Installation Instructions / User s Manual NAXA00101DB Communicating Daughter Board

Similar documents
Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

User s Information and Installation Instructions

User s Information and Installation Instructions

Split system air conditioner

Trouble Shooting Guide PWA, 3-phase (D10571)

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

Trouble Shooting Guide FAA, 3-phase (D3631)

Air Conditioning Operation and Troubleshooting Matt Dunham

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioner N4A3, C4A3, H4A3, T4A3, NXA6, CXA6, HXA6, TXA6

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

INSTALLATION INSTRUCTIONS

Installation Instructions

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

1F98EZ-1421, Easy Install

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

ICM 275. Replacement Description

INSTALLATION INSTRUCTIONS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

Otherwise, you can continue reading the file on the following pages.

Heat Pump Defrost Board Replacement Kit

KM-630MAH KM-630MWH KM-630MRH

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioners

for combining TwO gas furnaces for PARAllel OPeRATIONs using The Rccl-cOIl (heating ANd AIR conditioning)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Reliability is a beautiful thing TM MODULAR CRESCENT CUBER KM-500MAH KM-500MWH KM-500MRH SERVICE MANUAL

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

SERVICING S-15 CHECKING CAPACITOR

INSTALLATION INSTRUCTIONS R 410A Split System Air Conditioner

Installation Instructions

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD

Installation Instructions

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Installation Instructions

Part 3 Troubleshooting

Model 1730A Compact Dehumidifier Installation Instructions

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Installation Instructions HEAT COOL FAN POWER

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS

KM-61BAH KM-101BAH KM-151BAH

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Product Information and Technical Guide

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

CW-5000/5200 Series Industrial Chiller maintenance manual

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Wiring Diagrams Units Produced After April 20, 2009

ERROR CODES R22 & R407C Units Black = All Units Red = 4, 5, 6 & 7 Series Blue = 8 Series Green = KX / KX2 / KXR

Installation Instructions

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Operator: Save these instructions for future use!

Hoshizaki America, Inc.

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

NDS Installation Manual

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

OPERATION AND SERVICE for

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

INSTALLATION INSTRUCTIONS R-410A Split System Air Conditioner

38TKB Air Conditioning Unit Installation and Start-Up Instructions

B SERIES ELECTRIC FURNACE

INSTALLATION INSTRUCTIONS Fan Coils FCM4X24-60

G Series Geothermal Indoor Split Heat Pump R-410A Refrigerant 2-6 Tons Single Speed 2-6 Tons Dual Capacity

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

BasicTroubleshooting Information and Guidelines

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

wiring diagrams AIR-COOLED CONDENSING UNITS SPLIT-SYTEM HEAT PUMP UNIT UNITS PRODUCED AFTER SEPTEMBER 1996 DIAGRAM INDEX

Marvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only

SCE170 SERVICE PARTS

A/C-HEATER SYSTEM - MANUAL

INSTALLATION INSTRUCTIONS R 410A Split System Heat Pumps

Premier 2-Zone Controller model Installer Guide

FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

Beverage Air IMPORTANT

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

HPXA19. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

Transcription:

Installation Instructions / User s Manual NAXA00101DB ommunicating Daughter Board The NAXA00101DB daughter board control allows for using 4 existing thermostat wires in an existing, finished home to communicate with the TSTAT0406 & TSTAT0407 thermostats. The daughter board translates the communicated heating and cooling needs and sends the normal discrete thermostat outputs to the indoor and outdoor equipment as needed. The NAXA00101DB Daughter Board must be used in conjunction with the TSTAT406 or TSTAT0407 ommunicating Thermostat for proper operation. The daughter board provides a two-wire RS485 ModBus communication link and 24VA to the communicating thermostat via a 4 wire connection scheme, input from the omfort Alert Module, a sensor input for the remote outdoor sensor, seven thermostat 24VA outputs (W,G,Y,O,W2,Y2,H) and status & communication ED s. NAXA00101 Daughter Board Kit includes the following: NAXA00101DB Daughter Board 4 - # 6 sheet metal mounting screws Input Pigtail wire harness & wire nut Remote outdoor sensor pigtail wire harness & wire nuts Installation instructions OD Y2 W2 H Y G W NAXA00101DB 1164-402 0735 O Y2 W2 H - Y G W O Note: Output ED s illuminate next to corresponding outputs in areas shown by International omfort Products, Inc. 1

Daughter Board Terminals & onnections See wiring diagrams for proper wiring and installation. The following connections are provided in the P2 terminal block: (Power and ommunication onnections to ommunicating Thermostat) P2 - Pin 1 "R" 24VA hot power connection for communicating thermostat P2 - Pin 2 "GND" Ground connection for communicating thermostat P2 - Pin 3 DX+ DX+ connection to the A+ Terminal on the communicating thermostat P2 Pin 4 DX- DX- connection to the B- Terminal on the communicating thermostat The following connections are provided in the P3 terminal block: (Outputs to the HVA Equipment) P3 Pin 1 O 24 VA thermostat output P3 Pin 2 W 24 VA thermostat output P3 Pin 3 G 24 VA thermostat output P3 Pin 4 Y 24 VA thermostat output P3 Pin 5 Not Used 24 VA thermostat output The following connections are provided in the P4 terminal block: (Outputs to the HVA Equipment) P4 Pin 1 H 24 VA thermostat output P4 Pin 2 W2 24 VA thermostat output P4 Pin 3 Y2 24 VA thermostat output P4 Pin 4 R 24 VA system power input P4 Pin 5 24 VA system common input The following connections are provided in the P5 onnector: (Optional ocation for the Outdoor Sensor Hook-up) P5 Pin 1 OD Ground for Remote Outdoor Temperature Sensor P5 Pin 2 OD Remote Outdoor Temperature Sensor input P5 Pin 3 Not used P5 Pin 4 Not used The following connections are provided in the P8 onnector: (Optional onnection for the omfort Alert AARM Output) P8 Pin 1 Not Used ----- No onnect---- P8 Pin 2 Not Used No connect P8 Pin 3 fault input from omfort Alert Module Status ED Operation The ED labeled ED5 is a status ED that will provide a heart beat blink of this ED to indicate that the NAXA00101DB communicating daughter board control is powered and working properly. ommunication ED Operation The ED labeled ED3 will be illuminated for 100mS each time a successful communications packet is received from the TSTAT0406 or TSTAT0407 communicating thermostat. Thermostat all Output ED s Operation There is an ED Output for each thermostat output from the daughter board. The corresponding ED will illuminate any time the associated thermostat output is active. ED 8 illuminates when O Output is energized ED 7 illuminates when W Output is energized ED 6 illuminates when G Output is energized ED 4 illuminates when Y Output is energized ED 9 illuminates when H Output is energized ED 1 illuminates when w2 Output is energized ED 2 illuminates when Y2 Output is energized International omfort Products, Inc. 2

Input from omfort Alert Module to Daughter Board The omfort Alert Module will transmit the active fault code. The omfort Alert or thermostat does not have any effect on operation of the equipment during a omfort Alert fault. The omfort Alert fault output can be wired directly to the daughter board or communicating thermostat. When the omfort Alert Module is wired to the input of the daughter board, it will recognize the fault output after it has been active for 10 seconds. After the daughter board has recognized the active fault from the omfort Alert Module, the daughter board will forward the fault information to the communicating thermostats via the communication wires. The communicating thermostat will then display the fault code as defined. OMFORT AERT MODUE FAUT ODES Status ED Status ED Description Status ED Troubleshooting Information Green POWER Module has power Supply voltage is present at module terminals Red TRIP Thermostat demand signal 1. ompressor protector is open Y is present, but the heck for high head pressure compressor is not running. heck compressor supply voltage 2. Outdoor unit power disconnect is open 3. ompressor circuit breaker or fuse(s) is open. 4. Broken wire or connector is not making contact 5. ow Pressure switch open if present in system 6. ompressor contactor has failed open. Flash ode 1 Flash ode 2 Status ED Flash ode 3 Flash ode 4 Flash ode 5 Flash ode 6 ong Run Time ompressor is running extremely long run cycles System Pressure Trip Discharge or suction pressure out of limits or compressor overloaded Status ED Description Short ycling ompressor is running only briefly ocked Rotor Open ircuit Open Start ircuit 1. ow refrigerant charge 2. Evaporator blower is not running heck blower relay coil and contacts heck blower motor capacitor heck blower motor for failure or blockage heck evaporator blower wiring and connectors heck indoor blower control board heck thermostat wiring for open circuit 3. Evaporator coil is frozen heck for low suction pressure heck for excessively low thermostat setting heck evaporator airflow (coil blockages or return air filter) heck ductwork or registers for blockage 4. Faulty metering device heck TXV bulb installation (size, location and contact) heck if TXV/fixed orifice is stuck closed or defective 5. ondenser coil is dirty 6. iquid line restriction (filter drier blocked if present in system) 7. Thermostat is malfunctioning heck thermostat sub-base or wiring for short circuit heck thermostat installation (location, level) 8. omfort Alert Module failure 1. High head pressure heck high pressure switch if present in system heck if system is overcharged with refrigerant heck for non-condensable in system 2. ondenser coil poor air circulation (dirty, blocked, damaged) 3. ondenser fan is not running heck fan capacitor heck fan wiring and connectors heck fan motor for failure or blockage 4. Return air duct has substantial leakage 5. If low pressure switch present in system, check Flash ode 1 information Status ED Troubleshooting Information 1. Thermostat demand signal intermittent 2. Time delay relay or control board defective 3. If high pressure switch present, go to Flash ode 2 information 4. If low pressure switch present, go to Flash ode 1 information 1. Run apacitor has failed 2. ow line voltage (contact utility if voltage disconnect is low) 3. Excessive liquid refrigerant in compressor 4. ompressor bearings are seized Measure compressor oil level 1. Outdoor unit power disconnected 2. ompressor circuit breaker or fuse(s) open 3. ompressor contactor has failed open. heck compressor contactor wiring and connectors heck for compressor contactor failure (burned, pitted or open) heck wiring and connection between supply and compressor heck for low pilot voltage at compressor contactor coil 4. High pressure switch is open and requires manual reset 5. Open circuit in compressor supply wiring or connections 6. Unusually long compressor protector reset time due to extreme ambient temperature 7. ompressor windings are damaged 1. Run capacitor has failed 2. Open circuit in compressor start winding or connections ompressor start winding is damaged Flash ode number corresponds to a number of ED flashes, followed by a pause then repeated. TRIP and AERT ED s flashing at the same time means control circuit voltage is too low for operation. Flash ode 7 Flash ode 8 Flash ode 9 Open Run ircuit urrent only in start circuit Welded ontactor ow Voltage ontrol circuit < 17 VA 1. Open circuit in compressor run wiring or connections heck wiring and connectors between supply and the compressor R terminal 2. ompressor run winding is damaged 1. ompressor contactor has failed closed 2. Thermostat demand signal not connected to module 1. ontrol circuit transformer is overloaded 2. ow line voltage (contact utility if voltage at disconnect is low) heck wiring connections International omfort Products, Inc. 3

1 STAGE A WITH 1 STAGE FANOI DAUGHTER BOARD TO FANOI TO GENERI A WIRING (REFER TO UNITS I/O MANUA FOR SPEIFIS) 1 STAGE A WITH VARIABE SPEED FANOI + 2 STAGE EETRI 2 STAGE A WITH VARIABE SPEED FANOI + 2 STAGE EETRI THERMOSTAT DAUGHTER FANOI A THERMOSTAT DAUGHTER FANOI A THERMOSTAT DAUGHTER FANOI A W2 W2 W2 W2 W2 W2 W2 W1 W W W1 W W1 W1 W W1 H H H H H H H O/B O/B O O/B O Y2 Y2 Y1 Y2 Y/Y2 Y/Y2 Y2 Y1 Y Y Y Y1 Y Y/Y2 Y Y1 Y Y1 Y1 1 STAGE HP WITH 1 STAGE FANOI + 1 STAGE EETRI DAUGHTER BOARD TO FANOI TO GENERI HP WIRING (REFER TO UNITS I/O MANUA FOR SPEIFIS) 1 STAGE HP WITH VARIABE SPEED FANOI +2 STAGE EETRI 2 STAGE HP WITH VARIABE SPEED FANOI + 2 STAGE EETRI THERMOSTAT DAUGHTER FANOI HP THERMOSTAT DAUGHTER FANOI HP THERMOSTAT DAUGHTER FANOI HP W2 W2 W2 W2 W2 W2 W2 W2 W1 W W W2 W1 W W1 W2 W1 W W1 W2 H H H H H H H O/B O/B O O/B O/B O O O/B O/B O O Y2 Y2 Y1 Y2 Y/Y2 Y2 Y1 Y Y Y Y1 Y Y/Y2 Y Y1 Y Y1 Y Notes: The "" Output from the Heat Pump or A/ Unit can be wired to either the NAXA00101DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. The Outdoor Sensor can be hooked directly to the NAXA00101DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. A pigtail wiring harness is supplied with the NAXA00101DB Daughter Board for connection to its "" input. A pigtail wiring harness is supplied with the NAXA00101DB Daughter Board for connection to its "OD" inputs. DAUGHTER BOARD TO FURNAE TO GENERI A WIRING (REFER TO UNITS I/O MANUA FOR SPEIFIS 1 STAGE A WITH 1 STAGE FURNAE 1 STAGE A WITH VARIABE SPEED FURNAE 2 STAGE A WITH 2 STAGE VARIABE SPEED FURNAE THERMOSTAT DAUGHTER FURNAE A THERMOSTAT DAUGHTER FURNAE A THERMOSTAT DAUGHTER FURNAE A W2 W2 W2 W2 W2 W2 W2 W1 W W W1 W W1 W1 W W1 H H DEHUM H H DEHUM H H DEHUM O/B O/B O O/B O Y2 Y2 Y1 Y2 Y2 Y/Y2 Y2 Y1 Y Y Y Y1 Y Y/Y2 Y Y1 Y Y1 Y1 * 8MPV* "" SERIES OR NEWER *8MPV* "" SERIES OR NEWER * 9MPV* "D" SERIES OR NEWER *9MPV* "D" SERIES OR NEWER DAUGHTER BOARD TO FURNAE TO GENERI HP WIRING (REFER TO UNITS I/O MANUA FOR SPEIFIS 1 STAGE HP WITH 1 STAGE FURNAE 1 STAGE HP WITH VARIABE SPEED FURNAE 2 STAGE HP WITH 2 STAGE VARIABE SPEED FURNAE THERMOSTAT DAUGHTER FURNAE HP THERMOSTAT DAUGHTER FURNAE HP THERMOSTAT DAUGHTER FURNAE HP W2 W2 W2 W2 W2 W2 W2 W1 W W W2 W1 W W1 W2 W1 W W1 W2 H H DEHUM H H DEHUM H H DEHUM O/B O O O/B O O O O/B O O O Y2 Y2 Y1 Y2 Y2 Y/Y2 Y2 Y1 Y Y Y Y1 Y Y/Y2 Y Y1 Y Y1 Y * 8MPV* "" SERIES OR NEWER *8MPV* "" SERIES OR NEWER * 9MPV* "D" SERIES OR NEWER *9MPV* "D" SERIES OR NEWER Notes: The "" Output from the Heat Pump or A/ Unit can be wired to either the NAXA00101DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. The Outdoor Sensor can be hooked directly to the NAXA00101DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. A pigtail wiring harness is supplied with the NAXA00101DB Daughter Board for connection to its "" input. A pigtail wiring harness is supplied with the NAXA00101DB Daughter Board for connection to its "OD" inputs. International omfort Products, Inc. 4

NAXA00101DB Drill Template Directions: 1. ut Template out along dotted lines. 2. Tape template over the sheet metal area to be drilled. 3. Drill four holes using a #32 drill bit (.1160 ) through the four dark circles denoted on the template. 4. Remove the template from the drilled area. 5. Mount the NAXA00101DB ontrol with the four #6 sheet metal screws included in the kit. Note: - Ensure that are to be drilled is clear of any gas lines or wiring harnesses prior to drilling. Drill Holes 2 places Drill Holes 2 places International omfort Products, Inc. 5