Remote Display Alarm Indicator for Oxygen monitor

Similar documents
Universal Gas Detector

Air Check O 2 Sample Draw Monitor

Air Check O 2 Sample Draw Monitor

Air Check O 2 Deficiency Monitor 0-25%

Air Check Ex O 2 Deficiency Monitor

Air Check O 2 Remote Monitor 25%

Air Check O 2 Deficiency Monitor 0-25%

PureAire Combo O 2 / CO 2 Monitor

Air Check O 2 Deficiency Monitor

Air Check Advantage Acrylonitrile Monitor

GLD-30 Gas Leak Detector

INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Two-Channel Gas Controller

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Product Manual SZ1145

Product Manual SZ1144

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Pioneer-R16 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual

Analog Room Pressure Monitor RPC Series

Product Data Sheet. Remote Terminals. Features:

DYGIZONE GJD910 Lighting Controller & Enunciator

Air Check EX LEL Gas Monitor Instruction Manual

Dual Input Toroidal Analyzer

Dual Input ph/orp Analyzer

Addendum for STI-6406 with Dual Access Control

Combustible Gas Detection and Control System

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Model STX-PA Gas Monitor

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

INSTALLATION INSTRUCTIONS

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Exit Stopper. STI-6400 Series

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

DC 60 & DM 60 displays

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Conventional Fire Alarm System 2014 V1.2

Refrigerated air dryers

EC Series Wall Unit Humidifier

Mark 25 Ultrapure Water Conductivity Analyzer

IMR IX176 Portable Gas Detector User Manual

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Exit Stopper. STI-6400 Series

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

INSTALLATION & USER MANUAL

Detection, Protection, Innovation

Dual Input ph/conductivity Analyzer

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

GAS PLUS ALARM SYSTEM

3M Oldham MX 43 Controller

Flostop TS D7E and A8E. Operation Manual

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Macurco DVP-120 Detection and Ventilation Control Panel

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

Instruction Manual WARNING

Controllers. Instruction Manual WARNING

Beacon 410A Gas Monitor Operator s Manual

Carbon Monoxide Transmitter

T8411R Electronic Heat Pump Thermostat

SP-1000X. Panic Device Power Controller Installation Guide. Rev

380 SERIES REMOTE SIREN ETSA380R

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

BRASCH MANUFACTURING COMPANY, Inc.

Inc Series Digital Gas Detector/Controller. Operation Manual

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

Planning Elevator Relay Groups Programming Millenium for Windows Software

QUADRANT OPERATION and MAINTENANCE MANUAL

Dryer Moisture Systems Inc. Dryer Master GM 2. Product Manual. Revision 1.0 January, 2007 Revision 1.01 March, Prepared by:

Electro-Sentry. Users Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Heating Cable. Description

Beacon 110 Gas Monitor Operator s Manual

Version Inc Series Digital Gas Detector/Controller. Operation Manual

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Instruction Manual August sitrans CU 02

780 Keypad Demonstrator Module

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use

Universal Transmitter. Operations & Maintenance Manual

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Transcription:

Remote Display Alarm Indicator for Oxygen monitor (Part number 99091) The Remote Display Alarm Indicator is designed to display remote oxygen concentration information from PureAire oxygen monitors. All PureAire O 2 monitors have a built in 4-20mA output. The remote display alarm easily connects to the monitor s input power and ma output connection. An 18 AWG, three conductor, shielded control and instrumentation cable, Belden 8770 or equivalent is recommended for the connection. The maximum permissible cable length is 250 feet. You can simultaneously connect one remote display to one Air Check Oxygen monitor and one programmable logic controller, PLC. PureAire Monitoring Systems, Inc. 1140 Ensell Road Lake Zurich, Illinois 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 pureairemonitoring.com

How to mount the Remote Display Alarm Indicator 1) Open the two side doors to expose the front panel screws. 2) Loosen the 4 screws to separate the front panel from the case. Mount the case to a wall or other flat surface. There are 4ea. through holes for fastening the case. The case is designed to be flush mounted. NOTE: The front cover can be removed from the case by gently pulling on the plastic hinges. (they will stay connected to the front cover. To connect the front cover, just push the plastic hinge into the case.

How to wire the Remote Display Alarm Indicator Ground and shield are tied together 24VDC Power Supply ma 18 AWG, three conductor, shielded control and instrumentation cable, Belden 8770 or equivalent Max distance 250 feet When connecting to PLC, remove jumper and connect MA to PLC+ and SHIELD to PLC-. Do not remove jumper unless connecting to PLC. CAUTION: Make all wire terminations with the power OFF. Failure to do so can damage the oxygen monitor and remote display and void your warranty. Identification of and controls 1. Alarm Adjusting Switches These are used select the alarm level to be adjusted. They are factory set at 19.5% for Alarm 1 and 18% for Alarm 2. (Normally set at the factory) 2. Alarm Polarity Switches These are used to select when the alarms will activate. For oxygen the alarm are set for Below. If the readings go below ambient, 20.9% then the internal horn and LED s will activate. When used with our toxic gas monitors, the polarity is set to Above. (Normally set at the factory) 3. Range Auto Adjustment Switches These are used to adjust the zero and full scale reading on the Remote Display Alarm Indicator. When sending a 4mA and 20mA

signal from your oxygen monitor, pushing these will automatically adjust the zero and full scale readings on the Remote Digital Display. 4. Alarm Adjusting Buttons These buttons are used to increase, (UP) or decrease (DOWN) the alarm settings. 5. Horn On/Off Switch This switch is used to turn the internal audio horn on and off. In the On position, any alarm will activate the audible horn. To disable the internal horn, turn the switch to Off. 1. Alarm adjusting 2. Alarm Polarity Do not remove jumper unless connecting to PLC. 4. Alarm adjusting buttons 5. Horn On Off Switch 3. Range auto adjustment How to Setup and Operate the Remote Display CAUTION: Entering the set up menus will disable the real time oxygen readings After wiring the remote display to your Oxygen monitor, turn on the power to your oxygen monitor. During the warm up the remote display will illuminate a yellow fault LED and the display will read FLt, (indicating that the oxygen monitor is in fault). This will clear after the oxygen monitor completes the 4 minute warm-up. During warm up After warm up

How to set the zero and full scale range This will need to be set up in the field to adjust to the length of cable between the oxygen monitor and the remote display alarm indicator. To perform this in the field, first enter the password on your oxygen monitor and select the Set 4-20mA loop menu Push the joystick right to select Set 4mA Zero and then push the joystick right one more time to activate it. This sends a 4mA signal to the remote display. On the back of the remote display push the ZERO button for 3 seconds. You ll see the display reset and automatically adjust itself to the new zero. If necessary, you can push the joystick up or down to fine tune the zero reading. NOTE: Both AL1 and AL2 LED s will also be illuminated. (To exit the Zero menu, push the Joystick left once) Push the joystick down once to select Set 20mA Span and then push the joystick right one more time to activate it. This sends a 20mA signal to the remote display. On the back of the remote display push the SPAN button for 3 seconds. You ll see the display reset and automatically adjust itself to the new span of 25%. If necessary you can push the joystick up or down to fine tune the full scale reading once) To return the main menu, push the Joystick left until the monitor scrolls Oxygen 0-25% on the top line. NOTE: To fine tune the reading to match the reading on the oxygen monitor, use the Set 20mA Span menu. Push the joystick up or down until both displays match. CAUTION: If the oxygen monitor is in the measuring mode and the ZERO push button is pressed an Err will be displayed on the remote display and no readings will be recorded. If the SPAN push button is pressed in the measuring mode, the remote display will automatically adjust to 25.0%. You will need to repeat the above adjustment procedure again for the remote display to mirror the oxygen monitor. NEVER PUSH THE SPAN in the measuring mode. How to set the internal alarms on the Remote Display The Remote Display has two user selectable alarms with a separate horn tone to identify Alarm 1 from Alarm 2. Both are preset at the factory; AL1 = 19.5% and AL2 = 18%. They can be changed in the field. To set Alarm 1, Press Alarm 1 for two seconds to enter the alarm change mode. The display will show the current alarm setting and the right most decimal point will be lit. Use the UP or DOWN buttons to increase or decrease the alarm value. When done, push the Alarm 1 button for 2 seconds to get back to the monitoring mode. To set Alarm 2, Press the Alarm 2 button for two seconds to enter the alarm change mode. The display will show the current alarm setting and the left most decimal point will be lit. Use the UP or DOWN buttons to increase or decrease the alarm value. When done, push the Alarm 2 button for 2 seconds to get back to the monitoring mode.