Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Similar documents
Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Burner control unit BCU 370

Burner control units BCU 480

Burner control unit BCU 370

Control valve S11T. Pilot burner ZT. Control valve S11T

Burner control units BCU 480

Burner control unit PFU 780

Industrial & Commercial Thermal BCU 580

Burner control units BCU 460, BCU 465

Safety. Operating instructions Heater GP 40 DANGER. Contents WARNING CAUTION. Edition Please read and keep in a safe place

Safety. Operating instructions Heater GP 95 DANGER. Contents WARNING CAUTION. Changes to edition Please read and keep in a safe place

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. Operating instructions Pilot burners ZAI, ZKIH DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 09.

Burner control units BCU 560, 565

Burner control units BCU 560, 565

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame Safeguards LFE10. Building Technologies HVAC Products

LAE10 LFE10. Use. Series 02

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Flame Safeguards LFE10. Building Technologies HVAC Products

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Heating controller Lago

UV Flame Supervision System

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Distributed By: M&M Control Service, INC

IMPORTANT INSTRUCTIONS READ & SAVE

Eclipse 90 UV Scanner Model A Version 1

IMPORTANT INSTRUCTIONS READ & SAVE

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

QRA10... QRA53... QRA55...

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

MBCE-110/230UV Flame Sensor Module

FIREYE FLAME SCANNERS

IMPORTANT INSTRUCTIONS READ & SAVE

Old documentation - Only for your information! Product is not available anymore!

IMPORTANT INSTRUCTIONS READ & SAVE

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Instruction Manual. Electronic gas and smoke detector GRM

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

AUR300C. Advanced Ultraviolet Burner Controller

Flameproof Manual Call Points

C Note! LGI16... Burner Controls. Building Technologies

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Flame Simulator User Manual. Publication Rev. A

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

QRA10... QRA53... QRA55...

Energy management with a system. Edition GB. Control engineering and combustion technology for comfortable heating

COMPACT FLAME CONTROLLER CFC 100

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

IMPORTANT INSTRUCTIONS READ & SAVE

Instruction Manual and Warranty

OPERATING AND INSTALLATION MANUAL

Operating Instructions. Room Temperature Controller 230/10 (4) A~ with NC contact and On/Off button

UV - flame detector dual fuel burners for intermittent burner operations

IMPORTANT INSTRUCTIONS READ & SAVE

User manual UV Flash Dry C1

QRA10... QRA53... QRA55...

Fireye FLAME SCANNERS

Distributed By: M&M Control Service, INC

Eclipse Self-Check UV Scanner

COMPACT FLAME CONTROLLER CFC 2000

Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

UV I UNIT030W / UV I UNIT055W

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

OPERATING AND INSTALLATION MANUAL

QRA10... QRA53... QRA55...

ATM Lighting sp. z o.o

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

HI Industrial Utility Heater HI Soleus Air International

LD200 / RLD400 LD200-G /RLD400-G

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Q7800H Integrated Burner Control Subpanel

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

IMPORTANT INSTRUCTIONS

FLCH4R Garage and Utility Electric Heater

Infrared Flame Detectors

Operating instructions

UNIT MUST BE ON A DEDICATED ELECTRICAL CIRCUIT. Owner s Manual Models: 02117/02678 INFRARED HEATER POLE SET

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

ELECTRIC FIREPLACE CONVERTER KIT OWNERS MANUAL Model Number: EF05-23

LFL Series Burner Flame Safeguard Control

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

OPERATING MANUAL CUSTOMER SERVICE NO

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Grohtherm Wireless! Installation Instructions Pumped

Installation & Maintenance Instructions

Transcription:

06 Elster GmbH Edition 0.6 Translation from the German 0556 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions UV sensor UVS 5 Cert. version 0.6 Contents UV sensor UVS 5... Contents... Safety.... Checking the usage... Installation... Replacement.... Wiring... Maintenance... Replacing the UV tube... Assistance in the event of malfunction... Technical data...5 Logistics...5 Certification...6 Eurasian Customs Union...6 Contact...6 Safety Please read and keep in a safe place Please read through these instructions carefully before installing or operating. Following the installation, pass the instructions on to the operator. This unit must be installed and commissioned in accordance with the regulations and standards in force. These instructions can also be found at www.docuthek.com. Explanation of symbols,,,... = Action = Instruction Liability We will not be held liable for damage resulting from non-observance of the instructions and non-compliant use. Safety instructions Information that is relevant for safety is indicated in the instructions as follows: DANGER Indicates potentially fatal situations. Indicates possible danger to life and limb. CAUTION Indicates possible material damage. All interventions may only be carried out by qualified gas technicians. Electrical interventions may only be carried out by qualified electricians. Conversion, spare parts All technical changes are prohibited. Only use OEM spare parts. -

Checking the usage UV sensor for intermittent operation for flame control on gas burners in conjunction with Elster Kromschröder automatic burner control units (IFS, IFD, PFS, PFD), flame detectors (IFW, PFF) or burner control units (BCU, PFU). This function is only guaranteed when used within the specified limits see page 5 (Technical data). Any other use is considered as non-compliant. Type code Code Description UVS UV sensor 5 Series 5 Electrical connection: G M0 cable gland Part designations The UV sensor may only be exposed to the UV light of its own flame. It should be protected from other sources of ultraviolet light, e.g. neighbouring flames (this must be observed when monitoring pilot and main burners in particular), ignition sparks, arcs from welding devices or lamps emitting ultraviolet light. Avoid exposing the UV sensor viewing openings to direct sunlight. Protect the viewing openings against dirt and moisture. Direct at the flame from the front or side. 8,5 8 5 6 7 8 M0 cable gland Housing Spring force terminals Sensor head 5 Positioning aid 6 Sticker 7 UV tube 8 Bracket Positioning aid to allow simple alignment when replacing sensors/ tubes. 5 Installation CAUTION Use UV sensor only in conjunction with Elster Kromschröder automatic burner control units, flame detectors or burner control units in order to avoid damage. It is preferable to install the unit inclined from above or in the horizontal. < 00mm (6 ) Distance between UVS and flame: max. 00 mm (6"). -

Replacement Wiring Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power supply. Replacing the old UVS 5 with the new UVS 5G The old UVS 5 (with non-detachable PVC cable) can be replaced with the new UVS 5G (with cable gland and spring force terminals). A UVS 5 B UVS 5G Bracket A and clamping collar B from the old UVS 5 can be used to secure the new UVS 5G. Disconnect the system from the electrical power supply. Shut off the gas supply. Old UVS 5 Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power supply. Connection cable: Use in accordance with local regulations. Lay individually and, if possible, not in a metal conduit. Do not lay together with ignition cable but lay them as far apart as possible. M0 cable gland is designed for cable diameters of 7 to mm. Spring force terminals for wire cross-sections > 0. mm² to.5 mm² (AWG to AWG 6). Max. cable length in accordance with the specifications for automatic burner control units IFS, IFD, PFS, PFD, flame detectors IFW, PFF or burner control units BCU, PFU. External electrical interference must be avoided. Disconnect the system from the electrical power supply. Shut off the gas supply. 5 Clamping collar 6 Attach the clamping collar from the old UVS 5 to the new UVS 5G. 7 Fit the new UVS 5G with the clamping collar in the bracket of the old UVS 5. 8 Direct UVS 5G at the flame from the front or side. 9 Tighten the bolt of the clamping collar to secure the UV sensor in the required position. Electrical connection of the new UVS 5G, see page (Wiring). µa + UVS PE Wiring, see IFS, IFD, PFS, PFD, IFW, PFF, BCU or PFU connection diagram. Flexible wires without wire end ferrules can also be connected to the spring force terminals. To insert a flexible wire, the terminal must be opened using the push-button. -

Maintenance Replacing the UV tube Assistance in the event of malfunction Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power supply. CAUTION Do not touch the replacement UV tube with bare fingers. The sensor tube must be replaced after approx. 0,000 operating hours (approx. year). Spare parts (tube, sticker, seal), see www.partdetective.de Disconnect the system from the electrical power supply. Shut off the gas supply. 6 5 Use new sticker. Insert tube with seal. Electric shocks can be fatal! Before working on possible live components, ensure the unit is disconnected from the power supply. Fault-clearance must only be undertaken by authorized trained personnel! Do not carry out repairs on the UV sensor on your own as this will cancel our guarantee. Unauthorized repairs or incorrect electrical connections can cause the UV sensor to become defective. In this case, fail-safe operation can no longer be guaranteed. (Remote) resets may only be conducted by authorized trained personnel with continuous monitoring of the burner to be repaired. Safe operation only in conjunction with Elster Kromschröder automatic burner control units, flame detectors or burner control units. Measure the current in the flame signal cable (connect the positive pole of the measuring instrument to the cable from the automatic burner control unit and the negative pole to the cable from the UV sensor). UVS + µa PE The measured direct current must be greater than µa (typically 0 µa).? Fault! Cause Remedy? A direct current is flowing, but no flame present.! The UV sensor is influenced by the flames of other burners, e.g. by reflection on the furnace walls. Position the sensor so that it can only view its own dedicated flame (e.g. use viewing tube).! Humidity inside the sensor. Vent sensor.! The service life of the UV tube has expired. Replace UV tube in the UV sensor, see page (Maintenance).! The sensitivity of the flame amplifier in the automatic burner control unit is too high. Adjust the switch-off threshold on the automatic burner control unit. -

? No direct current although the flame is burning.! The UV sensor is dirty, e.g. sooted. Clean sensor.! Humidity inside the UV sensor. Vent sensor.! The distance between the UV sensor and the flame is too great. Reduce the distance.? The automatic burner control unit ignites in pulses.! The sensor sees the ignition spark. Reposition the UV sensor so that it cannot see the ignition spark. Use an automatic burner control unit that is able to distinguish between an ignition spark and a flame signal.? The intensity of the flame signal decreases after a longer period of operation.! UV tube fault due to incorrect UV sensor connections. Connect the UV sensor in accordance with the wiring instructions. Remove the UV sensor and return for repair.? The automatic burner control unit performs a fault lock-out during start-up or operation.! The highly fluctuating flame signal temporarily exceeds the switch-off threshold. Reduce the distance between UV sensor and flame. Position the UV sensor so that it can view the flame without hindrance (e.g. smoke curtain).! The switch-off threshold in the automatic burner control unit is set too high. Adjust switch-off threshold. Technical data Plastic housing with connection terminals. Wire cross-section for connection terminals:.5 mm ( AWG 6). Cable gland for cable diameters of 7 to mm. Distance between UV sensor and flame: max. 00 mm (max. 6"). UV tube: P578, spectral range: 90 70 nm, max. sensitivity: 0 nm ± 0 nm. Service life of the UV tube: approx. 0,000 operating hours. Min. DC signal: μa. Enclosure: IP5 IP0 IP5 (Nema ) in wiring chamber, IP0 around the viewing openings with fitted tube. Ambient temperature/storage temperature: -0 to +80 C (-0 to +76 F). Weight: 80 g (0.6 lbs). Max. length of cable UV sensor automatic burner control unit: see operating instructions for automatic burner control unit. Logistics Transport Protect the unit from external forces (blows, shocks, vibration). On receipt of the product, check that the delivery is complete, see page (Part designations). Report any transport damage immediately. Storage Store the product in a dry and clean place. Storage temperature: see page 5 (Technical data). Storage time: 6 months before using for the first time. Packaging The packaging material is to be disposed of in accordance with local regulations. Disposal Components are to be disposed of separately in accordance with local regulations. -5

Certification Eurasian Customs Union The product UVS 5 meets the technical specifications of the Eurasian Customs Union. Contact If you have any technical questions, please contact your local branch office/agent. The addresses are available on the Internet or from Elster GmbH. We reserve the right to make technical modifications in the interests of progress. -6 Elster GmbH Postfach 8 09, D-908 Osnabrück Strotheweg, D-950 Lotte (Büren) T +9 5-0 F +9 5-70 info@kromschroeder.com, www.kromschroeder.com