HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000

Similar documents
HOT TANK INSTALLATION INSTRUCTIONS

Installation & Operating Guide

Installation & Operating Guide

DIGITAL INSTANT HOT WATER DISPENSER INSTALLATION INSTRUCTIONS

INSTANT HOT WATER DISPENSER

U.KIT1323LS. Polished Chrome Polished Nickel Satin Nickel English Bronze English Gold* Unlacquered Brass** TO HOT TANK 7 1/4"

Hot-1 Hot Water Dispenser

SCHWAN INSTALLATION GUIDE

TH100 Three in One Instant Hot Water Tap

Thermo CTP-E45T 0 Pot

Instant Hot Water Dispenser Owner s Manual

SCHWAN INSTALLATION GUIDE

A few simple steps to ensure perfect water, every time.

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

Water Distillation System Instruction Manual Nutriteam TC-501

PRE INSTALLATION PROCEDURES

Nexus FS Filtration Installation Guide. September 19, 2011

How your hot water dispenser works

PRE INSTALLATION PROCEDURES

A few simple steps to ensure perfect water, every time.

INSTALLATION & SERVICE MANUAL

Meaco 10L small home dehumidifier Instructional Manual

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

USER S MANUAL. Bottom-Load Water Cooler MODEL NO. CLBL420

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

REPLACING THE BRITA MEMO

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

SimplyClear Pressurized Filter Product Manual

A few simple steps to ensure perfect water, every time.

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

USER S MANUAL. MODEL NO. CLTL100 (White) CLTL120 (Black) Top-Load Water Cooler

multitap F-H3N1GDZL-3 F-H3N1GDZJ-3 F-H3N1GDZU-3 Installation, Care & Use ALL-IN-ONE TAP

WL380 QUICK START GUIDE

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

Encyclon Inc. Cyclonic Filtration Systems

PRO SERIES IMPORTANT SAFETY INFORMATION

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

Zen Boiling Tap Range

A few simple steps to ensure perfect water, every time.

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Meaco 20L medium home dehumidifier Instruction Manual. nergybulbs.co.uk. Meaco 20L Medium Home Dehumidifier

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

PORTABLE SMART WASHER

PORTABLE DOG BATH TOOL

Owner s Manual Guide du propriétaire Manual de Usuario. H Rev -

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

A few simple steps to ensure perfect water, every time.

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

USER MANUAL WATER DISPENSER WITH ICE MAKER

CAUTION: READ OPERATOR S MANUAL BEFORE USE Electric Kettle

6L PRESSURE COOKER. Instruction Manual. Model: PLA1424

Model No: Little Devil II (inc ss)

DIRTY WATER SUBMERSIBLE PUMP

DZ5080 US Index01 19/09/07 10:50 Page 2

Use & Care Guide. Get the most from your new Keurig brewer

Installation & Operating Instructions

DIRTY WATER SUBMERSIBLE PUMP KIT

PKWTK75. Electric Glass Kettle & Tea Brewer. Digital Hot Water Glass Kettle with Tea Filter, Adjustable Temperature Control, Stainless Steel

Water Distiller Service Manual

VADA - Rain2Main Automatic Rainwater Controller

HC1100 GN1100 H990. Steaming Hot Water Tap. Filtered 98 C water on tap. Installation, Care & Use Manual

Let s get brewing. Quick Start Guide

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

MIGHTY PRO 1/4 HP CHILLER

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

5000 Series Bottled Water System by.

SMARTBOOST IMPORTANT SAFETY INFORMATION

Please read and keep these instructions for future use

DEHUMIDIFIER INSTRUCTION MANUAL

Installation & Service Manual

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL TANKBUDDY IMPORTANT SAFETY INFORMATION

MODEL NO: MC02 BATCH NO: PR3547

30-pint Dehumidifier User Guide

One Cup. Please read and keep these instructions for future use

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

INSTALLATION & SERVICE MANUAL

Surna 25-Ton Chiller Operating & Maintenance Manual

INSTALLATION MANUAL CT-200

INSTALLATION GUIDE NZ AU C

PORTABLE AIR CONDITIONER

Clean Water Made Easy

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Important Safeguards. Save these instructions for future reference. (continued on next page)

Fundamental safety warnings

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

FAVORIT DISHWASHER USER MANUAL

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

GETTING STARTED? EASY.

User Manual. Hot Water Dispenser. Models: 177HWD15G 12/2018. Please read and keep these instructions. Indoor use only.

Refrigerator. Installation Guide. Free Standing Appliance

Installation and Operation Guide

INSTALLATION GUIDE NZ AU

Transcription:

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS Model #: 5000

INSTALLATION GUIDE BEFORE YOU BEGIN YOUR INSTALLATION: 1 2 3 4 Turn off water supply. Observe all local plumbing codes. Inspect waste and water supplies for signs of damage. Replace as necessary. DO NOT use petroleum based products on this faucet. REQUIRED TOOLS: PARTS INCLUDED: 1. Adjustable Wrench 2. Tape Measure INLET CONNECTOR 1/4 NPTF TO 1/4 TUBE OUTLET CONNECTOR 1/4 NPTF TO 5/16 TUBE WARNING! THE WATERSTONE #5000 HOT TANK IS DESIGNED FOR USE WITH A 3 LINE VENTED FAUCET ONLY. Connection to a non-vented faucet WILL DAMAGE THE TANK and void the warranty. A kinked tank outlet tube or debris in the faucet obstructing the free flow of water from the tank will subject the tank to pressures exceeding its design limits and cause the tank to leak. The Hot Tank is an open vented system appliance. When not being operated, the pressure is 0psi. Minimum operating pressure is 22psi. WARNING - USE OF AN IN-LINE INSTALLATION OF A WATER CHILLER WITH A WATERSTONE FAUCET OF ANY KIND WILL VOID OUR WARRANTY. Since 2005, Waterstone has continued to advise all of our customers against the installation of any brand of in-line water chiller unit with our faucets. Compressor style chiller units have been proven to arbitrarily exceed the standard household in line pressure ratings causing the faucet inlet connection line to burst and create the potential for water damage claims in the field. 3 LINE VENTED FAUCET Waterstone can not and will not be held liable for damages created by a use for which our products were not designed. Waterstone will only recommend the installation of a water chiller in the vented side (in place of a hot tank) with one of our Hot or Hot & Cold Filtration faucet models.

HOW A VENTED FAUCET WORKS E B F Water from the blue supply tube (A) flows through the faucet base to the ON/OFF valve (B). Water is then diverted into the red tube (C) and into the Hot Tank (D) and pressure is regulated through the built-in PRV valve. The entering water displaces hot water in the tank causing it to flow freely through the clear high temp tube (E). Hot water continues straight through the faucet and exits the spout (F). NEVER! CONNECT A #5000 HOT TANK TO A FAUCET AS SHOWN C IMPORTANT - NEVER OPERATE THE FAUCET WITH A KINKED CLEAR OUTLET TUBE OUTLET INLET D A CONNECTION TO A FAUCET OTHER THAN A 3-LINE VENTED WILL VOID WARRANTY AND CAUSE INTERNAL DAMAGE TO TANK HOT TANK INSTALLATION 1. 2. G J H K CHOOSE TANK LOCATION Turn off water supply. Find a location under your sink that has access to an electrical outlet and close enough to reach faucet tube leads without kinking. For tank to operate properly, it cannot be installed beyond reach of factory tubing. Unit must be placed vertically and level. Unit should have approximately 4-5 of space on the sides and approximately 1 from the cabinet wall in back. After faucet installation, connect 1/4 red tube (G) to connect fitting on tank inlet (H). Base of inlet will be blue. Push until secure. Connect 5/16 clear tube (J) to connect fitting on tank outlet (K). Base of outlet will be red. Push until secure.

3. 4. 5. L N M Connect 1/4 blue tube (L) to water supply (M). Turn water supply back on. DO NOT plug in unit until tank is full of water. Turn on faucet hot water until water flows freely from faucet. This means Hot Tank is full. Tank will take about 90 seconds to fill. Turn off faucet and check all connections for leaks or hose kinks. Check that installation area is dry and no water has spilled. Connect plug to the power socket. The Hot Tank s display panel (N) will light up with the ON/OFF power button illuminated. HOT TANK OPERATIONS Push power button in center to enable unit. Water temperature number will flash. Set Hot Tank to desired temperature by pushing arrow buttons around the center. Hot Tank comes with six temperature presets: 167F, 176F, 194F, 203F, 206F, and 208F. The single arrows on the top and bottom control the pre-set temperatures. Use the double arrow buttons on the left and right to adjust temperature up or down by one degree. CONTROL PANEL ON/OFF/SET BUTTON RED RINGS WATER TEMPERATURE Once the desired temperature is chosen, push the center button again to set. Hot Tank will then begin to heat up and outer red rings will pulsate. Once unit has reached set water temperature, pulse will stop and red rings will remain lit. DECREASES TEMPERATURE BY ONE DEGREE SIX PRE-SET TEMPERATURE SETTINGS: 167F, 176F, 194F, 203F, 206F, and 208F. INCREASES TEMPERATURE BY ONE DEGREE If the Hot Tank ever becomes empty of water and is turned ON, an automatic dry-burn protection sensor will shut down the unit. The display panel will then flash 208 F to indicate lack of water. To fill again, turn power off and repeat Step 4 in the installation section. Temperatures at or above 203F are the optimal settings for most installations. However, there are factors which may influence the performance of the unit such as incoming water temperature, atmospheric pressure and altitude. Should any water discharge from the spout during heat up, reduce the setting by 1 preset to compensate.

SAFETY INSTRUCTIONS This product can cause harm if installed incorrectly. Carefully read these instructions before installing and operating the Hot Tank. Failure to comply with these instructions could result in property damage, serious injury or death. Make sure all electrical wiring and water connections conform to local codes. Standard 120v electrical outlet is required under the sink. If possible, use a separate circuit dedicated to your Hot Tank. To avoid shock, serious injury or death, use a grounded power connection. DO NOT place cord, plugs or unit near or in water or other liquids. DO NOT disassemble main box or any part of the power supply. DO NOT operate the Hot Tank controls or power supply with wet hands. Check the power rating of your Hot Tank. Make sure it is suitable for the power rating of the electrical circuit it is being installed on. DO NOT operate or install the unit if it appears to have any missing parts or damaged in any way. DO NOT use outdoors or in a damp area or in a location that may fall below 32F. DO NOT use for anything other than intended domestic use. Not intended for commercial use. The Hot Tank must be installed vertically with inlet and outlet connections at the top of unit. Ensure the front of the unit is visible and the front control panel can be easily reached. DO NOT attempt to open, modify or service this electronic Hot Tank unit. Opening the unit will void the guarantee. Due to high water temperature, and for safety reasons, the Hot Tank unit is not under pressure. It is an open vented system unit. Turn off all controls before unplugging. To avoid the risk of flooding and property damage, regularly inspect the connections for any signs of leakage. DO NOT connect to a standard faucet. May cause injury, will damage the Hot Tank and void the guarantee. Keep children away from unit. DO NOT directly wash unit with water. Under sink should be ventilated and protected from direct sunshine. Humidity should stay in a range of 10% to 60%. Be sure there is no dew. MAINTENANCE AND CARE INSTRUCTIONS FLUSHING THE HOT TANK It is recommended that you flush through the system 2 or 3 times to ensure the system is fully operational. Turn on hot water until hot water within the tank has emptied. Allow the unit to reheat and then repeat. WATER DRAW BACK AND CONTAMINATION IN THE TANK You must ensure that the faucet spout is not submerged in water, especially during the dispensing of hot water when the hot water handle is closed. This will cause water draw back and contaminate the tank. POWER SAVING If the unit is not being used for long periods of time, turn off the unit to save power. SEASONAL SHUTDOWN Both the Hot Tank and Filtration Faucet must NOT be exposed to freezing temperatures. If there is a possibility of this, the system must be drained of water. Shut-off the main water supply and unplug the unit from the power socket. Allow the tank to cool for at least 1 hour. Disconnect the blue inlet and clear outlet tubes from the connectors on the tank. Lift the unit to the sink, turn upside down and drain all the water from the tank. When re-installing, follow the original installation instructions. NOTICE Like any water heater, the Waterstone Hot Tank has a limited operational life span. In order to ensure maximum performance, the unit should be flushed and inspected regularly for any water leakage or damage. This will help avoid possible property damage or personal injury. If a leak is found, replace any connectors and loose or split tubes. Place the unit in a drain pan or use a Waterstone AS-414 Safety Valve-Leak Detector for added leak protection.

TROUBLESHOOTING PROBLEM: Water and steam is spitting from the Filtration Faucet spout WHAT TO DO: The unit is boiling. Turn on the faucet s hot water and release the water. Adjust the water temperature on the display to a lower setting. PROBLEM: Water is not hot. WHAT TO DO: Turn on the power and press the ON/OFF/SET button. Adjust the water temperature or pre-set on the display to a higher setting. Press the ON/OFF/SET button again and confirm the heat up. PROBLEM: The electronic display has not been powered up WHAT TO DO: Check that the unit is plugged in and power is on. PROBLEM: Water is too hot. WHAT TO DO: Water temperature is set too high. Adjust the water temperature on the display to a lower setting. PROBLEM: Water is dripping from the Filtration Faucet spout. WHAT TO DO: The expansion chamber isn t draining the system correctly due to dispensing very small amounts of water. Dispense 2 cups of water to clear and prime the system. Avoid dispensing less than 1/2 cup of water per use. PROBLEM: The spout is blocked WHAT TO DO: Remove and clean the aerator. Bleed system to remove any air. Prime tank to allow correct operation. PROBLEM: Slow flow from the spout WHAT TO DO: Water filter may be clogged from impurities in the water. Water filter must be changed every 6 months to maintain warranty. PROBLEM: Water does not flow right away. The Hot Tank is designed for non-pressurized operation. There will be a slight delay until the near boiling water appears. If a large volume of water has been dispensed on the previous use, there may a slightly longer delay in the water appearing from spout. PROBLEM: No water flowing WHAT TO DO: Water valves may have been turned off or inlet hoses may have been twisted or blocked. Turn on all the water valves and ensure the hoses are not twisted or kinked to restrict flow. The Hot Tank is not under pressure, so there will be a slight delay in water flow after the hot water faucet handle has been turned on. This is normal and indicates that the Hot Tank is functioning properly. PERFECT FOR INSTANT HOT COFFEE, TEA, SOUP AND COOKING PRODUCT FEATURES Compatible with RO filtration systems. Digital temperature control 167F to 208F (75C to 98C). Six temperature presets: 167F, 176F, 194F, 203F, 206F, and 208F. Electronic control display panel. Insulated 1 2 gallon stainless steel tank. Maximum inlet pressure regulated for protection. Dry burn and over heat protection sensors. Heating element: 1500 watts, 120 volts. Non-pressurized bladder system. 1/4 NPTF inlet and outlet connections. Protective metal casing. Dimensions: 7-7/8 L x 8-7/8 W x 12-1/4 H. Works with any Waterstone Hot Only or Hot & Cold Filtration Faucet. Manufactured by Aqualogic. 3 year Waterstone warranty. 41180 Raintree Court Murrieta, CA 92562 1-888-304-0660 951-304-0520 www.waterstoneco.com VEN-038-HTTK