FC-2200 Flame Detector

Similar documents
FS10-R30 Flame Detector

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA

HR Powder Feed Hopper

Liquid Adhesive Detection System Alarm Box

Heliport Perimeter Light Type MIJ

U7698E Flame Detector

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

TABLE OF CONTENTS 1 INTRODUCTION SHIPPING... 1

HDLV 55-Gallon Powder Drum Unloader

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

NHR-25 Feed Hopper with Agitator

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10

SAFETY INFORMATION AND WARNINGS

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Eclipse Self-Check UV Scanner

Power Supply Display Module PSDM. Installation and Operation Manual

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Model 3300 Technical Support and Installation Manual

XC-18. NOTE: *Machine shown without Lift-Up Safety Guard. This guard is included with machine. Machine should not be operated without this guard.

Replacing a Gun Thermostat

AIR LINE HEATER / FILTER HEATER MODEL: A13230

Models: GW/R-T GW/R-2-T GW/R-3-T

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Required Tools The following tools are required for the installation of the kit: Open-end Wrench Set Flat-tip Screwdriver Cross-tip Screwdriver

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

MBCE-110/230UV Flame Sensor Module

Page 1 of 18. Part# /5/2013

Installation Instructions

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

Non-RTD Hot Melt Hose Replacement

Rhino SD2/XD2 ARW Air Circuit Module for 125-mm Frames

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

NH-4 Heaters. Customer Product Manual Part

Manual No: Revision: E. Groundwater Sensor. Installation Guide

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

Installation Instructions

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Viking Installation Guide

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

Installation Requirements for Models:

SHOPSMITH DC-330L DUST COLLECTOR OWNER S MANUAL. For more information: For Question or Support: (937)

PILEJOGGER II MODELS: PJ2A PJ2AIE Operating Instructions (ENG) Read instructions before operating the machine.

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

690 Power Fishing System

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Installation Instructions

Design Manual Installation Operation Maintenance

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

PWASH Gallon Parts Washer Assembly & Operating Instructions

60In. Ceiling Fan. Owner s Manual

TE 1000-AVR. English. Printed: Doc-Nr: PUB / / 000 / 04

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

R100 Oil-Less Refrigerant Recovery Unit

TE 2 TE 2-M TE 2-S. English Français Español Português

BG8SS. 8 Inch Slow Speed Bench Grinder with LED Lights Assembly & Operating Instructions

model No: ir20.v2 FUSE

Service Manual Model 3163

BG6UL. 6 Inch Bench Grinder Assembly & Operating Instructions

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Installation Instructions

9060 Power Supply Kit for External Cascade

55-Gallon Dispenser Package

3.5-GALLON PARTS WASHER OWNER S MANUAL

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Installation Instructions

INSTALLATION & MAINTENANCE

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

MARTIN Insertable Dust Collector

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

WALLPAPER STEAMER. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

User Manual Box Exhaust Fan Series (Belt Drive)

Chapter 18 Welding Table of Contents

STAR-MAX PROPANE GAS GRIDDLE

TE 40 TE 40-AVR English

Installation Instructions. Mira LED Light System

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

English. Your Model Number is: HD1500 IMPORTANT

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

Operation Manual RANGE HOOD

Inverter Split-type Room Air Conditioner

SLT-Series Installation and maintenance instructions

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Transcription:

FC-2200 Flame Detector Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA

Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence to Nordson Corporation 555 Jackson Street Amherst, OH 44001 Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date 1997. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks 100 Plus, Blue Box, ChromaFlex, CleanSleeve, CleanSpray, Control Coat, Cross-Cut, Easy Coat, Econo-Coat, Excel 2000, Flow Sentry, Isocoil, Isocore, Iso-Flo, Nordson, the Nordson logo, PRX, Pro-Flo, RBX, Ready-Coat, Rhino, Select Coat, Select Cure, Shur-Lok, Smart Spray, System Sentry, Thread Coat, Tribomatic, and Versa-Spray are registered trademarks of Nordson Corporation. CPX, CanWorks, Excel 2000, PowderGrid, Pulse Spray, SCF, Versa-Coat, Versa Screen, Package of Values, and Swirl Coat are trademarks of Nordson Corporation. PyroLink is a registered trademark of Fire Combat Corporation 1998 Nordson Corporation

Table of Contents i Table of Contents 1. Safety..................................................... 1 Safety Symbols........................................... 1 Qualified Personnel....................................... 2 Intended Use............................................. 3 Installation............................................... 3 Operation................................................ 5 Less-Obvious Dangers.................................... 7 Action in the Event of a Malfunction......................... 7 Maintenance and Repair................................... 7 Disposal................................................. 9 2. Description................................................ 10 Controller............................................... 11 Flame Sensors.......................................... 11 Test Lights.............................................. 11 Specifications........................................... 12 Controller............................................. 12 Flame Sensor......................................... 12 Test Light............................................. 12 Controller Input Voltage................................ 12 Controller Output Voltage............................... 12 Alarm Buzzer Sound Level.............................. 12 3. Installation................................................ 13 Mounting............................................... 13 Electrical Connections.................................... 16 Pneumatic Connections.................................. 18 1998 Nordson Corporation

ii Table of Contents 4. Operation................................................. 18 WARNING Alarm........................................ 19 FAULT Alarm............................................ 19 FIRE Alarm............................................. 20 Alarm Silence........................................... 20 5. Maintenance............................................... 20 6. Troubleshooting............................................ 21 Introduction............................................. 21 Troubleshooting Tables................................... 22 Controller Wiring Diagram................................. 25 7. Repair.................................................... 26 Flame Sensor........................................... 26 Test Light............................................... 28 System Controller........................................ 30 8. Introduction................................................ 32 Using the Illustrated Parts List............................. 32 FC-2200 Components.................................... 33 Controller Parts.......................................... 35 Flame Sensor Parts...................................... 37 Test Light Parts.......................................... 39 1998 Nordson Corporation

FC-2200 Flame Detector 1 FC-2200 Flame Detector 1. Safety This section contains general safety instructions for using your Nordson equipment. Task- and equipment-specific warnings are included in other sections of this manual where appropriate. Note all warnings and follow all instructions carefully. Failure to do so may result in personal injury, death, or property damage. To use this equipment safely, read and become familiar with the general safety instructions provided in this section of the manual before installing, operating, maintaining, or repairing this equipment. read and carefully follow the instructions given throughout this manual for performing specific tasks and working with specific equipment. store this manual within easy reach of personnel installing, operating, maintaining, or repairing this equipment. follow all applicable safety procedures required by your company, industry standards, and government or other regulatory agencies. Refer to the National Fire Protection Association (NFPA) standard 33 and to federal, state, regulatory agency, and local codes for rules and regulations covering installation and operation of powder spray systems. obtain and read Material Safety Data Sheets (MSDS) for all materials used. Safety Symbols Become familiar with the safety symbols presented in this section. These symbols will alert you to safety hazards and conditions that may result in personal injury, death, or property and equipment damage. WARNING: Failure to observe this warning may result in personal injury, death, or equipment damage. 1998 Nordson Corporation

2 FC-2200 Flame Detector Safety Symbols (contd.) WARNING: Risk of electrical shock. Failure to observe this warning may result in personal injury, death, or equipment damage. WARNING: Disconnect equipment from line voltage. Failure to observe this warning may result in personal injury, death, or equipment damage. WARNING: Risk of explosion or fire. Fire, open flames, and smoking prohibited. WARNING: Wear protective clothing, safety goggles, and approved respiratory protection. Failure to observe may result in serious injury. WARNING: System or material pressurized. Relieve pressure. Failure to observe this warning may result in serious injury or death. CAUTION: Failure to observe may result in equipment damage. Qualified Personnel Qualified personnel is defined here as individuals who thoroughly understand the equipment and its safe operation, maintenance, and repair. Qualified personnel are physically capable of performing the required tasks, familiar with all relevant safety rules and regulations, and have been trained to safely install, operate, maintain, and repair the equipment. It is the responsibility of the company operating the equipment to see that its personnel meet these requirements. 1998 Nordson Corporation

FC-2200 Flame Detector 3 Intended Use WARNING: Use of this equipment in ways other than described in this manual may result in personal injury, death, or property and equipment damage. Use this equipment only as described in this manual. Nordson Corporation cannot be responsible for injuries or damages resulting from nonstandard, unintended applications of its equipment. This equipment is designed and intended only for the purpose described in this manual. Uses not described in this manual are considered unintended uses and may result in serious personal injury, death, or property damage. Unintended uses may result from taking the following actions: making changes to equipment that have not been recommended or described in this manual or using parts that are not genuine Nordson replacement parts failing to make sure that auxiliary equipment complies with approval agency requirements, local codes, and all applicable safety standards using materials or auxiliary equipment that are inappropriate or incompatible with your Nordson equipment allowing unqualified personnel to perform any task Installation Read the installation section of all system component manuals before installing your equipment. A thorough understanding of system components and their requirements will help you install the system safely and efficiently. Allow only qualified personnel to install Nordson and auxiliary equipment. Use only approved equipment. Using unapproved equipment in an approved system may void agency approvals. Make sure all equipment is rated and approved for the environment in which you are using it. Follow all instructions for installing components and accessories. Install all electrical, pneumatic, gas, and hydraulic connections to local code. 1998 Nordson Corporation

4 FC-2200 Flame Detector Installation (contd.) Install locking, manual, shutoff valves in the air supply lines to the system. This allows you to relieve air pressure and lock out the pneumatic system before undertaking maintenance and repairs. Install a locking disconnect switch or breaker in the service line ahead of any electrical equipment. Use only electrical wire of sufficient gauge and insulation to handle the rated current demand. All wiring must meet local codes. Ground all electrically conductive equipment within 10 feet (3 meters) of the spray area. Ungrounded conductive equipment can store a static charge which could ignite a fire or cause an explosion if a hot spark is discharged. Route electrical wiring, electrostatic cables, and air hoses and tubing along a protected path. Make sure they will not be damaged by moving equipment. Do not bend electrostatic cables around a radius of less than 6 in. (152 mm). Install safety interlocks and approved, fast-acting fire detection systems. These shut down the spray system if the booth exhaust fan fails, a fire is detected, or other emergency situation develops. Make sure the spray area floor is conductive to ground and that the operator s platform is grounded. Use only designated lifting points or lugs to lift and move heavy equipment. Always balance and block loads when lifting to prevent shifting. Lifting devices must be inspected, certified, and rated for a greater weight than the equipment being lifted. Protect components from damage, wear, and harsh environmental conditions. Allow ample room for maintenance, material supply container drop-off and loading, panel accessibility, and cover removal. If safety devices must be removed for installation, install them immediately after the work is completed and check them for proper functioning. 1998 Nordson Corporation

FC-2200 Flame Detector 5 Operation Only qualified personnel, physically capable of operating the equipment and with no impairments to their judgement or reaction times, should operate this equipment. Read all component manuals before operating a powder spray system. A thorough understanding of all components and their operation will help you operate the system safely and efficiently. Use this equipment only in the environments for which it is rated. Do not operate this equipment in humid, flammable, or explosive environments unless it has been rated for safe operation in these environments. Before starting this equipment, check all safety interlocks, fire-detection systems, and protective devices such as panels and covers. Make sure all devices are fully functional. Do not operate the system if these devices are not working properly. Do not deactivate or bypass automatic safety interlocks or locked-out electrical disconnects or pneumatic valves. Know where EMERGENCY STOP buttons, shutoff valves, and fire extinguishers are located. Make sure they work. If a component malfunctions, shut down and lock out the equipment immediately. Before operating, make sure all conductive equipment in the spray area is connected to a true earth ground. Never operate equipment with a known malfunction or leak. Do not attempt to operate electrical equipment if standing water is present. Never touch exposed electrical connections on equipment while the power is ON. Do not operate the equipment at pressures higher than the rated maximum working pressure of any component in the system. Know the pinch points, temperatures, and pressures for all equipment that you are working with. Recognize potential hazards associated with these and exercise appropriate caution. Wear shoes with conductive soles, such as leather, or use grounding straps to maintain a connection to ground when working with or around electrostatic equipment. 1998 Nordson Corporation

6 FC-2200 Flame Detector Operation (contd.) Do not wear or carry metallic objects (jewelry or tools) while working with or around electrostatic equipment. Ungrounded metal can store a static charge and cause harmful shocks. Maintain skin-to-metal contact between your hand and the gun handle to prevent shocks while operating manual electrostatic spray guns. If wearing gloves, cut away the palm or fingers. Keep parts of the body or loose clothing away from moving equipment or parts. Remove personal jewelry and cover or tie back long hair. Wear National Institute of Occupational Safety and Health (NIOSH) approved respirators, safety glasses or goggles, and gloves, and while handling powder containers, filling hoppers, operating spray equipment, and performing maintenance or cleaning tasks. Avoid getting powder coatings on your skin. Never point manual guns at yourself or other persons. Do not smoke in the spray area. A lit cigarette could ignite a fire or cause an explosion. If you notice electrical arcing in a spray area, shut down the system immediately. An arc can cause a fire or explosion. Shut off electrostatic power supplies and ground gun electrodes before making adjustments to powder spray guns. Shut off moving equipment before taking measurements or inspecting workpieces. Wash exposed skin frequently with soap and water, especially before eating or drinking. Do not use solvents to remove coating materials from your skin. Do not use high-pressure compressed air to blow powder off your skin or clothes. High-pressure compressed air can be injected under the skin and cause serious injury or death. Treat all high-pressure fittings and hoses as if they could leak and cause injury. 1998 Nordson Corporation

FC-2200 Flame Detector 7 Less-Obvious Dangers Operators should also be aware of less-obvious dangers in the workplace that often cannot be completely eliminated: exposed surfaces on the equipment which may be hot or have sharp edges and cannot be practically safeguarded electrical equipment which may remain energized for a period of time after the equipment has been shut off vapors and materials which may cause allergic reactions or other health problems automatic hydraulic, pneumatic, or mechanical equipment or parts that may move without warning unguarded, moving mechanical assemblies Action in the Event of a Malfunction Do not operate a system that contains malfunctioning components. If a component malfunctions, turn the system OFF immediately. Disconnect and lock out electrical power. Close and lock out hydraulic and pneumatic shutoff valves and relieve pressures. Allow only qualified personnel to make repairs. Repair or replace the malfunctioning component. Maintenance and Repair Allow only qualified personnel to perform maintenance, troubleshooting, and repair tasks. Always wear appropriate protective devices and use safety devices when working on this equipment. Follow the recommended maintenance procedures in your equipment manuals. Do not service or adjust any equipment unless another person trained in first aid and CPR is present. Use only genuine Nordson replacement parts. Using unapproved parts or making unapproved modifications to equipment may void agency approvals and create safety hazards. 1998 Nordson Corporation

8 FC-2200 Flame Detector Maintenance and Repair (contd.) Disconnect, lock out, and tag electrical power at a disconnect or breaker in the service line ahead of electrical equipment before servicing. Do not attempt to service electrical equipment if there is standing water present. Do not service electrical equipment in a high-humidity environment. Use tools with insulated handles when working with electrical equipment. Do not attempt to service a moving piece of equipment. Shut off the equipment and lock out power. Secure equipment to prevent uncontrolled movement. Relieve air pressures before servicing equipment. Follow the specific instructions in this manual. Make sure that the room where you are working is sufficiently ventilated. If a power on test is required, perform the test carefully and then shut off and lock out power as soon as the test is over. Connect all disconnected equipment ground cables and wires after servicing the equipment. Ground all conductive equipment. Service lines connected to panel disconnect switches may still be energized unless they are disconnected. Make sure the power is off before servicing. Wait 5 minutes for capacitors to discharge after shutting off the electrical power. Turn off the electrostatic power supply and ground the gun electrode before adjusting or cleaning. Keep high-voltage connection points clean and insulated with dielectric grease or oil. Check all ground connections periodically with a standard ohmmeter. Resistance to ground must not exceed one megohm. If arcing occurs, shut down the system immediately. 1998 Nordson Corporation

FC-2200 Flame Detector 9 Check interlock systems periodically to ensure their effectiveness. WARNING: Operating faulty electrostatic equipment is hazardous and can cause electrocution, fire, or explosion. Make resistance checks part of your periodic maintenance program. Do not store flammable materials in the spray area or room. Keep containers of flammable materials far enough away from spray booths to prevent their inclusion in a booth fire. If a fire or explosion occurs, flammable materials in the area will increase the chances and the extent of personal injuries and property damage. Practice good housekeeping procedures. Do not allow dust or powder coatings to accumulate in the spray area or booth or on electrical equipment. Read this information carefully and follow instructions. Disposal Dispose of equipment and materials used in operation and cleaning according to your local regulations. 1998 Nordson Corporation

10 FC-2200 Flame Detector 2. Description The Nordson FC-2200 flame detector is a microcomputer-based flame detection device used with automatic powder coating systems. The flame detector consists of a controller, two flame sensors, and two test lights. The sensors and test lights are connected to the controller by twoand six-conductor shielded cables. One FC-2200 flame detector is required for each spray booth. The spray booth and conveyor are interlocked with the flame detector through a relay board in the controller. The automatic powder application equipment is interlocked with the spray booth. The FC-2200 flame detector monitors itself for malfunctions and the inside of the booth for arcs and fires. The control unit initiates audible and visible WARNING, FAULT, or FIRE alarms, depending on what it detects. A WARNING alarm is audible only, to notify the operator that a problem has been detected. A FAULT alarm will shut down the spray booth and powder application equipment. A FIRE alarm will shut down the spray booth, powder application equipment, and conveyor. Refer to the Operation section for more information on alarms. 1 2 3 Fig. 1 FC-2200 Flame Detector 1. Controller 2. Flame sensors 3. Test lights 3438001B 1998 Nordson Corporation

FC-2200 Flame Detector 11 Controller The controller is contained in a NEMA 4 weather-proof steel enclosure. Two seven-segment numerical displays and four LEDs show system status and fault codes. A buzzer on the front panel sounds when the controller initiates an alarm. The enclosure houses a DC power supply board, a circuit board set, and terminal blocks. A free, normally open relay (fault relay) closed by a fault alarm is included. This relay can be used to operate additional alarm devices. Flame Sensors The flame sensors are enclosed in IP-65/DIN 40-050 (watertight) NEMA/EEMAC enclosures. Each enclosure contains sensors that detect ultraviolet (UV) and infrared (IR) radiation given off by burning hydrocarbons or electrostatic arcs. When the sensors detect UV or IR radiation, they send signals to the controller that correspond to the type and intensity of the radiation. The controller processes the signals and compares the results to known values stored in its memory. The controller may then initiate an alarm. If the sensors detect only UV radiation, the controller will initiate a Warning alarm. Both UV radiation and IR radiation must be present before the controller will initiate a FIRE alarm. An air shroud is installed around the sensor lenses. A constant flow of low-pressure air through the air shroud helps keep the lenses clean. Test Lights The test lights are enclosed in IP-65/DIN 40-050 (watertight) NEMA/EEMAC enclosures. Each enclosure contains a circuit board and a UV light bulb. The FC-2200 flame detector performs an external test by turning on the test lights at set time intervals. To pass the test, the sensors must see the UV radiation emitted by the test lights and send the correct signal back to the controller. This test ensures that the sensors are working properly and that their view of the interior of the booth is not blocked. An air shroud is installed around the test light lens. A constant flow of low-pressure air through the air shroud helps keep the lens clean. 1998 Nordson Corporation

12 FC-2200 Flame Detector Specifications For more information, contact your Nordson representative. Controller Weight: Dimensions: (Height x Width x Depth) 7701 g (17 lb) 152 mm x 279 mm x 343 mm (6 in. x 11 in. x 13.5 in.) Sensor Weight: Dimensions: (Height x Width x Depth) 1359 g (3 lb) 152 mm x 152 mm x 152 mm (6 in. x 6 in. x 6 in.) Test Light Weight: Dimensions: (Height x Width x Depth) 1132.5 g (2.5 lb) 152 mm x 152 mm x 152 mm (6 in. x 6 in. x 6 in.) Controller Input Voltage 100 240 Vac, 2A, 50/60 Hz Controller Output Voltage To Sensors: To test lights: 9 30 Vdc, 120 ma 100 240 Vac, 2A, 50/60 Hz Alarm Buzzer Sound Level 109 db at 0.6 m (2 ft) 1998 Nordson Corporation

FC-2200 Flame Detector 13 3. Installation WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. Mounting 1. See Figure 2 and refer to Table 1 to determine the approximate locations for the test lights and flame sensors. Note that while the flame sensors have a 90 field of view, the test lights only emit UV radiation over a 60 field of view. Mount the flame sensors and test lights as follows: The test lights must be mounted no more than 3.7 m (12 ft) from the sensors, at no more than a 30 angle from the sensor centerlines. The sensors must be aimed so that their centerlines are pointed at the spray guns and workpiece hangers. Table 1 Sensor and Test Light Locations If dimension W is: (mm (in.)) Then dimension X is: (mm (in.)) 305 (12) 127 (5) 457 (18) 203 (8) 610 (24) 279 (11) 762 (30) 381 (15) 914 (36) 457 (18) 1067 (42) 559 (22) 1219 (48) 635 (25) 1372 (54) 711 (28) 1524 (60) 787 (31) 1676 (66) 889 (35) 1829 (72) 965 (38) 1981 (78) 1041 (41) 2134 (84) 1143 (45) 2286 (90) 1219 (48) 2438 (96) 1295 (51) 1998 Nordson Corporation

14 FC-2200 Flame Detector Mounting (contd.) 76.2 mm (3 in.) 2 CL 3 3 W CL CL C L 152.4 mm (6 in.) 1 X 1 X Top View Side View 3.6 m (12 ft) maximum 1 3 2 2 3 Booth Top View Fig. 2 Determining Sensor and Test Light Locations 1. Test lights 2. Flame sensors 3. Booth vestibules 1 3438002A 1998 Nordson Corporation

FC-2200 Flame Detector 15 2. See Figure 3. Use the test-light mounting plates as templates to mark drill points on the booth vestibule walls. Drill a 77-mm (3-in.) hole for the lens and 6-mm ( 1 / 4 -in.) holes for the mounting screws. 3. Mount the test lights as shown with the screws and mounting plate. 4. Mount the sensors in the booth vestibules as shown with the included fasteners and brackets. 5 11 1 6 Fig. 3 Mounting Sensors and Test Lights 1. Test light 2. Vestibule wall 3. Mounting plate 4. Screws 2 3 4 5. Flame sensor 6. Bracket 7. Flat washer 8. Lock washer 7 8 9 9. Nut 10. Vestibule floor 11. Hex screw 10 3438003A 5. Mount the controller in an appropriate location, using 5 / 16 -inch fasteners. The controller is usually mounted to a bracket on the operator platform railing, next to the spray booth electrical panel. 1998 Nordson Corporation

16 FC-2200 Flame Detector Electrical Connections Electrical connections are shown in Figure 4. A system wiring diagram is also glued to the inside of the controller door. WARNING: Shut off system electrical power before making electrical connections. Failure to observe this warning may result in equipment damage, personal injury, or death. Use these guidelines when connecting the flame sensors and test lights to the controller: Use 6-conductor shielded cable to connect the flame sensors to the controller. Use 2-conductor shielded cable to connect the test lights to the controller. Install the cables in flexible metal conduit and use waterproof conduit connectors. Refer to the Parts section for the cable part numbers. Power supply wiring and interlock relay (fault, conveyor, booth) must conform to local electrical codes. Use flexible metal conduit and waterproof conduit connectors. Remove the flame sensor and test light enclosure covers to connect the cables. Refer to the Repair section for instructions. A free, normally open relay (fault relay) is connected to terminals 31 and 32 on the controller terminal block. Use this relay to operate additional alarm devices if necessary. The relay closes on a fault alarm. 1998 Nordson Corporation

FC-2200 Flame Detector 17 Controller Terminal Block 100 240 Vac AC NEUTRAL EARTH GROUND NOTE: CONNECT BLACK WIRE TO 220V TERMINAL ONLY IF SYSTEM IS POWERED BY 220Vac 220V 110V NEUT. EARTH GND CASE SCREW Test Light A 220V 110V NEUT. EARTH GND CASE SCREW Test Light B Fig. 4 TB2 TB1 1 9 30VDC 8 2 SWITCHED(+) ALARM OUT 7 PYROLINK TEST IN 3 6 NETWORK ( ) DIRECT OUT 4 SYSTEM( ) 5 5 PYROLINK EARTH 4 NETWORK (+) GROUND 6 N.C. K1 K2 N.C. 3 7 COM 8 N.O. FAULT ALARM COM 2 N.O. 1 Wiring Diagram Sensor A TB2 TB1 1 9 30VDC 8 2 SWITCHED(+) ALARM OUT 7 PYROLINK TEST IN 3 6 NETWORK ( ) DIRECT OUT 4 SYSTEM( ) 5 PYROLINK EARTH 5 4 NETWORK (+) GROUND 6 N.C. K1 K2 N.C. 3 7 COM 8 N.O. FAULT ALARM COM 2 N.O. 1 Sensor B 3438004B 1998 Nordson Corporation

18 FC-2200 Flame Detector Pneumatic Connections A constant flow of air at 1 bar (15 psi) is required to help keep the flame sensor and test light lenses clean. Refer to the Parts section for regulator, tubing, and fitting part numbers. 1. Install the 10-mm x 1 / 4 -NPT connectors in the regulator input ports and the 6-mm x 1 / 4 -NPT tees in the output ports. 2. Route 6-mm air tubing from the tees to the elbow fittings on the detector and test light air shrouds. 3. Route 10-mm air tubing from the regulator connectors to a 10-mm tubing connector in the booth pneumatic panel. Make sure air is supplied to the regulators at system pressure. 4. Operation WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. See Figure 5. The FC-2200 flame detector displays any system faults on its digital display located on the front of the control panel. The left digit shows the status of sensor A and the right digit shows the status of sensor B. Read the fault codes following these examples: Fig. 5 System Fault Digital Display 3438012A Fault Code Problem 01 Arc detected on sensor B; sensor A is operating normally 30 Sensor A failed external test; sensor B is operating normally 55 Power loss on both sensors The FC-2200 flame detector has no power switch. It turns on when the spray booth power is turned on. When the flame detector is operating normally the green POWER LED is on all other LEDs are off the numerical display shows 00 WARNING: Do not operate the coating system with the FC-2200 flame detector shut down, bypassed, or with a known malfunction. Failure to observe this warning may result in equipment damage, personal injury, or death. 1998 Nordson Corporation

FC-2200 Flame Detector 19 WARNING Alarm WARNING: IImmediately find and fix any malfunction that initiates a WARNING alarm. Failure to observe this warning may result in equipment damage, personal injury, or death. A WARNING alarm is initiated if an arc is detected or a system component malfunctions. Refer to the Troubleshooting section for information on diagnosing and correcting malfunctions. When a WARNING alarm is initiated the yellow WARNING LED turns on buzzer sounds for 1 second at 5 second intervals spray booth, application equipment, and conveyor continue to operate numerical display shows one of the following fault codes: Fault Code Problem 1 Arc detected in booth or conveyor 2 Dirty sensor lens 3 Failed external test 4 Communications link (current loop) with one sensor broken 5 Power loss to one sensor FAULT Alarm WARNING: Immediately find and fix any malfunction that initiates a FAULT alarm. Do not restart the coating system until repairs are made. Failure to observe this warning may result in equipment damage, personal injury, or death. A FAULT alarm is initiated if a component malfunction disables the FC-2200 flame detector. Immediately find and fix the problem. Refer to the Troubleshooting section for information on diagnosing and correcting malfunctions. When a FAULT alarm is initiated the blue FAULT LED turns on buzzer sounds for one (1) second at one (1) second intervals spray booth and application equipment shuts down; the conveyor continues to operate numerical display shows one of the following fault codes: Fault Code Problem 44 Communications links (current loops) with both sensors broken 55 Power loss to both sensors 1998 Nordson Corporation

20 FC-2200 Flame Detector FIRE Alarm WARNING: Do not disregard a FIRE alarm. Immediately take action to extinguish the fire. Failure to observe this warning may result in equipment damage, personal injury, or death. A FIRE alarm is initiated if the system detects a fire in the booth. Respond to the alarm immediately. When a FIRE alarm is initiated the red FIRE LED turns on buzzer sounds continuously spray booth, application equipment, and conveyor shuts down numerical display shows a 99 fault code Alarm Silence To silence the buzzer, open the controller door. Press and release the red reset button on the power supply board cover. The button is clearly labeled. If you have fixed the malfunction, the green POWER LED will turn on, and the WARNING, FAULT, or FIRE LED will turn off. If you did not fix the malfunction, the buzzer will go off again. 5. Maintenance Maintenance is limited to the following procedures. Inspect the flame sensor and test light lenses daily. Clean the lenses with compressed air or a clean, dry cloth. Use a soft cloth soaked with isopropyl alcohol to remove any stubborn deposits. Make sure the sensor and test light air shrouds are supplied with compressed air and the shroud orifices are clear. Air must be clean and dry. Visually check all electrical conduit and wiring. Make sure that all electrical connections are secure and the enclosures are sealed. Make sure the sensors can see the test lights at all times. 1998 Nordson Corporation

FC-2200 Flame Detector 21 6. Troubleshooting WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. Introduction WARNING: Immediately correct any problem that causes the system to initiate a WARNING or FAULT alarm. Do not operate the coating system if the FC-2200 flame detector is malfunctioning, shut down, or bypassed. WARNING: Hazardous voltages are present during testing procedures. Serious injury or death may result if personnel fail to observe standard safety precautions. CAUTION: Printed circuit boards are susceptible to damage from static discharge. Make sure you are electrically grounded before handling printed circuit boards. This section contains troubleshooting procedures. These procedures cover only the most common problems that you may encounter. If you cannot solve the problem with the information given here, contact your local Nordson representative for help. 1998 Nordson Corporation

22 FC-2200 Flame Detector Troubleshooting Tables See Figures 4 and 6 for terminal locations and wiring diagrams. Refer to the Repair section for controller, flame sensor, and test light disassembly instructions. After making repairs, turn on spray booth power. When the green LED lights, press the reset button on the power supply board to reset the FC-2200 flame detector. Table 2 Problem Diagnosis and Correction Problem Possible Cause Corrective Action No power (green LED not lit) No input power Check for the correct input voltage at controller terminals L1 and L2. If no voltage is present, check the wiring to the controller. If voltage is present, check for a blown fuse. Fuse blown Check for +12 Vdc at controller terminals 11 and 12. If no voltage is present, replace the fuse on the power supply board. If voltage is present, check for a failed power supply board. Faulty power supply board Faulty controller circuit board Turn off power and disconnect the connector at CN2 on the power supply board. Turn on power and check for 5 Vdc between CN2 pins 4 and 2, +12 Vdc between pins 4 and 1, and -12 Vdc between pins 5 and 6. If any of these voltages are incorrect, replace the power supply board. If all voltages are correct, turn off power and reconnect the CN2 connector. Check for a faulty sensor or cable. Contact your Nordson representative. 1998 Nordson Corporation

FC-2200 Flame Detector 23 Table 3 Fault Code Diagnosis and Correction Fault Code Possible Cause Corrective Action 1 Significant UV event (spark or arcing) detected without a fire being detected Check for ungrounded part(s) on conveyor, sticking conveyor chain link, damaged gun, or any ungrounded objects in the booth. 2 One or more sensor lens are dirty Clean the lenses on both sensors. Make sure the air shrouds are supplied with compressed air. 3 One sensor has failed the external test One of the sensors did not see the test lights. Clean the sensor lenses and make sure the sensors are aligned properly. If this does not solve the problem, make sure the test lights are working. Open the controller door and press the reset button while a co-worker watches the test lights for a brief flash of UV light. Repair the test lights if they are not working. Repair or replace the sensors if the problem persists. 4 Communications link (current loop) between one sensor and controller is broken Check the sensor cable connections. If all connections are good, check the continuity of the cable leads. Repair or replace the cable if one of the leads is open or shorted. Repair or replace the sensor if the cable is good. 5 No power to one sensor See if the red LED by the sensor s UV tube is flashing. Check for +12 Vdc between terminal block pins 11 and 12 and between pins 21 and 22. If voltage is present, check the continuity of the cable leads. Repair or replace the cable if one of the leads is open or shorted. Repair or replace the sensor if the cable is good. Continued on next page 1998 Nordson Corporation

24 FC-2200 Flame Detector Troubleshooting Tables (contd.) Fault Code Possible Cause Corrective Action 33 Both sensors have failed the external test Neither of the sensors saw the test lights. Clean the sensor lenses and make sure the sensors are aligned properly. If this does not solve the problem, make sure the test lights are working. Open the controller door and press the reset button while a co-worker watches the test lights for a brief flash of UV light. Repair the test lights if they are not working. Repair or replace the sensors if the problem persists. 44 Communications links (current loop) between both sensors and controller are broken Check the sensor cable connections. If all connections are good, check the continuity of the cable leads. Repair or replace the cables if any of the leads is open or shorted. Repair or replace the sensors if the cables are good. 55 Power loss to both sensors See if the red LED by the sensor s UV tube is flashing. Check for +12 Vdc between terminal block pins 11 and 12 and between pins 21 and 22. If voltage is present, check the continuity of the cable leads. Repair or replace the cables if any of the leads are open or shorted. Repair or replace the sensors if the cables are good. 99 FIRE alarm UV and IR light detected. 1998 Nordson Corporation

FC-2200 Flame Detector 25 Controller Wiring Diagram B N 68Hc11 Board Com. Board V V S S Buzzer C C Relay #2 Connector 34 34 #1 Connector 5 A B J15 NO C NC 1 2 3 NO Test Light Relay Relay Board Fault Relay 4 Conv. Relay 5 Booth Relay C NC NO C NC NO C NC NO C NC V S C 34 Display Board VDC Ribbon Cable Current Converter A T+ T G R+ R Buzzer +VDC Red Terminal Current Converter B T+ T G R+ R CN2 1 2 3 4 5 6 Power Supply Reset Push Button FG CN1 L1 L2 Fuse 100 to 240 Vac GND Test Light A Test Light B GND +12 VDC System ( ) Sensor A Comm. Sensor A Alarm GND +12 VDC System ( ) Sensor B Comm. Sensor B Alarm GND Fault Relay Conveyor Relay Booth Relay 3438005D Fig. 6 Controller Wiring Diagram 1998 Nordson Corporation

26 FC-2200 Flame Detector 7. Repair WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation. WARNING: Disconnect, lock out, and tag electrical power before servicing any component of the FC-2200 flame detector. Failure to observe this warning could result in personal injury or death. CAUTION: Printed circuit boards and electronic components are susceptible to damage from static discharge. Make sure you are electrically grounded before handling printed circuit boards. NOTE: After making repairs, turn on power. When the green LED lights, open the controller door and press the reset button to reset the system. Flame Sensor Follow this procedure to disassemble the flame sensor so you can replace serviceable parts. 1. See Figure 7. Remove the two screws (6), lock washers (7), and flat washers (8). Remove the sensor from the bracket (9). 2. Remove the four screws (10), the air shroud (11), and the gasket (5) from the cover (3). 3. Unscrew the four screws (12) in the corners of the cover. The screws are captive. Do not remove them from the cover. 4. Carefully separate the body (1) from the cover. Be careful not to damage the sensor module (2). 5. Remove the two screws (4) securing the sensor module to the cover. Gently remove the sensor module from the cover. The module is not a serviceable part. 6. Be careful not to touch the sensors on the sensor module. If you accidentally touch them, gently wipe off any fingerprints with a silicone- and oil-free cloth. Reverse the disassembly steps to reassemble the flame sensor. Make sure the cover O-ring is properly installed. 1998 Nordson Corporation

FC-2200 Flame Detector 27 12 1 11 2 10 3 4 5 7 8 9 6 3438006A Fig. 7 Flame Sensor Disassembly 1. Body 2. Sensor module 3. Cover 4. Screws 5. Gasket 6. Screws 7. Lock washers 8. Flat washers 9. Bracket 10. Screws 11. Air shroud 12. Captive screws 1998 Nordson Corporation

28 FC-2200 Flame Detector Test Light Follow this procedure to disassemble the test lights so you can replace serviceable parts. 1. See Figure 8. Remove the four screws (11) and mounting plate (10). 2. Unscrew the four screws (2) in the corners of the cover (1). The screws are captive. Do not remove them from the cover. 3. Carefully separate the cover from the body (6). 4. Disconnect the connector (4) from the terminal block on the circuit board (5). 5. Remove the two screws (3). 6. Gently remove the circuit board. Be careful not to touch the UV lamp on the board. If you accidentally touch it, gently wipe off any fingerprints with a silicone- and oil-free cloth. 7. Remove the four screws (9), air shroud (8), and gasket (7). Reverse the disassembly steps to reassemble the test light. Make sure the cover O-ring is properly installed. 1998 Nordson Corporation

FC-2200 Flame Detector 29 2 3 1 4 5 9 6 7 8 10 11 Fig. 8 Test Light Disassembly 1. Cover 2. Captive screws 3. Screws 4. Connector 5. Circuit board 6. Body 7. Gasket 8. Air shroud 9. Screws 10. Mounting plate 11. Screws 3438007A 1998 Nordson Corporation

30 FC-2200 Flame Detector System Controller See Figure 9. Follow this procedure to remove the serviceable parts of the controller. 1. Open the enclosure door. Disconnect all wiring and ribbon cables necessary to remove the component(s) you are replacing. 2. Remove the four screws (3) to remove the back panel (2) from the enclosure. 3. If you are replacing the entire board set, unscrew the screws (not shown) on the rear of the back panel that secure the standoffs (9) to the panel. 4. If you are replacing the relay board (6), display board (7), or mother board (8), unscrew the nuts from the corners of the boards. Lift the boards off the standoffs. 5. If you are replacing the power supply board, remove the cover (4). Unscrew the nuts from the corners of the board and lift the board off the standoffs. 6. To remove the buzzer (1), disconnect the wires from the buzzer terminals and unscrew the bezel from the front of the door. Remove the buzzer from the inside of the door. Reverse the disassembly steps to reassemble the controller. See Figure 6 for wiring connections. 1998 Nordson Corporation

FC-2200 Flame Detector 31 9 8 7 6 1 2 3 4 5 3438008B Fig. 9 System Controller Disassembly 1. Buzzer 2. Back panel 3. Screws 4. Cover 5. Power supply board 6. Relay board 7. Display board 8. Mother board 9. Standoffs 1998 Nordson Corporation

32 FC-2200 Flame Detector 8. Parts To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use this five-column parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts List Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list. The code NS (not shown) indicates that a listed part is not illustrated. A dash ( ) is used when the part number applies to all parts in the illustration. The six-digit number in the Part column is the Nordson Corporation part number. A series of dashes in this column (- - - - - -) means the part cannot be ordered separately. The Description column gives the part name, as well as its dimensions and other characteristics when appropriate. Indentions show the relationships between assemblies, subassemblies, and parts. Item Part Description Quantity Note 000 000 Assembly 1 1 000 000 Subassembly 2 A 2 000 000 Part 1 If you order the assembly, items 1 and 2 will be included. If you order item 1, item 2 will be included. If you order item 2, you will receive item 2 only. The number in the Quantity column is the quantity required per unit, assembly, or subassembly. The code AR (As Required) is used if the part number is a bulk item ordered in quantities or if the quantity per assembly depends on the product version or model. Letters in the Note column refer to notes at the end of each parts list. Notes contain important information about usage and ordering. Special attention should be given to notes. 1998 Nordson Corporation

FC-2200 Flame Detector 33 FC-2200 Components See Figure 10. Item Part Description Quantity Note 183 481 Detector, flame, FC-2200, 1 booth 1 1 183 435 Controller, system, FC-2200 1 2 183 436 Sensor, flame, FC-2200 2 3 183 437 Light, test, FC-2200 2 NS 183 420 Regulator, air, in-line, 15 psi 2 A NS 972 841 Connector, male, 10 mm tube x 1 / 4 in. NPT 2 A NS 971 107 Tee, male branch, 6 mm tube x 1 / 4 in. NPT 2 A NS 183 474 Cable, 2 conductor, shielded, 20 gauge AR A, B NS 183 475 Cable, 6 conductor, shielded, 20 gauge AR A, B NS 900 593 Tubing, air, polyethylene, 10 mm OD AR A, B NS 900 586 Tubing, air, polyethylene, 6 mm OD AR A, C NOTE A: Provided with new automatic booth systems. Order separately for retrofit systems. B: Order in 1-ft increments. Typically 100 ft per system. C: Order in 1-ft increments. Typically 50 ft per system. AR: As Required NS: Not Shown 1998 Nordson Corporation

34 FC-2200 Flame Detector FC-2200 Components (contd.) 1 2 3 Fig. 10 FC-2200 Flame Detector Components 3438001B 1998 Nordson Corporation

FC-2200 Flame Detector 35 Controller Parts See Figure 11. Item Part Description Quantity Note 183 435 Controller, FC-2200 1 1 183 441 Buzzer, alarm, FC-2200 1 2 183 440 Power supply, controller, FC-2200 1 NS 131 477 Fuse, fast-acting, 5 x 20 mm, 250V, 2A 1 3 183 445 Board, set, controller, with standoffs 1 4 323 983 Board, mother, FC-2200 1 5 183 439 Board, display, FC-2200 1 6 183 438 Board, relay, FC-2200 1 7 335 242 Connector, plug, 10-position 4 NS: Not Shown 1998 Nordson Corporation

36 FC-2200 Flame Detector Controller Parts (contd.) 4 3 5 6 1 2 7 3438009B Fig. 11 Controller Parts 1998 Nordson Corporation

FC-2200 Flame Detector 37 Flame Sensor Parts See Figure 12. Item Part Description Quantity Note 183 436 Sensor, flame, assembly, FC-2200 1 1 183 444 Sensor, FC-2200 1 2 183 472 Cover, sensor, with quartz lens 1 3 183 421 Gasket, air shroud, FC-2200 1 4 183 422 Shroud, air, FC-2200 1 5 982 193 Screw, pan head, slotted, M5 x 16 mm 4 6 972 126 Elbow, male, 6 mm tube x 1 / 8 in. NPT 1 7 183 423 Bracket, mounting, sensor, w/shroud 1 8 982 049 Screw, hex, cap, M8 x 25 mm 1 9 983 013 Washer, flat, M8 3 10 983 404 Washer, lock, M8 3 11 984 707 Nut, hex, M8 1 12 982 500 Screw, hex, machine, M8 x 16 mm 2 1998 Nordson Corporation

38 FC-2200 Flame Detector Flame Sensor Parts (contd.) 5 1 2 3 4 6 12 10 9 7 8 9 10 11 3438010A Fig. 12 Flame Sensor Parts 1998 Nordson Corporation

FC-2200 Flame Detector 39 Test Light Parts See Figure 13. Item Part Description Quantity Note 183 437 Light, test, assembly, FC-2200 1 1 183 446 Light, test, FC-2200 1 2 933 549 Connector, plug, 3-position 1 3 183 443 Module, UV light source 1 4 183 442 Body, test light, with quartz lens 1 5 183 421 Gasket, air shroud, FC-2200 1 6 183 422 Shroud, air, FC-2200 1 7 972 126 Elbow, male, 6 mm tube x 1 / 8 in. NPT 1 8 982 193 Screw, pan head, slotted, M5 x 16 mm 4 9 183 419 Plate, mounting, test light, FC-2200 1 10 982 793 Screw, flat head, M6 x 16 mm 4 NS 982 792 Screw, flat head, M6 x 12 mm 4 NS: Not Shown 1998 Nordson Corporation

40 FC-2200 Flame Detector Test Light Parts (contd.) 2 3 1 4 8 5 6 7 Fig. 13 Test Light Parts 9 10 3438011B 1998 Nordson Corporation