FLAME SENSOR FS-2000E

Similar documents
PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

CAUTIONS ON INSTALLATION

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

PHOTOELECTRIC BEAM SENSOR

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Twin Photobeam Detectors Manual

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

Buzzer Unit. TAN-5000 Series. Operating Manual

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Long-Range Barrier Sensors

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

HX-80NRAM. High Mount Outdoor Detector

FLV 40 UV Flame Detector

Static Pressure Control

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

240 ASSEMBLY & OPERATION MANUAL

Auto Dialer. Manual E-921APQ E-921GPQ

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Remote Vehicle Control System

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

GAS MONITOR Model Model

Advanced Ultraviolet Burner Controller

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Macurco HD-11 Hydrogen Gas Detector

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Installation and ZONES: Operation Manual. Model: ON STI-34108

CA 120 Owners Manual of 10

AUR300C. Advanced Ultraviolet Burner Controller

Remote Vehicle Control System. Security and Convenience System

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

Waving Lighted Snowman Yard Art

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

16 OUTDOOR MISTING FAN

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

E1.5 ELECTRIC FAN HEATER

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Acusensor 3. Instruction Manual

Instruction Manual EVA-STB-RL

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

MD12-1 Vehicle Loop Detector

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

Furnace Gas Detector Head GD-A2400. Operating Manual (PT2-162)

flexibility programmed settings.

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

COMBINATION SENSOR. COM-50XTL : OUTDOOR 165ft (50m) Instruction Manual

INSTRUCTION MANUAL EPH-121 CONTENTS

MBCE-110/230UV Flame Sensor Module

Model Instruction Manual. Coleman Limited One-Year Warranty. 26 Quart Power Cooler. For use with 12 VDC only

INSTRUCTION MANUAL PC255O

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

OGCF2002A User Manual

JA-63 Profi User manual

640 Series Advanced Remote Vehicle Security System

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

INSTRUCTION MANUAL PC255O

Horizontal Bottle Cooler Installation and Operation Manual

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

Interrupted Ignition Series Oil Primary Control

Model 4001 Series Single Channel Controller

Auto/Air Power Adapter for Dell Quick Installation Guide

Operating Instructions

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

FW-RA-LED Remote Multiplex Annunciator Panels

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Portable Space Ceramic Heater

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

PORTABLE AIR CONDITIONER OWNER S MANUAL

40E ELECTRIC FAN HEATER

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Product Manual SZ1145

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

18E ELECTRIC FAN HEATER

OilSET-1000 (12 VDC)

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

SAFETY INFORMATION AND WARNINGS

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Instruction Manual Water Sensor

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Transcription:

FLAME SENSOR FS-2000E We appreciate your purchase of a TAKEX flame sensor. Please read this instruction manual carefully for correct and effective use. This sensor is designed to detect flames and to initiate an alarm, it is not a fire-preventing device. TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God including inductive surge by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance. This sensor detects Ultraviolet rays in the flames and initiates an alarm. It does not detect smoke, heat. PRODUCT DESCRIPTION Flame sensor FS-2000E is designed to detect ultraviolet rays contained in flames, and to initiate an alarm. In addition to alarm sound, FS-2000E is equipped with form C N/C, N/O.) output, to meet professional application. Also, memory LED enables you to find out the initiated sensor out of a series of sensors. Area adjustment mechanism brings wide selection of protection angle. Quick separation of sensor and base eases installation and maintenance. 1 PARTS DESCRIPTION 1-1 Description Wire lead For exposed wiring) Knockout for exposed wiring Wiring hole Terminals Locking screw hole Release lever BASE UNIT Wiring hole Sensor head Detection window Sensor built-in) SENSOR UNIT Front mark Area locking screw Memory LED yellow) Blinks for 3min. after alarm then Light on for 47 min. Alarm LED Red) Blinks during offdelay 10sec. Buzzer Built-in) Alarm sound : Sounds intermittently during offdelay 10sec. Mode selector 1-2 Accessory 1-3 Mode setting Mode selector Tapping screw 4 25) 2 pcs Sensor locking screw 3 6) 1 pc Instruction manual 1 copy Alarm Sound Alarm Memory 1 2 3 4 5 Detection timer Detection Sensitivity

2 ATTENTION Product classification This sensor is designed to detect ultraviolet rays contained in flames, and to issue a signal. This unit is neither fire detector nor heat detector nor smoke detector. TAKEX is not responsible for damage, injury or losses by fire, accident, calamity, Acts of God including inductive surge by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance. Others When an strong impact is given to the sensor, it may cause damage, malfunction or less performance. Do not handle in a rough manner. Intense flames such like gas explosion's may damage the sensor, instead of the detection. Objects to be detected This sensor detects ultraviolet rays contained in flames. Therefore, this sensor may detect something including ultraviolet rays but not in flame. Besides, this sensor does not detect the burning object which is not flaming. Possible cause of false alarm Do not install the sensor nearby the followings. Flames which can not be detected. Halogen lamp Electric discharging lamp such like mercury lamp Electric sterilizer lamp Spark of welding Electric spark caused by motor, pantograph) Sunlight Electric discharge of thunderbolt High electric field All the objects which emanates ultraviolet rays Flames through the glass or transparent resin Lighting portion of cigarette Burning charcoal or briquet Electric stove Burnig object without flames 3 DO'S AND DON'T'S According to the detection area chart and operation check, decide installtion place not to form the death angle. Do not install in the following places. Do not install in a site which is subject to direct or reflecting sunlight and rain. This sensor is for indoor use only) Do not install in high humid place such like bathroom. Do not install in a site where fire flame) is usually used such like kitchen. Do not install in front of the object to intercept light. including glass and transparent resin etc.) Do not install in a site where the temperature falls less than 14F 10C) or rises more than 140F 60C). Do not give an impact to sensor. it may cause damage, malfunction and less performance to the sensor. Do not put water to the sensor, or leave the sensor in humid place. It may cause malfunction. This sensor's alarm output is 2 sec. offdelay, and alarm sound / LED is 10 sec. offdelay action. By detecting a flame, the alarm will be initiated after the set time of timer passed. The alarm action continues during the fire, and stops 2 sec. and 10 sec. later each after the extinction. Alarm sound : intermittently LED : continous) when alarm sound is "OFF", it does not sound.

4 WIRING Terminal arrangement Power 10 to 30VDC non-polarity) Stand-by : 25mA Alarm : 75mA Max. buzzer : ON) 40mA Max. buzzer : OFF) Alarm output Dry contact relay output Form C Action : Offdelay detection time + 2 sec.) Capacity : 30V AC/0.3A or less protective resistance 3.3 ohms) Tamper Dry contact output Form BN.C.) Action : Open when sensor unit is detached Capacity : 30V AC/0.25A or less COM N.C. N.O. 1 2 3 4 5 6 7 Basic connection [2 units connection in series N.C.)] Sensor 1 Sensor 2 Power Signal input N.C.) Control panel Allowable wiring distance between sensor and power source Size of wire used Distance at 12VDC AWG 22 Dia. 0.65mm) 490 ft. 150m) AWG 20 Dia. 0.80mm) 820 ft. 250m) AWG 18 Dia. 1.00mm) 1,230 ft. 375m) Note 1) The maximum wire length, when two or more units are connected, is the above distance divided by the number of units. 2) The protection circuit can be wired to a distance of 3,280 ft 1,000m) with AWG 22 0.65mm dia.) wire. 5 INSTALLATION Locate the installation site. Ref : 3, DO'S AND DON'T'S and 7, DETECTION AREA) Slide the release lever to detach the sensor unit. Connect wire to terminals of the base. Ref : 4, WIRING) Make the set-up of detection timer, alarm sound and alarm memory. Ref : 6-2) Function setting) Attach the sensor unit to base unit. Detach sensor unit, and turn Area locking screw to right and fix sensor head tightly. All the inside of lock window have to be turned into black. Fix the base with the screws included. Ref : Base installation described later) 1) Turn front marks of base unit and sensor unit point same directions. 2) Insert sensor unit into base unit. Attach sensor unit on base unit. 3) Push sensor unit until release lever is locked. When sensor unit is detached, wrap it in palm and slide release lever. To make the exposed wiring, break the knockout and insert wires into the wire lead. Check operation and area. Sensor head can be adjusted ahead with 4 steps. Ref : 7, Detection area) To lock sensor unit, insert sensor locking screw into locking screw hole and tighten it.

[Installation of base] Installation hole Installation hole This product is equipped with installation holes pitch 3.29" or 83.5mm) to make installation easy and the sensor's direction adjustable. approx. 5mm 6 OPERATION AND FUNCTION 1) Operation 2) Mode setting Alarm Basic action) This product alarms only by detecting the flame continuing for the set time of detection timer. 0.2sec., 1sec., 6sec., 30sec.) Installation hole Marking 1) Place the base on the site and 2) Thrust the 2 pcs. of tapping 3) Adjust the sensor's direction mark on 2 points 180apart. screws accessory) leaving 5mm by turning the base. exposed from the surface. adjustment range 25 4) Tighten the screws. Buzzer : Sounds intermittently every 0.2sec. LED : Lights on Alarm output : Continuous When the flame continues further, the above alarm actions are also continued for the meantime. 2sec. after the flame goes out, alarm output stops, and 10sec. after, alarm sound and LED stop off delay). Then sensor goes back to armed mode. FS-2000E is equipped with 4 functions which can be used according to the application or environment. Mode setting will be done by mode selector dip switch) in accordance with mode setting chart on the back side of sensor unit. Mode selector 1 2 3 4 5 Detection timer Alarm Sound Detection Sensitivity Alarm Memory Alarm sound buzzer) Buzzer can be off by mode selector No.1, when external output is used. 1 Factory set : ON) Alarm memory 2 Factory set : AUTO) ON OFF When 2 or more sensor are connected on 1 loop, which sensor is initiated can be monitored by Memory LED yellow) for 50 min. after alarm output. Memory LED will be off automatically after 3 min. of blinking and 47 min. of lighting on. In case that the sensor initiates alarm again while its memory LED is lighting, LED continues to light on for further 47 min. after that. re-trigger action) AUTO ON) OFF To reset the sensor LED which is blinking or lighting on, Detach sensor unit from base unit and attach it again, or put off power and on again. Power on reset) The following setting is about detection performance. This unit detects ultraviolet rays in a flame and issues a signal. In the semi-outdoors, there are many objects which generate ultraviolet rays and because there are no walls or windows in open area, there is a much higher possibility for the unit to detect those objects, in comparison with indoor installations. The detection performance should be set using the dip switches according to the circumstances of the installation site. When the performance of the installed sensor is unstable and the cause cannotbe indentified, select Sensitivity "L" and detection time one step longer than current setting. Detection Sensitivity Detection sensitivity is selectable STD or L. STD: Standard setting: Same sensitivity as previous model) 3 Factory set : STD) Detection timer An alarm output occurs when the flame continues for set time of detection timer or longer. 4 5 Factory set : 0.2 sec) Timer Application and installation For the quick detection of the 0.2 sec flame of lighter / match at no smoking zone. 1sec 6 sec 30 sec L 50%) STD 100%) Detection distance on "L" setting is 50% shorter than that on "STD" setting. If the operation is unstable on "STD", switch to "L". When installed semi-outdoor, "L" setting is recommended. When above setting is not stable. For the detection of the fire at smoking zone At the window etc. which is subject to reflection of sunlights. When the ultraviolet rays of a flame is weak it is related to size of flame and distance to sensor), alarm initiation may be delayed beyond the set time. The ultraviolet rays are not visible, and may be detected from unexpected object. When the sensor's operation is not stable it detects something but not a flame) and its cause can not be identified, set detection time longer by one step and see the course.

7 DETECTION AREA 1. DETECTION AREA 2. AREA ADJUSTMENT Detection area spreads out in front of the sensor at approx. 120conically. The size of detection area is in proportion to the size of flame and the time of flaming. The bigger flame becomes or the longer flame continues, the bigger detection area becomes. When small flame such like lighter's is the object to be detected, confirm detection area. When improper area setting is found out by operation check, adjust area setting. Adjustment range Horizontal 25By base unit Vertical 304 steps) By sensor head sensor head Detection area 23' 20' 7m)6m) Front view : Ceiling mount Top view : Wall mount Condition of detection area Detection timer : 0.2sec. Origin of flame : Gas lighter Size of flame : Approx. 2.75" 7cm) 20' 23' 6m)7m) 23' 20' 7m)6m) Side view : Ceiling / wall mount 20' 23' 6m)7m) Sensor installation surface can be covered by the most forward area setting. After the adjustment, detach the sensor unit. Fix the sensor head by turning Area locking screw to right, and attach it again. LOOSENED FIXED To be fixed To be loosened 20' 6m) 20' 6m) 30' 9m) 30' 9m) 33' 10m) 33' 10m) 30variable 4 steps 8 OPERATION CHECK 1. Turn power on. 2. Ignite a lighter etc. within detection area for more than the set time. 3. After the set time, an alarm output is issued, buzzer sounds intermittently and LED blinks. Alarm action) 4. 2 sec. after the flame goes off, alarm output ends. 10sec. after the flame goes off, other alarm actions ends. Check the alarm output by connecting a device such like bell / siren.) Area locking screw have to be turned with a big cross driver until the inside of changes to complete black FIXED : turn to right) or white LOOSENED : turn to left). Area locking screw Do not use a lighter in no fire zone because it is dangerous. In such case, operation test have to be done in other place with sensor only. 9 TROUBLESHOOTING Trouble Completely inactive Sometimes inactive Activated without flame The alarm LED and buzzer works but the connected devices are inactive Solve possible problems according to the following table. If normal operations can not be restored by these corrective actios, contact either the dealer from whom you bought the unit or TAKEX. Check No power supply Broken wire or improper wire) Low voltage When power supply wired) Interrupting rays objects in front of detection area Glass, transparent resin are interrupting rays objects) Sensor inside is wet by condensation etc. Improper area setting Detection window is soiled with dust Low voltage Large electrical noise source such as a redio station or high-voltage wire nearby Unexpected ultraviolet rays nearby Ref : 2, ATTENTION) Sensor inside is wet by condensation etc. Poor contact output connection or broken wire The connected unit's trouble Correct power supply or replace broken wire Remove the interrupting rays object Dry out sensor inside, and remove the cause of the wet Relocate the sensor to appropriate position Remove the dust and soil Correct power supply Relocate the sensor Corrective action Remove the origin of the ultraviolet rays, interrupt ultraviolet rays, or relocate the sensor Dry out sensor inside, and remove the cause of wet Check the wiring or connection Check the connected unit

Maintenance Check the operation once a week. Do'not fail to check operation whenever a funiture in the place is moved. When detector elements are stained, spray alcohol to the elements and remove the stain. Do not use such chemicals as mild detergent, thinner or benzine to clean the detector elements. When housing is stained, clean it with a soft cloth. alcohol detector elements 10 SPECIFICATIONS Product name Model No. Detection system Detection area Sensitivity adjustment Power supply Power consumption Alarm output Alarm memory LED Alarm sound buzzer) FLAME SENSOR FS-2000E Ultraviolet rays detection Detected wave length 185 to 260nm) Distance 33ft.10m) [2.75"7cm)lighter flame, in front] Angle Approx. 120 conically Adjustment range Horizontal 25 by base unit Vertical 30 4 steps by sensor head Detection Sensitivity STD[100%],L[50%]) Detection timer 4 steps 0,2 sec., 1 sec., 6sec., and 30 sec.) 10 to 30VDC non-polarity) Stand by : 25mA or less Alarm : 75mA or less alarm sound ON) 40mA or less alarm sound OFF) Dry contact relay Form C alarm : open/close) Contact action : Off delay approx. 2sec.) Contact capacity : 30V0.3A, protective resistance 3.3 ohms Auto-reset operation on/off setting available) Memory LED blinks for 3 min. then light on for 47 min. Alarm LED red) : light on for off delay 10sec. Memory LED yellow) : light on when memory indicated, blink when power turned on Alarm : Sounds intermittently every 0.2sec. during off delay 10sec. Volume : 80dB or more at 3.3ft. 1m) ahead Silent setting is available) Dry contact Form B N/C) Tamper output Action : open when sensor unit is detached Capacity : 30V0.25A Wiring Terminals Ambient temp. renge +14 F to +140 F -10 C to +60 C) without condensation Installation Indoor ceiling or wall mount) Weight Approx. 150g 5.25oz) External dimensions φ4.72" 120mm) H 1.58" 40mm) Appearance ABS resin white) Tapping screw φ4 25, 2 pcs. Accessories Sensor locking screw φ3 6, 1 pce. Option Ceiling mount attachment BCW-401) 11 1.58" 40mm) 0.31" 8mm) Locking screw hole Alarm LED Red) Detection window OPTION EXTERNAL DIMENSIONS 4.72" 120mm) 3.88" 98.5mm) Release lever Ceiling/wall mount attachment variable attachment) Buzzer built in) Sensor unit Memory LED Yellow) 35 5-0.17" 5-4.2mm) Wiring hole R0.59" R15mm) 0.17" 4.2mm) 35 Base unit 35 2.63" 66.7mm) 3.29" 83.5mm) Unit: inch mm) Variable Sensor head 35 0.35" 9mm) MOUNT & WIRING HOLE 0.41" 10.5mm) 1.34" 34mm) For angle adjustment more than horizontal 25or vertical 30. Limited Warranty : TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option,free of charge, any defective parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be charges rendered for product repairs made after our Warranty Period has expired. In Japan Takenaka Engineering Co., Ltd. 83-1, Gojo-sotokan, Higashino, Yamashina-ku, Kyoto 607-8156, Japan Tel : 81-75-501-6651 Fax : 81-75-593-3816 http : // www. takex-eng. co. jp / In the U.S. Takex America Inc. 3350, Montgomery Drive Sant Clara, CA 95054, U.S.A. Tel : 408-747-0100 Fax : 408-734-1100 http : // www. takex. com In Australia Takex America Inc. 4/15 Howleys Road, Notting Hill, VIC, 3168 Tel : +61 03) 9544-2477 Fax : +61 03) 9543-2342 In the U.K. Takex Europe Ltd. Takex House, Aviary Court, Wade Road, Basingstoke, Hampshire. RG24 8PE, U.K. Tel : +44) 01256-475555 Fax : +44) 01256-466268 http : // www. takexeurope. com No.05-783 1404