Temporary LPG Heat for Construction Sites Information Packet

Similar documents
Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG

Department of Public Safety

Liquefied Petroleum Gas Facility Written Fire Safety Analysis

Liquefied Petroleum Gas Facility Written Fire Safety Analysis

MOBILE FOOD VENDING Food Trucks & Trailers

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

SOUTH CAROLINA LIQUEFIED PETROLEUM GAS PROGRAM (LP-GAS)

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

OUTDOOR FIREWORKS DISPLAY

Changes for the New Edition. Senior Engineer, NFPA NFPA

Tents and Temporary Membrane Structures Permit Procedure

Tents and Temporary Membrane Structures Packet

FIRE DEPARTMENT PERMIT GUIDELINES

Note: The event coordinator is responsible for compliance of all regulations.

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

ksnow Model Rocket Launches Information Packet Colorado Springs Fire Department Division of the Fire Marshal

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Outdoor Festival and Special Event Guidelines

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

SafetyNet FIRE MARSHAL S OFFICE. Food Booth and Vendor Regulations

OUTLINE FOR FIRE PREVENTION ACTIVITY

Above Ground Fuel Tank Requirements

Note: The event coordinator is responsible for compliance of all regulations.

SEMINOLE FIRE DEPARTMENT TENT PERMIT CONDITIONS

Fire Safety Plan Information. For Construction and Demolition Sites

South Davis Metro Fire Agency

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

CITY OF PASADENA FIRE DEPARTMENT

EXAMPLE FIRE PREVENTION AND PROTECTION PLAN WORKSHEET

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

To expedite the plan review and inspection processes, please refer to the information below.

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

Impairments to Fire Protection Equipment

Fire Sprinkler Submittal Requirements and Acceptance Testing

2010 FIRE CODE OF NEW YORK STATE

VENDOR AGREEMENT PACKET

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Jefferson Cocke County Utility District Marketing Plan (July 1, 2008 through June 30, 2019) Revised effective July 01, 2016 A) Identify commercial

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

FIRE PREVENTION CODE

Iowa Propane Gas Association 2018 Training Descriptions

EXCELSIOR FIRE DISTRICT

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

CITY OF TOLEDO. Paula Hicks-Hudson. MAYOR Our Division s web-site can be accessed 24/7 at

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

CITY OF TOLEDO. MICHAEL P. BELL MAYOR Our Division s web-site can be accessed 24/7 at

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS


City of Vista Fire Department

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Builders Risk - Fire Prevention Inspection Checklist

Dear Exhibitor, To assist in th. and safety issues that you may encounter with your booth.

C i t y o f G r o v e r B e a c h ADMINISTRATIVE SERVICES DEPARTMENT

Fire District Dwelling Construction Requirements

West Norriton Township

CARBON DIOXIDE SYSTEMS FOR BEVERAGE DISPENSING PERMIT REQUIREMENTS

Recommended Amendments to the 2003 International Fire Code North Central Texas Council of Governments region

CAMP VERDE FIRE DISTRICT

CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

New Construction Fire Inspection Process

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

DEPARTMENT OF PUBLIC SAFETY. Division of Fire Prevention and Control 8 CCR

CHRISTMAS TREE LOT INFORMATION & REQUIREMENTS

Construction and Development Guide

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

South Elgin & Countryside Fire Protection District

Plan Submittal Checklist

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Appendix J Framework Fire Prevention and Suppression Plan. Prepared by Idaho Power Company 1221 W Idaho Street Boise, ID 83702

June 2018 Safety Meeting Fire Extinguishers Part I

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

The regulatory section first discusses codes and standards and then Federal and State legislative and local requirements.

City of Leduc Fire Services Indoor Special Event Requirements

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

GASEOUS HYDROGEN SYSTEMS

APPLICATION FOR Large Family Day Care Permit

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Family Foster Home Fire Safety Evaluation Checklist Instructions

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

Community Festival Permit Application - Cypriot Community of Toronto Inc. - Cultural and Wine Festival June 23 and 24, 2007

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

Transcription:

Temporary LPG Heat for Construction Sites Information Packet Colorado Springs Fire Department Division of the Fire Marshal February 2014 W:\Packets\Haz Mat\IFC2009_Temp_LPG_Heat_For_Construction.doc

TEMPORARY LPG HEAT The CSFD Office of the Fire Marshal has developed this packet in order to assist propane contractors with LPG-fueled temporary heating assemblies for a construction site. The fees for this permit and inspection shall be assessed in accordance with the CSFD Permit Fee Schedule and the permit/inspection fees shall be due upon receipt of the permit. PERMIT APPLICATION Any application for a Temporary LPG Heat shall be filled out in its entirety and shall be accompanied by a detailed site plan showing: 1) Location and legal identification (address and lot or parcel number) 2) Legal boundaries of the site, including reference to source or survey. 3) Location of significant buildings on the lot or site and adjacent lots or sites. Declare separation distances in feet. 4) Location of nearest public roadways and site access. Id Declare separation distances in feet. 5) North arrow. 6) Topographical features; declare separation distances to exposures or hazards in feet. 7) Proposed container location with respect to buildings, building openings, lot lines, public roadways, and underground or overhead utilities; appliances or equipment, ignition sources, declare separation distances in feet. 8) Container dimensions and capacity; 9) Container compliance markings, (ASME, DOTn, API) 10) Details of container foundation and supports. 11) Section through container showing supports and anchors and, if underground tank, backfill and corrosion protection. 12) Arrangement of valves and piping, identify emergency shut off locations 13) Specifications for containers, valves, piping, tank mounts and pads and other related equipment and application; if temporary LPG for heating appliances for construction sites-- heating appliance specifications, manufacturer, supplier-installer, qualifications. Provide specifications/cut sheets on heating units, the number and their location/placement within building or on property. 14) Means for protecting valves from tampering. 15) Name, address and telephone number of installer and servicing contractor; and emergency contact number and names for owner and LP Gas supplier contractor. 16) A Scope of work; (i.e. use for temporary heat) 17) REQUIRED. Qualifications of installer/attendants. Provide copies: Certified Employee Training Program (CERT) by the National Propane Gas Association. Certification shall be readily available to the Fire Inspector at the time of Inspection. 18) Declare anticipated dates of use (duration) and removal. 19) Fire protection and prevention measures to be implemented or on site: standpipes, water supply, fire extinguishers, firewatch, site security, Fire Department access, etc. Identify items on site map. 20) Attach forms: Contractor Permit Application, Installer and Client Certification of Compliance form, Installation and Client Declaration form. 2

A COPY OF THIS APPLICATION FORM SHALL REMAIN ON SITE WITH THE PERMIT INSTALLATION No temporary LPG-fueled heating assembly with a tank in excess of the exempt size requiring a permit in accordance with the 2009 International Fire Code, as Amended by the City of Colorado Springs shall be installed without first obtaining a permit (125 gallons water capacity). All LPG-fueled heating appliances and assemblies shall be installed in accordance with all applicable provisions of the 2009 International Fire Code, as Amended by the City of Colorado Springs as well as all applicable provisions of NFPA 58, Liquefied Petroleum Gas Code. The LPG tank(s) installed for temporary heat at a construction site may not exceed 2,000 gallons (water capacity) for an aggregate of tanks. Additional tanks shall require prior approval and review by the CSFD. For the purposes of this permit only, the CSFD defines a site as a single street address. INTERIOR USE The installation of LPG containers may be installed indoors, only if in accordance with the following provisions of the 2009 International Fire Code, as amended by the City of Colorado Springs and NFPA 58, Liquefied Petroleum Gas Code current edition. Limited to conditions where indoor use is necessary and locating cylinders outdoors is impractical (subject to the discretion of the CSFD (NFPA 58). Containers shall be specifically allowed for indoor use (NFPA 58). 125 gallons water capacity (530 lb.) single container or aggregate of all containers, maximum (NFPA 58). LP-Gas containers shall NOT be used in a basement, pit or similar location where heavier-than-air gas might collect. Shall not be used in an above-grade under floor area unless provided with an approved means of ventilation (subject to the discretion of the CSFD (2009 IFC). INSPECTION Upon receipt of application approval, the installation contractor shall schedule a code compliance inspection through the CSFD Office of the Fire Marshal for the installed assembly and use site. This inspection shall be scheduled prior to filling any tank. The site and assembly will be inspected to insure that the installation and use of equipment is in accordance with all applicable provisions of the 2009 International Fire Code, as amended by the City of Colorado Springs and NFPA 58, Liquefied Petroleum Gas Code current edition. 3

REINSPECTIONS If, upon inspection, the CSFD Inspector identifies any issues that do not conform to all applicable provisions of the 2009 International Fire Code, as amended by the City of Colorado Springs and NFPA 58, Liquefied Petroleum Gas Code that cannot be immediately corrected, a Cease and Desist Order Notice will be issued by the Inspector for the use of the temporary heat operation at the site. A re-inspection will be required and a re-inspection fee will be assessed in accordance with the CSFD Fee Schedule. The Cease and Desist Order Notice will remain effective until relieved by the Inspector after a successful re-inspection. 4

INSTALLATION AND USE DECLARATION I have read and understand the above installation and use requirements, and with my signature guarantee no changes will be made after the Fire Inspector s inspection. I understand that all applicable provisions of the 2009 International Fire Code, as amended by the City of Colorado Springs and NFPA 58, Liquefied Petroleum Gas Code current edition, apply. Installer s Representative (Printed) Company Name Installer s Representative (Signature) Date User s Representative (Printed) Company Name User s Representative (Signature) Date 5

Colorado Springs Fire Department TEMPORARY LPG HEAT CONTRACTOR PERMIT APPLICATION CLIENT INFORMATION Business Name: Business Address: City, State, Zip: Daytime Phone: After-hours Phone: Fax Number: INSTALLER INFORMATION Business Name: Business Address: City, State, Zip: Contact Person: Daytime Phone: After-hours Phone: _ Fax Number _ After-hours Phone: _ TEMPORARY LPG HEAT INSTALLATION LOCATION INFORMATION Business Name: Installation Address: City, State, Zip: Location on Property: Number of Tanks: Size of Tanks Tank Serial Numbers Date(s) planned for Temp LPG Heat Date(s) planned for Temp LPG Heat Date(s) planned for Temp LPG Heat Installation: _ Use: Removal: Date: Permit Fee Plan Review No: _ For Office Use Only Permit #(s) _ Receipt # 6

INSTALLER CERTIFICATION OF COMPLIANCE I will install the assembly in full conformance with the applicable provisions of the 2009 International Fire Code, as amended and NFPA 58. I will instruct the User of the assembly in the daily use of the Installation Checklist as well as of proper emergency shut-off procedures. I will document this instruction by obtaining a duly executed User Certification of Compliance form as outlined in this Packet. A copy of this signed form will be posted with the Colorado Springs Fire Department Permit. I will explain each of the checklist requirements and the appropriate corrective actions. I understand that this certification is being made in conformance with the 2009 International Fire Code, as amended and NFPA 58. I understand that installation of an assembly that does not comply with the requirements of the 2009 International Fire Code, as amended and NFPA 58 is a violation of local law. I have instructed and trained a minimum of 2 individuals employed by the User" to perform shutdown of propane equipment and tanks in the event of an emergency. Signed: Date Official of Installing Company Printed Name: CLIENT CERTIFICATION OF COMPLIANCE I have read and understand the applicable installation and periodic surveillance requirements as outlined in the 2009 International Fire Code, as amended and NFPA 58. I agree to abide by the policies, codes, and standards as outlined in the 2009 International Fire Code, as amended and NFPA 58. I agree to conduct, or have conducted by a designated employee, a daily self-inspection of the installation utilizing the Installation Checklist provided in this Information Packet. I agree not to use the assembly unless it fully meets the requirements for installation and passes the Installation Checklist without exception. I have provided a minimum of 2 individuals, employed by my organization that have received proper instruction and training from the Installer to perform shutdown of propane equipment and tanks in the event of an emergency. Signed: Date Official of Installing Company Printed Name: 7

SITE MAP A B C D E F G H I J K L M N 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 A B C D E F G H I J K L M N BUSINESS: ADDRESS: DATE: PAGE _ OF _ 8

SYSTEM SETUP AND DAILY CHECKLIST YES Item to Verify NO Corrective Action Indoor tanks (if necessary) do not exceed 525lb / 125 gallon water capacity. Move tank outside to appropriate location in accordance with code-required clearances. Indoor tanks are not within 6 feet of a heating appliance. Move cylinder more than 6 feet away from heating appliance. Forced-air or radiant heating appliances are not Move cylinder more than 20 feet from appliance. directed toward a tank within 20 feet. Tank is not located in a basement or pit. Move tank to an above-grade location. Outdoor tank does not exceed 4500 lb / 1000 gal water capacity. Remove tank and replace with tank of less than 4500 lb / 1000 gal water capacity. Outdoor tanks up to 500 gal water capacity are Move tank to a proper location. at least 10 feet from buildings, property lines and/or vehicular traffic. Outdoor tanks to 501-1000 gal water capacity Move tank to a proper location. are at least 25 feet from buildings, property lines and/or vehicular traffic. All tanks are farther than 6 away from a vertical plane below overhead electrical lines. Move tank outside of a 6 distance from below electrical lines (applicable when lines carry greater than 600V). Proper required No Smoking / No Open Place signage. Flame and NFPA 704 placards installed on, or in the immediate vicinity of tanks. Weeds, grass, brush, trash, other combustibles Remove combustibles or relocate tank. kept a minimum of 10 feet from tank. Vehicular protection has been installed around Install vehicular protection or relocate tank. tanks exposed to proximate traffic. Tank shows no signs of denting, bulging, Replace tank. Gouging or corrosion. Hose is continuously marked LP-GAS, Replace with proper hose. PROPANE, 350 PSI WORKING PRESSURE. Portable heaters are equipped with an Replace heater. operational automatic shutoff device. Portable heater is self supporting or cylinder- Replace heater. mounted. Aboveground piping is supported and Properly support and protect. protected against physical damage (shielded or in a conduit). Buried piping is below a minimum of 12- Properly bury. inches of cover. Approved fire extinguisher(s) provided that Obtain & place proper extinguisher. contain a minimum of 18 pounds of dry chemical. Minimum Rating: 80-B:C Dist.: 10-50 ft. Minimum Rating: 40-B:C.Dist.: 10-30 ft. At least 2 individuals, properly instructed and trained to perform shutdown of propane equipment and tanks in the event or an emergency are present on this site. Obtain proper instruction and training from Installer. Inspection Performed by: Date: _ 1