Manual call points DM 210 LSN / SM 210 LSN

Similar documents
Manual call point SM 210 LSN RW

PRODUCT INFORMATION. GLT - Non-Automatic Fire Detector Series 120

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

BL 200 Strobes. Page F.01U A1.en/ 6/2/2004 ST / PMF1 / zab

INSTALLATION MANUAL. Operating Unit BE 500

Operating instruction

Table of Contents. 1. Mounting Tips... 2

Product Documentation

FMC 210 DM Double Action Call Points

Conventional Automatic Detectors FCP-320 FCH-320

500 Series LSN Fire Detectors (EU)

DICTATOR Hold-Open Systems for Hazardous Areas

Conventional Automatic Fire Detectors FCP-O 500 FCP-O 500-P FCP-OC 500 FCP-OC 500-P. Operation Guide

FCP 320/FCH 320 Conventional Automatic Fire Detectors

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

FMC 420RW Single Action Call Points LSN improved

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

FMC 420RW Single Action Call Points LSN improved

Synova TM product catalog.

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Remote alarm indicator and test combination MK2430

Installation and Operating Instruction

DM1131 / DM1133 / DM1134 Manual call points

Quick Selection Guide Fire Systems LSN Periphery

On the job around the clock 24/7: Fire detection systems

Automatic Fire Detectors

FCS-320-TM Series Conventional Aspirating Smoke Detectors

561-MB48. Intruder Alarm Control Panel

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

FirePro control MANUAL

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

1.7. Insulation fault evaluators EDS460/490 EDS461/491

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Interface and EOL Modules 8

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Gas Sensor Fire Detector GSME-Ex

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DC1192 Input /Output module

Compact power supply unit THZ Comfort

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

Installation and Operating Instructions

Operating Manual MS220DA

PRODUCT INFORMATION PI

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version. Product Information

Control and Indicating Equipment

QA16 Addressable System

Combi B Alarm box. Mounting instructions

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

FAS-420 Aspirating Smoke Detector LSN "improved version" FAS-420. Operation Guide

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Automatic Fire Detectors LSN improved

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Gira nurse call system Installation, start-up, operation. Gira emergency set

Fire Detection Systems Product Catalogue (Version )

FDM273 Radio manual call point Mounting

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

MANUAL Oil Level Sensor

Conventional Fire Detection

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Fireray 2000 Linear Smoke Detector

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

WSC 204 (WSC / WSC 204MH 0102 / WSC 204KP 0102 / WSC 204BZ 0102)

Service package PDAD- -SP (en) Assembly instructions d [ ]

Fire control panel detect 3004 plus and accessories

FDCL221 Line separator

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Fire control panels FC726 FC726-XA

Fire Panel BZ 500 LSN

UFM-T100H US ES CA Power Alarm Test TM

Viewguard Motion detctors PIR and DUAL detectors

Part No KEMPER Filter-Master XL

COMFORT IP: Room Control Unit Radio with Display

FDBZ290 Air sampling smoke detection kit

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operation Manual 322 KL

FP120-Z1 Power supply kit A (70 W) Technical Manual

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

MANUAL Overflow sensor NVF-104/34-PF

Flame detector. The QRA4.U is for use with the following types of burner control:

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

QAW70. Room Unit. Building Technologies. for use with heating controllers

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Operating Manual MS220KA and MSR220KA

Interface Modules for SENTRI

Annex to the Accreditation Certificate D-ZE according to DIN EN ISO/IEC 17065:2013

HYGROPHIL H process hygrometer

Technical Documentation. Local Protection System FWBLAFFS OFMS-3000 for sea-going vessels

UV - Monitor UVT 16. Use. Description

561-MB256 plus. Intruder alarm control panel. Performance features

Manual Isolating Barrier D461R1 (Revision 01)

Transcription:

PRODUCT INFORMATION Manual call points DM 210 LSN / SM 210 LSN Seite 1 601-4.998.121.358

Summary 1. Product description.............................. 3 2. Features......................................... 3 3. Planning notes................................... 4 3.1. Maximum connectable detectors............................. 4 3.2. Standards, guidelines, projecting recommendations............. 4 3.3. Use in explosion endangered areas........................... 5 3.4. Lettering variants........................................... 5 4. Order list........................................ 6 4.1. Basic scope............................................... 6 4.2. Accessories / Spare parts................................... 6 5. Construction..................................... 7 6. Functional description............................ 8 6.1. Push button call point DM 210 LSN........................... 8 6.2. Single action callpoint SM 210 LSN........................... 8 7. Installation notes................................. 8 7.1. Fixing dimensions (Internal view: housing backside)............ 9 7.2. Cable feed................................................ 9 7.3. Installation variants for fire hose boxes........................ 10 7.4. Connection................................................ 11 8. Notes for Maintenance and Service................ 12 8.1. Further Documentation...................................... 12 8.2. Disposal.................................................. 12 9. Technical data................................... 12 10. Abbreviatons.................................... 13 Seite 2 von 14

1. Product description Call points DM 210 LSN and SM 210 LSN are used for manual alarming Manual call points DM 210 LSN / SM 210 LSN are used within the Local Security Network LSN in association with fire detection central units. Manual call points SM 210 LSN RW are available in following versions for indoor and outdoor use: - Push button call point DM 210 LSN (VdS- Approval: pending), - Single action call point SM 210 LSN (VdS- Approval: pending). 2. Features DM 210 LSN: Alarm initiating by breaking the glass plate and pressing the push button. SM 210 LSN: Alarm initiating by pushing (breaking) the glass plate. Detector request routines with evaluation and multi data transmission. Detector identification and address reported at the fire panel in the event of an alarm for a faster fire localization. Alarm indication at the detector via a flashing red LED. Fixed push button after alarm triggering, at the DM 210 LSN. One design for indoor (version G) and outdoor type (version H). 3 different colors available (red, blue, yellow). Variable lettering possible with self printing foil sets. For use in extreme environmental conditions are callpoints for outdoor use (version H) equipped with a especially resistant PCB (parylene coated) and a gasket in the callpoint door. Seite 3 von 14

3. Planning notes Manual call points should be installed in easy visible and accessible places. Manual call point should be mounted in a height of approx. 1400mm ( 200mm) above the ground floor. Manual call points should be illuminated adequately by daylight or another light source (inclusively safety light if present). Manual call points should be installed in rescue- and escaping corridors (i.e. exits, passages, stairways). The distance between manual call points should be not more than 100 meters as per DIN 14 675, resp. 80 meters as per VdS. At especially endangered areas should manual call points be mounted with maximum 40 meters distance (VDE 0833 Teil 2, Pkt. 7.2.6). 3.1. Maximum connectable detectors Because of the different current consumption of LSN elements out of the LSN dataline the maximum current consumption value per LSN loop is absolute to aboden. For limit values please refer to the product information of the used fire detection central unit. 3.2. Standards, guidelines, projecting recommendations See standards, guidelines and projecting recommendations for installation place and so on. Heed the regulations of the local fire brigades. Seite 4 von 14

3.3. Use in explosion endangered areas All manual call points type DM 210 LSN and SM 210 LSN are in accordance with device category 3, aerosol group IIB and temperature class T6 of the european guideline 94/9EG (ATEX). Therewith may the callpoints be used in explosion endangered areas of zone 2! Limit values: Call points may be used only at fire panels with energy limited line output as per EN 50021. This is standard with all Bosch-Fire panels. The line voltage (U max ) may not exceed 33V! The maximum current (I max ) has to be limited to 130mA! Cable for fire detection systems : Only cables as per DIN VDE 0814 may be used. The whole cable capacity (C max ) may 1 F not exceed! The whole cable inductivity (L max ) may 0,01H not exceed! The cable type J-Y(ST)Y08, as per DIN VDE 0815 (Table 10), has a capacity of 120 F with a length of 1000meters. 3.4. Lettering variants The callpoints have a standard lettering and are adaptable to especially applications with precutted selfprinting blanco foils. This self adhesive labels will be sticked onto the front plate of the call point. Seite 5 von 14

4. Order list 4.1. Basic scope Order number LE* Denomination 4.998.063.405 ST Call point DM 210 LSN, version G, color red 4.998.063.406 ST Call point DM 210 LSN, version G, color blue 4.998.063.412 ST Call pointdm 210 LSN, version G, color yellow, 4.998.063.413 ST Call point SM 210 LSN, version G, Farbe rot 4.998.063.414 ST Call point SM 210 LSN, version G, color blue 4.998.063.407 ST Call point DM 210 LSN, version H, color red, Door with gasket, PCB is Parylene coated, for increased requirements against corrosion 4.998.063.408 ST Call point DM 210 LSN, version H, color blue, Door with gasket, PCB is Parylene coated, for increased requirements against corrosion 4.998.063.415 ST Call point SM 210 LSN, version H, color red, Door with gasket, PCB is Parylene coated, for increased requirements against corrosion 4.998.063.416 ST Call point SM 210 LSN, version H, color blue, Door with gasket, PCB is Parylene coated, for increased requirements against corrosion 4.2. Accessories / Spare parts Sachnummer LE* Bezeichnung 4.998.001.955 PAK Pre cutted lettering foils for self printing wit a standard laser printer (1 PAK = 10 sheet, a 6 lettering foils). The required printing data is on the WinPara- Disk. 3.790.170.005 ST Außer Betrieb - metal plate (out of order) Will be inserted instead of the glass plate! 3.756.630.007 ST Callpoint key (red plastics ASA) 3.789.400.000 PAK Replacement - glass plates, dimension 80 x 80 x 0,9 mm (1 PAK = 5 pieces) Seite 6 von 14

5. Construction The manual callpoint is available in different variants and consists of following components. 1 8 5 2 7 6 3 8 4 9 Pos. Denomination 1 Plastics housing 2 Door with exchangeable glass plate, covered lock (version H with gasket) 3 PCB (especially coated at version H) The PCB is snapped in at the housing ground plate. 4 Alarm LED 5 Connecting terminals 6 Triggering mechanism (snapped in at the PCB), consists of plastics frame, compression spring and push button. 7 Resetting lever (locking mechanism only at the DM 210 LSN types) 8 Cable bearings (exchangeable), for cable in and out. Cable supply is also possible at the housing backside. 9 Glass plate Seite 7 von 14

6. Functional description 6.1. Push button call point DM 210 LSN For fire alarm break the glass plate (9) and press the button (6). Thus releases the micro switch and the alarm LED (4) starts flashing. A locking mechanism fixes the button in the pressed position. Resetting follows by pulling the resetting lever (7) or closing the door(2). 2 9 2 7 6 4 6 4 9 6.2. Single action callpoint SM 210 LSN After pushing in the glass plate (9) the alarm will be released by the knob (6) and the LED (4) starts flashing. The reset follows by replacing the glass plate (9) and closing the door (2). 7. Installation notes Callpoints are designed for wall mounting. Manual call point should be mounted in a height of approx. 1400mm ( 200mm) above the ground floor. The call points are provided for over plaster and under plaster cable feed. (see next page, 7.2 Cable feed). For opening the call point has to be 35mm space near the right side. Seite 8 von 14

7.1. Fixing dimensions (Internal view: housing backside) 135 17,75 99,5 17,75 135 14,25 99,5 21,25 39,9 under plaster connecting box 60 5,2 12 3,4 ca. 35 17,55 99,9 17,55 7.2. Cable feed Over plaster cable feed Under plaster cable feed over a connecting box Seite 9 von 14

7.3. Installation variants for fire hose boxes Version 1 Installation depth min. 37 mm 135 Version 2 Installation depth 14 around ca. 2,5mm 140 Version 3 Installation depth ca. 30 2 10 147 Fire alarm Break glass 139 Press button Seite 10 von 14

7.4. Connection LSN LSN +U 0V a b a b E LSN1 LSN2 +U rt 0V sw Connection terminals power supply for other LSN- Elements i.e. LSN- Couplers a LSN1 b LSN1 a LSN2 b LSN2 E ws ge ws ge coming from the fire panel or an upstream LSN element going to the next LSN element ground connection for the sccreen wire Seite 11 von 14

8. Notes for Maintenance and Service Maintenance and service works should be undertaken regularly by skilled and trained personnel in accordance with the national legislative requirements. Faulty detectors under the warranty terms will be replaced free of charge. 8.1. Further Documentation Order number DU* Designation 3.002.218.156 ST Connection manual AHB BMZ / EMZ 3.002.218.155 ST Connection manual AHB UGM *DU = delivery unit, ST = piece For those with access authorization, on the Bosch ST ExtraNet at www.boschsecurity.com/emea/fire the current information for each product, as well as the installation instructions supplied with the device, are available for download as a PDF file. 8.2. Disposal Defective manual call points will be completely replaced and should be disposed according to the legal requirements. 9. Technical data Voltage rating (LSN): Current consumption (LSN): IP Rating (as per EN 60529): Environmental temperature: Environmental class (VdS): Dimensions (H x B x T): Housing material: 10V DC... 33V DC 0.7 ma IP 52 (indoor versions) IP 54 (outdoor version) - 10 C... +55 C (indoor versions) -25 C... +75 C (outdoor versions) II (indoor versions) III (outdoor version) 135 x 135 x 35 mm Plastic, ABS Colour: Red (RAL 3001) Blue (RAL 5005) Yellow (RAL 1003) Weight: approx. 450g Seite 12 von 14

10. Abbreviatons AHB = Anschaltehandbuch / Connection manual BMZ = Brandmeldezentrale / Fire panel BM = Brandmelder / Fire detector DIN = Deutsches Institut f. Normung / German institute for standardization EMZ = Einbruchmeldezentrale / Intrusion panel EN = Europa Norm / European standard GMZ = Gefahrenmeldeanlage / Security system KI = Kundendienst Information / Maintenance information LED = Light emittend diode LPC = Loss prevention council LSN = Local Security Network SM = Springknopfmelder / Manual call point UGM = Universelle Gefahrenmeldezentrale (Universal security system panel VDE = Verband Deutscher Elektrotechniker e.v. / Association of German Electrotechnicians Seite 13 von 14

Bosch Security Systems Robert-Koch-Str. 100 D- 85521 Ottobrunn Info - Service Telephone: +49 89 6290-1039 Fax: +49 89 6290-1039 www.boschsecurity.com info.service@de.bosch.com Page 14 of 14