PLUMBING INSTALLATIONS

Similar documents
Frequently Asked Questions

PLUMBING REQUIREMENTS

Pipe Sizing Table. Hydraulic Load Served (fixture units)

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

Read Only Document Not For Distribution

Read Only Document Not For Distribution

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

Sanitary Drainage Systems

STACKS AND STACK VENTS

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

MATERIALS Traps TRAPS. No. IPC IRC Description

APPENDIX L ALTERNATE PLUMBING SYSTEMS

NEW WATER CONNECTION PROCEDURES FOR HOPE AND EDENVILLE TOWNSHIP RESIDENTS

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

THE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department

Level I Chapter 1 Worksheet

GARCIA GALUSKA DESOUSA Consulting Engineers

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

Building Utilities 1 Plumbing and Sanitary Systems

CHAPTER 10 TRAPS AND INTERCEPTORS

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

1 Exam Prep Plumber s Handbook Tabs and Highlights

Special Requirements For Health Care Facilities

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

APPENDIX J ILLUSTRATIONS

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

NEW WATER CONNECTION PROCEDURES

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

THE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems

Read Only Document Not For Distribution

Test Code: 8117 / Version 1

plumbing for greywater

CHAPTER VI BUILDING PLUMBING

CMHC HOME MAINTENANCE CHECKLIST

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Home Set-up and Maintenance. Maintenance

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

WARRANTY POLICY & RECOMMENDED MAINTENANCE

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Inspector Gadget Homes

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

System Name. Customer Awareness- Cross Connections and Backflow Prevention

Table B.1 Guide to degree of hazard - Point of use cross-connections (See Clauses and B.2.)

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER ANSWER SCHEDULE

2016 Plumbing Supplemental Plan Review List

Plumbing Technology/Plumber CIP Task Grid

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

CHAPTER 9 VENTS SECTION

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

TABLE OF CONTENTS. Part I Administrative... 1

Land Map Number BUILDING PERMIT # PROJECT Street Address: Owner: Street Address: City State Zip Phone. Building Contractor: Street Address:

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

PLUMBING FIXTURES CHAPTER 27

Bill de Blasio, MAYOR. build safe live safe. Rick D. Chandler P.E., COMMISSIONER

Comprehensive Inspection Agency (CIA) RESIDENTIAL & COMMERCIAL FEE SCHEDULE

Villas I at Snowden Overlook Condominium Suggested Home Maintenance Checklist July 27, 2018

Mechanical Inspection Plumbing

Home Maintenance Schedule

Chapter 4: Fixtures, Faucets & Fittings:

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

PLUMBING FIXTURES Reserved

DOMESTIC WATER PACKAGED BOOSTER PUMPS

$ Each additional variance per petition. $ All Other Zoning Districts: One variance per petition

fieldwork report contains the Functional

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

PLAN REVIEW SUBMITTAL GUIDE

Tourist Accommodations Plan Review Checklist Chapter

2009 IPC ,IMC Q &A ANDIFGC

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

The following information will explain the plumbing components and warranty coverage for the plumbing systems and fixtures in your new house.

FEATURES. Other Fed-Flush Arrangements

BUILDING DEPARTMENT FEE SCHEDULE

City of Gainesville Inspection Permitting Fees Effective July 1, 2012

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

Terry Building Inspection report summary with all items addressed or explained in red

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

THERE IS NOTHING STANDARD ABOUT OUR FIXTURES AND FINISHES.

ASME STANDARDS IN MODEL CODES

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

2009 IRC. and Fuel gas Provisions

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Matrix of changes for the National Standard Plumbing Code July 2013

2015 UPC Chapter 8 Indirect Wastes RV

Transcription:

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017

contents Permit Requirements... 3 Inspection Requirements... 4 Plumbing Code Requirements... 4 New Drain and Vent Installations... 5 Potable Water Systems... 16 Protection From Contamination By Cross Connections... 17 note: This booklet has been written to: 1) Provide homeowners with a summary of some more common plumbing regulations; and 2) Provide information on the extent to which the plumbing work must be completed before requesting an inspection. It is recommended that the applicable sections of this booklet be reviewed before commencing the project. Please note that this booklet is not intended to cover all of the plumbing regulations. Complete plumbing requirements are covered in the Manitoba Plumbing Code. 2 Every effort has been made to ensure the accuracy of information contained in this publication. However, in the event of a discrepancy between this publication and the governing City of Winnipeg By-law, the By-law will take precedence.

Permit Requirements A plumbing permit must be obtained from the City of Winnipeg Planning, Property and Development Department, Unit 31-30 Fort Street whenever: a) a plumbing system is constructed, extended, altered, renewed or repaired, and b) water supply lines in a building are replaced. A plumbing permit is not required when: a) a stoppage in the drainage system is cleared; b) a leak is repaired in a water distribution system; c) a fixture is replaced (like for like) without any change to the drainage system; or d) a replacement is made to existing faucets, or service water heaters. Plumbing permits can be issued only to: a) a person who holds a valid plumbing contractor s license from the City of Winnipeg authorizing that person to carry out business or trade in the City of Winnipeg, or b) a person who owns and resides at the single family dwelling where the work is being done. The owner must personally do the work. The permit would be issued to the owner provided the Manager of Development & Inspections is confident the work will be done competently. permit requirements A plumbing permit is not transferable. 3

permit requirements Inspection Requirements Before calling for the initial inspection, all drains, vents and water supply lines should be completely roughed in. The work must not be covered or concealed before inspection. If any part of the plumbing work is found deficient during inspection, alterations or replacement must be made as necessary. You must call for a re-inspection of corrected defects within 30 days of the original inspection. Please email ppd-housing@winnipeg.ca or call 204-986-5300 between the hours of 8:30 a.m. and 4:00 p.m. weekdays to schedule an appointment for an inspection. Before calling for a final inspection, all fixtures and equipment must be installed, operational and ready for use. If a fixture drain has been roughed-in for future use, it must be sealed with an approved plug or cap. Plumbing Code Requirements Slope of drains All drains must be installed to provide a minimum slope away from the fixture of at least 6 mm (1/4 in.) for every 300 mm (1ft) of pipe length. See FIGURE 1. FIGURE 1 - Minimum Slope of Drains 368 mm (14.5 in) 300 mm (12 in) 3000 mm (10 ft) 4

Support of drains Underground drains must be supported by a full firm base and any supports used to support the drain prior to the installation of granular material must remain in place. Above ground horizontal pipes shall be supported every 1,200 mm (4 ft). Trap arms Except for a water closet (maximum 1000 mm), the total fall from the trap to the vent must not exceed the diameter of the fixture drain. See FIGURE 2. FIGURE 2 - Fall of a Trap Arm vent pipe * See TABLE 1 trap arm Developed length A must be at least twice the size of the trap arm. Fall B must not be greater than the size of the trap arm. The maximum distance between a vent pipe and a fixture trap must not exceed the distances shown in TABLE 1. See FIGURE 3. new drain & vent installations 5

6new drain & vent installations TABLE 1 - Trap Arm Slope Pipe Size Slope Total Allowable (in.) Length 1 1 /4 1/50 1500 mm (5 ft.) 1 1 /2 1/50 1800 mm (6 ft.) 2 1/50 2400 mm (8 ft.) 3 1/50 3600 mm (12 ft.) FIGURE 3 - Lengths of Fixture Drains and Expansion Joint 3 1. Length must not exceed 1200 mm (4 ft.) 2. Minimum length is twice the diameter of the fixture drain. Maximum length is as shown in TABLE 1 3. Maximum length is 1000 mm (39 in.). 4. Maximum length is 3000 mm (10 ft.). 5. Expansion joint - size of a soil or waste stack. 6. Cleanout. 1 Expansion joints The design and installation of every piping system must, where necessary, include means to accommodate expansion and contraction of the piping system caused by temperature change and soil movement. Therefore, expansion joints must be installed at the base of every soil or waste stack. See FIGURE 3. 4 6 2 5

Approved cleanout fittings must be installed at the following locations: a) as close as practicable to the point where the building drain leaves the building; b) at the base of every soil or waste stack; c) to permit the cleaning of vents to the flood level rim of kitchen sinks, bathroom basins; and d) at every 90 degree change of direction in sink drains. See FIGURE 4. FIGURE 4 - Building Drainage System With Cleanout Fittings Bathtub C.O. Building Drain Basin C.O. W.C. Expansion Basin Line Cleanout Kitchen Sink W.C. Expansion C.O. C.O. Backwater Valve Automatic Washer C.O. W.C. Basin Floor Drain C.O. Shower new drain & vent installations Use of TY and Y fittings Tee fittings or 90 degree elbows must not be used in the horizontal portion of a drainage system. All changes of direction must be made with the use of Y and 45 degree bends. Except that a 90-degree elbow or TY fittings may be used to change the direction of horizontal drains when the direction of flow is down to the vertical. TY fittings may be used to make the connections to vent pipes. See FIGURE 5 and FIGURE 6. (Exceptions see FIGURE 7). 7

new drain & vent installations FIGURE 5 - Permitted Use of Sanitary TY Fittings - Part 1 Dry Vent Vent Sanitary T TRAP ARM Drains 8

FIGURE 6 - Permitted Use of Sanitary TY Fittings - Part 2 PERMITTED PERMITTED TRAP ARM TRAP ARM NOT PERMITTED FIGURE 7 - Permitted Use of Sanitary TY Fittings - Exceptions TRAP ARM NOT PERMITTED TRAP ARM new drain & vent installations PERMITTED PERMITTED TYPICAL INSTALLATION Fixture Fixture NOT PERMITTED PERMITTED 9

new drain & vent installations Piping in exterior walls Where piping may be exposed to freezing conditions, it must be protected. No drainage or water system can be installed in any exterior wall of a building. Vent pipes are permitted in exterior walls provided they are protected from frost.. Wet venting A soil or waste pipe may serve as a wet vent if: a) the number of water closets does not exceed two; b) water closets are installed downstream of all other fixtures; c) if two water closets are installed on the same wet vent a double TY fitting must be used for a vertical installation and a double Y fitting for a horizontal installation; d) trap arms and fixture drains connected to the wet vent cannot exceed 2 except for emergency floor drains; e) where a wet vent extends through more than one storey the discharge from any one storey above the first does not exceed 4 fixture units (see TABLE 2 on page 15), and f) a wet vent cannot be reduced in size except for an emergency floor drain portion. See FIGURES 8, 9, 10A & 10B. FIGURE 8 - One Storey Venting (Back to Back) Wet Vent Stack Vent Basin 1 1 / 4 in. Basin 1 1 / 4 in. Water Closet Shower 1 1 / 2 in. Bathtub 1 1 / 2 in. Water Closet 10 Soil - Waste Stack

FIGURE 9 - Two Storey Venting SECOND FLOOR Basin 1 1 / 4 in. FIRST FLOOR Shower 1 1 / 2 in. Automatic Washer 2in. 1 1 / 2 in. Basin 1 1 / 4 in. Water Closet new drain & vent installations 1 1 / 2 in. Water Closet Heat Duct Wet Vent 11

new drain & vent installations Backwater valves All fixtures installed below street level must be protected by a backwater valve arranged to prevent sewer back-up. The backwater valve must be installed to protect the branch drain. A backwater valve may be installed on a building drain or building sewer if listed for that location of below grade fixtures only. See FIGURES 4, 10A, & 10B. A sump pit should be installed with the back-water valve. FIGURE 10A - Typical Basement Plumbing Installation Showing Venting Method, Backwater Valve & Attachment to Cast-Iron Piping To install new rough-in plastic basement plumbing to existing cast-iron piping use plastic to cast-iron approved adaptor Building Drain 4 in. Approved Backwater Valve must be installed on branch drain to protect all new plumbing that is below grade. Branch Drain See Vent Pipe Connections Page 14 4 in. 2 in. Automatic Washer Water Closet See Vent Pipe Connections Page 14 1 1 /2 in. Shower or Bath Tub 1 1 /2 in. 1 1 /4 in. Basin Wet Vent FIGURE 10B - If the washer drain will not be installed on the wet vent with the bathroom group the size of the wet vent can be reduced to 2 2 in. Automatic Washer Separately Vented 1 1 /2 in. To install new rough-in plastic basement plumbing to existing cast-iron piping use plastic to cast-iron approved adaptor 4 in. 2 in. 1 1 /4 in. Basin Building Drain 4 in. Water Closet 2 in. 2 in. Shower or Bath Tub 12 Approved Backwater Valve must be installed on branch drain to protect all new plumbing that is below grade. Branch Drain 2 in. 1 1 /2 in. 2 in. Wet Vent

FIGURE 11 - Location of Vent Pipes Cumulative Change in Direction Max. fall of trap arm is equal to pipe size Max. developed length must not exceed distances shown in TABLE 1 Min. Developed length is two times pipe size Sanitary Tee 45 degree 90 degree Total change in direction is 135 degrees Y 45 degree Wet Vent 45 degree 45 degree Change in direction between trap and vent The cumulative change of direction between a fixture trap and a vent must not exceed 135 degrees. See FIGURE 11. Venting a) Where a vent pipe passes through the roof, it must be protected from frost closure by increasing the pipe size to at least 75 mm () in diameter immediately before penetrating the roof. b) A vent located in attic spaces must be insulated. c) Vent pipes must be installed without depressions in which moisture can collect. d) A vent pipe must extend vertically above the flood level rim of every fixture that it serves before being connected to another vent pipe. See FIGURE 12. FD new drain & vent installations 13

new drain & vent installations FIGURE 12 - Vent Pipe Connections Vent to connect above flood level rim of fixture Above Rim Vent terminated through roof to be increased to 75 mm () Vent connected to stack vent in attic space Flood Level Rim Drain pipe sizing The sizes of all fixture outlet pipes must comply with TABLE 2. See FIGURE 13. 14

Table 2 - Fixture Size Requirements FIXTURE MIN. SIZE OF FIXTURE OUTLET PIPES (inches) Bathtub (with or without shower)... 1 1 / 2 Bidet... 1 1 / 4 Clothes Washer... 2 Dishwashers (no load when connected to a garbage disposal unit or a kitchen sink trap... 1 1 / 2 Garbage disposal units - residential type... 1 1 / 2 Laundry sinks... 1 1 / 2 Lavatories (basin)... 1 1 / 4 Shower Drain... 1 1 / 2 Sink - one and two compartments with garbage disposal unit... 1 1 / 2 Water Closet... 3 FIGURE 13 - Typical Drainage & Vent Sizing 1 1 / 2 in. 1 1 / 2 in. Kitchen Sink Main Vent Basin 1 1 / 4 in. new drain & vent installations Water Closet Bathtub 1 1 / 2 in. 1 1 / 2 in. Building Sewer Cleanout 4 in. (to street) 1 1 / 2 in. 4 in. Expansion Joint Building Drain Expansion Fitting Backwater Valve 4 in. Floor Drain Building Drain Cleanout 4 in. NOTE: Every building drain must be at least 100 mm. (4 in.) in size and must be terminated by a vent at least 75 mm () in size. 15

potable water systems Potable water system All potable water systems must meet the following standards: a) Every water service pipe must be provided with a shut-off valve where the pipe enters the building. b) A water distribution system must be installed so that the system can be drained or blown out with air c) Every fixture supplied with hot and cold water controls must have the hot water control on the left and the cold water control on the right. d) Every water closet must be provided with a shut-off valve on the water supply pipe. e) Every pipe that passes through an exterior wall to supply water (i.e., lawn service) must be provided with a frost-proof hydrant with vacuum breaker or a stop-and-waste valve placed inside the building close to the outside wall or other approved location. Also, a hose bib vacuum breaker must be installed on a hose bib located outside a building or inside a garage to protect against backflow. f) All shower valves must be pressure-balance or thermostaticmixing valves conforming to CSA B125, Plumbing Fittings. 16

Protection from contamination by cross connection A hose bib vacuum breaker must be installed on every hose bib located outside a building or in a garage to isolate garden hose applications thus protecting the potable water supply from contamination. Connections to potable water systems must be designed so that non-potable water, foreign matter, foreign chemicals or substances that may render the water nonpotable cannot enter the system. A cross connection is a direct arrangement of piping which allows the potable water supply to be connected to a line that contains a contaminant. The purpose of a hose bib is to permit easy attachment of a hose for outside watering purposes. The ordinary garden hose is the most common offender as it can be easily connected to the potable water supply and used for a variety of potentially dangerous applications. A garden hose can: a) be left submerged in a swimming pool, puddle or other vessel containing non-potable water; b) have chemical sprayers attached, for spraying pesticides or herbicides; c) be lying on ground that may be contaminated with fertilizer, and garden chemicals; d) be attached to a laundry tub with the end of the hose submerged in a tub full of detergent; or e) be connected to the supply lines of bottom fed tanks, and boilers, etc. See FIGURE 14. FIGURE 14 - Back Siphonage & Backflow Prevention Hose Bib Sources of Contamination What is Back Siphonage? A reversal of normal flow in the system caused by a negative pressure (vacuum or partial vacuum) in the supply piping. Vacuum breaker protection from contamination by cross connections 17

In-Person Customer Service Hours are: Tuesday to Friday 8:30 am to 4:30 pm - All Zoning, Permits and Plan Examination services are available at Unit 31 30 Fort Street. Mondays 8:30 am to 4:30 pm are reserved for telephone inquiries and completed application drop-offs. This enables Zoning and Permits staff to process building and development applications received throughout the week. 81 Garry Entrance Elevator to Mezzanine Unit 83 Fort Street Garry Street 65 Garry Entrance Elevators to 2nd, 3rd & 4th floor 65 Garry St. 65 Garry St. Unit 15-30 Fort St. Main Floor Mall Area Unit 31-30 Fort St. 30 Fort Entrance 10 Fort Entrance Assiniboine Entrance Assiniboine Avenue 18 Bonnycastle Park www.winnipeg.ca/contactppd

For more information regarding plumbing permits, please contact: Zoning and Permits Phone: 204-986-5140 Fax: 204-986-7307 or City of Winnipeg Planning, Property and Development Department 83-30 Fort Street WINNIPEG, Manitoba R3C 4X7 www.winnipeg.ca/ppd November 2017