Boiler System Expansion Tanks

Similar documents
Hydronic Expansion Tanks THE ONE THAT STARTED IT ALL

EXTROL EXPANSION TANKS

Hot Water Makers. Efficiency at its Best

THERM-X-TROL THERMAL EXPANSION ABSORBERS. The Best Solution for Controlling Thermal Expansion. As Seen On

THERMAL EXPANSION ABSORBERS

Commercial Hot Water Maker

Well Tanks and Expansion Tanks

Indirect-Fired Water Heaters. BoilerMate Classic & Champion Series

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Indirect-Fired Water Heaters

Indirect-Fired Water Heaters

Indirect-Fired Water Heaters

GLOBAL FLOW PRODUCTS

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

TECHNICAL. Series 18. Pump Packages

Thermal Expansion and Your Water Heater. Bradford White Explains What it is and How to Protect Yourself and Your Family From it.

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

Peerless Pump Company

In-Line Air Separators

Champion Series INDIRECT-FIRED WATER HEATER. All Champion Series

SECTION HYDRONIC PIPING AND SPECIALTIES

CORNELL PUMP COMPANY REFRIGERATION EFFICIENT BY DESIGN

Suggested Specifications Prestige Excellence 110

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

HYDROMAX INDIRECT-FIRED WATER HEATERS

Technical Data Manual Model Nos. and pricing: see Price List

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

Heat Transfer Equipment

Marine Heat Exchangers SALES SERVICE REPAIR

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection

Heat Transfer Packages

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

technological solutions LIST PRICE BOOK Building the Future Together Effective November 1, 2016 All Prior Issues Void PL-CIM_V0013.

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Expansion Tank Design (Hydronic Hot Water)

SKU: HSPS190MPH. Multi Zone, High Temp Panel. 190K BTU Zoning By Pumps-Zone Panel Required* Up to 4 Zones*

Peerless Boilers. Series MI. Residential Gas Boilers

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

Automatic Temperature Controller (ATC)

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

Taco 00 Series Cartridge Circulators

Intelligent Refrigeration Solutions

Hydronic Specialties and Circulator Pumps

DIVISION 23 HVAC Hydronic Piping Systems

MAC N-407 Air-Cooled Chiller

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Industrial Refrigeration. Brochure R/S CB 02/10

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

Hydronic Product & Application Catalog

Allcan TM Installation Manual

High Capacity Instantaneous Steam Fired Water Heater

11.4 Component Assembly Diagrams and Parts Lists Case Assembly

HVAC No. MFG Part No. Description Size Price

Heating Installation Guide published by

Lubrication Tools and Equipment Portable Oil Drains

5. CONDENSATE PUMPS/UNITS

Application Guide. Vitodens 222-F B2TB Residential Boiler

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

Thermostatic Control Valves

Product Family Overview

HYDROMAX. Models HM-41 & HM-80 INSTALLATION & OPERATION INSTRUCTIONS INDIRECT-FIRED WATER HEATERS

Header Tank Heat Exchangers

SINGLE STAGE MULTI STAGE NANO MICRO

PACKAGED AIR COOLED Product Data Catalog

AIR TO WATER. Heat Pumps & Chillers

Nirvana Cycling Refrigerated Dryers

SILVER CAST IRON BOILERS. P e n n c o S I LV E R m a k e s S i m pl e C o m f o r t, A f f o r d a b l e.

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

2015 UPC Chapter 8 Indirect Wastes RV

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION SECTION DESIGN REQUIREMENTS

Used Fluid Handling Portable Used-Oil Gravity Drains

Warmth, efficiency, and total peace of mind.

Industrial. Solutions brands you trust. Product Overview

Fundamentals of Hydronic Design

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

Silhouette. Feedwater Heater. Boiler Feedwater

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Technical Data Manual Model Nos. and pricing: see Price List

WATER HEATERS Range of Products. Everyday comfort.

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Transcription:

oiler Expansion s Extrol. First In Expansion Control.

mtrol Inc. designed and patented the first Extrol diaphragm expansion tank in 1954 to control system pressure and help reduce energy consumption in heating and chilled water systems. Over six decades later, Extrol is still the world s leading expansion tank brand, setting the standard for quality, reliability and innovation. ll Extrol tanks are made in the US at our ISO registered facilities by merican workers dedicated to producing the highest quality expansion tanks in the world. mtrol s patent for the first diaphragm tank was issued over 60 years ago. merican Tube Products founded in West Warwick, Rhode Island 1946 pre-pressurized well tank uilt current Rhode Island manufacturing facility indirect-fired Hot Water Maker Opened the mtrol Education Center MTROL registered ISO 9001 1963 1972 1980 1988 1992 1954 1967 1975 1986 1991 diaphragm expansion tank refrigerant gas cylinder Entered the commercial products business top coil indirect Hot Water Maker thermal expansion tank 2

The One That Started It ll. The complete line of Extrol tanks includes inline, floor-standing, air elimination packages and special application models. cquired LF Cylinder Manufacturing in Portugal composite metal LP tank Well-X-Trol 50th nniversary 1997 2005 2010 2013 MTROL registered ISO 9001:2008 s on Tour mobile education center hits the road MTROL registered ISO 9001:2000 Launched Next Generation Well-X-Trol 2003 2009 2012 2014 Launched mtrol Rewards 20 millionth well tank shipped Launched HydroMax Hot Water Makers Extrol 60th nniversary 3

utomatic ir Vent eliminates system air ir Purger separates air from water connection sets the point of no pressure change Watertight reservoir for expanded water Thick, heavy duty utyl/epdm diaphragm for long service life Sealed air cushion factory pre-charged and 100% tested Factory precharge: 12 psig Max. working pressure: 100 psig Max. operating temperature: 240 F Strong, deep-drawn steel tank Projection-welded air stem maintains precharge setting 4

s and Specifications EX Series Specifications Max. cceptance Factor (NPTM) EX-15 2.0 1.0 8 13 1 2 5 EX-30 4.4 2.5 11 15 1 2 9 EX-60 7.4 2.5 11 23 1 2 14 EX-90 14.0 11.3 15 21 1 2 23 EX Series Combination Packages s (NPTF) EXTROL ir Purger ir Vent EX-1500-100 1 EX-15 443 700-C 10 EX-1500-125 1 1 4 EX-15 444 700-C 10 EX-3000-100 1 EX-30 443 700-C 14 EX-3000-125 1 1 4 EX-30 444 700-C 14 EX Series Sizing oiler Type of Radiation Net Output in 1000 S of TU/Hr. Finned aseboard or Radiant Panels Convectors or Unit Heaters Radiators Cast Iron aseboard Cast Iron MH Use Use Use Use 25 EX-15 EX-15 EX-15 EX-15 50 EX-15 EX-15 EX-30 EX-30 75 EX-30 EX-30 EX-30 EX-60 100 EX-30 EX-30 EX-60 EX-60 125 EX-30 EX-60 EX-60 EX-90 150 EX-30 EX-60 EX-90 EX-90 175 EX-60 EX-60 SX Series SX Series 200 EX-60 EX-60 SX Series SX Series 250 EX-60 EX-90 SX Series SX Series 300 EX-90 SX Series SX Series SX Series Sizing based on: 12 psig Fill; 30 psig Relief Valve; 200 F verage Temperature. For sizing with fluids other than water, visit amtrol.com, download the MTROL pp or consult MTROL Technical Support. Typical Installation ir Vent Fill Valve Cold Water ir Purger Return Circulator Extrol Expansion oiler 5

Floor-Standing s Extrol floor-standing models are designed for large residential and light commercial applications. These non-sme tanks are available in sizes up to 86 gallons and can be used with high output boilers up to 1,500,000 TU's (see sizing charts). SME Commercial tanks are also available and can be found in catalog MC 2682. SX Series Specifications Max. ccept. (NPTF) SX-30V 14 11.3 15 24 1 25 SX-40V 20 11.3 15 32 1 33 SX-60V 32 11.3 15 48 1 43 SX-90V 44 34.0 22 36 1 1 4 69 SX-110V 62 34.0 22 47 1 1 4 92 SX-130V 81 34.0 22 56 1 1 4 103 SX-160V 86 46.0 26 47 1 1 4 123 Factory pre-charge: 12 psig. Maximum working pressure: 100 psig. Maximum operating temperature: 240 F. Sizing oiler Type of Radiation and Piping Net Output in 1000 s of TU Finned Tube aseboard or Radiant Panels with Series Loop Convectors or Unit Heaters with One Pipe Radiators or One Pipe Cast Iron Radiators with Series Loop 200 SX- 30V SX-30V SX-30V SX-30V 250 SX- 30V SX-30V SX-30V SX-40V 300 SX- 30V SX-30V SX-40V SX-40V Typical Installation ir Vent Fill Valve Water 350 SX-30V SX-30V SX-40V SX-60V 400 SX-30V SX-40V SX-60V SX-60V 450 SX-40V SX-40V SX-90V SX-90V 500 SX-40V SX-40V SX-60V SX-90V 550 SX-40V SX-60V SX-60V SX-90V 600 SX-40V SX-60V SX-90V SX-90V ir Separator Return 650 SX-60V SX-60V SX-90V SX-90V 700 SX-60V SX-60V SX-90V SX-90V 750 SX-60V SX-60V SX-90V SX-110V Circulator 800 SX-60V SX-90V SX-90V SX-110V 850 SX-60V SX-90V SX-90V SX-110V 900 SX-60V SX-90V SX-110V SX-110V 950 SX-90V SX-90V SX-110V SX-110V 1,000 SX-90V SX-90V SX-110V SX-110V Extrol Expansion oiler 1,100 SX-90V SX-90V SX-110V SX-130V 1,200 SX-90V SX-90V SX-110V SX-130V 1,300 SX-90V SX-110V SX-130V SX-160V 1,400 SX-110V SX-130V SX-160V SX-160V 1,500 SX-110V SX-130V SX-160V (2)SX-110V Sizing based on: verage oiler Water ; verage Water ; Fill Pressure 12 psig; Relief Pressure 30 psig For other boiler sizes or operating conditions, consult MTROL Technical Support. 6

Special pplication Expansion s FILL-TROL Eliminates the need for a separate, automatic fill valve. pressure controls system fill. Factory pre-charge: 12 psig. Fully adjustable up to a maximum working pressure of 100 psig. Removable Strainer Cold Water 1/2 Compression Fitting Spring-Loaded Check Valve Fill Gate Stem O-Ring Seal Pressure bove Diaphragm utomatic Shut-Off Valve Spring Expansion ypass utomatic Shut-Off Valve Pressure Plate Diaphragm FT-109 2.0 1.0 8 15 1 2 6 FT-110 4.4 2.5 11 17 1 2 10 FT-111 7.4 2.5 11 25 1 2 15 FT-112 14.0 11.3 15 23 1 2 24 Note: standard EXTROL tank is not interchangeable with a FILL-TROL tank. FT-109 is equivalent to EX-15; FT-110 is equivalent to EX-30; FT-111 is equivalent to EX-60 and FT-112 is equivalent to EX-90. Fill-Trol Specifications Max. ccept. Combination Packages s (NPTF) FILL-TROL ir Purger (NPTF) ir Vent FT-109-100 1 109 443 700-C 10 FT-109-125 1 1 4 109 444 700-C 10 FT-110-100 1 110 443 700-C 14 FT-110-125 1 1 4 110 444 700-C 14 FT-111-125 1 1 4 111 444 700-C 18 RDINT EXTROL For low temperature systems. Plastic liner is compatible with barrier and non-barrier tubing. Suitable for use in glycol applications. Stainless steel connection for corrosion resistance. Factory pre-charge: 12 psig. Maximum working pressure: 100 psig. Maximum operating temperature: 200 F. Radiant Extrol Specifications Max. ccept. Sizing RX-15 2.0 0.9 8 13 1 2 NPTM 5 RX-30 4.4 3.2 11 15 1 2 NPTM 9 RX-60 10.3 10.3 15 19 3 4 NPTF 23 Feet of Nominal Pex Tubing Size Tubing 3/8" 1/2" 5/8" 3/4" 1" 1,000 RX-15 RX-15 RX-15 RX-15 RX-15 5,000 RX-15 RX-15 RX-15 RX-30 RX-30 7,500 RX-15 RX-15 RX-30 RX-30 RX-60 10,000 RX-15 RX-30 RX-30 RX-60 RX-60 14,000 RX-15 RX-30 RX-60 RX-60 18,000 RX-30 RX-60 RX-60 RX-60 22,000 RX-30 RX-60 RX-60 30,000 RX-30 RX-60 Contact mtrol Sizing based on: Fill Pressure 12 psig; Relief Pressure 30 psig; verage Temperature 120 F; filled with water. For glycol applications, consult MTROL Technical Support. SOLR EXTROL For high-efficiency solar systems. Suitable for use in glycol applications. Factory pre-charge: 25 psig. Maximum working pressure: 150 psig. Maximum operating temperature: 250 F. Solar Extrol Specifications Max. ccept. (NPTM) SE-15 2.0 1.0 8 13 1 2 5 SE-30 4.4 2.5 11 16 1 2 9 SE-60 7.4 2.5 11 23 1 2 14 For Precise Sizing, visit www.amtrol.com or consult MTROL Technical Support. Sizing verage Operating Temperature 140 F 160 F 180 F 200 F 220 F 10 SE-15 SE-15 SE-15 SE-15 SE-15 20 SE-30 SE-30 SE-30 SE-30 SE-30 30 SE-30 SE-30 SE-60 SE-60 SE-60 40 SE-60 SE-60 SE-60 50 SE-60 SE-60 Contact mtrol Sizing based on: 50% Water and Propylene Glycol Max; 25 psig Fill; 50 psig Relief Valve. For other applications, consult MTROL Technical Support. 7

mtrol dvantage Whenever you choose mtrol, you re getting more than just a great product. The mtrol dvantage combines the Industry s best brands with world class customer service and valuable installer initiatives. mtrol Rewards installer points program s on Tour field training vehicle mtrol Racing team 1400 Division Road, West Warwick, RI US 02893 T: 800.426.8765 F: 800.293.1519 www.amtrol.com Mark of the Originator 2015 MTROL Inc. MC 2680 (01/15)