Using the Model 1500 Portable Chilled Mirror Hygrometer

Similar documents
Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Using the DewTrak II Dew Point/ Humidity Transmitter

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

HYGROPHIL H process hygrometer

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

Rev B, 9/2/2009. Kodiak Chiller Overview

Sitron s CF Line of Flow Switch Monitors

Dew-Point Transmitters and Instruments

PUV, PIR and PFO Series BROCHURE

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

DP 300 mobile dew point instrument

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Temperature Sensors & Compression Seal Fittings

OptiCal Humidity and Temperature Calibrator User s Manual

RLD-H10P Refrigerant Leak Detector

Model OEM-2 INSTRUCTIONS FOR USE

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Moisture and Hydrocarbon Dew Point Measurement

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

PDM 75 Portable Hygrometer OPERATORS MANUAL

SDR Dry Room. Outstanding performance

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

User s Guide. RHCL-2 Portable RH/Temperature Calibrator. Shop online at omega.com

Inductive Conductivity

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Relative Humidity Transmitters

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Optidew & Optidew Vision High Performance Optical Dew-Point Transmitter User s Manual

Moisture and Hydrocarbon Dew-Point Measurement

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Temperature Sensors & Compression Seal Fittings for Semiconductor Processing

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

TDS Conductivity Probe In-Line conductivity measurement

Membrane Technologies DMD Series Dryers ESM Series Dryers

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

CMMD Series Membrane Air Dryer

HEATLESS DESICCANT AIR DRYERS

Safety vacuum drying oven for flammable solvents

Hydrazine Analyzer Series 2171 Specifications

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

BINDER Scientific Product Catalog

portable gas analyser

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN. Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION

Type 300 Series Electrode Stabilization Ovens

Duct Humidity/Temp Sensor

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web:

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

VD 53 - Vacuum drying oven for non-flammable solvents

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

Cabinet Cooler Systems

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Electronic Flow Switches

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Arctica Solar 1500 Series Heater Installation Manual

Thermohygrometer with Single Type K Input and Superheat Function

Mark 25 Ultrapure Water Conductivity Analyzer

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

HIGH RANGE DIGITAL DEW POINT METER & MONITOR Model #8074 IMS # (TED1-8074)

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

MODEL 421 NUCLEAR POWER PLANT TRITIUM MONITOR

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Model gffoz Process Ozone Sensor (In-Line)

Accessories, interfaces, sensors and complete solutions.

Benefits & Technology for Decentralizing a -40 F Dew Point

RS Pro Infrared Temperature Sensor

TOOLS AND INSTRUMENTS

SS-100. Pyrometer. Temperature Range: 800~2400

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

DESCRIPTION MODEL 1205/1205HA NOTE

PORTABLE DEW POINT MONITOR

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

RLD-H10G Refrigerant Leak Detectors

Transcription:

APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately measure the moisture content in gases. It offers precision dew point measurement in a robust, transportable carrying case. The Model 1500 uses the chilled mirror (CM) dew point temperature condensation principle to determine the water vapor concentration in gas mixtures, and a precision platinum resistance thermometer to measure the mirror temperature. The CM uses a thermo-electric chiller to control the temperature of the chilled mirror. Since it is a direct measurement of dew point and thus a Primary Standard Measurement Technique, the Model 1500 is highly regarded by calibration technicians and manufacturing facilities for its portability, accuracy, quick dry down, fast response and long life. The Model 1500 may be fitted with a precision air temperature sensor (needed to determine RH), pressure transducer, and a wide range of either local or remote chilled mirror sensors. Three main types of chilled mirror sensors are available for the 1500: the remote mounted D-Probe featuring a two stage air cooled chilled mirror. The S-Series sensor- available in both local and remote mount configurations. Depending on the desired measurement range, the S-Series sensor is available in Two or Three stage chilled mirror configurations. To accommodate different cooling thresholds, the S-Series sensor may be air cooled, fan cooled or liquid cooled. In contrast, the D-Probe is only available as a Two-Stage chilled mirror. But since it is configured as a probe, it may be used in a wide array of applications including ambient air monitoring, insertion into glove boxes, HVAC ducts, environmental test chambers, circulation pipes, refrigerated storage rooms, engine test filter rooms, The new X3 Chilled mirror has recently been configured to operate within the model 1500 platform. The X3 is available in several models and offers the USER chemical resistance to aggressive background gases, fast response time and ability to measure very low dew point limits without the need for liquid cooling. Please refer to the X3 brochure for more information. APPLICATIONS Troubleshooting Dryer Systems Diffusion Furnaces Product Drying Chambers Environmental Testing Food Packaging Medical Packaging Heat Treat/ Annealing Ovens Chemical Reactors Cylinder Refill Testing Fuel Cell Testing Compressed Air Systems Pharmaceutical Powder Drying Main: +1 (508) 263-5900. Fax:+1 (508) 486-9348 www.edgetechinstruments.com

Page1 The Model 1500 offers many standard features including: PRIMARY STANDARD MEASUREMENT: Chilled Mirror measurement technique NIST Traceable calibration certificate Automatic Balance Cycle (ABC) automatically re-standardizes and corrects for contaminants Choice of Analog Outputs (4-20 ma or 0-5 VDC) RS-232 Serial Interface Programmable electrically isolated alarm relay, 1 FORM C Integral Flowmeter for control and viewing sample flow 115/ 230 VAC Battery Recharger BENEFITS of the Edgetech Instruments Model 1500: Portable unit great for troubleshooting and convenient measurements The CM Sensor is a direct, Primary Standard measurement method, NIST traceable Improve your quality control: Excellent Precision and Stability Reduce Maintenance Costs: Chilled Mirror is robust, long Life with no moving parts Rapid dry-down time in comparison to other technologies Eliminate Scrap or Lost Time: Fast response in responding to upset process conditions. Sensor Notes/ Sampling Configuration Options 1. The D-probe is mounted (remote) tethered on a signal cable. 2. The S-series sensor can be mounted either local at the model 1500 or remote 3. The standard D-Probe is configured for diffusion sampling 4. The X3 sensor offers chemical resistance, fast response time and low dew point capability. 5. To measure an extracted flow of sample gas with the D-Probe, the optional flow through cover (SC) or the Sample Chamber (SC1) may be installed (includes fittings). 6. A precision air temperature probe is optional. Temperature can be used to calculate & display RH% 7. The integrated VP vacuum pump option may be used to extract a gas sample from the measurement point and direct it through the sensor @1-2 SCFH 8. An optional chiller may be used to obtain lower dew point readings when using the S-series sensors. 9. Optional Pressure transducers may be specified to compensate for sample pressure variation and Psychometric calculations. 10. The S-Series chilled mirror sensor are flow through sample gas design and are equipped with 1/4inch Swagelok fittings. Aluminum construction lends itself to most non-aggressive background gases. The S- Series do feature an option for Teflon Coating for additional chemical resistance. 11. The X3 body is constructed of 316SS and may be configured with Hastelloy or Teflon wetted materials. Inquire for pricing for the X3 inserts. 12. The S-Series sensors are equipped with a liquid chill port for the flow of chilled liquid to aid in cooling the TEC to allow for lower dewpoint. 13. The X-series sensors are designed as fan cooled or liquid cooled, but not both. The X3F and X3SF feature fans used for more efficient heat exchange of the TEC: hence lower DP with air cooling only. 14. The Standard D-Probe features air convection heat exchange.

Page2 TO ORDER THE Model 1500: a. Determine type of measurement: DewPoint, Relative Humidity, Pressure, Temperature. The AT temperature probe is required for Relative Humidity. If the sample pressure varies, you may want to consider the Pressure Transducer option that automatically corrects Dew Point reading. b. Determine the range of measurement and type of sensor: D-Probe, S-Series or X series. c. Determine if you need chemical resistance of the X3. d. Your application determines whether to select local mounted sensor(s) or remote e. The X3 and the S3 sensors require the base unit to be the 1500-AC. Otherwise, you may choose either the 1500-DC battery powered unit or the 1500-AC unit. 1. Select 1500 DC or 1500 AC based on the application and sensor type. 2. Select Sensor Type- D-probe (remote mount), S or X series (remote or local mount) 3. Select Mirror Type: Chrome (standard), Stainless Steel, Platinum 4. Select Local or Remote Sensor (typical is local) 5. If choosing the D-Probe, then select related options 6. Select Options such as temperature sensor, Pressure Transducer, RS232 serial interface,.. 7. List as separate line items additional choices such as Accessories, Calibration Packages,. 1500 - - - DC or AC SENSOR/ MIRROR OPTIONS For Ex: 1500-AC-S3-ATDM would be a 1500 VAC powered with S3 fan cooled CM sensor and air temperature probe. STEP 1: SELECT DC battery powered or AC vac powered: 1500-DC 1500-AC Battery Powered, includes charger, must add sensor and options VAC Powered, provided w/ power cord, must add sensor and options. (Use this model with the X or S series sensors) Additional Notes on configuring the model 1500: To help determine the best sensor for your application: 1. The target dew point range will help you determine the right sensor. Our D-Probe, S2 and S2SC sensors feature the two stage chilled mirror sensor for measuring dew points no lower than -40DP (in some instances this may require liquid cooling of the sensor depending on the temperature of the ambient air). The S3 and the X series sensors can measure lower dew points. The X3F and X3SF can measure very low dew points without the need for any liquid cooling. 2. If you intend to measure sample gas that may be corrosive or reactive, the best choice may be the X3 series since the standard design is resistant to most aggressive gases. 3. The X3 and S3 sensors require the 1500-AC because of the power requirements of the larger TECs. To help determine the best options for your application: 1. If the sample gas is positive pressure, then no special options required as long as the sample pressure does not exceed 300 psig. 2. If the positive pressure sample fluctuates, you may consider adding the pressure transducer option which can be set to automatically pressure compensate the dew point reading. 3. If you want to measure temperature (or if you want to measure RH%) you should add the AT temp probe. 4. If the sample pressure is at atmospheric or slightly negative pressure (no greater than -10mm Hg) then adding the vacuum pump option would be suitable for the application. 5. If using the D-Sensor insertion probe, you may choose different mounting configurations- see section 5

Page3 Chilled Mirror Dew Point Sensors for the model 1500 S-Type, Standard Duty Description Depression S2 Two Stage, Al Body, Convection Air Cooled- No Fans, Flow Through Sampling 60C S2SC Two Stage, Al Body, Fan Cooled, Flow Through Sampling 65C S3 Three Stage, Al Body, Fan Cooled, Flow Through Sampling 95C* P S2P or S3P: High Pressure option 900 PSIG * Liquid Chilling may be required in the S3 to attain 95C Depression, fan only depression of 70C Standard S & X series sensors rated for 300 PSIG sample Pressure X-Type, Chemical Resistant, High Performance Description Depression X3P 3 Stage, Panel Mount, SS Body, Convection Air Cooled- No Fans, Flow Thru 65C X3F 3 Stage, SS Body, Standard Fan Cooled, Flow Thru Sampling 85C X3SF 3 Stage, SS Body, High Efficiency- Super Fan Cooled, Flow Thru Sampling 95C D-Type, Insertion Probe Description Depression DS2 2 Stage, Insertion Probe, AL, Convection Air Cooled, Diffusion Sampling w/ cable 60C STEP 3: SELECT MIRROR TYPE: Applications CM Configuration General Purpose Gases Acids Caustics Salts Organics Nuclear Application High Temperature Chrome Plated A D D C C D C 316 Stainless Steel A B B B B C B Platinum A A A A A A A A Excellent B Very Good C Good D Not recommended NR Not Rated

Page4 STEP 4: Choose Local or Remote Sensor (DS2 sensor always remote mounted): NO DESIGNATION = LOCAL SENSOR ED ON 1500 (S or X SERIES)- STANDARD CONFIGURATION -RC Remote Mounting Kit S-type Sensor 10 Cable, additional lengths available -RK Remote Mounting Kit D-type Sensor 10 Cable, additional lengths available -RX Remote Mounting Kit X-type Sensor 10 Cable, additional lengths available STEP 5: Choose Special Sensor Options for D-Probe: (The D-probe is always mounted remote) -When Ordering the D-probe, you can specify: -AR Aspirator Mount, this features a built in aspirator to extract a gas sample from the surrounding area -P Pipe Mount, mounts to the D-Probe and allows 1.25inch Male NPT port on the probe -F Pipe Flange Mount w/ Gasket, The D-Probe gets installed into a 4inch diameter SS Flange/ gasket seal, 4 bolt Install. For use with Pipe Flanges, isolation chamber, and HVAC DUCT mounting -SM Surface Wall Mount, The D-Probe is retained between two polypropylene blocks w/ bracket -US Uni-Strut Mount, Same as the surface mount except the blocks are mounted on a unistrut clamp -SC1 Sample Chamber High Pressure (up to 100psig), provides (2) 1/4in Swagelok compression fitting sample ports -SC Sample Chamber Low Pressure (Slip on), same as -SC1 but is not permanent mount, it just slides on/off the probe Pipe Mount (1.25NPT) Aspirator Mount UNI-STRUT PIPE FLANGE SC1 SC Sample Chamber Sample Chamber High Pressure Low Pressure SURFACE- WALL HVAC DUCT STEP 6: Choose Options such as PRESSURE COMPENSATION: -AT Air temperature probe, stainless steel sheath with 10ft cable and connector -PT Pressure Transducer, 0 to 25PSIA or 0-150PSIA, or 0-300PSIA automatic pressure compensation -RS RS-232 Serial Interface -RC Remote Mounting Kit for the S-Probe (up to 40 feet) -VPAC Integrated Vacuum Pump extracts gas sample, for the VAC model -VPDC Integrated Vacuum Pump extracts gas sample, for the VDC Battery Powered model -SC1 Sample Chamber: Flow Through Chamber for D-Probe (up to 100 PSIG sample gas) -SA/.1 0.1 C Special accuracy, traceable to NIST (Certified) -SA/.15 0.15 C Special accuracy, traceable to NIST (Certified)

Page5 LIST ACCESSORIES/ SPARE PARTS/ SPECIAL SERVICES AS SEPARATE LINE ITEMS: FIL Filter kit: includes fittings and additional elements; rated for.1 micron particulate DX Filter Element Kit, Qty 3 SC/S SC/O Screw On Replacement Sensor Cap for the S-Series Slide on replacement cover for the D-probe sensor 1500DC-S2SC-VPDC FlowMeter w/ Pump 1500AC-X3 1500DC-S2SC-AT-VPDC