User s Guide REO-MECH. Industrial Rebar Benders & Cutters

Similar documents
User s Guide REO-MECH. RB-16 Electric Rebar Bender

Pocket Hardmount. Preventative Maintenance.

Safety Warnings. Work area safety. Electrical Safety. Personal Safety

ENGLISH (Original instructions) INSTRUCTION MANUAL. Demolition Hammer HM0810TA DOUBLE INSULATION. IMPORTANT: Read Before Using.

hp Dust Collector With Vacuum Attachment

Tornado Operations & Maintenance Manual

INSTRUCTION MANUAL W-400

ENGLISH (Original instructions) INSTRUCTION MANUAL. Power Mixer UT2204 DOUBLE INSULATION. IMPORTANT: Read Before Using.

MANUAL SWEEPER GUIDE. Model 920. Please make sure you read the instruction manual below and clear the operation before you use this sweeper.

Page 1 of 18. Part# /5/2013

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

Desoldering Tool. Instruction Manual

Electric Hover Mower. Owner s Manual. Important

GUH90 90 cm Canopy Hood

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

Installation & Operating Guide

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions

GUH52SD 52 cm GUH75 75 cm Canopy Hood

Instructions for Use. Electric Pole Hedge Trimmer Input Power Tooth gap of cutter blade 16mm

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

GALAXY FLOOR MACHINE

Wagner Product Training

MTC-Series Manual Trash Compactors Instruction Manual

INSTRUCTION MANUAL MODEL: 690E

Grinding mill MISTRAL 50L (art. 650P)

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

BLAST-IT-ALL BUMPER BLASTER

SAFETY AND OPERATING MANUAL. 450W/46cm HEDGE TRIMMER JM450PHT

RSH2455G OPERATOR S MANUAL ELECTRIC QUIET CHIPPER SHREDDER

SuperKlean Washdown Products

POWER CUT Hedge Trimmer 46 Model No. 101HT450

4-GALLON MOBILE PARTS WASHER

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

HEDGE TRIMMER. 550W 450mm WARRANTY INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au HTE-550 WHAT S IN THE BOX

7165 Dust Collector Owner s Manual

SuperKlean Washdown Products

SSS Speedster 600 (Model SP-600, #56001) SSS Speedster 1000 OPERATION SERVICE PARTS CARE. SSS Speedster 1000 SSS Speedster 600

model No: ir20.v2 FUSE

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

Frontload Washer. Preventative Maintenance.

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Audi-Larm Audible Alarm

5.0 cu ft Electric Concrete Mixer

OWNERS MANUAL. To Order Parts Call SPEED AIR MOVER

100T Electric Shop Press

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

ATD /8 Electric Drill

Qualcast 430W Grass Trimmer (Model: GT2826)

DEUTSCH Bio-Master Bio-Max

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

Wet/Dry Vacuums Polyethylene, Polypropylene, & Steel

DELUXE ELECTRIC POWER BRUSH

Centrifuge STANDARD OPERATING PROCEDURE

690 Power Fishing System

1 supply. Belt Sander INSTRUCTION MANUAL. y::;:,' mm (3") MODEL 9900B. Specifications. DOUBLE INS ULATlO N. Continuous. Belt speed 1.

FAILURE TO ADHERE TO THESE WARNINGS CAN RESULT IN FIRE, SERIOUS INJURY, ELECTRICAL SHOCK AND/OR DEATH. Technical Service

MEMOIRS VITREOUS CHINA TOILETS

ORIGINAL INSTRUCTIONS. 18V ONE + Cordless Pole Pruner. RPP1820Li15 OPP1820

AllClear G2 Series Pressurized Filters Product Manual

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

ELECTRIC HEDGE TRIMMER

LARGE AREA VACUUM LAV-30

Tornado Operations & Maintenance Manual

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

Series 1140 and 1141 Temperature Regulators

ELECTRIC BODY SAW INSTRUCTIONS. Item #31660

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

Blower UB1100 UB1101 INSTRUCTION MANUAL

Manual / Handbuch Spare parts list / Ersatzteilliste

GRIND PRO DUAL OR DISC SANDER. Operator Manual

474A+ TIP CARE AND USE INSTRUCTION MANUAL DESOLDERING STATION

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

150T Electric Shop Press

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

DELUXE ELECTRIC POWER BRUSH

Operation and Maintenance Manual 120V/60HZ


FEB 15 Rev C

BT16.4SS-HK BT19.4SS-HK Cooker Hood

CLUB SERIES ADJUSTABLE AB BENCH

Pump Out Vacuums Polyethylene & Steel

PRO 2000i LOW LEVEL DEPOSITOR

Qualcast W Electric Hover Mower (Model: MEH1733R)

ORIGINAL INSTRUCTIONS Cordless Hedge Trimmer RBC36X26E RHT3626DR RBC36X26E RHT3600R

Model No: Little Devil II (inc ss)

Direct Heat Foot Sealers Models: W-220DT(S), W-300DT(S), W-450DT(S) Distributed By:

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

HEDGE TRIMMER. 600W 550mm INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au HTER-600 WHAT S IN THE BOX. Hedge Trimmer. Blade Cover.

CORDLESS HAND VACUUM INSTRUCTION MANUAL

Transcription:

User s Guide REO-MECH Industrial Rebar Benders & Cutters

WARNING: PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THIS MACHINE Machine is not rated and should not be used for commercial rebar production purposes. Do not operate bender and cutter at the same time. Rebar Bender Models 1. Safety This machine is a high performance, industrial machine. Failure to follow safety instructions may result in serious injury or death. 1. Take note of all warning signs on machine. 2. Keep work area clean and free from obstruction. 3. Ensure power supply is properly earthed. 4. Keep body parts well clear of moving parts and protected areas when machine is switched on. 5. Authorized personal protective equipment must be worn when operating machine (minimum requirement - safety glasses (when operating cutter), protective gloves and class 2 hearing protection). 6. Indoor use only - never operate machine in wet or damp conditions. 7. Stand well clear of machine when in use (opposite the direction of bend). 8. Use away from others, particularly children. 9. Ensure power & pedal switch cords are securely fastened prior to switching on machine. 10. Use emergency stop button immediately if issues arise during operation. 11. Ensure lifting chains are fastened securely below lifting arms and through ring bolt when in transit. 12. Never attempt to bend rebar outside of models prescribed diameter range (refer to table in Specifications & Parts section). 13. Do not bend short lengths. 14. Mount machine on even surface capable of carrying weight of machine. Machine should not vibrate on surface during operation. 15. Clean machine of loose debris after use. 16. Never attempt to service machine (other than general maintenance procedures outlined in Maintenance section). Contact supplier if issue arises. 17. Only use REO-MECH approved spare parts and accessories with machine. 18. Keep away from sparks and naked flames. 19. Always check power cords for damage and safe placement prior to use. 20. Disconnect machine from power outlet when not in use. 21. Inspect machine before each use. Do not use when quality has been compromised. 22. Do not cover air vents on machine. 23. Store out of reach of children.

2. Transporting Machine 1. Install & tighten ring bolt securely. 2. Check lifting arm bolts to ensure bolts are securely fastened. 3. Secure lifting chain below lifting arms and through ring bolt to prevent excess movement during transport. 4. Ensure all machinery & equipment used to transport the machine are rated for required loads. Ring Bolt Lifting Arm (each corner) 3. Specifications & Parts Power Supply: Ensure machine is connected to correct power supply (check machine label to confirm power supply). Extension Leads: Where possible, connect machine directly to power outlet. If an extension lead is required, ensure lead is under 50m in length. Minimum extension lead diameter are prescribed below: Extension Lead Length (m) Min Wire ø (mm²) 30m 2.5 50m 4.0

Machine Specifications Models CRB-25 CRBC-25 CRB-32 CRBC-32 Input Voltage - Single Phase 220-240V AC ~50Hz or 110-120V AC ~60Hz * Power Consumption 220-240V Power Consumption 110-120V Bender 1050W 1050W 1800W 1800W Cutter - 1550W - 2400W Bender 1150W 1150W 1900W 1900W Cutter - 1500W - 2150W Net Weight 91kg 136kg 175kg 225kg Dimensions (cm) 45L x 50W x 44H 50L x 45W x 79H 60L x 58W x 47H 60L x 58W x 98H Bending Range 6-25mm** 6-25mm** 6-32mm** 6-32mm** Cutting Range - 4-25mm** - 6-32mm** * Check machine label to determine correct power supply. ** Refer to machine model data sheet for maximum tensile strength/grade. Machine Parts Adjustment Block Fixed Bending Pin Gyre Bending Pin Power Indicator Light Point 1 Angle Control Dial Point 2 Angle Control Dial Emergency Stop Button Start Switch Pedal Switch Pedal Switch Point 2 Input Pedal Switch Point 1 Input Note: Location of features on machine face may vary with machine model.

4. Operating Machine General notes: Machine is equipped with an emergency stop button. Ensure pedal switch cords are securely fastened to inputs (if pedal switch required). Always ensure point 1 angle is set at least 5 degrees higher than point 2 angle. Ensure angle control dials are securely fastened. Wait until bending cycle is completed before starting new cycle. If pedal switches are not required, press the start switch to bend to point 1 angle. Pre-use Checks 1. Check power supply is properly earthed. 2. Check that power cord is undamaged and plug is not loose (also applies for extension leads). Bending Procedure 1. Secure required fixed bending pin and gyre bending pin combination as per table below. 2. Modify adjustment block to suit required bar size. 3. Securely fasten pedal switch cords to machine inputs (if required). 4. Connect to power source and observe power indicator light on machine face indicating machine is ready for use. 5. Adjust point 1 and point 2 angle control dials to required angles ensuring point 1 angle is set at least 5 degrees higher than point 2 angle. Securely fasten angle control dial once required angles are set. 6. Stand well clear of machine (opposite direction of bend). 7. Press the pedal switch connected to pedal switch point 1 input to bend to point 1 angle. Note: Pressing the start switch will also bend to point 1 angle. 8. Press the pedal switch connected to pedal switch point 2 input to bend to point 2 angle. 9. Bender/cutter model also has pedal switch point 3 input to operate cutter (see Additional Instructions for Rebar Cutter section). CRB-25/CRBC-25 CRB-32/CRBC-32 Fixed Bending Pin Gyre Bending Pin Fixed Bending Pin Gyre Bending Pin ø80 ø105 ø115 ø85 ø80 ø120 ø140 ø165 ø110 ø75 5. Working Conditions Do not use or store machine outside of environmental conditions below: Working Temperature Humidity Storage Temperature Elevation Environment -10 C - +45 C <90% RH -20 C - +65 C < 100m Interior, waterproof, non-corrosive, non-flammable

6. Maintenance Always ensure power is disconnected before performing maintenance. Cleaning: Always wear gloves to protect hands from metal splinters when cleaning. Wipe or brush away all dust and metal filings (can use compressed air). Carbon Brushes: Inspect carbon brushes monthly. Worn brushes will result in power loss and cause irreparable damage to the armature s commutator. Check brushes immediately if a loss of power or electrical fault is experienced. Replacing Carbon Brushes: 1. Open the access side panel and locate the motor housing(s) with black lid. 2. Locate the brush caps on both sides near the top of the motor housing(s). 3. Open the brush caps with a screwdriver and remove carbon brushes from the machine. 4. Inspect the carbon brushes and replace where worn or damaged. 5. Reinstall new carbon brushes and brush caps securely. 6. Replace access side panel. Brush Caps Motor Housing Lubrication: Lubricant shall be checked every 2 months for heavy usage or when loss of power is experienced. Always use approved lubricant with high corrosion and friction resistance properties. Apply lubricant via grease gun to lubricant hole to ensure lubricant chamber remains full. Lubricant Hole

Additional Instructions for Rebar Cutter (Rebar Bender/Cutter Model) 1. Safety 1. Keep body parts well clear of cutting blocks when machine is switched on. 2. Never attempt to cut rebar outside of models prescribed diameter range (refer to table in Specifications & Parts section). 3. Do not cut short lengths. 4. Inspect cutter before each use (refer to Maintenance section). Do not use when quality has been compromised. 5. Beware of ejected objects during the cutting process. Always wear approved safety glasses. 6. Use protective gloves when cleaning machine or handling cutter blocks as edges are very sharp. 7. Do not touch pump housing after use as it will be hot. Wait for machine to cool. 8. Where available, safety guard should be installed. 2. Cutter Parts Note: Safety guard installation - use bolts supplied with safety guard to securely replace existing cutter block bolts, ensuring safety guard covers bar ejection zone. Cutter Rod Oil Plug Cutter Blocks Safety Guard Brush Caps U-Shaped Support Stopper Cutter Block Bolts Pump Housing Motor Housing Note: Cutter body varies with different models - use as a general guide.

3. Operating Machine Pre-use Checks: Check condition of cutter blocks and tightness of cutter block bolts (refer to Maintenance section). Warm Up: In cold weather, warm up cutter by repeating cut cycle for 60 seconds to ensure hydraulic oil reaches proper viscosity. Stopper Adjustment: Adjustable stopper must be set in correct position dependent on size of rebar. 1. Insert rebar into U-shaped support. 2. Keeping rebar at 90⁰ to machine, screw in stopper until it is just touching the rebar. Cutting Procedure: 1. Securely fasten pedal switch chord to pedal switch point 3 input. 2. Connect to power source and observe power indicator light on machine face indicating machine is ready for use. 3. Insert rebar between stopper and front cutter block, making sure it is properly seated in U-shaped support. 4. Press the pedal switch connected to pedal switch point 3 input while cutter rod advances and fully cuts rebar. 5. Release pedal switch only once rebar has been fully cut to allow cutter rod to retract. Note: Power will be compromised if hydraulic oil exceeds 70 C. Allow machine to cool before resuming operation. 4. Maintenance Always ensure power is disconnected before performing maintenance. To access Rebar Cutter: 1. Open the access side panel and locate the rebar cutter with a black cover. 2. Remove the screws to lift cover and access rebar cutter. Cutter Blocks: Check cutter blocks for damage before each use. If cutter block is damaged, replace block before next use as per following diagram: Fix longer cutter block bolt pair here Ensure cutter block with rounded edges installed here. Ensure cutter block with flat edges installed here. Fix shorter cutter block bolt pair here Check cutter block bolts for tightness before each use. Use protective gloves when handling cutter blocks as edges are very sharp.

Cleaning: Clean machine after each use. Use protective gloves when cleaning to protect hands from metal splinters. Do not use air gun as this may cause dust and metal filings to enter vents. 1. Extend cutter rod and disconnect from power source. 2. Wipe or brush away all dust and metal filings. Pay particular attention to lower half of cutter rod. 3. Connect to power source and press pedal switch to complete cut cycle. Oil Level Check: Check oil every 2 months or if loss of power apparent in rebar cutter. Hydraulic oil is highly flammable; keep away from sparks and naked flame. In case of ingestion or eye contact, consult a physician immediately. 1. Adjust stopper and make 3-4 cuts, noting exactly the point in which rebar is breaking. 2. Pinch next bit of rebar, stopping just before it breaks. Unplug machine from power source. 3. Turn unit over so oil plug is uppermost (if machine is hot allow to cool down first). 4. Remove oil plug and seal washer (never remove when machine is hot). 5. Check oil is level with bottom of plug hole. If oil is too low, top up with approved ISO VG46 oil. 6. Remove air bubbles - gently tilt cutter lengthways and return to level position. Top up and tilt cutter in opposite direction. Repeat this process until all air has been extracted. 7. Replace seal washer and oil plug. 8. Connect to power source and completely sever rebar. Oil Change: Change oil at least once a year or sooner if it appears dirty. 1. Unplug machine from power source. 2. Turn unit over so oil plug is uppermost (if machine is hot allow to cool down first). 3. Remove oil plug and seal washer (never remove when machine is hot). 4. Turn cutter over and drain oil into a suitable receptacle. When oil ceases to drain, tilt machine to rear to allow oil trapped in piston housing to drain out. When housing is empty, tilt unit in the opposite direction to empty the residue in the pump case. 5. Once all oil has been drained from the machine, turn unit over so oil plug is uppermost. 6. Slowly fill the machine with fresh oil and replace seal washer and oil plug. 7. Connect machine to power source and follow procedure for Oil Level Check. Note: Dispose of hydraulic oil in accordance with local regulations. Bolt Tightness: All bolts should be checked for tightness on a weekly basis or after every 500 cuts (whichever comes first). Carbon Brushes: Inspect carbon brushes on a monthly basis. Worn brushes will result in power loss and cause irreparable damage to the armature s commutator. Check brushes immediately if a loss of power or electrical fault is experienced. Replacing Carbon Brushes: 1. Unplug machine from power source. 2. Locate the brush caps on both sides near the back of the motor housing. 3. Open the brush caps with a screwdriver and remove carbon brushes from the machine. 4. Inspect the carbon brushes and replace where worn or damaged. 5. Reinstall new carbon brushes and brush caps securely.

RAPID TOOL AUSTRALIA Leading distributor of specialist construction tools & equipment www.rapidtool.com.au