HYBRID PLUS2 AIRCOOL VENTILATORS

Similar documents
HYBRID PLUS2 AIRCOOL VENTILATORS

ACTIVE VENTILATION SYSTEMS

INTELLIGENT VENTILATION CONTROLS NATURAL AND HYBRID PLUS SYSTEMS

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

INTELLIGENT VENTILATION CONTROLS: NATURAL AND HYBRID SYSTEMS

VENTILATION DESIGNED FOR CARE HOMES

NATURAL VENTILATION CONTROL SYSTEMS

CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS...

The Glidevale range of Fresh wall

External insulated volume. control damper

Eco Active H E A T R E C O V E R Y S Y S T E M S H Y B R I D U N I T. W: T:

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

i PSV WHOLE-HOUSE VENTILATION SYSTEM

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

CONDOR. Supply air ceiling QUICK FACTS

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Domestic & Commercial Fans

Polaris-I-60. active chilled beam. the future of space conditioning

NATURAL AND ENERGY-EFFICIENT VENTILATION SYSTEMS FOR DOMESTIC BUILDINGS

Ceiling diffusers. Type DLQL

Typical Operating & Maintenance Manual for SOLA-BOOST X-Air Project Name

air handling units AT THE LEADING EDGE OF AIR FLOW

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Solutions brought to you by Hurlstones. Solutions brought to you by Hurlstones. shower panel specification manual 2012

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Ceiling air diffuser INDULTHERM INDULTHERM-e

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Regulations covering Heating and Ventilation equipment in Schools

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Energy Recovery, Wholehouse Ventilation ECO LIVING

Air distribution for clean rooms. Clever and flexible.

shower panel specification manual 2008

Innovative solutions for air and climate technology. Air handling Climate ceilings Air distribution technology Fire safety products Chilled beams

Specifying the Right Rooflight. T: +44 (0) E:

AXIOM L CANOPY Installation Guide

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

Introducing the RetroVent

L411:P43 D11:X421. CI/SfB. (31 5) Xh4

COOLflow 4E PRODUCT RANGE

Sargasso Range. A new range of radiant panels for heating commercial applications

The Bilco Company has partnered with industry pioneer Colt to bring dual purpose natural and smoke ventilation products to North America.

TOSHIBA AIR CONDITIONING

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Units for suspended cei lings

Perimeos. Ceiling Recess. decor. systems

Assigning profiles to a Breathing Buildings NVHR Unit (NVHR900 & NVHR1100)

Fan Coil Unit CULTRA

Units for suspended ceilings

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

Recessed. Air Curtain. Fig 1. Recessed air curtain

System architecture. Air treatment Index

42AM. Air heaters PRODUCT SELECTION DATA

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Machine guarding. First Choice Solutions for Machine Guards.

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Waterborne Climate Systems

Technical Bulletin 005(B) Developed with Building Standards Scotland

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

ventilation 3 AERO is the solution for the right The window ventilator range for intelligent, controlled ventilation.

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Whole Home Heat Recovery Ventilation

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

Hybrid Thermal Mixing Ventilation Systems

Healthy, comfortable and energy-efficient ventilation

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

TopVent Design Handbook

Uniclass L7535: N3253 EPIC L13:Y42. CI/SfB (57) X (K5) Residential Smoke Ventilation

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Double Skin Air Handling Units

LTV - LTV-N Air Handling Unit

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser

About Smart. Expand your horizons with our high-quality sliding and slide-folding doors

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Ceiling swirl diffusers

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

DucoSlide. Architectural solar shading ARCHITECTURALE ZONWERING. Natural comfort. A wide range of louvre blades. Maximum degree of privacy

Ceiling swirl diffusers

Short Form Ventilation Product Guide

PERGOLA SUNEAL THE MULTI-SEASON LIVING SPACE. Architects: Giusti/Versini Photography: Laurent Descloux

Photography: Wenzel SHOP AND OFFICE FITTINGS TECHNAL SYSTEM AND FURNITURE

TEAM DESKS range guide. v 1 / Fraternity

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

Transcription:

NEW PRODUCT CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 February 2018 HYBRID PLUS2 AIRCOOL VENTILATORS................................

........................................................ HYBRID PLUS2 AIRCOOL VENTILATORS.......................................................................... The Hybrid Plus2 Aircool ventilator combines the features of the Aircool ventilator with an innovative air tempering and mixing unit utilising a single energyefficient fan. It has been primarily designed to be used in a single-sided ventilation strategy and to meet the requirements of the Facilities Output Specification for Priority Schools Programme Phase 2, the forthcoming Building Bulletin 101, Guidelines on ventilation, thermal comfort and indoor air quality in schools and Building Bulletin 93, Acoustic design of schools: performance standards. The system has been developed to provide a simple cost-effective solution for specifiers and main contractors. With a focus on indoor air quality and thermal comfort, the Hybrid Plus2 Aircool is the ideal product to incorporate into schools and other educational buildings. Air quality and thermal comfort Heating and cooling are important in maintaining a comfortable indoor environment, together with the provision of good air quality and the removal of pollutants, especially important in maintaining CO 2 levels to below 1,500ppm. The primary aim of a ventilation system is to ensure that there is air movement throughout the building, circulating air so that it does not become stale and ridding the building of pollutants by bringing fresh air in and taking stale air out. BENEFITS Contemporary design. Quiet operation leads to less disturbance when in use. Sensors respond automatically to rising levels of CO 2. Enables Facilities Output Specification for Priority Schools Programme, BB101 and BB93 to be achieved. Each unit can ventilate a room containing up to 16 occupants. Modular format enables flexible design. Versatile mounting options to accommodate wall, curtain walling and windows. Three modes of operation to satisfy cool and warm conditions. Lightweight construction for easy lifting and positioning. Three-component design for speedy installation. Energy efficient fan resulting in lower running costs. The Hybrid Plus2 Aircool system can provide ventilation up to 145 l/s via the fan operation offering an energy-efficient means of maintaining thermal comfort in a free running building. The mixing of fresh air with internal room air is an integral part of the design of the unit which reduces the risk of cold draughts during cooler periods. Effective and intelligent control of the ventilator is critical to maximising its performance. A Passivent ic8000 controller, internal CO 2 and temperature sensors and also an external temperature sensor are used with intelligent software to determine the different operating modes and ensure automatic, optimum thermal comfort and indoor air quality. The ic8000 controller can work in conjunction with other building services such as the heating system and can be integrated through a building management system...........................................................................

................................................................................................................................................................................................................................. Exceptional design Slim and sleek The unit is one of the slimmest in its class due to its unique internal design. Its aesthetic, contemporary look and flexible design means that it can be mounted exposed or, if preferred, within a bulkhead. Versatile It can be fitted to external facades, including all forms of wall construction, curtain walling and window profiles. Quiet The ventilator utilises silent, controllable insulated dampers from the Aircool range. The system can be used to meet the acoustic requirements of BB93. weather louvre Energy efficient Thanks to the energy-efficient fan and the ultra-energy-efficient passive mode, power consumption is kept to a minimum. Scalable One unit can accommodate up to 16 occupants. The addition of a second unit can accommodate up to 32 per room. Hybrid Plus2 Aircool mixing unit wall sleeve................................................................................................................. 3

............................................................................ HYBRID PLUS2 AIRCOOL VENTILATORS.............................................................................................. Designed for fast and simple installation Flexible - can be positioned within the space, either on display or within a suspended ceiling or bulkhead (requiring additional grilles and ducts). Fast - three-component system makes for speedy installation. Lightweight - easy to lift into position. Easy maintenance - access panel for inspection. Simple fixings - straightforward installation via four drop down bolts. Secure - no external fixings on louvre. Performance Equivalent free area of each unit: 0.054m 2. Max. flow rate when inlet & outlet resistances are equal and fan is in operation: 145 l/s. Compliance: Building Bulletins 93 & 101. Appearance External louvres and frame are polyester powder coated to order. Internal cover grilles are supplied in white RAL 9016 as standard but can be polyester powder coated to other colours to specific order. Dimensions Internal tempering and mixing unit: 967mm(w) x 330mm(h) x 1253mm(d). Aircool size would be supplied to suit the building requirements: typically 842mm(w) x 320mm(h). Weight: approximately 30kg. Specification clause Hybrid Plus2 Aircool, incorporating Aircool ventilator with a mixing chamber. Aircool for masonry walls/windows/ curtain walls* having extruded aluminium frame, extruded aluminium external weather louvres, 4mm black polypropylene insect screen. Insulated motorised controllable dampers fabricated from double skin of aluminium with ABS thermal break and blade compression seals. Mixing chamber finished to RAL 9016 white, incorporating variable speed fan, controllable mixing dampers. weather louvre wall sleeve Hybrid Plus2 Aircool mixing unit Sectional drawing of the unit within a wall strategy Ventilator U-value 0.86W/m²K when closed. 24V modulating actuator control for dampers, controlled by Passivent ic8000 intelligent controller. Fan flow rate of up to 145 l/s. Ventilators designed and manufactured under BS EN ISO 9001, and supplied by Passivent, North Frith Oasts, Ashes Lane, Hadlow, Kent TN11 9QU. Tel: 01732 850770, email: projects@passivent.com. *Delete as applicable. Ventilation performance The graph opposite shows the varying ventilation conditions during modes 1 and 2 of the system. When there is a requirement for a low volume of air flow due to air quality, but with the need to maintain thermal comfort in the room, the system operates in mode 1 (mixing). As the ventilation conditions change, the system adapts to a mode 2 (cooling) operation where the emphasis switches to increasing air flow and reducing the room temperature. High Volume air flow Low Mode 1 - mixing Fan speed Volume flow Mode 2 - cooling Mixing requirement.............................................................................................. 5 High Recirculated air Mixing Fresh air

................................................ OTHER PRODUCTS.................................................................. Passivent offers a range of other ventilation products including: SoundScoop acoustic transfer ventilation products. Roof ventilation terminals incorporating Airstract, Airscoop and combined rooflights / ventilators. Ventilation control systems. imev intelligent mechanical extract ventilation systems.................................................................... PASSIVENT North Frith Oasts, Ashes Lane, Hadlow, Kent TN11 9QU Tel: 01732 850770 Fax: 01732 850949 Email: projects@passivent.com Web: www.passivent.com Passivent maintains a policy of continuous development and reserves the right to amend product specifications without notice. A division of Building Product Design Ltd. Company Registration No; 3944123...... 910036 February 2018 4772 ISO 9001 OHSAS 18001