652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Similar documents
661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

697C (60 HZ) Sizes 018 thru 060

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

A 14 SEER Heat Pump with R---410A Refrigerant Series

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data. Efficiency. S S Reliability

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. Efficiency

R4H4. Product Specifications

Product Data. Efficiency

R4H4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

WCH5**4. Product Specifications

N4H4. Product Specifications

Advance Product Data

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

Product Data. Efficiency

Advance Product Data

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

Product Data INDUSTRY LEADING FEATURES / BENEFITS

R 410A Ducted Horizontal Air Conditioner

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

N4A6. Product Specifications

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Advance Product Data

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Advance Product Data

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

2 shp 13 lc 1 36 t - 1 a

Installation Instructions

TECHNICAL SPECIFICATIONS

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL SPECIFICATIONS

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS STANDARD PROGRAMMABLE THERMOSTAT

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Product Data. Fig. 1 - Unit 50VR -A

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

The First Family of Indoor Weather

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL BUILDER S MODEL THERMOSTAT FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

Transcription:

DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT 652A Sizes 018 thru 060 TM The 652A split-system outdoor unit is a 12 SEER heat pump (with efficiencies up to 14.0 SEER). Homeowners will appreciate this model with Puron Refrigerant because of its efficiency, environmental soundness and Puron s availability for years to come. Another benefit of the 652A is the durability of the scroll compressor. Model 652A has received certifications from UL (U.S. and Canada), ARI, and CEC. The 652A is also approved by Energy Star for energy efficiency. AVAILABLE OPTIONS REFRIGERANT The environmentally sound refrigerant used in the 652A is Puron. This advanced refrigerant contains no chlorine which can contribute to ozone depletion in the atmosphere, so it s a smart choice for homeowners who are concerned with protecting our environment, now and for future generations. And it s a smart choice for anyone interested in high-efficiency cooling. BRYANT S EVOLUTION CONTROLS These industryleading controls, when installed with Bryant s Perfect Humidity variable-speed furnaces or fan coils, provide the homeowner with: unparalleled control of temperature, humidity, indoor air quality, and zoning unprecedented ease of use simple operation through on-screen, text-based service reminders Optional remote access through telephone or Internet is also available when combined with a remote connectivity kit. RELIABLE BUILT-IN COMPONENTS All units include a suction line accumulator to ensure that oil-rich vapor refrigerant reaches the compressor; a high-pressure switch for high-pressure protection; a discharge temperature switch for compressor overtemperature protection; a low-pressure switch for loss of charge protection; and a liquid-line filter drier to remove any moisture or foreign matter from the system. A crankcase heater is standard on the 048 and 060 sizes. COMPRESSOR PROTECTION Each scroll compressor motor is protected with internal temperature and current-sensitive overloads. For improved serviceability, all models are equipped with a compressor terminal plug. UNIT DESIGN Copper tube, enhanced aluminum fin coil is designed for strong heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan is popular for its easy removal of water, dirt, and leaves. The AeroQuiet System (AQS) consists of 4 design features to achieve ultra-low sound ratings. Aerocoustic Design featuring the Aeromax opening and wire dome top results in quieter and more efficient operation. Energy-Efficient Fan and Fan Motor provide a slower fan operation, thus reducing noise and improving efficiency. Sound Hood muffles noise from operation. Discharge Muffler minimizes low frequency sound and pressure pulsation generated by compressor discharge gas. WEATHER-PROTECTIVE CABINET The casing steel is galvanized and coated with a layer of zinc phosphate. A layer of modified polyester powder paint is then applied and baked on, providing each unit with a durable finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rustresistant, quality appearance. HEAVY DUTY INLET GRILLE The DuraGuard coil protector, made of a heavy gage coated steel wire grid with vertical 3/8-in. spacing, is designed to help protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. EASY SERVICEABILITY One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil and compressor. WIDE RANGE OF SIZES Available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. LIMITED WARRANTY Five-year limited warranty on all parts, with a 10-year limited warranty on compressor. TOTALLY ENCLOSED FAN MOTOR Means greater reliability under adverse weather conditions and dependable performance for many years. Permanent split-capacitor-type motors provide more economical operation. DEFROST CONTROL BOARD Incorporates a built-in 5- minute compressor time-delay relay, defrost relay, defrost timer, and low-voltage terminal board. The defrost control is a time/temperature initiation/termination control, which includes 4 fieldselectable (DIP switch) time periods of 30, 60, 90, and 120 minutes. This control also includes a field-selectable (DIP switch) Quiet Shift defrost mode, which can be selected if defrost noise is considered objectionable. APPLICATION VERSATILITY The 652A can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. The 652A can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES Both service valves are brass, back seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. THERMOSTATIC EXPANSION VALVE (TXV) This unit must be installed with a Puron -refrigerant approved TXV on the indoor coil. The FX4 and FV4 fan coils come factory equipped with Puron-refrigerant TXVs. When installed with these fan coils, no further change is required. For any other coil combination, the approved field accessory Puron-refrigerant TXV must be installed. For applications with fan coils such as the FC4 and FK4 which have R-22 TXVs, the R-22 TXV must be replaced with the approved field accessory Puron-refrigerant TXV. ELECTRICAL RANGE All units are offered in 208/230v single phase only. Form No. PDS 652A.18.3

DIMENSIONS AIR DISCHARGE L AIR IN 3/8" DIA. TIEDOWN KNOCKOUTS (2) PLACES C AIR DISCHARGE 2 1/2" 1 9 /16" FIELD POWER SUPPLY CONN. 7 /8" DIA. HOLE WITH 1 1/8" DIA. KNOCKOUT AND 1 3/8" DIA. KNOCKOUT B AIR IN C L E D K FIELD CONTROL SUPPLY CONN 7/8" DIA. HOLE H DIA. VAPOR LINE CONN. 3/8" DIA. LIQUID LINE CONN. F G A ACCESS PANEL 4 3 /16" 10 1 /2" M AIR DISCHARGE AIR IN J 2 15 /16" 1 1 /4" 1 3 /4" NOTES: 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55 F, (UNLESS LOW AMBIENT CONTROL IS USED) MAX. 125 F. 3. MAXIMUM OUTDOOR OPERATING AMBIENT IN HEATING MODE IS 66 F. 4. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER. 5. CENTER OF GRAVITY. A99088 DIMENSIONS (IN.) UNIT SIZE SERIES MINIMUM MOUNTING UNIT DIMENSIONS PAD DIMENSIONS A B C D E F G H J K L M Support Feet Snow Stand 018, 024 B, C 33-13/16 22-1/2 26-3/16 4-1/8 7-1/8 21-1/2 27-7/8 5/8 8-3/16 12 13-3/4 12-1/2 20 x 27 24 x 28 030 B, C 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 3/4 8-3/16 14 13-1/8 13-3/4 26 x 32 31 x 35 036 B, C 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 3/4 8-3/16 15-7/8 14-3/8 14-1/4 26 x 32 31 x 35 042 B, C 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 7/8 8-3/16 16-1/4 14 13-1/8 26 x 32 31 x 35 048 B, C 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 8-3/16 16-1/4 14-1/4 14-1/2 26 x 32 31 x 35 060 B, C 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 8-3/16 16 13-3/4 14 26 x 32 31 x 35 2

UNIT SIZE RECOMMENDED TUBE DIAMETERS LIQUID TUBE DIAMETER (IN.) 0 to 50 Ft Tube Length 0 to 50 Ft Tube Length VAPOR TUBE DIAMETER (IN.) 0 to 50 Ft Alternate 018 3/8 5/8 5/8 024 3/8 5/8 3/4 030, 036 3/8 3/4 5/8, 7/8 042, 048 3/8 7/8 3/4 060 3/8 1-1/8 7/8 NOTES: 1. Tube diameters are for lengths up to 50 ft. For tubing lengths greater than 50 ft horizontal or 20 ft vertical differential, consult the Application Guideline and Service Manual Air Conditioners and Heat Pumps Using Puron Refrigerant. 2. Refrigerant tubes and indoor coils must be evacuated to 500 microns to minimize contamination and moisture in the system. METERING DEVICE UNIT SIZE SERIES OUTDOOR PISTON INDOOR TXV* REQUIRED SUBCOOLING ( F) 018 B, C 40 KSATX0201PUR 15 024 B, C 46 KSATX0201PUR 14 030 B, C 49 KSATX0201PUR 10 036 B, C 57 KSATX0301PUR 14 042 B, C 59 KSATX0301PUR 11 048 B, C 63 KSATX0401PUR 10 060 B, C 73 KSATX0501PUR 12 * TXV must be installed when indoor coil is not equipped with a Puron approved TXV. TXV listed is for any approved coil combination. All TXVs are Puron specific bi-flow hard shutoff. UNIT SIZE SERIES STANDARD RATING A-WTD. SOUND POWER (dba) TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) 125 250 500 1000 2000 4000 8000 018-B, C 73 45.0 51.5 61.5 62.0 57.5 52.5 44.5 024-B, C 73 47.0 59.5 62.5 61.0 57.5 53.0 45.0 030-B, C 73 50.0 53.5 61.0 63.5 56.5 50.0 41.0 036-B, C 74 50.0 56.0 61.0 67.0 60.0 54.0 46.5 042-B, C 76 54.5 61.5 64.0 61.5 59.5 55.5 47.0 048-B, C 78 50.0 61.5 66.5 65.5 63.5 60.5 51.5 060-B, C 78 51.0 62.0 65.0 66.5 62.5 60.5 54.5 NOTE: Tested in accordance with ARI Standard 270-95. (Not listed with ARI). MODEL NUMBER NOMENCLATURE 652A J X 018 000 A A AA Model Number 12 SEER Split-System Heat Pump Electrical Supply J 208/230-1-60 Nominal Capacity 018 1.5 ton 042 3.5 ton 024 2 ton 048 4 ton 030 2.5 ton 060 5 ton 036 3 ton N/A Heating Size Standard Unit Series A Original Series B Second Series Common Unit U.S.A. Only 3

UNITARY HEAT PUMP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. SPECIFICATIONS UNIT SIZE-SERIES 018-B, C 024-B, C 030-B, C 036-B, C Operating Weight (Lb) 136 144 189 206 ELECTRICAL As an ENERGY STAR partner, Bryant Heating & * Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency. REGISTERED QUALITY SYSTEM *Refer to the combination ratings in the Product Data Sheet for system combinations meeting Energy Star efficiency standards. Unit Volts Hertz Phase 208-230 60 1 Operating Voltage Range* 197 253 Compressor Rated Load Amps 10.3 13.5 14.7 19.3 Compressor Locked Rotor Amps 51.0 61.0 72.5 83.0 Condenser Fan Motor Full Load Amps 0.5 0.8 1.1 1.1 Minimum Unit Ampacity for Wire Sizing 13.4 17.7 19.5 25.2 Minimum Wire Size (60 C Copper) (AWG) 14 14 14 12 Minimum Wire Size (75 C Copper) (AWG) 14 14 14 12 Maximum Wire Length (60 C) (Ft) 59 44 39 50 Maximum Wire Length (75 C) (Ft) 56 42 37 48 Maximum Branch Circuit Fuse Size** 20 25 30 35 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland Compressor Type Scroll Refrigerant Type Puron Refrigerant Amount (Lb) 5.5 5.25 5.375 8.375 OUTDOOR COIL & FAN Coil Face Area (Sq Ft) 10.83 10.83 12.12 18.18 Fins per In. Rows Circuits 25 1 2 25 1 2 25 1 2 25 1 4 Fan Motor HP & RPM 1/12 and 1100 1/8 and 1100 1/5 and 825 1/5 and 825 Rated Airflow (CFM) 1600 1900 2400 2800 OPTIONAL EQUIPMENT Support Feet 4 In. (4) KSASF0101AAA Snow Stand 18 In. KHASS0206MPK Time Delay Relay KAATD0101TDR Outdoor Thermostat KHAOT0301FST Secondary Outdoor Thermostat KHAOT0201SEC Crankcase Heater KAACH1201AAA Start Assist Capacitor/Relay Type KSAHS1501AAA Start Assist PTC Type KAACS0201PTC Bi-Flow TXV (Hard Shutoff) KSATX0201PUR KSATX0301PUR Pressure Guard Kit KHAPGO101PGS KHAPG0201PGS Filter Drier (Suction Line) KH45LG140 (RCD) Evaporator Freeze Thermostat KAAFT0101AAA Isolation Relay KHAIR0101AAA Liquid-Line Solenoid Valve (LSV) KHALS0401LLS Low-Ambient Pressure Switch Kit KSALA0301410 MotorMaster Low-Ambient Controller*** KSALA0401AAA Ball-Bearing Fan Motor HC34GE232 (RCD) HC38GE231 (RCD) Coastal Filter KAACF0801MED Evolution Controls See chart. See notes on page 5. 4

SPECIFICATIONS Continued UNIT SIZE-SERIES 042-B, C 048-B, C 060-B, C Operating Weight (Lb) 213 258 287 ELECTRICAL Unit Volts Hertz Phase 208 230 60 1 Operating Voltage Range* 197 253 Compressor Rated Load Amps 21.1 20.5 27.6 Compressor Locked Rotor Amps 104.0 109.0 158.0 Condenser Fan Motor Full Load Amps 1.1 1.4 1.4 Minimum Unit Ampacity for Wire Sizing 27.5 27.0 35.9 Minimum Wire Size (60 C Copper) (AWG) 10 10 8 Minimum Wire Size (75 C Copper) (AWG) 10 10 8 Maximum Wire Length (60 C) (Ft) 71 74 86 Maximum Wire Length (75 C) (Ft) 68 70 82 Maximum Branch Circuit Fuse Size** 40 40 60 COMPRESSOR & REFRIGERANT Compressor Manufacturer Copeland Compressor Type Scroll Refrigerant Type Puron Refrigerant Amount (Lb) 8.63 13.25 13.25 OUTDOOR COIL & FAN Coil Face Area (Sq Ft) 12.12 18.18 18.18 Fins per In. Rows Circuits 20 2 3 20 2 4 20 2 5 Fan Motor HP & RPM 1/5 and 825 1/4 and 1100 1/4 and 1100 Rated Airflow (CFM) 2800 3300 3300 OPTIONAL EQUIPMENT Support Feet 4 In. (4) KSASF0101AAA Snow Stand 18 In. KHASS0206MPK Time Delay Relay KAATD0101TDR Outdoor Thermostat KHAOT0301FST Secondary Outdoor Thermostat KHAOT0201SEC Crankcase Heater KAACH1201AAA Standard Start Assist Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA Start Assist PTC Type KAACS0201PTC Bi-Flow TXV (Hard Shutoff) KSATX0301PUR KSATX0401PUR KSATX0501PUR Pressure Guard Kit KHAPG0101PGS KHAPG0201PGS Filter Drier (Suction Line) KH45LG141 (RCD) Evaporator Freeze Thermostat KAAFT0101AAA Isolation Relay KHAIR0101AAA Liquid-Line Solenoid Valve (LSV) KHALS0401LLS Low-Ambient Pressure Switch Kit KSALA0301410 MotorMaster Low-Ambient Controller*** KSALA0401AAA Ball-Bearing Fan Motor HC38GE231 (RCD) HC40GE232 (RCD) Coastal Filter KAACF0801MED Evolution Controls See chart. * Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. If other than uncoated (non-plated), 60 C or 75 C (140 or 167 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent. ** Time-delay fuse or circuit breaker. The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, refer to the Long-Line section of the Application Guideline and Service Manual Air Conditioners and Heat Pumps Using Puron Refrigerant. *** Ball-bearing fan motor must be installed. Use with low-ambient pressure switch. NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. 5

THERMOSTATS AND ACCESSORIES Thermidistat Control Non-Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) Thermostat Auto Changeover, 7-Day Programmable, F/ C, Dual Fuel, Includes Outdoor Sensor (TSTATXXSEN01-B) Thermostat Auto Changeover, 7-Day Programmable, F/ C, 2-Stage Heat/1-Stage Cool Thermostat Auto Changeover, Non-Programmable, F/ C, 2-Stage Heat/1-Stage Cool Standard Programmable Thermostat Manual Changeover, 5-2 Day Programmable, F/ C, 1-Stage Heat/1-Stage Cool Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 2-Stage Heat/1-Stage Cool, Heat Pump Outdoor Air Temperature Sensor Backplate for Non-Programmable Thermostat Backplate for Programmable Thermostat and Thermidistat Control Backplate for Builder s Thermostat Backplate for Standard Programmable Thermostat Thermostat Conversion Kit (4 to 5 Wire) 10 Pack * Do not use in zoning heat pump applications. This plate is designed to cover surrounding wall area located behind thermostat. Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. ** Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat. ACCESSORY SYSTXBBUID01 SYSTXBBUIZ01 SYSTXBB4ZC01 SYSTXBBSMS01 SYSTXBBRRS01 SYSTXBBSAM01 SYSTXBBNIM01*** SYSTXXXBPU01 EVOLUTION * CONTROLS * When applied with Bryant s Perfect Humidity series 355, 315 and FE Models. *** Must be installed in Dual-Fuel Evolution system applications. TSTATBBPRH01-B* TSTATBBPDF01-B* TSTATBBPHP01-B TSTATBBNHP01-B TSTATBBSHP01 TSTATBBBHP01* TSTATXXSEN01-B** TSTATXXNBP01 TSTATXXPBP01 TSTATXXBBP01 TSTATXXSBP01 TSTATXXCNV10 DESCRIPTION Evolution Control Deluxe 7-Day Programmable (Wall-mounted system control.) Z Evolution Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a multi-zone system.) O Evolution 4-Zone Damper Control Module (Wall-mounted control for a four-zone system.) N I Evolution Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an N individual zone.) G Evolution Remote Room Sensor (Monitors temperature in an individual zone.) Evolution System Access Module (Hardware for wireless access and control via phone or internet.) Evolution Network Interface Module (Connects Heat Recovery or Energy Recovery Ventilators or older twospeed outdoor models to system.) Back Plate for Evolution Control (Decorative wall plate.) ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Compressor Start Assist Capacitor and Relay Yes Yes Puron Low-Ambient Pressure Switch Yes No Wind Baffle See Low-Ambient Pressure Switch Instructions No Support Feet Recommended No Puron Hard Shutoff TXV Yes Yes Puron Liquid-Line Solenoid Valve for Heating *For tubing line sets between 50 and 175 ft and/or 20 ft elevation difference between indoor and outdoor units, refer to the Application Guideline and Service Manual Air Conditioners and Heat Pumps Using Puron Refrigerant. Required for all applications. No See Long-Line Application Guideline 6

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster Low-Ambient Controller is installed. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 3. Compressor Start Assist Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Note: Heat pumps with Puron-refrigerant and a reciprocating compressor have capacitor and relay factory supplied. Usage Guideline: Required for single-phase reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 4. Compressor Start Assist PTC Type Solid state electrical device which gives a "soft" boost to the reciprocating compressor at each start-up. Usage Guideline: Suggested in installations with marginal power supply. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Note: Some heat pumps are factory supplied with a crankcase heater. See accessory list for units that come standard with a crankcase heater. For units that do not, use the guideline below. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 7. Isolation Relay An SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Usage Guideline: Required in all heat pumps where low ambient kit has been added. 8. Liquid-Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Application Guideline. 9. Low-Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F ( 17.8 C) when properly installed. Usage Guideline: A Low-Ambient Pressure Switch or MotorMaster Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). 10. MotorMaster Low-Ambient Controller A fan-speed control device activated by a temperature sensor designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F ( 28.9 C), it maintains condensing temperature at 100 F ± 10 F (37.8 C ± 12 C). Usage Guideline: A MotorMaster Low-Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). Suggested for all commercial applications 11. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Bryant thermostats listed in this publication. 12. Outdoor Thermostat An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point. Usage Guideline: Electric supplemental heat applications in non-variable speed indoor units when electric heat staging is desired. 13. Pressure Guard Kit A pressure switch kit that cycles the outdoor fan to limit the heating head pressure below a pre-determined pressure setting. Usage Guideline: Some local codes may require limiting the heating head pressure in the vapor line in some applications. 14. Secondary Outdoor Thermostat An SPDT temperature-actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the secondstage set point. Usage Guideline: Outdoor thermostat applications where electric heater is capable of 3-stage operation. 7

ACCESSORY DESCRIPTION AND USAGE (continued) 15. Snow Stand Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base. Usage Guideline: Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 16. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Usage Guideline: Suggested when unit is installed closer than 15 ft to quiet areas bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft apart. 17. Support Feet Four stick-on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 18. Thermostatic Expansion Valve (TXV) Bi-Flow A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Required in all heat pump applications designed with Puron refrigerant. 19. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 8

UNIT SIZE- SERIES INDOOR UNIT CFM TC COMBINATION RATINGS* Seasonal Efficiency SEER Factory- Supplied Enhancement Standard Rating 9 ARI STANDARD RATINGS* Field-Supplied Accessory Puron TXV High-Temp Heating Low-Temp Puron TXV & TDR** EER TC COP TC COP *FX4BNF018 17,000 TDR&TXV 12.00 10.20 17,200 3.20 10,400 2.10 7.3 CC5A/CD5AA024 17,000 NONE 11.60 10.00 16,500 2.98 10,300 2.02 7.0 CC5A/CD5AW024 16,800 NONE 11.70 10.00 16,000 2.90 10,300 2.02 6.8 CE3AA024 16,800 NONE 11.80 10.05 16,600 3.44 9,900 2.26 6.8 CF5AA024 17,000 NONE 11.80 10.05 16,300 3.02 10,400 2.06 7.0 CK3BA024 17,000 NONE 12.00 10.10 17,200 3.22 10,500 2.10 7.4 CK5A/CK5BA024 17,000 NONE 12.00 10.10 17,100 3.22 10,500 2.10 7.4 CK5A/CK5BW024 17,000 NONE 12.00 10.10 17,100 3.22 10,500 2.10 7.4 CK5PA024 17,000 TXV 12.00 10.10 17,100 3.22 10,500 2.10 7.4 CK5PW024 17,000 TXV 12.00 10.10 17,100 3.22 10,500 2.10 7.4 F(A,B)4BN(F,C)024 17,000 TDR 12.00 10.20 17,100 3.18 10,400 2.10 7.3 FC4CNF024 17,000 TDR&TXV 12.00 10.20 17,000 3.18 10,400 2.10 7.3 FE4ANF002 17,400 TDR&TXV 13.50 11.65 16,800 3.06 10,400 2.06 7.2 FF1DNA024 17,000 TDR 11.80 10.05 17,100 3.16 10,400 2.08 7.2 FG3AAA024 16,600 NONE 11.50 9.90 17,000 2.98 10,300 2.02 6.8 FK4DNF002 17,400 TDR&TXV 13.50 11.65 16,800 3.06 10,400 2.06 7.2 FV4BNF002 17,400 TDR&TXV 13.50 11.65 16,800 3.06 10,400 2.06 7.2 018-B, C COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CK3BA024 17,400 TDR 13.00 11.25 16,800 3.34 10,000 2.24 7.5 CK5A/CK5BA024 17,200 TDR 13.20 11.25 16,800 3.34 10,000 2.24 7.5 CK5A/CK5BW024 17,200 TDR 13.20 11.25 16,800 3.34 10,000 2.24 7.5 CK5PA024 17,200 TDR&TXV 13.20 11.25 16,800 3.34 10,000 2.24 7.5 CK5PW024 17,200 TDR&TXV 13.20 11.25 16,800 3.34 10,000 2.24 7.5 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA024 17,200 TDR 13.00 11.10 15,900 3.10 10,000 2.16 7.3 CC5A/CD5AW024 17,200 TDR 13.00 11.10 16,200 3.18 9,900 2.16 7.4 CE3AA024 17,200 TDR 13.00 11.10 16,500 3.24 10,000 2.18 7.5 CK3BA024 17,400 TDR 13.00 11.20 16,800 3.44 10,100 2.24 7.8 CK5A/CK5BA024 17,400 TDR 13.00 11.20 16,800 3.44 10,100 2.24 7.8 CK5A/CK5BW024 17,400 TDR 13.00 11.20 16,800 3.44 10,100 2.24 7.8 CK5PA024 17,400 TDR&TXV 13.00 11.20 16,800 3.44 10,100 2.24 7.8 CK5PW024 17,400 TDR&TXV 13.00 11.20 16,800 3.44 10,100 2.24 7.8 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,200 TDR 13.00 11.15 16,400 3.22 9,900 2.16 7.5 CE3AA024 17,200 TDR 13.00 11.05 16,500 3.24 10,000 2.18 7.5 *FX4BNF030 24,400 TDR&TXV 12.00 10.30 24,600 3.28 15,500 2.24 7.4 CC5A/CD5AA036 24,400 NONE 12.00 10.20 23,000 3.12 15,600 2.22 7.2 CC5A/CD5AW036 24,400 NONE 12.00 10.20 23,000 3.12 15,500 2.22 7.2 CE3AA036 24,200 NONE 12.00 10.15 24,000 3.10 15,400 2.16 7.0 CF5AA036 24,200 NONE 11.70 10.20 23,200 3.14 15,500 2.20 7.2 CK3BA036 24,400 NONE 12.00 10.25 24,000 3.26 15,600 2.24 7.4 CK5A/CK5BA036 24,400 NONE 12.00 10.25 24,000 3.26 15,600 2.24 7.4 CK5A/CK5BT036 24,400 NONE 12.00 10.25 24,000 3.26 15,600 2.24 7.4 CK5A/CK5BW036 24,400 NONE 12.00 10.25 24,000 3.26 15,600 2.24 7.4 CK5PA036 24,400 TXV 12.00 10.25 24,000 3.26 15,600 2.24 7.4 CK5PT036 24,400 TXV 12.00 10.25 24,000 3.26 15,600 2.24 7.4 CK5PW036 24,400 TXV 12.00 10.25 24,000 3.26 15,600 2.24 7.4 F(A,B)4BN(F,C)030 24,000 TDR 11.70 10.15 24,400 3.16 15,400 2.20 7.2 FC4CNF030 24,000 TDR&TXV 11.70 10.15 24,400 3.16 15,400 2.20 7.2 FE4ANF002 24,400 TDR&TXV 13.00 11.10 24,000 3.40 14,900 2.32 7.6 FE4ANF003 24,400 TDR&TXV 13.50 11.35 24,000 3.42 14,800 2.34 7.6 FG3AAA036 24,000 NONE 11.50 10.10 24,200 3.16 15,500 2.18 7.2 FK4DNF001 24,400 TDR&TXV 13.00 11.10 23,800 3.26 14,900 2.28 7.4 024-B. C FK4DNF002 24,400 TDR&TXV 13.00 11.10 23,800 3.42 14,900 2.32 7.5 FK4DNF003 24,400 TDR&TXV 13.50 11.35 23,800 3.42 14,800 2.34 7.5 FV4BNF002 24,400 TDR&TXV 13.00 11.10 24,000 3.40 14,900 2.32 7.6 FV4BNF003 24,400 TDR&TXV 13.50 11.35 24,000 3.42 14,800 2.34 7.6 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CE3AA036 24,000 TDR 12.70 11.10 23,800 3.16 14,800 2.26 7.2 CK3BA036 24,800 TDR 13.00 11.30 23,600 3.30 14,800 2.34 7.4 CK5A/CK5BA036 24,400 TDR 13.00 11.30 23,600 3.30 14,800 2.34 7.4 CK5A/CK5BT036 24,400 TDR 13.00 11.30 23,600 3.30 14,800 2.34 7.4 CK5PA036 24,400 TDR&TXV 13.00 11.30 23,600 3.30 14,800 2.34 7.4 CK5PT036 24,400 TDR&TXV 13.00 11.30 23,600 3.30 14,800 2.34 7.4 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 24,800 TDR 13.00 11.10 24,000 3.40 15,000 2.32 7.6 CK3BA036 24,800 TDR 13.00 11.10 24,000 3.40 15,000 2.32 7.5 CK5A/CK5BA036 24,800 TDR 13.00 11.10 24,000 3.40 15,000 2.32 7.6 CK5A/CK5BE042 22,800 TDR 12.50 11.05 23,200 3.18 14,600 2.22 7.2 CK5A/CK5BW036 24,800 TDR 13.00 11.10 24,000 3.40 15,000 2.32 7.6 CK5PA036 24,800 TDR&TXV 13.00 11.10 24,000 3.40 15,000 2.32 7.6 CK5PW036 24,800 TDR&TXV 13.00 11.10 24,000 3.40 15,000 2.32 7.6 See notes on page 15. HSPF

UNIT SIZE- SERIES 024-B, C 030-B, C 036-B, C See notes on page 15. INDOOR UNIT CFM TC COMBINATION RATINGS* Continued, Seasonal Efficiency SEER Factory- Supplied Enhancement Standard Rating ARI STANDARD RATINGS* Field-Supplied Accessory Puron TXV High-Temp Heating Low-Temp Puron TXV & TDR** EER TC COP TC COP COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW036 25,000 TDR 13.00 11.30 24,000 3.44 14,900 2.36 7.6 CK5A/CK5BW036 25,000 TDR 13.00 11.30 24,000 3.44 14,900 2.36 7.6 CK5PW036 25,000 TDR&TXV 13.00 11.30 24,000 3.44 14,900 2.36 7.6 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW036 25,000 TDR 12.70 10.80 24,200 3.44 15,400 2.32 7.6 CK5A/CK5BW036 25,000 TDR 12.70 10.80 24,600 3.44 15,400 2.32 7.6 CK5PW036 25,000 TDR&TXV 12.70 10.80 24,600 3.44 15,400 2.32 7.6 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW036 25,000 TDR 13.00 11.20 24,600 3.52 15,200 2.38 7.7 CK5A/CK5BW036 25,000 TDR 13.00 11.20 24,600 3.52 15,200 2.38 7.6 CK5PW036 25,000 TDR&TXV 13.00 11.20 24,600 3.52 15,200 2.38 7.6 *FX4BNF030 28,400 TDR&TXV 12.30 10.75 29,000 3.40 18,500 2.40 7.8 CC5A/CD5AA036 28,400 NONE 12.20 10.70 29,000 3.34 18,500 2.38 7.7 CC5A/CD5AW036 28,400 NONE 12.20 10.70 29,000 3.34 18,500 2.38 7.7 CE3AA036 28,000 NONE 12.20 10.60 28,800 3.28 18,500 2.34 7.6 CF5AA036 28,400 NONE 12.20 10.65 29,000 3.32 18,500 2.36 7.6 CK3BA036 28,400 NONE 12.20 10.75 29,000 3.40 18,600 2.40 7.8 CK5A/CK5BA036 28,400 NONE 12.20 10.75 29,000 3.40 18,600 2.40 7.8 CK5A/CK5BT036 28,400 NONE 12.20 10.75 29,000 3.40 18,600 2.40 7.8 CK5A/CK5BW036 28,400 NONE 12.20 10.75 29,000 3.40 18,600 2.40 7.8 CK5PA036 28,400 TXV 12.20 10.75 29,000 3.40 18,600 2.40 7.8 CK5PT036 28,400 TXV 12.20 10.75 29,000 3.40 18,600 2.40 7.8 CK5PW036 28,400 TXV 12.20 10.75 29,000 3.40 18,600 2.40 7.8 F(A,B)4BN(F,C)036 28,000 TDR 11.80 10.35 29,200 3.20 18,700 2.32 7.6 FC4CNF036 28,000 TDR&TXV 11.80 10.35 29,200 3.28 18,700 2.32 7.6 FE4ANF002 28,400 TDR&TXV 13.50 12.15 28,000 3.64 17,600 2.56 8.2 FE4ANF003 28,400 TDR&TXV 13.80 12.00 28,000 3.54 17,600 2.52 8.1 FG3AAA036 28,000 NONE 12.00 10.55 28,800 3.26 18,500 2.34 7.6 FK4DNF002 28,400 TDR&TXV 13.50 12.15 28,000 3.64 17,600 2.56 8.2 FK4DNF003 28,400 TDR&TXV 13.80 12.00 28,000 3.54 17,600 2.52 8.0 FV4BNF002 28,400 TDR&TXV 13.50 12.15 28,000 3.64 17,600 2.56 8.2 FV4BNF003 28,400 TDR&TXV 13.80 12.00 28,000 3.54 17,600 2.52 8.1 FX4BNF036 28,400 TDR&TXV 12.00 10.50 28,000 3.38 18,700 2.38 7.8 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CE3AA036 27,400 TDR 13.00 11.55 27,600 3.28 17,700 2.42 7.7 CK3BA036 27,800 TDR 13.00 11.80 27,600 3.42 17,700 2.48 8.0 CK5A/CK5BA036 27,800 TDR 13.00 11.80 27,800 3.44 17,700 2.50 8.0 CK5A/CK5BT036 27,000 TDR 13.00 11.80 27,800 3.44 17,800 2.48 8.0 CK5PA036 27,800 TDR&TXV 13.00 11.80 27,800 3.42 17,800 2.48 8.0 CK5PT036 27,800 TDR&TXV 13.00 11.80 27,600 3.42 17,800 2.50 8.0 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CE3AA036 27,400 TDR 13.50 11.80 27,400 3.32 17,600 2.46 7.8 CK3BA036 27,800 TDR 13.50 11.95 27,600 3.46 17,700 2.52 8.0 CK5A/CK5BA036 27,800 TDR 13.50 11.95 27,600 3.46 17,700 2.52 8.0 CK5A/CK5BW036 27,800 TDR 13.50 11.95 27,600 3.46 17,700 2.52 8.0 CK5PA036 27,800 TDR&TXV 13.50 11.95 27,600 3.46 17,700 2.52 8.0 CK5PT036 27,800 TDR&TXV 13.50 11.95 27,800 3.46 17,700 2.52 8.0 CK5PW036 27,800 TDR&TXV 13.50 11.95 27,600 3.46 17,700 2.52 8.0 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 27,400 TDR 12.80 11.25 28,600 3.52 18,100 2.48 8.0 CK5A/CK5BA036 27,400 TDR 13.00 11.25 28,600 3.52 18,100 2.48 8.0 CK5PA036 27,400 TDR&TXV 13.00 11.25 28,600 3.52 18,100 2.48 8.0 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 27,400 TDR 12.80 11.40 28,600 3.54 18,000 2.50 8.0 CK5A/CK5BA036 27,200 TDR 13.00 11.40 28,600 3.54 18,000 2.50 8.0 CK5PA036 27,200 TDR&TXV 13.00 11.40 28,600 3.54 18,000 2.50 8.0 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW036 27,400 TDR 12.50 11.25 28,600 3.52 18,100 2.48 8.0 CK5A/CK5BW036 27,400 TDR 12.80 11.25 28,600 3.52 18,100 2.48 8.0 CK5PW036 27,400 TDR&TXV 12.80 11.25 28,600 3.52 18,100 2.48 8.0 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW036 27,600 TDR 13.00 11.65 28,400 3.60 17,900 2.54 8.1 CK5A/CK5BW036 27,600 TDR 13.00 11.65 28,400 3.60 17,900 2.54 8.1 CK5PW036 27,600 TDR&TXV 13.00 11.65 28,400 3.60 17,900 2.54 8.1 *FX4BNF036 34,000 TDR&TXV 12.50 10.40 37,000 3.48 23,600 2.50 8.0 CC5A/CD5AA042 34,000 NONE 12.00 10.40 36,600 3.40 23,400 2.48 7.8 CC5A/CD5AC048 34,000 NONE 12.00 10.60 36,200 3.34 23,200 2.46 7.7 CC5A/CD5AW042 34,000 NONE 12.00 10.60 36,600 3.40 23,200 2.50 7.8 CC5A/CD5AW048 34,000 NONE 12.00 10.70 36,400 3.50 23,400 2.52 8.0 HSPF 10

UNIT SIZE- SERIES INDOOR UNIT CFM COMBINATION RATINGS* Continued TC Seasonal Efficiency SEER Factory- Supplied Enhancement Standard Rating ARI STANDARD RATINGS* Field-Supplied Accessory High-Temp Heating Low-Temp Puron TXV & TDR** EER TC COP TC COP CD5AA048 34,000 NONE 12.00 10.50 36,600 3.46 23,400 2.50 8.0 CE3AA042 34,000 NONE 12.00 10.70 36,600 3.50 23,400 2.54 8.0 CE3AA048 34,400 NONE 12.50 10.90 36,600 3.56 23,200 2.56 8.1 CF5AA036 34,000 NONE 12.00 10.60 36,400 3.42 23,200 2.50 8.0 CF5AA048 34,400 NONE 12.50 10.85 36,600 3.48 23,200 2.54 8.0 CK3BA048 34,000 NONE 12.50 10.70 36,800 3.56 23,400 2.56 8.1 CK5A/CK5BA042 34,000 NONE 12.00 10.65 36,600 3.50 23,400 2.54 8.0 CK5A/CK5BA048 34,000 NONE 12.50 10.70 36,800 3.56 23,400 2.56 8.1 CK5A/CK5BE042 33,000 NONE 12.30 10.70 36,400 3.36 23,400 2.56 7.9 CK5A/CK5BT042 34,000 NONE 12.00 10.65 36,600 3.50 23,400 2.54 8.0 CK5A/CK5BT048 34,000 NONE 12.50 10.70 36,800 3.56 23,400 2.56 8.1 CK5A/CK5BW048 34,000 NONE 12.50 10.70 36,800 3.56 23,400 2.56 8.1 CK5PA042 34,000 TXV 12.00 10.65 36,600 3.50 23,400 2.54 8.0 CK5PA048 34,000 TXV 12.50 10.70 36,800 3.56 23,400 2.56 8.1 CK5PE042 33,000 TXV 12.30 10.70 36,400 3.36 23,400 2.56 7.9 CK5PT042 34,000 TXV 12.00 10.65 36,600 3.50 23,400 2.54 8.0 CK5PT048 34,000 TXV 12.50 10.70 36,800 3.56 23,400 2.56 8.1 CK5PW048 34,000 TXV 12.50 10.70 36,800 3.56 23,400 2.56 8.1 F(A,B)4BN(F,B,C)042 34,000 TDR 12.00 10.50 36,800 3.46 23,400 2.50 8.0 FC4CN(F,B)042 34,000 TDR&TXV 12.00 10.50 36,800 3.46 23,400 2.50 8.0 FE4ANF002 34,000 TDR&TXV 13.00 11.25 36,000 3.64 22,800 2.62 8.2 FE4ANF003 34,000 TDR&TXV 13.50 11.75 35,200 3.54 22,200 2.62 8.2 FE4ANF005 35,000 TDR&TXV 14.00 12.25 35,000 3.82 22,400 2.74 8.5 FG3AAA048 33,600 NONE 12.00 10.45 36,800 3.52 23,400 2.52 8.2 FK4DNF002 34,000 TDR&TXV 13.00 11.25 36,000 3.64 22,800 2.62 8.2 FK4DNF003 34,000 TDR&TXV 13.50 11.75 35,200 3.54 22,200 2.62 8.2 FK4DNF005 35,000 TDR&TXV 14.00 12.25 35,000 3.82 22,400 2.74 8.5 FV4BNF002 34,000 TDR&TXV 13.00 11.25 36,000 3.64 22,800 2.62 8.2 FV4BNF003 34,000 TDR&TXV 13.50 11.75 35,200 3.54 22,200 2.62 8.2 FV4BNF005 35,000 TDR&TXV 14.00 12.25 35,000 3.82 22,400 2.74 8.5 FX4BNF042 34,400 TDR&TXV 12.50 10.75 36,800 3.58 23,400 2.56 8.2 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CK5A/CK5BE042 34,200 TDR 12.80 11.25 36,200 3.64 22,800 2.62 8.3 CK5PE042 34,200 TDR&TXV 12.80 11.25 36,200 3.64 22,800 2.62 8.3 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CE3AA048 34,400 TDR 13.00 11.45 36,000 3.62 22,200 2.60 8.3 036-B, C CK3BA042 34,200 TDR 13.00 11.40 36,000 3.62 22,200 2.60 8.3 CK3BA048 34,400 TDR 13.00 11.50 36,000 3.70 22,600 2.66 8.5 CK5A/CK5BA042 34,200 TDR 13.00 11.40 36,000 3.62 22,200 2.60 8.3 CK5A/CK5BA048 34,400 TDR 13.00 11.50 36,000 3.68 22,600 2.66 8.5 CK5A/CK5BE042 34,400 TDR 13.00 11.45 36,200 3.68 22,800 2.66 8.5 CK5A/CK5BT042 34,200 TDR 13.00 11.40 36,000 3.62 22,600 2.64 8.3 CK5A/CK5BT048 34,400 TDR 13.00 11.50 36,000 3.70 22,600 2.66 8.5 CK5PA042 34,200 TDR&TXV 13.00 11.40 36,000 3.62 22,200 2.60 8.3 CK5PA048 34,400 TDR&TXV 13.00 11.50 36,000 3.70 22,600 2.66 8.5 CK5PE042 34,400 TDR&TXV 13.00 11.45 36,000 3.68 22,200 2.62 8.4 CK5PT042 34,200 TDR&TXV 13.00 11.40 36,000 3.62 22,200 2.60 8.3 CK5PT048 34,400 TDR&TXV 13.00 11.50 36,000 3.70 22,600 2.66 8.5 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CD5AA048 34,400 TDR 13.10 11.60 35,200 3.64 22,400 2.64 8.4 CE3AA048 34,400 TDR 13.00 11.55 36,000 3.64 22,200 2.60 8.3 CK3BA042 34,200 TDR 13.00 11.50 35,800 3.64 22,200 2.60 8.3 CK3BA048 34,400 TDR 13.10 11.60 36,000 3.72 22,600 2.68 8.5 CK5A/CK5BA042 34,200 TDR 13.00 11.50 35,800 3.64 22,200 2.60 8.3 CK5A/CK5BA048 34,400 TDR 13.10 11.60 36,000 3.72 22,600 2.68 8.5 CK5A/CK5BT042 34,200 TDR 13.00 11.50 35,800 3.64 22,200 2.60 8.3 CK5A/CK5BT048 34,400 TDR 13.10 11.60 36,000 3.72 22,600 2.68 8.5 CK5A/CK5BW048 34,400 TDR 13.10 11.60 36,000 3.72 22,200 2.64 8.5 CK5PA042 34,200 TDR&TXV 13.00 11.50 35,800 3.64 22,200 2.60 8.3 CK5PA048 34,400 TDR&TXV 13.10 11.60 36,000 3.70 22,600 2.68 8.5 CK5PT042 34,200 TDR&TXV 13.00 11.50 35,800 3.64 22,200 2.60 8.3 CK5PT048 34,400 TDR&TXV 13.10 11.60 36,000 3.72 22,200 2.64 8.5 CK5PW048 34,400 TDR&TXV 13.10 11.60 36,000 3.72 22,600 2.68 8.5 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AW048 34,200 TDR 13.10 11.60 35,200 3.64 22,400 2.62 8.4 CD5AA048 34,200 TDR 13.10 11.60 35,200 3.64 22,400 2.64 8.4 CE3AA048 34,400 TDR 13.00 11.50 36,000 3.64 22,200 2.60 8.3 CK3BA042 34,200 TDR 13.00 11.45 35,800 3.64 22,200 2.60 8.3 CK3BA048 34,400 TDR 13.10 11.55 36,000 3.70 22,600 2.68 8.5 CK5A/CK5BA042 34,200 TDR 13.00 11.45 36,000 3.64 22,200 2.60 8.3 CK5A/CK5BA048 34,400 TDR 13.10 11.55 36,000 3.70 22,600 2.68 8.5 CK5A/CK5BT042 34,200 TDR 13.00 11.45 35,800 3.64 22,200 2.60 8.3 CK5A/CK5BT048 34,400 TDR 13.10 11.55 36,000 3.70 22,600 2.68 8.5 CK5A/CK5BW048 34,400 TDR 13.10 11.55 36,000 3.70 22,600 2.68 8.5 See notes on page 15. Puron TXV HSPF 11

UNIT SIZE- SERIES 036-B, C See notes on page 15. INDOOR UNIT CFM COMBINATION RATINGS* Continued TC Seasonal Efficiency SEER Factory- Supplied Enhancement Standard Rating CK5PA042 34,200 TDR&TXV 13.00 11.45 35,800 3.64 22,200 2.60 8.3 CK5PA048 34,400 TDR&TXV 13.10 11.55 36,000 3.70 22,200 2.64 8.5 CK5PT042 34,200 TDR&TXV 13.00 11.45 36,000 3.64 22,200 2.60 8.3 CK5PT048 34,400 TDR&TXV 13.10 11.55 36,000 3.70 22,600 2.68 8.5 CK5PW048 34,400 TDR&TXV 13.10 11.55 36,000 3.70 22,200 2.64 8.5 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AW042 34,000 TDR 13.00 11.50 35,400 3.50 22,400 2.60 8.2 CC5A/CD5AW048 34,400 TDR 13.20 11.65 35,200 3.64 22,400 2.64 8.4 CD5AA048 34,400 TDR 13.20 11.65 35,000 3.64 22,400 2.64 8.4 CE3AA048 34,400 TDR 13.10 11.60 35,800 3.64 22,200 2.62 8.4 CK3BA042 34,200 TDR 13.00 11.50 35,800 3.64 22,200 2.62 8.4 CK3BA048 34,600 TDR 13.20 11.70 36,000 3.72 22,200 2.64 8.5 CK5A/CK5BA042 34,200 TDR 13.00 11.50 35,800 3.64 22,000 2.62 8.4 CK5A/CK5BA048 34,600 TDR 13.20 11.70 36,000 3.72 22,600 2.68 8.5 CK5A/CK5BT042 34,200 TDR 13.00 11.50 35,800 3.64 22,200 2.62 8.4 CK5A/CK5BT048 34,600 TDR 13.20 11.70 36,000 3.72 22,200 2.64 8.5 CK5A/CK5BW048 34,600 TDR 13.20 11.70 36,000 3.72 22,600 2.68 8.5 CK5PA042 34,200 TDR&TXV 13.00 11.50 35,800 3.64 22,200 2.62 8.4 CK5PA048 34,600 TDR&TXV 13.20 11.70 36,000 3.72 22,600 2.68 8.5 CK5PT042 34,200 TDR&TXV 13.00 11.50 35,800 3.66 22,000 2.62 8.4 CK5PT048 34,600 TDR&TXV 13.20 11.70 36,000 3.72 22,600 2.68 8.5 CK5PW048 34,600 TDR&TXV 13.20 11.70 36,000 3.72 22,600 2.68 8.5 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,000 TDR 13.20 11.70 35,800 3.48 22,600 2.60 8.0 CD5AA048 34,000 TDR 13.30 11.75 36,000 3.54 22,600 2.62 8.1 CK5A/CK5BA042 34,000 TDR 13.20 11.70 35,800 3.48 22,600 2.60 8.0 CK5A/CK5BA048 34,000 TDR 13.30 11.75 36,000 3.54 22,600 2.62 8.1 CK5A/CK5BE042 33,000 TDR 13.10 11.75 35,600 3.34 22,600 2.62 7.9 CK5A/CK5BW048 34,600 TDR 13.00 11.50 36,800 3.62 23,200 2.64 8.2 CK5PA042 34,000 TDR&TXV 13.20 11.70 35,800 3.48 22,600 2.60 8.0 CK5PA048 34,000 TDR&TXV 13.30 11.75 36,000 3.54 22,600 2.62 8.1 CK5PE042 33,000 TDR&TXV 13.10 11.75 35,600 3.34 22,600 2.62 7.9 CK5PW048 34,600 TDR&TXV 13.00 11.50 36,800 3.62 23,200 2.64 8.2 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,400 TDR 13.00 11.35 36,800 3.54 23,200 2.60 8.1 CD5AA048 34,000 TDR 13.20 11.75 36,000 3.52 22,600 2.62 8.1 CK5A/CK5BA042 34,200 TDR 13.00 11.35 36,800 3.54 23,200 2.60 8.1 CK5A/CK5BA048 34,000 TDR 13.20 11.75 36,000 3.52 22,600 2.62 8.1 CK5A/CK5BE042 33,400 TDR 12.60 11.45 36,600 3.42 23,200 2.62 8.0 CK5PA042 34,200 TDR&TXV 13.00 11.35 36,800 3.54 23,200 2.60 8.1 CK5PA048 34,000 TDR&TXV 13.20 11.75 36,000 3.52 22,600 2.62 8.1 CK5PE042 33,400 TDR&TXV 12.60 11.45 36,600 3.42 23,200 2.62 8.0 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,200 TDR 13.00 11.50 36,600 3.56 23,000 2.62 8.1 CK5A/CK5BA042 34,200 TDR 13.00 11.50 36,600 3.56 23,000 2.62 8.1 CK5A/CK5BA048 34,000 TDR 13.40 11.85 36,000 3.54 22,600 2.64 8.2 CK5PA042 34,200 TDR&TXV 13.00 11.50 36,600 3.56 23,000 2.62 8.1 CK5PA048 34,000 TDR&TXV 13.40 11.85 36,000 3.54 22,600 2.64 8.2 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,200 TDR 13.00 11.35 36,800 3.54 23,200 2.60 8.1 CD5AA048 34,200 TDR 12.70 11.35 37,000 3.60 23,200 2.62 8.2 CK5A/CK5BA042 34,200 TDR 13.00 11.35 36,800 3.54 23,200 2.60 8.1 CK5A/CK5BA048 34,000 TDR 13.20 11.75 36,000 3.52 22,600 2.62 8.1 CK5PA042 34,200 TDR&TXV 13.00 11.35 36,800 3.54 23,200 2.60 8.1 CK5PA048 34,000 TDR&TXV 13.20 11.75 36,000 3.52 22,600 2.62 8.1 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13.30 11.75 36,400 3.62 23,000 2.66 8.3 CK5A/CK5BA042 34,600 TDR 13.30 11.75 36,400 3.62 23,000 2.66 8.3 CK5A/CK5BE042 33,200 TDR 13.30 12.00 35,400 3.38 22,400 2.66 8.0 CK5PA042 34,600 TDR&TXV 13.30 11.75 36,400 3.62 23,000 2.66 8.3 CK5PE042 33,200 TDR&TXV 13.30 12.00 35,400 3.38 22,400 2.66 8.0 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA042 34,200 TDR 13.50 11.95 35,600 3.52 22,400 2.62 8.1 CD5AA048 34,000 TDR 13.50 12.00 35,800 3.58 22,400 2.64 8.2 CK5A/CK5BA042 34,200 TDR 13.50 11.95 35,600 3.52 22,400 2.62 8.1 CK5A/CK5BA048 34,000 TDR 13.50 12.00 35,800 3.58 22,400 2.64 8.2 CK5A/CK5BE042 33,000 TDR 13.30 12.00 35,400 3.38 22,400 2.64 8.0 CK5A/CK5BW048 34,600 TDR 13.40 11.85 36,600 3.70 23,000 2.68 8.3 CK5PA042 34,200 TDR&TXV 13.50 11.95 35,600 3.52 22,400 2.62 8.1 CK5PA048 34,000 TDR&TXV 13.50 12.00 35,800 3.58 22,400 2.64 8.2 CK5PE042 33,000 TDR&TXV 13.30 12.00 35,400 3.38 22,400 2.64 8.0 CK5PW048 34,600 TDR&TXV 13.40 11.85 36,600 3.70 23,000 2.68 8.3 12 ARI STANDARD RATINGS* Field-Supplied Accessory Puron TXV High-Temp Heating Low-Temp Puron TXV & TDR** EER TC COP TC COP HSPF

UNIT SIZE- SERIES INDOOR UNIT CFM COMBINATION RATINGS* Continued TC Seasonal Efficiency SEER Factory- Supplied Enhancement Standard Rating *FX4BNF042 40,500 TDR&TXV 12.00 10.25 41,500 3.40 26,600 2.42 7.6 CC5A/CD5AC048 39,500 NONE 12.00 10.10 39,500 3.04 26,200 2.32 7.0 CC5A/CD5AW048 40,000 NONE 12.00 10.25 40,500 3.28 26,400 2.38 7.6 CD5AA048 40,000 NONE 12.00 10.25 40,500 3.28 26,400 2.38 7.6 CE3AA048 40,500 NONE 12.00 10.35 41,500 3.32 26,400 2.40 7.6 CK3BA048 40,000 NONE 12.00 10.30 41,500 3.34 26,400 2.40 7.6 CK5A/CK5BA048 40,000 NONE 12.00 10.30 41,500 3.34 26,400 2.40 7.6 CK5A/CK5BE042 39,000 NONE 11.80 10.30 41,000 3.14 26,400 2.40 7.4 CK5A/CK5BW048 40,000 NONE 12.00 10.30 41,500 3.34 26,400 2.40 7.6 CK5PA048 40,000 TXV 12.00 10.30 41,500 3.34 26,400 2.40 7.6 CK5PE042 39,000 TXV 11.80 10.30 41,000 3.14 26,400 2.40 7.4 CK5PW048 40,000 TXV 12.00 10.30 41,500 3.34 26,400 2.40 7.6 F(A,B)4BN(F,B,C)048 40,000 TDR 12.00 10.25 41,500 3.34 26,600 2.42 7.6 FC4CN(F,B)048 40,500 TDR&TXV 12.00 10.25 41,500 3.38 26,600 2.42 7.6 FE4ANF003 40,500 TDR&TXV 13.00 11.00 40,500 3.36 25,400 2.46 7.7 FE4ANF005 41,000 TDR&TXV 13.50 11.55 40,000 3.56 25,200 2.56 8.1 FK4DNF003 40,500 TDR&TXV 13.00 11.10 40,000 3.32 25,400 2.44 7.6 FK4DNF005 41,000 TDR&TXV 13.50 11.55 40,000 3.56 25,200 2.56 8.0 FV4BNF003 40,500 TDR&TXV 13.00 11.00 40,500 3.36 25,400 2.46 7.7 FV4BNF005 41,000 TDR&TXV 13.50 11.55 40,000 3.56 25,200 2.56 8.1 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CE3AA048 40,000 TDR 12.70 11.00 41,000 3.34 25,600 2.46 7.5 CK3BA048 40,000 TDR 12.80 11.05 41,000 3.38 25,600 2.46 7.6 CK5A/CK5BA048 40,000 TDR 12.80 11.05 41,000 3.38 25,400 2.48 7.6 CK5A/CK5BT048 40,000 TDR 12.80 11.05 41,000 3.38 25,400 2.48 7.6 CK5PA048 40,000 TDR&TXV 12.80 11.05 41,000 3.38 25,400 2.48 7.6 CK5PT048 40,000 TDR&TXV 12.80 11.05 41,000 3.38 25,400 2.48 7.6 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CC5A/CD5AW048 40,000 TDR 12.80 11.20 40,500 3.30 25,200 2.46 7.5 CD5AA048 40,000 TDR 12.80 11.20 40,500 3.32 25,200 2.46 7.5 CE3AA048 40,000 TDR 12.80 11.15 40,500 3.36 25,400 2.46 7.6 CK3BA048 40,000 TDR 12.90 11.15 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BA048 40,000 TDR 12.90 11.15 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BT048 40,000 TDR 12.90 11.15 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BW048 40,000 TDR 12.90 11.15 40,500 3.42 25,400 2.50 7.7 CK5PA048 40,000 TDR&TXV 12.90 11.15 40,500 3.42 25,400 2.50 7.7 042-B, C CK5PT048 40,000 TDR&TXV 12.90 11.15 40,500 3.42 25,400 2.50 7.7 CK5PW048 40,000 TDR&TXV 12.90 11.15 40,500 3.42 25,400 2.50 7.7 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AW048 40,000 TDR 12.80 11.20 40,500 3.30 25,200 2.46 7.5 CD5AA048 40,000 TDR 12.80 11.20 40,500 3.32 25,200 2.46 7.5 CE3AA048 40,000 TDR 12.80 11.15 40,500 3.36 25,400 2.46 7.6 CK3BA048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BA048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BT048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BW048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5PA048 40,000 TDR&TXV 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5PT048 40,000 TDR&TXV 12.90 11.20 41,000 3.42 25,400 2.50 7.7 CK5PW048 40,000 TDR&TXV 12.90 11.20 40,500 3.42 25,400 2.50 7.7 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AW048 40,000 TDR 12.90 11.25 40,500 3.32 25,200 2.46 7.5 CD5AA048 40,000 TDR 12.90 11.25 40,500 3.32 25,200 2.46 7.5 CE3AA048 40,500 TDR 12.90 11.15 40,500 3.36 25,400 2.48 7.6 CK3BA048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BA048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BT048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5A/CK5BW048 40,000 TDR 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5PA048 40,000 TDR&TXV 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5PT048 40,000 TDR&TXV 12.90 11.20 40,500 3.42 25,400 2.50 7.7 CK5PW048 40,000 TDR&TXV 12.90 11.20 40,500 3.42 25,400 2.50 7.7 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AW048 40,000 TDR 12.50 10.80 40,500 3.32 25,600 2.44 7.6 CK5A/CK5BW048 40,000 TDR 12.50 10.80 40,500 3.32 25,600 2.44 7.6 CK5PW048 40,000 TDR&TXV 12.50 10.80 40,500 3.32 25,600 2.44 7.6 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CD5AA048 40,000 TDR 12.70 10.90 40,500 3.34 25,600 2.44 7.6 CK3BA048 40,000 TDR 12.70 10.90 40,500 3.34 25,600 2.44 7.6 CK5A/CK5BA048 40,000 TDR 12.70 10.90 40,500 3.34 25,600 2.44 7.6 CK5PA048 40,000 TDR&TXV 12.70 10.90 40,500 3.34 25,600 2.44 7.6 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CD5AA048 40,000 TDR 12.50 10.75 40,500 3.32 25,600 2.42 7.6 CK3BA048 40,000 TDR 12.50 10.75 40,500 3.32 25,600 2.42 7.6 See notes on page 15. 13 ARI STANDARD RATINGS* Field-Supplied Accessory Puron TXV High-Temp Heating Low-Temp Puron TXV & TDR** EER TC COP TC COP HSPF

UNIT SIZE- SERIES 042-B, C 048-B, C See notes on page 15. INDOOR UNIT CFM TC COMBINATION RATINGS* Continued Seasonal Efficiency SEER Factory- Supplied Enhancement Standard Rating CK5A/CK5BA048 40,000 TDR 12.50 10.75 40,500 3.32 25,600 2.42 7.6 CK5PA048 40,000 TDR&TXV 12.50 10.75 40,500 3.32 25,600 2.42 7.6 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CD5AA048 40,000 TDR 13.00 11.10 40,500 3.36 25,400 2.46 7.6 CK3BA048 40,000 TDR 13.00 11.10 40,500 3.36 25,400 2.46 7.6 CK5A/CK5BA048 40,000 TDR 13.00 11.10 40,500 3.36 25,400 2.46 7.6 CK5A/CK5BW048 40,000 TDR 12.50 10.80 40,500 3.32 25,600 2.44 7.6 CK5PA048 40,000 TDR&TXV 13.00 11.10 40,500 3.36 25,400 2.46 7.6 CK5PW048 40,000 TDR&TXV 12.50 10.80 40,500 3.32 25,600 2.44 7.6 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AW048 40,000 TDR 13.00 11.05 40,500 3.36 25,400 2.46 7.6 CK5A/CK5BW048 40,000 TDR 13.00 11.05 40,500 3.36 25,400 2.46 7.6 CK5PW048 40,000 TDR&TXV 13.00 11.05 40,500 3.36 25,400 2.46 7.6 *FX4BNF048 45,000 TDR&TXV 12.00 10.75 48,000 3.42 28,400 2.34 8.0 CC5A/CD5AA060 44,500 NONE 12.00 10.60 48,000 3.22 28,400 2.26 7.7 CC5A/CD5AW060 44,500 NONE 12.00 10.80 48,000 3.40 28,400 2.34 8.0 CE3AA060 45,500 NONE 12.00 10.80 48,500 3.40 28,400 2.34 8.0 CK3BA060 45,000 NONE 12.00 10.75 48,000 3.50 28,600 2.38 8.0 CK5A/CK5BA060 45,000 NONE 12.00 10.75 48,000 3.50 28,600 2.38 8.0 CK5A/CK5BX060 45,500 NONE 12.00 10.90 48,500 3.52 28,600 2.38 8.2 CK5PA060 45,000 TXV 12.00 10.75 48,000 3.50 28,600 2.38 8.0 CK5PX060 45,500 TXV 12.00 10.90 48,500 3.52 28,600 2.38 8.2 F(A,B)4BN(F,B,C)060 44,000 TDR 11.50 10.20 48,500 3.32 29,000 2.26 7.6 FB4BNB070 46,000 TDR 12.00 10.90 48,000 3.54 28,600 2.38 8.0 FC4CN(F,B)060 44,500 TDR&TXV 11.50 10.20 48,000 3.32 29,000 2.26 7.6 FC4CNB070 46,000 TDR&TXV 12.00 10.90 48,000 3.54 28,600 2.38 8.0 FE4ANB006 46,500 TDR&TXV 13.50 12.05 48,000 3.76 27,600 2.54 8.3 FE4ANF005 45,500 TDR&TXV 13.00 11.60 47,500 3.58 27,600 2.46 8.2 FG3AAA060 44,000 NONE 12.20 10.70 47,000 3.48 27,400 2.44 8.0 FK4DNB006 46,500 TDR&TXV 13.50 12.05 48,000 3.76 27,600 2.54 8.3 FK4DNF005 45,500 TDR&TXV 13.00 11.60 47,500 3.58 27,800 2.46 8.2 FV4BNB006 46,500 TDR&TXV 13.50 12.05 48,000 3.76 27,600 2.54 8.3 FV4BNF005 45,500 TDR&TXV 13.00 11.60 47,500 3.58 27,600 2.46 8.2 FX4BNB060 45,500 TDR&TXV 12.20 10.90 48,000 3.54 28,600 2.38 8.1 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CE3AA060 44,500 TDR 12.90 11.40 47,500 3.64 27,400 2.50 8.5 COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE CD5PX060 45,000 TDR&TXV 13.40 11.70 48,000 3.68 27,600 2.50 8.5 CE3AA060 45,000 TDR 13.20 11.60 47,500 3.42 27,800 2.40 8.1 CK3BA060 44,500 TDR 13.20 11.60 47,500 3.60 27,600 2.46 8.3 CK5A/CK5BA060 44,500 TDR 13.20 11.60 47,000 3.48 27,400 2.42 8.1 CK5A/CK5BT060 44,500 TDR 13.20 11.60 47,500 3.60 27,600 2.46 8.3 CK5A/CK5BX060 45,500 TDR 13.50 11.85 47,500 3.60 27,600 2.46 8.3 CK5PA060 44,500 TDR&TXV 13.20 11.60 47,500 3.60 27,600 2.46 8.3 CK5PT060 44,500 TDR&TXV 13.20 11.60 47,500 3.60 27,600 2.46 8.3 CK5PX060 45,500 TDR&TXV 13.50 11.85 47,500 3.62 27,600 2.50 8.5 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AW060 44,500 TDR 13.20 11.60 47,000 3.46 27,400 2.42 8.1 CE3AA060 45,000 TDR 13.20 11.60 47,000 3.48 27,400 2.42 8.1 CK3BA060 44,500 TDR 13.10 11.55 47,500 3.58 27,600 2.46 8.3 CK5A/CK5BA060 44,500 TDR 13.10 11.55 47,500 3.62 27,600 2.50 8.5 CK5A/CK5BT060 44,500 TDR 13.10 11.55 47,500 3.58 27,600 2.46 8.3 CK5A/CK5BX060 45,500 TDR 13.50 11.75 47,500 3.58 27,600 2.46 8.3 CK5PA060 44,500 TDR&TXV 13.10 11.55 47,500 3.58 27,600 2.46 8.3 CK5PT060 44,500 TDR&TXV 13.10 11.55 47,500 3.58 27,600 2.46 8.3 CK5PX060 45,500 TDR&TXV 13.50 11.75 47,500 3.62 27,600 2.48 8.3 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AW060 44,500 TDR 13.40 11.70 47,000 3.28 27,200 2.34 7.8 CE3AA060 45,000 TDR 13.20 11.70 47,000 3.46 27,600 2.42 8.1 CK3BA060 44,500 TDR 13.40 11.65 47,500 3.60 27,400 2.48 8.3 CK5A/CK5BA060 44,500 TDR 13.40 11.65 47,500 3.62 27,600 2.48 8.3 CK5A/CK5BT060 44,500 TDR 13.40 11.65 47,500 3.60 27,400 2.48 8.3 CK5A/CK5BX060 45,500 TDR 13.50 11.85 47,500 3.60 27,400 2.48 8.3 CK5PA060 44,500 TDR&TXV 13.40 11.65 47,500 3.60 27,400 2.48 8.3 CK5PT060 44,500 TDR&TXV 13.40 11.65 47,500 3.60 27,400 2.48 8.3 CK5PX060 45,500 TDR&TXV 13.50 11.85 47,500 3.64 27,400 2.50 8.5 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA060 44,000 TDR 12.50 10.90 48,000 3.44 28,200 2.36 8.0 CC5A/CD5AW060 44,500 TDR 12.50 11.10 48,000 3.48 28,200 2.38 8.0 CK3BA060 44,000 TDR 12.50 10.90 47,500 3.44 28,200 2.36 8.0 CK5A/CK5BA060 44,000 TDR 12.50 10.90 47,500 3.44 28,200 2.36 8.0 CK5A/CK5BX060 44,500 TDR 12.50 11.10 48,000 3.48 28,200 2.38 8.0 14 ARI STANDARD RATINGS* Field-Supplied Accessory Puron TXV High-Temp Heating Low-Temp Puron TXV & TDR** EER TC COP TC COP HSPF