE

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

USER'S OPERATING INSTRUCTIONS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Loop out. Ambient daylight threshold

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Direct Dim Microwave Presence/Absence Detector

Installation Instructions

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Arc Fault Protection System D1000

D1000 Arc-fault Protection System

RE-PR3-E-27 3-Phase Panel Mount 27kW

EB-Therm 300 E / SSTL MONTERINGSANVISNING / INSTALLATION INSTRUCTIONS LEGGEANVISNING / ASSENNUSOHJEET

Danfoss gas detection units

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

BX444-Mc Gas Detector

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

SP-1000X. Panic Device Power Controller Installation Guide. Rev

FEC400 Series. Installation Manual

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Programmable Towel Radiator Manual

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

HIGH BAY APPLICATIONS

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Annunciator Unit SACO 16 D1. Product Guide

EDGE PATIO HEATER. User Manual. English

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Control box FSTronic DES-FS

DIESEL Engine Fire Pump Controllers Features

Instructions for the fan motor control system with integrated wiring terminals SILVER C

D O M E S T I C LED. Lighting C O M M E R C I A L

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

CONVENTIONAL FIRE ALARM CONTROL PANEL

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

Introduction. LHP Ultra High Input Voltage Drivers. Application:

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

MWS3A-PRM Product Guide

Product Comparison Guide

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

Analogue Dimming Microwave Presence/Absence Detector

MR-2602 Two Zone Fire Alarm Control Panel

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Operating Instructions

UNC100 Integra Manual

CU-IQ MANUAL 1. DESCRIPTION Radio Control Panel CU-IQ

FlexSQUARE Square shaped beacons

Preliminary Release. Room Temperature

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Acacia Batten. Contents. Willow Range 3 YE AR. Single. Twin. Single

TEMPERATURE CONTROLLER

ir-range 8G /03.15 Changes reserved.

Transcription:

Emergency Emergency Lighting Control Gear Combo Economy Version (2 in 1) HEM09/E / HEM09H/E Applications Suitable for LED panels - insulated terminal cover with cord restraint: Office / Commercial Lighting Classrooms Utility / Back of house (Bulkhead) Use for retrofit upgrades & new luminaire designs. Features Combined LED Driver & Emergency Sensor-DIM >3 Active PFC Design Multiple Constant current selection Over-heat Protection Short Circuit Protection Over-load Protection All with Auto-restart 5 Year, 50,000hr Warranty (driver only) } External sensor input for simple on/off sensor Provides SensorDIM automatic dimming (corridor function) always on or with timed off. Simple dip-switch set-up, no programming tools required 3W constant power, 3-hour emergency output Manual test with instantaneous fault diagnostics Flexible case design - can be optimised for building-in or used with supplied protective covers for external mounting. Output Configuration DIP Switch Settings HEM09/E HEM09H/E Dimming time Dimming level 900mA 750mA 700mA 550mA 500mA 350mA 1 2 3 1400mA 1200mA 1050mA 900mA 1 2 3 1 2 + 30min 10min 10s 3 4 100% 50% 30% 10% Hytronik Emergency Lighting Control Gear 444

Model No. HEM09/E HEM09H/E Mains voltage Mains current Mains power 220~240VAC 50/60Hz 0.2~0.15A 37W 220~240VAC 50/60Hz 0.2A - 0.15A 40W Output LED current 19W/350mA/10~54V 30W/550mA/10~54V 30W/750mA/10~40V 27W/500mA/10~54V 30W/700mA/10~43V 23W/900mA/10~25V 30W/900mA/10~33V 30W/1050mA/10~29V 25W/1200mA/10~21V 20W/1400mA/10~14V Output voltage(u-out Max.) Power factor Operation temperature Battery charge current Battery pack 54V 33V 5 5 0~+50 0~+50 100-140mA 100-140mA BPC01,BPC02, BPC10, BPC11 Battery Type / Discharge current / Max. load for 180min NiCd or NiMH 3.6V, 3AH / 1.0A / 3W@10-54V (HEM09/E); 3W@10-33V (HEM09H/E) Battery duration Charge period Max. case temp. Over-heat protection EMC standard Safety standard Certifications Dielectric strength IP grade 24 hours 80 Over-heat protection with auto-reset. EN55015, EN61547, EN61000-3-2, EN61000-3-3 EN61347-1,EN61347-2-7 Semko, CB, SAA, CE, EMC Input output: 3000VAC IP20 Dimensions and Terminals Model: HEM09 / HEM09H Unswitched N Unswitched L Switched N Switched L Dimming level selection Dimming time selection Battery connection 185 LED indicator/buzzer/test switch LED+ LED- LED current selection addtional cap for stand alone installation 4.1 23 3.9 79.2 126 129.4 140.6 445 Hytronik Emergency Lighting Control Gear

Wire Preparation Loading and In-rush Current Model HEM09/E HEM09H/E 0.75-1.5 8mm In-rush Current (Imax.) 9A 9A Pulse Time 180μs 180μs Number of Drivers Based upon 16A Circuit Breaker Solid or Stranded wire type 0.75-1.5mm 2 To make or release the wire from the terminal, use a screwdriver to push down the button. Cct Breaker Type Type B Type C HEM09/E HEM09H/E 30 30 50 50 Wiring Diagram N L N L Unswitched N Unswitched L Switched N Switched L Stand-by dimming level Dimming time selection 1.2V 1.2V 1.2V Battery LED+ LED - Green Buzzer Red Test switch LED current selection Performance Characteristics HEM09/E 8 0.85 6 4 EFFICIENCY (%) 0.8 0.75 350MA 500MA 900MA PF 2 0.88 220V 230V 240V 0.7 0.86 0.65 0.84 * Typical Efficiency vs Load * Typical Power Factor vs Load Hytronik Emergency Lighting Control Gear 446

HEM09H/E 8 0.8 7 0.7 6 5 EFFICIENCY (%) 0.6 0.5 0.4 0.3 900MA 1050MA 1200MA PF 4 3 2 1 220V 230V 240V 0.2 0.89 0.1 0.88 0 0.87 * Typical Efficiency vs Load * Typical Power Factor vs Load Manual Testing There is a test switch on HEM09/E and HEM09H/E which is designed to simply perform a test on demand for as long as the button is pressed. Routine testinig may also be carried out using a key-switch in the Un-switched supply. Neither HEM09/E or HEM09H/E carries out automatic routine testing, however it does display instantaneous diagnostic faults and reports them via the supplied bi-colour LED. Details are given below: Bi-Colour LED Diagnostics Status Buzzer beep & LED flash mode Visual indication Buzzer Battery voltage too low Battery open-circuit Battery short-circuit Battery reverse connection LED load open-circuit LED load short-circuit Battery voltage too high Red LED slowly flashes once in 3 seconds; Red LED flashes twice in 3 seconds; Red LED flashes 3 times in 3 seconds; Red LED flashes 3 times in 3 seconds; Red LED flashes 4 times in 3 seconds; Red LED rapidly flashes 5 times in 3 seconds; Red LED rapidly flashes 6 times in 3 seconds; Healthy condition Battery charge Green LED is constantly on Green LED slowly flashes once every second 447 Hytronik Emergency Lighting Control Gear

Battery Options Package code Picture Spec. Size(mm) Duration Accessories BPC01 3 cells, C type,high temperature NiMH 235x22x22 BPC02 3 cells, C type, high temperature NiMH 77x50x28 BPC10 3 cells, D type, D4000,high temperature Nicd 215x37x37.5 BPC11 3 cells, D type, D4000,high temperature Nicd 100x65x36 NiCd - Continuously rated 55 degrees for 4 years design life NiMH - Continuously rated 40 degrees for 4 years design life Charge new battery for 24hours before use. In compliance with IEC61951-1 (Nicd type), IEC61951-2 ( NiMH type). Sensor-DIM Settings (Remote Using Control External HRC-05, ON/OFF for Sensor SAM7 & HIR02) The Sensor-DIM built in to HEM09/E and HEM09H/E is designed to work with a simple on/off sensor to acheive tri-level contol. The on period during absence is controlled by the external sensor, such as Hytronik HC005S or HMW20. When the external sensor switches off, the Sensor-DIM circuit provides timed control of the dimming period and levels. The sensor switches on the light automatically when presence is detected. The period of time the light is held on is controlled by the external sensor After the external sensor switched off the light dims to stand-by level set by the dip switch on HEM09/E or HEM09H/E The light switches off automatically after the stand-by period elapses. The standby period can aslo be programmed to remain in the dimmed mode until the next occupancy ( always on mode) Hytronik Emergency Lighting Control Gear 448