LOKTRACE TRACER GAS LEAK DETECTION FIND THE LEAK!

Similar documents
LOKTRACE STRICTER LAWS! FIND THE LEAK! Avoid unnecessary fines. Trace gas leak detection

LOKTRACE STRICTER LAWS! FIND THE LEAK! Avoid unnecessary fines. Trace gas leak detection

VEHICLE AIR CONDITIONING REPAIR THE LEAK!

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

LOKRING SINGLE RING MECHANICAL TUBE JOINING SYSTEM FOR REFRIGERANT LINES

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

BAC 4000a BAC 5000yf

AC1234 PRODUCT RANGE.

1. ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2. LOCATION OF INDOOR AND OUTDOOR UNIT 3. INSTALLATION/SERVICE TOOLS (ONLY FOR R410A PRODUCT) 4.

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

PATENTED PATENT PENDING PATENTED PATENTED

Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651

HFO1234 Material. MANIFOLDS: HFO1234 approved MV2HFO set - 2 way Valve deep vacuum manifold way - gauges 80MM HFO carton box 85,26

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Guidance on the construction of CO 2 systems

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

UV-Leak Detection System R 134a. UV-Lamp 12 Volt / 50 Watt 14/663. Workshop Requirements, Workshop Devices and Working Security.

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

R EFRIGERANT A NALYZER S & ACCESSORIES

CLI Refrigerant Gas Leak Detector. User s Guide

PATENTED PATENT PENDING PATENTED PATENTED

PATENTED PATENT PENDING PATENTED PATENTED

User Manual. GPD 3000 e. gas detector

Dräger X-am 5000 Multi-Gas Detection

Best Practices for Mobile A/C Refrigerant System Service

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

SECTION 2 SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES UNIT 8 SYSTEM EVACUATION

Measurement Solutions for Refrigeration Technology.

Measurement Solutions for Refrigeration Technology.

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

The Service Sector Prepares for HFO-1234yf Paul DeGuiseppi MACS Worldwide Mary Koban, DuPont Fluoroproducts

User manual Flushing device VAS 6337/1a

Twin-Agent Fire Fighting/Securing Systems Specifications

DP 300 mobile dew point instrument

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Fluid Exchange. Refrigerant Handling Systems Recovery/Recycling Systems Fluid Exchangers Flushers Fluid Exchange Accessories BUYER'S GUIDE

DANGER DETECTORS 2016 RANGE

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Hospitals and Major Medical Centers

Additional users operating manual

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

SOP CNT 46 Maintenance of Air Conditioning Units by contractors

Safety Laboratory Gas Burner. - A step ahead! Technical Data: The range of delivery:

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

INSTALLATION INSTRUCTIONS

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Page 2 Draft Revision to the Australian Automotive Air Conditioning Code of Practice 2014

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Leak testing in the HVACR Industry

Sensistor ISH2000 Hydrogen Leak Detector

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Which Refrigerant Analyzer do I have? Ultima ID Model RI-2004HV Series

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

testo 316-EX gas leak detector Instruction manual

An Industry Prepares Service Technicians for Refrigerant Transition

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

Dräger X-zone 5500 Area Monitoring

Mobile Air-Con Service Solution. AC7000 Operation Manual

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

Cooling System Equipment

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

Dräger X-am 2500 Multi-Gas Detector

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Custom Products Gallery

AIR CONDITIONING WORKSHOP EQUIPMENT

REFRIGERANT SYSTEM SERVICE WARNINGS

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Helium Leak Detection Systems

TAP TAP-CLAMP

Guide Specifications

Be sustainable while protecting your business

USING THE P-T CARD AS A SERVICE TOOL

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941

Evaporators 60HZ version

Oxeo extinguishing systems

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

IMR EX610. Portable Gas Detector. Operation Manual

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Control of refrigerant gases during manufacture, installation, servicing

Dräger X-zone 5500 Area Monitoring

GMA Panels with double busbar

E1000 Portable gas detector

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

Air Conditioning & Duracool Emery Stora

T.ex Single Gas Detector VISA

Climate Line Equipment

Safe Operation Manual. Honeywell IQ Force Gas Detector

First Revision No. 20-NFPA [ Section No ]

G-TECTA TM. Portable Gas Detection Instruments

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

AIR CONDITIONING WORKSHOP EQUIPMENT

Transcription:

LOKTRACE TRACER GAS LEAK DETECTION FIND TE LEAK!

02 LOKTRACE TRACER GAS LEAK DETECTION LOKTRACE TRACER GAS LEAK DETECTION PROBE WIT DUAL SENSOR YDROGEN TE SMALLEST MOLECULE LEAK FORMING GAS 95/5 ESCAPES ydrogen is lighter than air. The air conditioning tubes and hoses can be checked conveniently from above.

LOKTRACE TRACER GAS LEAK DETECTION 0 FIND TE LEAK! TE LEAK DETECTION SYSTEM, ORIGINALLY DEVELOPED FOR INDUSTRIAL APPLICATIONS, AS BEEN PERFECTLY ADAPTED FOR USE IN SERVICE, AND GUARANTEES LEGALLY COMPLIANT, FAST, RELIABLE AND EASY LEAK DETECTION. FORMING GAS 95/5, which is a mixture of nitrogen and hydrogen, is filled into the In compliance with EU directive 2006/40/EG air conditioning system for leak detection. Forming gas 95/5 is non-flammable, Leak detectors with unique dual sensor non-toxic, non-corrosive and not harmful to the environment. ydrogen molecules Detecting smaller leaks are the smallest naturally occurring particles and escape from minimum leaks. Nearly no cross-sensitivity to other gases With the help of the LOKTRACER TLD.500 the tiniest leaks can be detected. The Easy checking of the evaporator leak detector reacts almost exclusively to hydrogen with nearly no cross-sensitivities to other gases. Suitable for air conditioning systems using FO-124yf CONCLUSION: LOKTRACE finds every single leak! EVAPORATOR TEST The hydrogen molecules escape at the leak in the evaporator and get inside the passenger compartment through the ventilation slots. LOKTRACE COMPARED TO CONVENTIONAL LEAK DETECTION METODS Compliance with legal regulations Direct implementation Detecting smaller leaks Reliability Easy checking of the evaporator LOKTRACE UV dye Electronic refrigerant leak detectors Nitrogen and bubble spray

04 LOKTRACE TRACER GAS LEAK DETECTION YDROGEN LEAK DETECTOR AND TRACER GAS LEAK DETECTION SETS YDROGEN LEAK DETECTOR Specially developed for refrigeration and air conditioning technology. Made in Germany! Reliable hydrogen leak detector with unique dual sensor technology. Very low cross-sensitivity to other gases. Step-by-step convergence on large leaks (zero setting). Automatic sensor cleaning. Without pump or filter thanks to diffusion technology. Integrated LED light. Acoustic and visual alarm. Article no. Article name L1005099 LOKTRACER TLD.500 Technical data Time until ready: < 60 s Response time: 1 to 2 s Operating period: approx. 5 h Power supply: Rechargeable batteries Available separately Article no. Article name Description L1400404 PA-TLD.500 Charging cable CYLINDER TROLLEY SET FOR TRACER GAS LEAK DETECTION Complete kit for tracer gas leak detection in vehicle air conditioning systems. The cylinder trolley is suitable for conventional 10 l or 20 l gas cylinders. Gas cylinder not included in the scope of supply. Pressure reducer connection: W21,8-14 left hand thread (Kits with other pressure reducer are available on request). Article no. Article name L1005004 LOKTRACE KA-500 W21,8-14 Scope of supply Article no. Article name Description Quantity L1005099 LOKTRACER TLD.500 ydrogen leak detector 1 L140099 CT.10/20 Trolley 1 L1400951 PR-TG.10 W21,8-14 10 bar pressure reducer 1 L1005015 PA-1/LT.10 Manifold gauge 10 bar 1 L100491 DS-A-G+G-000-Y Charging hose 1 L1002909 DS-J-G+G-000-Y Charging hose 1 L14002502 QC-14a-BM Low pressure quick coupler 1 L1400250 QC-14a-RM igh pressure quick coupler 1 L1400969 LOKTRACE KA.DC Dust cover 1

LOKTRACE TRACER GAS LEAK DETECTION 05 CASE SET FOR TRACER GAS LEAK DETECTION Complete kit for tracer gas leak detection in vehicle air conditioning systems in a robust plastic case. Pressure reducer connection: W21,8-14 left hand thread (Kits with other pressure reducer are available on request). Article no. Article name L100519 LOKBOX TG-AUTO-500 Scope of supply Article no. Article name Description Quantity L1005099 LOKTRACER TLD.500 ydrogen leak detector 1 L1400951 PR-TG.10 W21,8-14 10 bar pressure reducer 1 L1005015 PA-1/LT.10 Manifold gauge 10 bar 1 L100491 DS-A-G+G-000-Y Charging hose 1 L1002909 DS-J-G+G-000-Y Charging hose 1 L14002502 QC-14a-BM Low pressure quick coupler 1 L1400250 QC-14a-RM igh pressure quick coupler 1 QUICK-COUPLERS FOR FO-124YF Allows the connection of LOKTRACE leak detection sets to FO-124yf vehicle air conditioning systems. For connecting the charging hoses of the LOKTRACE leak detection sets the fitting A-124 is required. Tested in accordance with SAE J2888 (124yf) Connection: M12 x 1.5 Article no. Article name Description L14004188 QC-124YF-BF Low pressure quick-coupler L1400418 QC-124YF-RF igh pressure quick-coupler FITTING M12X1,5 M - 1/4 SAE M For connecting the charging hoses of the LOKTRACE leak detection sets to quick-couplers for FO-124yf. Article no. Article name L14004189 A-124

06 LOKTRACE TRACER GAS LEAK DETECTION ONLINE-SERVICE FOR FURTER INFORMATION, PLEASE REFER TO OUR WEBSITE WWW.VULKAN.COM. AUTORISED DISTRIBUTORS www.vulkan.com/en-us/lokring/contact/ VIDEOS www.vulkan.com/en-us/lokring/videos/ TECNICAL DOCUMENTATION AND SUBMITTAL www.vulkan.com/en-us/lokring/downloads/technical-documentation-and-submittal CATALOGUES & BROCURES www.vulkan.com/en-us/lokring/downloads/ CERTIFICATES www.vulkan.com/en-us/lokring/downloads/certificates/

LOKTRACE TRACER GAS LEAK DETECTION 0 IMPRINT PUBLISER: VULKAN Lokring Rohrverbindungen Gmb & Co. KG eerstraße 66, 4465 erne / Germany Tel.: + 49 (2 25) 922-155 Fax: + 49 (2 25) 51222 E-mail: info.lok@vulkan.com CONCEPT AND DESIGN: ackforth olding Gmb & Co. KG / MSC eerstraße 66, 4465 erne / Germany E-mail: marketing@vulkan.com PREPRESS: ackforth olding Gmb & Co. KG / MSC eerstraße 66, 4465 erne / Germany E-mail: marketing@vulkan.com VALIDITY CLAUSE The LOKRING tube connection technology represents a proven method of producing hermetically sealed metal-to-metal tube connections. The LOKRING tube connections are mainly used in the refrigeration and air conditioning industries. The use of LOKRING tube connection technology in other fields is to be discussed with VULKAN Lokring. VULKAN Lokring as the supplier is responsible for the qualitative delivery of the tube connections and tools which are ordered from this catalogue. The purchaser is responsible for the use of the LOKRING tube connections and tools as directed. The assembly has to be done accordingly to the instructions and exclusively with original LOKRING parts. The present Vehicle Air Conditioning catalogue shall replace all previous editions, any previous printings shall no longer be valid. The data contained in this catalogue refers to the valid state of affairs in time of the copy deadline. Any changes due to technical progress are reserved. Status: 11/2016 All duplication, reprinting and translation rights are reserved. Further remarks for the LOKRING assembly are available on request.

www.vulkan.com www.vulkan.com/en-us/lokring/videos/ VULKAN Lokring Rohrverbindungen Gmb & Co. KG eerstraße 66 4465 erne Germany Phone + 49 (0) 225 922-155 Fax + 49 (0) 225 51222 Mail info.lok@vulkan.com www.vulkan.com For a list of our Authorised Distributors, please refer to www.vulkan.com/en-us/lokring/contact/