Quick Selection Guide Fire Systems LSN Periphery

Similar documents
Interface and EOL Modules 8

Conventional Fire Panel 500 Series

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

Automatic Fire Detectors LSN improved

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

AVENAR detector 4000 FAP-425 / FAH-425. en Operation Guide

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Consultant Specification AGILE Wireless Fire Detection System

Quick Selection Guide Analog Addressable Fire Systems

Automatic Fire Detectors

Solution F2. Fire Alarm Control Panels one step ahead.

OOH740, OOHC740 Automatic fire detectors

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version. Product Information

Modular Fire Panel 5000 Series Just as flexible as your plans

FCS-320-TM Series Conventional Aspirating Smoke Detectors

OH110, OP110, HI110 Automatic fire detectors

Fireray 2000 Linear Smoke Detector

INPUT / OUTPUT MINI MODULES

Instructions for the Fire System Designer (FSD) Rel. 2.1

Conventional Automatic Detectors FCP-320 FCH-320

FCP 320/FCH 320 Conventional Automatic Fire Detectors

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Analogue addressable devices

Fire control panel detect 3004 plus and accessories

Cerberus FIT conventional system

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

Polycarbonate External Sounder & Strobe Unit

Intelligent addressable fire alarm control panel

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

The new detector from Rafiki

FPA 5000 With Functional Modules

FPA 5000 With Functional Modules

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

>WIRELESS> ALARM SYSTEM CR200

Fire Detection Systems Intelligent detection. Superior protection.

ELECTRONIC SOUNDER STROBE Model : AVD-C407

IQ8Control C Fire Alarm Panel

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

intelligent solutions

Evolution Analogue Addressable Fire System

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Installation, Operating and Maintenance Manual

designed for rail 5000 Series

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

Sita200plus. 200detectors. Single loop analogue addressable System

FC724 Fire control panel

DICTATOR Hold-Open Systems for Hazardous Areas

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

FC722 Fire control panel

IFD-E Flame Detector User Manual

COMPACT FLAME CONTROLLER CFC 2000

Vista-50P/-50PUL System Design Sheet

Rules for Intruder Alarm Systems

FC724 Fire control panel

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Fire Product Catalog

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Fire & Security Products. Siemens Building Technologies Group

Cerberus PRO enjoy protecting A comprehensive fire protection system

Description. Optex Incorporated

Addressable Fire Alarm Control Panel

Basic Fire Alarm SystemTraining. Arman Alnasar

MINERVA MZX125 Digital Addressable Fire Detection System

COMPACT FLAME CONTROLLER CFC 1000

New generation FPA-5000/1200. Kristof Vandenberghe

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

IFD-E Flame Detector User Manual

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

ACP10 & ACP50 Security Systems

MINERVA MX. 800 Series Ancillary Equipment

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

Operating Manual MS220KA and MSR220KA

D7024 Fire Alarm Control Panel

Product Documentation

FC723 Fire control panel

Addressable Loop Powered Visual Alarm Devices

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

EnvironmentalMonitoring

Installation and Operation Manual

Operating Manual MS220DA

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Integrated Security Solutions

Addressable Detectors & Bases

OH720, OP720, HI720, HI722

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

Control Panels and Fire Detection Equipment

FC700A Fire detection control unit

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Remote NAC Power Supply D7038

Conventional Fire Detection

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

System 800 Addressable Fire Detection & Alarm System

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

For Complete Fire and Gas Solutions

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Transcription:

Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed structure) All cable types usable (Shielded & Unshielded cables) Reduced programming and installation cost and time No special cable types needed, existing cables can be used Up to 3000 m line length Up to 1.5 A current Up to 254 elements per loop/line Up to 127 elements per loop/line in LSN classic Less installation time and cost through reduced number of loops Increased number of loop powered devices Built-in diagnosis functions Remote support is possible Easy and cost efficient maintenance and support Short circuit isolators in each device increase system integrity and cost savings One cable connects multiple areas Can withstand a short or open circuit at any point in the loop and all devices still function Digital communication into every detector High security against tamper Addressable detectors Automatic or manual address setting possible Easy operation Way of address setting can be chosen depending on wiring One bus for intrusion, fire and malfunction Cost efficient installation, additional security Remote programming and maintenance Cost efficient and time saving Special features LSN improved

FAH-T 420 Heat Detector Combination of rate of rise and fixed temperature measurement FAP-O 420 Optical Light scattering principle FAP-DO 420 Dual-Optical Smoke Detector Dual Ray technology - Two light scattering smoke sensors with different wavelengths (infrared and blue LED) FAP-OT 420 Optical, Thermal Combination of light scattering principle, rate of rise and fixed temperature measurement FAP-DOT 420 Dual-Optical, Thermal Dual Ray technology (see FAP-DO 420) in combination with rate of rise and fixed temperature measurement FAP-OTC 420 Optical, Thermal, Chemical Combination of light scattering principle, rate of rise and fixed temperature measurement as well as combustion gas FAP-DOTC 420 Dual-Optical, Thermal, Chemical Dual Ray technology (see FAP-DO 420) in combination with rate of rise and fixed temperature measurement as well as combustion gas Used where an open, fast-developing fire might occur Used where a smoldering fire might occur Used where equal response to different types of fire is essential Used where open, fastdeveloping fires, as well as smoldering fires, might occur Used in environments with varying conditions Used where CO gas might harm people Used in environments with special conditions to maintain, and where CO gas might harm people

FAP-OC 520 FAP-OC 520-P FAP-O 520 FAP-O 520-P FAD-O 420 and FAD-HS 420 EN Duct Detector White housing Multi-sensor in a combination of combustion gas and scattered-light sensor from any Multi-sensor de tection in a combination of combustion gas and scattered-light sensor Color rings can be fitted into the detector to adapt to the ceiling from any White housing from any Color rings can be fitted into the detector to adapt to the ceiling from any Use in ventilation systems with air velocities from 1 m/s to 20 m/s For the activation of fans, door controls or external display devices an optional relay board can be installed A clear section on the frosted cover allows to view alarm LED of integrated FAD-O 420 detector Tamper control High stability against disturbance values High stability against disturbance values Easy installation in air ducts Allows smoke in demanding environments

FAS-420-TM Aspirating Display sensitivity can be set to 0.05 %/m light oscuration RoomIdent fire localization 10 level smoke density display Innovative air flow sensor technology High Power Light Source Max. 8 aspiration openings and 40 m or 2x25 m pipe lenth FAS-420-TP Aspirating Display sensitivity can be set to 0.015 %/m light oscuration 2 detector modules possible Innovative air flow sensor technology High Power Light Source Max. 48 aspiration openings and TP1: 300m; TP2:560m (2x280m) pipe lenth FAS-420-TT Aspirating Display sensitivity can be set to 0.0015 %/m light oscuration 2 detector modules possible Innovative air flow sensor technology High Power Light Source Max. 48 aspiration openings and TT1: 300m; TT2: 560m (2x280m) pipe lenth FMC-210 DM/SM Manual Call Point Different colors Single and double action Indoor and outdoor s FMC-420RW Manual Call Point Different colors Resettable or with glass pane Single-action call point Indoor and outdoor (IP67) s FMC-420RW Manual Call Point Outdoor Red color only Resettable or with glass pane Single-action EN54-11 and EN54-17 compliant Very early smoke even under challanging environmental conditions Minimalization of false due to intelligent signal processing Easy maintenance and service - no interruption of regular operations Up to 5 rooms can be individually monitored Very early smoke even under challanging environmental conditions Minimalization of false due to intelligent signal processing Easy maintenance and service - no interruption of regular operations 2-detector-dependency Very early smoke even under challanging environmental conditions Minimalization of false due to intelligent signal processing Easy maintenance and service - no interruption of regular operations 2-detector-dependency High flexibility Can be used for fire and other types of manual High flexibility Can be used for fire and other types of manual High flexibility Protection category according to EN 60529: IP67

FNM-420-A-BS-WH / FNM-420-A-BS-RD Base Sounder 2 types: red and white 90 db with current < 5 ma Constant sound pressure level in case of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Combination with detector/beacon FNM-420-A- WH / FNM-420-A-RD Stand-alone Sounder Indoor 2 types: red and white 100 db with current < 5 ma Constant sound pressure level in case of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Double entry back box for simplified installation FNM-420-B-RD Stand-alone Sounder Outdoor Red colour only Outdoor type with IP66 100 db with current < 5mA Constant sound pressure level in case of voltage drop Immediate and permanent synchronization of different sounder groups within one loop 32 tones Different sound pressure levels Double entry back box for simplified installation FNS-420-R Strobe Addressable strobe Freely configurable Combination with detector base or with LSN base sounder Low current consumption of 6 ma FLM-420-I2 Input Interface Module 2 monitored inputs Available as in-built, wall-mount and DIN-rail Contact or voltage monitoring Line monitoring with use of EOL resistor FLM-420-O2 Output Interface Module 2 open collector outputs Available as in-built, wall-mount and DIN-rail Max. switchable current per output 700 ma Max. switchable voltage per output 30 V DC Outputs are electrically isolated from LSN-loop and short-circuit proof FLM-420/4-CON Conventional Interface Module 2 fire zones class B or 1 fire zone class A Available as wall-mount and DIN-rail 200 ma max. supply current per Aux-output switchable Aux for resetting 4-wire detectors > 50 sounders per loop European tones covered Easy installation (sounder snaps into pre-installed mounting plate) Special mounting plate for surface mounted cabling Installation costs reduced by mounting detectors or beacons into the base sounder > 50 sounders per loop Very high, consistent sound pressure level at low power European tones covered Easy installation (comfortable back box with knock-outs and space for cabling) Very robust design > 50 sounders per loop Very high, consistent sound pressure level at low power European tones covered Easy installation (comfortable back box with knock-outs and space for cabling) Very robust weather-proof design Maximum light at 1 Hz frequency for high level of visibility Low current consumption allows connection of a large number of peripheral elements Allows integration with technical (e.g. freezer, air condition) The various monitoring types ensure customized applications Flexible control of external devices One class A or two class B zone Provides integration of conventional fire alarm periphery into LSN systems Compatible with 2- and 4-wire detectors Can be used with a wide range of conventional detectors

FLM-420-RLV1 Relay Interface Module Low Voltage FLM-420-RHV Relay Interface Module High Voltage FLM-420-NAC Signaling Device Interface Module FLM-I 420 Short Circuit Isolator FLM-420-RLV8-S Octo-relay Interface Module Low Voltage FLM-420-O8I2-S Octo-Output Interface Module with 2 Inputs FLM-420-I8R1-S Octo-Input Interface Module with Relay 1 low voltage relay 30 V/1 A LSN improved Available as in-built, wall-mount and DIN-rail 2 high voltage relays (240 V/10 A) 2 supervised feedback lines Available as surface mount and DIN-rail 1 supervised output line reversed polarity with up to 3 A Available as surface mount and DIN-rail Isolation of short circuits on LSN-Line Eight change-over contact relays provide potentialfree contact outputs Maximum switching capacity of the relays 2 A / 30 V DC Eight individually switchable open collector outputs Max. switchable current per output 700 ma Outputs electrically isolated from LSN loop and short circuit proof Individually selectable monitoring functions (EOL or contact) for the two inputs each Individually selectable monitoring functions (EOL or contact) for each of the 8 inputs Maximum switching capacity 2 A / 30 V DC Control of external applications Supervision and control of external applications e.g. extinguishing systems Supervised control of signaling devices Easy monitoring and activating of signaling devices Isolator for T-tap-systems Functionality of the remaining network is preserved Easy wiring thanks to pluggable terminal block Control of external applications Easy wiring thanks to pluggable terminal block Control of technical LED-tableaus Easy wiring thanks to pluggable terminal blocks Integration of technical

FLM-420-RLE-S Interface Module 1 low voltage relay (30 V, 1 A) 2 supervised input lines 1 input line programmable as relay feedback DIN-rail mountable Delivered with housing for surface mounting FLM-420-O1I1 Output-Input Interface Modules Open collector output electrically isolated from LSN loop and short-circuit proof Max. switchable current per output 700 ma Individually selectable input monitoring functions (EOL, contact or voltage) FK 100 LSN RF Interface Module Connection of up to 30 wireless detectors Bi-al data transfer 868-870 MHz short range device Transmission path monitoring LSN classic DOW 1171 Radio Deception-proof operating behaviour High resistance to elec tromagnetic interference, temperature changes, humidity, corrosion and contamination Smoke detector with outstanding interference immunity Conntectable to FK-100-LSN MPA Detector Remote Indicator DIN 14623, ATEX PTB01, ATEX 2163X Good visibility Elegant, robust and efficient design Easy localization of detectors Compatible to LSN-classic and LSN improved FAA-RI 420 Remote Indicator Good visibility Elegant, robust and efficient design Easy localization of detectors Compatible to LSN-classic and LSN improved Supervision and control of external applications, e.g. extinguishing systems Conformity to VdS 2496: 2005 Low supply current Available as in-built and DIN-rail Control of external devices Easy expansion of existing fire alarm systems High transmission and functional security Outstanding interference immunity Easy extension of existing fire alarm systems without additional wiring VdS approved Parallel indication for detectors in false ceilings Mounting in corridors or access pathways Parallel indication for detectors in false ceilings Mounting in corridors or access pathways Cost-efficient solution