SECTION PLUMBING FIXTURES

Similar documents
Union County Vocational - Technical Schools Scotch Plains, New Jersey

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

A. This Section includes the following emergency plumbing fixtures:

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

A. Section Joint Sealants: Seal fixtures to walls and floors.

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DUKE UNIVERSITY CONSTRUCTION STANDARDS

A. This Section includes the following domestic water piping specialties:

PLUMBING FIXTURES CHAPTER 27

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

PLUMBING FIXTURES Reserved

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

SECTION DOMESTIC WATER PIPING SPECIALTIES

DESIGN AND CONSTRUCTION STANDARDS July 2011

University of Rochester October 17, 2008 Brooks Landing Business Center

DOMESTIC WATER PACKAGED BOOSTER PUMPS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

GENERAL PLUMBING REQUIREMENTS

Mechanical Inspection Plumbing

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

SECTION PLUMBING

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

GENERAL PLUMBING REQUIREMENTS

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Fixtures Installation

HIGH QUALITY PRICED RIGHT! Product Guide 2/19

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

8 Kitchen Gooseneck. 4 Lavatory/Shower. 8 Shower. Adjustable Garden Tub. Diverter Spring & Spool Diverter Knob Plastic Aerator Speedy Locknut

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

SECTION ELECTRIC WATER HEATERS

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

University of New Hampshire Scholars' Repository

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

CHILD DEVELOPMENT & LITERACY CENTER H17-N104-CB SGA 17002

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings

SECTION DRY-PIPE SPRINKLER SYSTEMS

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Plumbing Guidelines 2012 IBC/ANSI A

INSTALLATION INSTRUCTIONS

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

Sunset Point Building 2 BRUSHED NICKEL UPGRADE CONTEMPORARY PACKAGE. Christine Mullineaux th St. North Pinellas Park, FL

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

INSTALLATION INSTRUCTIONS

SPRINKLERS TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

MATERIALS Traps TRAPS. No. IPC IRC Description

Thermostatic shower. Mp1 SAMPLE INSTALLATION. S5573/1 (page 32) + S2261 (page 32) S2200 (page 35) + S2123 (page 35) S2218 (page 35) + S2190 (page 35)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

GENERAL PLUMBING REQUIREMENTS

SECTION WET-PIPE SPRINKLER SYSTEMS

GARCIA GALUSKA DESOUSA Consulting Engineers

CORALAIS BODYSPA BATH AND SHOWER FAUCET

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

SECTION BASIC MATERIALS AND METHODS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

Moen Commercial Products Eco-Performance Product Guide

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

Level I Chapter 1 Worksheet

SECTION (15530) - REFRIGERANT PIPING

SECTION CUSTOM FABRICATED FOODSERVICE EQUIPMENT

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

REFRIGERANT PIPING SYSTEM

PLUMBING REQUIREMENTS

FIRE SUPPRESSION SPRINKLER SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

plumbing for greywater

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

Acrylic Claw Foot Tub

SECTION ELECTRIC WATER HEATERS

PROJ. NO SECTION REFRIGERANT PIPING

B. Related Sections: The following Sections contain requirements that relate to this Section.

FIXTURES, FAUCETS AND FIXTURE FITTINGS

DIVISION 10 SPECIALTIES

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

NATURAL GAS PIPING

Transcription:

CSUEB Pioneer Heights Phase r 15410 Page 1 SECTION 15410 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes plumbing fixtures and related components. B. Related Sections include the following: 1. Division 15 Section "Plumbing Specialties" for backflow preventers and specialty fixtures not in this Section. 1.3 DEFINITIONS A. Accessible Fixture: Plumbing fixture that can be approached, entered, and used by people with disabilities. B. Fitting: Device that of plumbing fixture. include supplies and heads and tub spouts, waste pipes. Piping where indicated. 1.4 SUBMITTALS controls flow of water into or out Fittings specified in this Section stops, faucets and spouts, shower drains and tailpieces, and traps and andgeneral-duty.valves are included A. Product Data: Include selected fixture and trim, fittings, accessories, appliances, appurtenances, equipment, and supports and indicate materials and finishes, dimensions, construction details, and flowcontrol rates for each type of fixture indicated. B. Maintenance Data: For plumbing fixtures to include in maintenance manuals specified in Division 1.

Pioneer Heights Phase r. Page 2 1.5 QUALITY ASSURANCE A. Source Limitations: Obtain plumbing fixtures, faucets, and other components of each category through one source from a single manufacturer. 1. Exception: If fixtures, faucets, or other components are not available from a single manufacturer, obtain similar products from other manufacturers specified for that category. B. Regulatory Requirements: Comply with requirements in ICC Al17.1, "Accessible and Usable Buildings and Facilities"i Public Law 90-480, liarchitectural Barriers Act"i and Public Law 101-336, "Americans with Disabilities Act" i about plumbing fixtures for people with disabilities. C. Regulatory Requirements: Comply with requirements in Public Law 102-486, IIEnergy Policy Act," about water flow and consumption rates for plumbing fixtures. D. NSF Standard: Comply with NSF 61 t "Drinking Water System Components- -Health Effects," for fixture materials that will be in contact with potable water. E. Select combinations of fixtures and trim, faucets, fittings, and other components that are compatible. F. Comply with the following applicable standards and other requirements specified for plumbing fixtures: 1. Plastic Bathtubs: ANSI Z124.1. 2. Plastic Shower Enclosures: ANSI Z124.2. 3. Slip-Resistant Bathing Surfaces: ASTM F 462. 4. vitreous-china Fixtures: ASME A112.19.2M. 5. Water-Closet t Tank Trim: ASME Al12.19.5. 6. Water-Closet, Flushometer ASSE 1037. G. Comply with the following applicable standards and other requirements specified for lavatory and sink faucets: 1. Backflow Protection Devices for Faucets with Side Spray: ASME Al12.18. 3M. 2. Backflow Protection Devices for Faucets with Hose- Thread Outlet: ASME Al12.18.3M. ( \ 3. Diverter Valves for Faucets with Hose Spray: ASSE 1025.

CSUEB Pioneer Heights Phase F 15410 PLUMBING FIX11JRES Page 3 4. Faucet Hose: ASTM D 3901. 5. Faucets: ASME Al12.18.1M. 6. Hose-connection Vacuum Breakers: ASSE 1011. 7. Hose-Coupling Threads: ASME Bl.20.7. 8. Integral, Atmospheric Vacuum Breakers: ABSE 1001. 9. NSF Materials: NSF 61. 10. Pipe Threads: ASME Bl.20.1. 11. Sensor-Actuated Faucets and Electrical Devices: UL 1951. 12. Supply and Drain Fittings: ASME Al12.18.1M. H. Comply with the following applicable standards and other requirements specified for bathtub and shower faucets: 1. Backflow Protection Devices for Hand-Held Showers: ASME Al12.18. 3M. 2. Faucets: ASME Al12.18.1M. 3. Hand-Held Showers: ASSE 1014. 4. Hose-Coupling Threads: ASME Bl.20.7. 5. Manual-Control Antiscald Faucets: ASTM F 444. 6. Pipe Threads: ASME Bl.20.1. 7.Pressure-Equalizing-Control Antiscald Faucets: ASTM F 444 and ASSE 1016. 8. Sensor-Actuated Faucets and Electrical Devices: UL 1951. 9. Thermostatic Control Antiscald Faucets: ASTM F 444 and ASSE 1016. I. Comply with the following applicable standards and other requirements specified for miscellaneous fittings: 1. Atmospheric Vacuum Breakers: ASSE 1001. 2. Brass and Copper Supplies: ASME Al12.18.1M. 3. Manual-Operation Flushometers: ASSE 1037. 4. Plastic Tubular Fittings and Piping: ASTM F 409. 5. Retain ASME Al12.18.1M in subparagraph below until new ASME Al12.18.2M for drainage fittings is issued in spring or summer of 1999. Then use ASME Al12.18.2M. 6 ~ Tubular Brass Drainage Fittings and Piping: ASME Al12.18.1M. J. Comply with the following applicable standards and other requirements specified for miscellaneous components: 1. Disposers: ASSE 1008 and UL 430. 2. Floor Drains: ASME Al12.21.1M. 3. Grab Bars: ASTM F 446. 4. Hose-Coupling Threads: ASME Bl.20.7. 5. Off-Floor Fixture Supports: ASME Al12.6.1M.

Pioneer Heights Phase I Page 4 6. Pipe Threads: ASME Bl.20.1. 7. Plastic Shower Receptors: ANSI Z124.2. 8. Plastic Toilet Seats: ANSI Z124.S. 9. Supply and Drain Protective Shielding Guards: ICC Al17.1. 1.6 COORDINATION A. Coordinate roughing-in and final plumbing fixture locations, and verify that fixtures can be installed to comply with original design and referenced standards. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. For fixture descriptions in other Part 2 articles where the subparagraph titles II Products, II and II Manufacturers II introduce a list of manufacturers and their products or manufacturers only, the following requirements apply for product selection: 1. Available Products: Subject to compliance with requirements, products that may' be incorporated into the Work include, but are not limited to, the products specified in other Part 2 articles. 2. Products: Subject to compliance with requirements, provide one of the products specified in other Part 2 articles. 3. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the manufacturers specified in other Part 2 articles. 4. Manufacturers: Subject to compliance with requirements, provide products by the manufacturers specified in other Part 2 articles. 2.2 FIXTURES A. P-l Water Closet, Residental. (Flush tank, closecoupled, floor outlet): 1. Water Closet: Kohler K-3423 "Wellworth" white. 2. Seat: Round front, 12" rough in with Kohler K 4662 white plastic seat. 3. Stops and Supplies: Brasscraft OR 17 ZC with chrome plated annealed copper supplies. Supplies shall be bended with tubing bender only; bare

Pioneer Heights Phase I PageS hand bending is not acceptable. Stops shall have threaded inlet. Provide copper stub from wall with IPS adapter for connection of stops. Install stops with wall escutcheon and provide chrome-plated cover over the exposed tubing at wall. 4. Bolt caps: Color to match toilet. B. P-1A Water Closet, Residential. ADA, flush tank, close-coupled, floor outlet}: 1. Water closet: Kohler K-3427 "Highline ll white, 2. Seat: Elongated front,. 12" rough in with Kohler K-4650 white plastic seat. 3. Stops and Supplies: Brasscraft OR 17 ZC with chrome plated annealed copper supplies. Supplies shall be bended with tubing bender only; bare hand bending is not acceptable. Stops shall have threaded inlet. Provide copper stub from wall with IPS adapter for connection of stops. Install stops with wall escutcheon and provide chrome-plated cover over the exposed tubing at wall. 4. Bolt caps: Color to match toilet. C. P-2 Lavatory: 1. Lavatory: Lavatory bowl is American Standard Relient 3, 7385 counter top, rough in, install and connect.. 2. Faucet: Provide Moen "Chateau ll L4601 faucet less waste. 3. Drain: Pasco1176, 17 gage chrome plated brass commercial grid drain.. 4. Trap: 17 gage brass chrome plated P-trap, with tailpiece for cooling coil condensate drain connection if required. All traps shall be installed via a "Los Angeles Pattern" ground joint trap adapter, which shall be concealed via a chrome plated brass "box pattern" escutcheon. No slip joint connection at wall will be allowed. 5. Stops and Supplies: Brasscraft OR 17 ZC with chrome plated annealed copper supplies. Supplies shall be bended with tubing bender only; bare hand bending is not acceptable. Stops shall have threaded inlet. Provide copper stub from wall with IPS adapter for connection of stops. Install stops with wall escutcheon and provide

Pioneer Heights Phase r Page 6 chrome-plated cover over the exposed tubing at wall. D. P-2A Lavatory (Accessible/Adaptable): 1. Lavatory: Lavatory bowl is.american Standard Relient 3, 7385 counter top, rough in, insta:~:;l'and connect. 2. Faucet: Provide Moen IIChateau" L4601 faucet less waste. 3. Drain: Pasco1176, 17 gage chrome plated brass commercial grid drain. 4. ADA: Accessible Units Only. Install lavatory at the counter top of the height as required by code. Provide factory fabricated removable safety covers for drain 'and water piping under lavatory as required. p-trap and angle valve assemblies 5. shall be covered with the molded, antimicrobial TRUEBRO, INC. Lav-Guard gray under sink protective pipe cover Model #103, Color gray. Cover shall be secured with Snap-Clip flush reusable fasteners; angle stop shall have Lock-Lid locking access cover. Trap: 17-gage brass chrome plated p-trap, with tailpiece for cooling coil condensate drain con ( ) nection if required. 6. Stops and Supplies: Brasscraft OR 17 ZC with chrome plated annealed copper supplies. Supplies shall be bended with tubing bender only; bare hand bending is not acceptable. stops shall have threaded inlet. Provide copper stub from wall with IPS adapter for connection of stops. Install stops with wall escutcheon and provide chrome-plated cover over the exposed tubing at wall. E. P-3 Bath Tub: 1. Tub: Lasco Bathware 2603-SM one piece Tub/shower combination, white Lascoat polyester finished surface. 2. Bath/shower fitting: Moen L2363 IIChateau Posi Temp" with stops and TL182 Trim Kit, Moen 90410 tub drain, brass tubing with lever drain assembly. 4. Trap: Cast iron with threaded or hubless joints. {Slip joint traps may not be used}. / 5. Stops: Integral screwdriver stops.

Pioneer Heights Phase r: Page 7 F. P-4 Shower: 1. Lasco Bathware 1363-CNT one-piece shower, curtain rod and shower curtain, and Moen 2362 pressure balance mixing valve, shower head and brass strainer. G. P-4A Shower (Accessible): 1. Lasco Bathware 6030CFS one-piece tub/shower com~ bination, white Lascoat polyester finished surface with 4 grab bars on back and side walls, Tri-fold white plastic removeable seat, curtain rod and shower curtain. 2. Provide with Moen L2370 "Chateu Posi-Temp" bath/shower fitting with stops and TL182 Trim Kit, Moen 3877CP chrome plated hand held shower with slide bar and brass drain assembly. 3. Trap: Cast Iron with threaded or hubless joints. (Slip joint traps may not be used) ; 4. Stops: Integral screwdriver stops. H. p-s Kitchen Sink: 1. Sink: Elkay LRAD-2922 double compartment stainless steel self-rimming sink. 2. Faucet: Moen "Chateau ll 7467 faucet with lever handle 3. Drain: Elkay LK3S standard strainer with stainless steel conical basket.' 4. Trap: 17 gage brass chrome plated. All traps shall be connected via a "Los Angeles Pattern" ground joint trap adapter, which shall be concealed via a chrome plated brass "box pattern" escutcheon. 5. Disposal: In-Sink-Erator 333-9 garbage disposal. 6. Stops and supplies: Brasscraft OR17ZC W' F. I. P. x 3/8" compression stops with chrome plated annealed copper supply riser, with mechanical bends only where any radius offsets are required on hot or cold supply_ No hand bends allowed. I. P-SA Kitchen Sink (Accessible/Adaptable units) : 1. Sink: Elkay LRAD-2922-6S-3 double compartment stainless steel self-rimming sink.

Pioneer Heights Phase I: PageS 2. Faucet: Moen "Chateau" 7467 faucet with lever ) handle 3. Drain: Elkay LK3S standard strainer with stainless steel conical basket. 4. Trap: 17 gage brass chrome plated. All traps shall be connected via a "Los Angeles Pattern" ground joint trap adapter, which shall be concealed via a chrome plated brass "box pattern" escutcheon. 5. Disposal: In-Sink-Erator 333-9 garbage disposal. 6. stops and supplies: Brasscraft OR17ZC W' F.I.P. x 3/8" compression stops with chrome plated annealed copper supply riser, with mechanical bends only where any radius offsets are required on hot or cold supply_ No hand bends allowed. J. P-40 Mop Sink (Janitor Sink): Florestone model 24MSR 2411 x 2411 with 3" drain. Chicago model No. 897 wall mounted faucet. Hose and clamp, mop hanger, stainless steel rim guard, wedge lock seal and flat chrome strainer. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine roughing-in for water soil and for waste piping systems and supports to verify actual locations and sizes of piping connections and that locations and types of supports match those indicated, before plumbing fixture installation. Use manufacturer's roughing-in data if.roughing-in data are not indicated. B. Examine walls, floors, and cabinets for suitable conditions where fixtures are to be installed. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 FIXTURE INSTALLATION A. Assemble fixtures, trim, fittings, and other components according to manufacturers' written instructions. B. Install back-outlet, wall-hanging fixtures onto waste fitting seals and attach to supports. C. Install floor-mounting fixtures on closet flanges or other attachments to piping or building substrate. I I \.

CSUEB Pioneer Heights Phase I 15410 Page 9 D. Install wall hanging fixtures with tubular waste piping attached to supports. E. Install counter-mounting fixtures in and attached to casework. F. Install fixtures level and plumb according to manufacturers' written instructions and roughing-in drawings. G. Install water-supply piping with stop on each supply to each fixture to be connected to water distribution piping. Attach supplies to supports or substrate within pipe spaces behind fixtures. Install stops in locations where they can be easily reached for operation. 1. Exception: Use ball, gate, or globe valve if stops are not specified with fixture. Refer to Division 15 Section "Valves" for general-duty valves. H. Install trap and tubular waste piping on drain outlet of each fixture to be directly connected to sanitary drainage system. I. Install flushometer valves for accessible water closets and urinals with handle mounted on wide side of compartment. Install other actuators in locations that are easy for people with disabilities to reach. J. Install tanks for accessible, tank-type water closets 'with lever handle mounted on wide side of compartment. K. Install toilet seats on water closets. L. Install faucet-spout fittings with specified flow rates and patterns in faucet spouts if faucets are not available with required rates and patterns. Include adapters if required. M. Install faucet, flow-control fittings with specified flow rates and patterns in faucet spouts if faucets are not available with required rates and patterns. Include adapters if required. N. Install shower, flow-control fittings with specified maximum flow rates in shower arms. O. Install traps on fixture outlets.

CSUEB Pioneer Heights Phase L 15410 Page 10 1. Exception.: Omit trap on fixtures with integral traps. (. 2. Exception: Omit trap on indirect wastes, unless otherwise indicated. P. Install disposer in outlet of sinks indicated to have disposer. Install switch where indicated or in wall adjacent to sink if location is not indicated. Q. Install escutcheons at piping wall ceiling penetrations in exposed, finished locations and within cabinets and millwork. Use deep-pattern escutcheons if required to conceal protruding fittings. Refer to Division 15 Section "Basic Mechanical Materials and Methods" for escutcheons. R. Seal joints between fixtures and walls, floors, and counters using sanitary-type, one-part, mildew-resistant, silicone sealant. Match sealant color to fixture color. Refer to Division 7 Section "Joint Sealants" for sealant and installation requirements. S. Install all tubs and showers over a cementitious fill material appropriate for this application to provide continuous support for the tub and shower floors. 3.3 CONNECTIONS A. Piping installation requirements are specified in other Division 15 Sections. Drawings indicate general arrangement of piping, fittings, and specialties. B. Connect water supplies from water distribution piping to fixtures. C. Connect drain piping from fixtures to drainage piping. D. Supply and Waste Connections to Plumbing Fixtures: Connect fixtures with water supplies, stops, risers, traps, and waste piping. Use size fittings required to match fixtures. Connect to plumbing piping. E. Supply and Waste Connections to Fixtures and Equipment Specified in Other Sections: Connect fixtures and equipment with water supplies, stops, risers, traps, and waste piping specified. Use size fittings required to match fixtures and equipment. Connect to plumbing piping. F. Ground equipment. (

CSUEB Pioneer Heights Phase r 15410 Page 11 1. Tighten electrical connectors and terminals according to manufacturer I s published torque-tightening values. If manufacturer's torque values are not indicated, use those specified in UL 486A and UL 486B. 3.4 FIELD QUALITY CONTROL A. Verify that installed fixtures are categories and types specified for locations where installed. B. Check that fixtures are complete with trim, faucets, fittings, and other specified components. C. Inspect installed fixtures for damage. Replace damaged fixtures and components. D. Test installed fixtures after wat.er systems are pressurized for proper operation. Replace malfunctioning fixtures and components, then retest. Repeat procedure until units operate properly. 3.5 ADJUSTING A. Operate and adjust faucets and controls. Replace damaged and malfunctioning fixtures, fittings, and controls. B. Adjust water pressure at [faucets,] [shower valves,] [and] [flushometer valves] to produce proper flow and stream. C. Replace washers and seals of leaking and dripping faucets and stops. 3.6 CLEANING A. Clean fixtures, faucets, and other fittings with manufacturers' recommended cleaning methods and materials. Do the following: 1. Remove faucet spouts and strainers, remove sediment and debris, and reinstall strainers and spouts. 2. Remove sediment and debris from drains. 3.7 PROTECTION A. Provide protective covering for installed fixtures and fittings. B. Do 'not allow use of fixtures for temporary facilities unless approved in writing by Owner. END OF SECTION