VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

Similar documents
Operations & Service Manual

Ventless Operation Supplement GBF-D-VH

Operations & Service Manual

Operations & Service Manual

OPERATION, SERVICE & PARTS MANUAL

MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL

Outdoor/Commercial Refrigerator USER S MANUAL

Professional Warming Drawer and Warming Drawer Cabinet

Outdoor Refrigerator USER S MANUAL

OPERATION, SERVICE & PARTS MANUAL

Instruction Manual. Double Candy Apple Cooker

20 INCH ELECTRIC GRIDDLE

INSTALLATION & OPERATING INSTRUCTIONS

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Instruction Manual. Cheese Warmer with Pump

Hot Dog Roller Grills

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

ELECTRIC FIREPLACE OWNER S MANUAL

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions


Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Part No Revised November / Instruction Manual Model #8150 AND #8151

Owner s Manual. Electric Fireplace Wall Mounts Only. Copyright ShopRangeHoods.com 2016 Office: +1 (626)

Register your product within 30 days of purchase to activate its one-year

Installation, Operation, Maintenance, & Troubleshooting Model: CLS36-440V Electric Cruise Line Salamander Serial:

user manual Model #: BLZ-WVH-42

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

DUST FREE CARBON Whole House Air Purifier

INSTALLATION & OPERATION MANUAL BROASTER 15RBW SNACK-MATE RADIANT BROILER

Operator s Manual. Histology Bath

SAVE THESE INSTRUCTIONS

User Manual / Installation Instructions

USE AND CARE GUIDE COMBINATION KITCHENS. C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series

Instruction Leaflet. Read instructions before operating. Retain for future reference.

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

INSTRUCTION MANUAL. Full Size Gas Convection Oven

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

SAVE THESE INSTRUCTIONS

Operations and Service Manual

P.N ELECTRIC KETTLE User Manual Series MODEL BVSTKT308

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Operation Maintenance. Mobile Oil Caddy

MH70230AS MH70236AS MH70248AS

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL

user manual Model #: BLZ-HOOD

42 in. Oscillating Tower Fan w/ Remote Control

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

Operation Manual SA Vent. Models Kona, Pali and Mistral

14 Upright Vacuum with HEPA Filter & Dual Power

ELECTRIC KETTLE Model BVSBKT1703 Series. User Manual. QUESTIONS? COMMENTS? IN CANADA: P.N Rev.A

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

INTELLICRISP WAFFLE MAKER INSTRUCTION MANUAL MODEL: CKCLWF1. Calphalon_WaffleMaker_IB_SPEC_DarkGrey_CKCLWF1_19EM1.indd 1 1/25/19 09:30

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Ui REFRIGERATOR SPEC SHEET

CINCINNATI, OH USA

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

Instruction Manual. Bucket Oil Pump

Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial:

MODEL NO: WD Warming Drawer, Rated 120V, 60 Hz,450W, 4A. Certificate Project Figure No. Version A

P.N User Manual STAINLESS STEEL ELECTRIC KETTLE 5964/5965 Series MODELS

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

2 Finding Information

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Installation, Operation & Service Manual

Installation & Maintenance Instructions

Instruction Manual. Fun Pop 4oz Popper

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

VersaBrew SINGLE SERVE COFFEE MAKER USER GUIDE

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

WARNING: FOR OUTDOOR USE ONLY

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

Vertical Electric Smoker 505

Professional Built-In Hoods

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Instruction Manual. Carmel Apple-Dip Warmer

42 Oscillating Tower Fan with Remote Control. OWNER S MANUAL Model # FC1-42R-03

IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS

Instruction Manual for the Globe Mixer. Model SP8-RL

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

Operator s Manual. IP-100 Immersion Probe Cooler

SAVE THESE INSTRUCTIONS

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

Ventless Hoods For Rotisseries. SERIES: VGH Operation Manual

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

ULTRASONIC humidifier

Transcription:

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016 HOODMART 172 REASER COURT ELYRIA, OH 44035 PHONE: (800)-715-1014 FAX: (800)-716-1214 1

THIS PAGE LEFT BLANK INTERNTIONALLY 2

LIMITED WARRANTY Subject to the terms and conditions of this Limited Warranty as herein stated, all Hoodmart equipment and parts purchased new from an authorized Hoodmart representative are warranted as to defects in material or workmanship for a period of 12 months from the date of installation, provided, however, that with regard to labor costs in connection with this warranty, see below. All installations must be made by a qualified installing agency in accordance with all applicable codes and/or regulations in the jurisdiction in which the unit is installed. Limited warranty coverage is extended to the original owner only and is void if the unit is resold. During the Limited Warranty period, Hoodmart will replace or recondition, at its factory, any part or parts of this unit which Hoodmart inspectors judge defective. Provided the unit has been subjected to normal use, has been properly installed, operated and serviced. The Limited Warranty does not cover cosmetic damage, and damage due to acts of God, accident, alteration, and negligence, abuse of the Hoodmart equipment or the use of unconventional repair methods. All parts replaced under this Limited Warranty carry only the remainder of the term of this Limited Warranty. Only an authorized Hoodmart representative may furnish limited Warranty service. Hoodmart reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured. Repair or replacement as provided under this Limited Warranty is the exclusive solution. Hoodmart shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, except to the extent prohibited by applicable law. Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this Limited Warranty. Used Hoodmart equipment or parts not purchased from an authorized Hoodmart representative do not carry warranties, express or implied. 3

SPECIFIC SAFETY PRECAUTIONS For your safety, please observe the following safety precautions when operating or servicing your Hoodmart equipment. Read the following important safety information to avoid personal injury and/or damage to the equipment. CAUTION/WARNING! Consult a qualified electrician to ensure all of the following guidelines: All electrical specifications and codes are met. Circuit breakers and wiring are of sufficient rating and gauge. The unit must be properly grounded and all electrical specifications must be met during installation. Improper installation, adjustment, alteration, service or maintenance could result in death or serious injury, equipment/property damage, and will void the warranty. DO NOT use or store gasoline, other flammable liquids or vapors in the vicinity of this or any other appliance. Failure to comply with these DANGER notices may result in death or serious injury, equipment/property damage, and will void the warranty. WARNING DO NOT operate the unit unless you understand the components and the intended use. The unit must remain in the upright position. Exercise care when removing the wooden crate from around the unit. Failure to comply with WARNING notices could result in death or serious injury and equipment/property damage and will void the warranty. CAUTION The unit must be adequately and properly grounded. Improper grounding may result in electrical shock. Consult an electrician to ensure all electrical specifications have been met and the unit is properly grounded. The wiring diagrams contained in this manual should aid your electrician in the installation of your unit. Ensure the unit is positioned in a secure, safe location. The electronic components of the Control Panel are impact-sensitive. Exercise care around the Control Panel to maintain proper operation. DO NOT install the unit next to combustible walls and materials. Failure to maintain safe distances may result in fire. Turn off the unit and unplug the power cord before cleaning or performing maintenance. 4

DO NOT hose down the unit s interior, or exterior with water. During cleaning of the unit: DO NOT steam clean. DO NOT use products containing chlorine. DO NOT use abrasive products, steel wool or scouring pads. DO NOT modify, alter or add attachments to this equipment! Failure to comply with these CAUTION notices may result in equipment/property damage and void the warranty. NOTE: If the crate is damaged upon receipt, immediately inspect the unit and notify the carrier of any damage to the unit. To aid the electrician, an electrical wiring diagram is contained in this manual. Refer to the wiring diagram during installation or servicing. Comply with all appropriate state and/or local heath regulations regarding the cleaning and sanitation of equipment. 5

DIMENSIONS MODEL AVH23 REGULATORY LISTINGS (CERTIFICATIONS): The Ventless System shall be built in accordance to NFPA96; UL listed, and comply with UL710B Standards. Hoods shall be tested to comply with NSF Sanitation Mark. Unit Weight: 565 lbs. UNPACKING: Your unit may arrive enclosed by a wooden crate. The Hood is secured to a wooden platform by means of high-tensile strength strapping. NOTE: If the crate is damaged, immediately inspect the unit and notify the carrier of any damage to the unit. Exercise care when lifting or moving the unit. Exercise care when removing the wooden crate from around the unit. LOCATE AND IDENTIFY THE FOLLOWING COMPONENTS AFTER UNPACKING: Hood and Fire Suppression System Floor Stand and Contactor Box ANSULEX Fire Suppressant, 1.5 Gallon Drip Cup Grease (baffle) Filter, Air (Mesh) Filter, Charcoal Filter 6

DIMENSIONS MODEL AVH36 REGULATORY LISTINGS (CERTIFICATIONS): The Ventless System shall be built in accordance to NFPA96; UL listed, and comply with UL710B Standards. Hoods shall be tested to comply with NSF Sanitation Mark. Unit Weight: 735 lbs. UNPACKING: Your unit may arrive enclosed by a wooden crate. The Hood is secured to a wooden platform by means of high-tensile strength strapping. NOTE: If the crate is damaged, immediately inspect the unit and notify the carrier of any damage to the unit. Exercise care when lifting or moving the unit. Exercise care when removing the wooden crate from around the unit. LOCATE AND IDENTIFY THE FOLLOWING COMPONENTS AFTER UNPACKING: Hood and Fire Suppression System Floor Stand and Contactor Box ANSULEX Fire Suppressant, 3.0 Gallon Drip Cup Grease (baffle) Filter, Air (Mesh) Filter, Charcoal Filter 7

DIMENSIONS MODEL AVH48 REGULATORY LISTINGS (CERTIFICATIONS): The Ventless System shall be built in accordance to NFPA96; UL listed, and comply with UL710B Standards. Hoods shall be tested to comply with NSF Sanitation Mark. Unit Weight: 985 lbs. UNPACKING: Your unit may arrive enclosed by a wooden crate. The Hood is secured to a wooden platform by means of high-tensile strength strapping. NOTE: If the crate is damaged, immediately inspect the unit and notify the carrier of any damage to the unit. Exercise care when lifting or moving the unit. Exercise care when removing the wooden crate from around the unit. LOCATE AND IDENTIFY THE FOLLOWING COMPONENTS AFTER UNPACKING: Hood and Fire Suppression System Floor Stand and Contactor Box ANSULEX Fire Suppressant, 3.0 Gallon Drip Cup Grease (baffle) Filter, Air (Mesh) Filter, Charcoal Filter 2

ELECTRICAL REQUIREMENTS Consult a qualified electrician to ensure all electrical specifications have been met and that the unit is properly grounded. The unit must be adequately and properly grounded. Improper grounding may result in electrical shock. Always refer to your local electrical code to ensure proper grounding of this or any other electrical equipment. Always consult with an electrician or other qualified service person to ensure breakers and wiring are of sufficient rating and gauge for the equipment being operated. Improper installation, adjustment, alteration, service or maintenance could result in death or serious injury, equipment/property damage, and void the warranty. Model # Voltage Hz Phase Amps HMVH23 208-240 60 1-3 75 NOTE: 3 AMPS FOR HOOD Model # Voltage Hz Phase Amps HMVH36 208-240 60 1-3 75 NOTE: 4.5 AMPS FOR HOOD Model # Voltage Hz Phase Amps HMVH48 208-240 60 1-3 75 NOTE: 6 AMPS FOR HOOD CONNECT HOOD POWER: Apply AC power to the Contactor box. The power requirement of the fryer will determine the input. Remove plug (if present) from the AC power cord of the fryer; connect the fryer power cord to the contactor output All connections should be made by a qualified electrician to ensure all electrical specifications have been met and comply with all local codes. HOOD AND APPLIANCE INTERLOCK CONNECTION This connection will cause the appliance below the hood to shut down if any of the following occurs: Filter (any) becomes excessively dirty and does not allow proper airflow through the hood. Filter (any) is missing or not installed properly. Fire Extinguisher System is activated. 3

WIRING DIAGRAM 4

THIS PAGE LEFT BLANK INTERNTIONALLY 5

WIRING DIAGRAM CONT. 6

FIRE SUPPRESSION SYSTEM The fire suppression system used in your Ventless Hood System is an Ansul R-102 Restaurant Fire Suppression System (Standard UL 197 Listed). An authorized Ansul distributor in accordance with the system s listing must perform final installation, charging and testing of the system. The fire suppression system is designed and UL-listed to provide fire protection for cooking appliances such as fryers. It protects your units, automatically, 24 hours per day. The integrated ANSUL system contains piping, nozzles. All nozzles have been factory installed in the proper operating position. DO NOT MOVE OR ADJUST. This Hood also requires use of a Manual Pull System. The Manual Pull System is already integrated into your system. 7

MAINTENANCE Maintenance is necessary for your Ventless Hood System to maintain the unit s efficiency over time. Quarterly Hood Cleaning During cleaning of the unit: DO NOT steam clean. DO NOT use products containing chlorine. DO NOT use abrasive products, steel wool or scouring pads. Interior: Disconnect power from the unit! Remove all filters from the hood. Using a mild degreaser with a soft towel or sponge, clean the entire Hood Plenum and Blower Sections. The hood must be cleaned every 3 months. Exterior: Remove power from the unit. Clean all external stainless steel parts using a stainless steel cleaner. Filters: Baffle filter: The Baffle Filter should be cleaned daily. Place the Baffle Filter in a sink and clean with a mild degreaser. Dry thoroughly, then reinstall in the unit. Mesh Filter: Should be cleaned daily. Place the filter in a sink and clean with a mild degreaser. Dry thoroughly, then reinstall in the unit. Charcoal Filter: Never attempt to clean the Charcoal Filter. Replace every 90 days. The reuse of a Charcoal Filter can cause damage to the unit. 8

SEMI-ANNUAL FIRE SUPPRESSION SYSTEM SERVICING: Service of the Fire Suppression System is to be conducted by qualified fire equipment personnel ONLY! Semi-annual (at minimum) inspections should be scheduled and accomplished for the Fire Suppression System. Such service shall consist of the following: Place fire extinguishing system-locking bar on fire system when servicing hood. 1. Remove charging cartridge, inspect gasket for cuts and elasticity, coat gasket with extreme temperature grease and reinstall. 2. Remove tank, verify chemical is at proper level, clean and coat O-ring with extreme temperature grease and reinstall. 3. Check all nozzles to insure they are free of cooking grease buildup. 4. Test the remote manual pull station for activation and wear. 5. Install test link and cut to simulate automatic actuation. 6. Clean and inspect fusible links. 7. Inspect wire rope for wear at pulleys and detectors and replace if necessary. 8. Record maintenance date and maintain in a permanent file. ANNUAL FIRE SUPPRESSION SYSTEM SERVICING: Same as Semi-Annual but all fusible links must be replaced with new fusible links. MAINTENANCE SCHEDULE MAINTENANCE LOG Procedure: Daily Quarterly Semi- Annually Annually Clean baffle filter Clean wire mesh Filter. Replace Charcoal filter. Interior hood cleaning. Exterior hood cleaning. Fire suppression system servicing. 9