Symphony Plus Combustion instruments

Similar documents
ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

COMPACT FLAME CONTROLLER CFC 2000

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

STEAMPAK Series BurnerPAK BMS Burner Management Systems

COMPACT FLAME CONTROLLER CFC 1000

Flame Monitors BROCHURE

EZ-FLAME Detector USER MANUAL

SUPREMATouch. Modular Fire & Gas Detection System

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

SUPREMATouch. Modular Fire & Gas Detection System

Safety Instrumented Fire & Gas Systems

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Flame 2350 (UV&IR) Flame Detection

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Products Catalog. Flame Monitoring & Evaluation Systems

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

For Complete Fire and Gas Solutions

FIREYE C9707A ALL FUEL SCANNER

W-FLAME IR/UV FLAME DETECTOR

Engineering Guideline. pac- Carriers Type Universal

Fire and Gas Monitoring Panel ST7-HV

Instrumentation Products and Applications

Products Catalog. Flame Monitoring & Evaluation Systems

The Next Generation Machine Protection System

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

COMPACT FLAME CONTROLLER CFC 100

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

Industrial Flame Monitoring. Engineered For The Toughest Environments

Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Dräger Polytron 8700 IR Detection of flammable gases and vapors

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Dräger Flame 2500 Flame Detection

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Gas Turbine Flame Monitoring

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger Flame 2100 Flame Detection

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Dräger Polytron 8000 Stationary gas detector (EC)

Speed and Frequency Seite 1 von 7

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

U2 Combination Viewing Head and Signal Processors

MBUV-100D, MBUVS-100D MBIR-100D, MBFR-100D DIN RAIL MOUNT FLAMEWORX MODULES

Chemical Processes in the Combustion

Industrial Flame Monitoring

Product Overview Combustion Technology

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 7000 Fixed gas detector

operational excellence Solutions for

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Dräger Polytron 8720 IR Detection of carbon dioxide

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

SUPREMATouch Modular Fire & Gas Detection System

TYPE 85UVF/IRF Integrated Flame Scanner with Internal Flame Relay

Power & Instrumentation BU

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Dräger REGARD 3900 Series Control System

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

YOUR PARTNER IN FIRE & GAS DETECTION

Flame Detection Jon Sarfas

Dräger Polytron 8310 Stationary gas detector (DSIR)

FM Approved Fire & Gas Detection System

Danfoss gas detection unit Type GD Heavy Duty

HART XL High Sensitivity Smoke Detection

Eclipse Trilogy Flame Safeguards

Dependable Solutions for Gas Detection

Danfoss gas detection units

Substation Monitoring System

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Dräger Polytron 8200 Stationary gas detector (CatEx)

The SharpEye 40/40I (IR3) Flame Detection

UDC100 Universal Digital Controller Specifications

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

SIL2-Interface/ -Signal Conditioners Series DuoTec

Compact HMI Overview

Product Overview Combustion Technology

Transcription:

Combustion instruments

Combustion instruments 1 [ 1 ] Flame Scanner integrated arrangement [ 2 ] Flame Scanner conventional arrangement Combustion instruments 2 Symphony Plus is the new generation of ABB s widely acclaimed Symphony family of distributed control systems the world s most used DCS in the power generation and water industries. In all, there are more than 6,700 Symphony DCS installations in operation all over the world, more than 4,700 of which are in power and water applications. No other automation platform has such a long fi eld record and large installed base as Symphony Plus. For several decades, ABB has been one of the world s leading providers of combustion monitoring and safety systems, delivering cost efficient and technologically advanced solutions designed to meet the needs of both retrofit and greenfield markets. With Symphony Plus, all this experience comes together in its combustion instrumentation to take ABB s offering to a new unmatched level of functionality and performance. The specific features built into the system s combustion instrument components are a direct reflection of ABB s diverse in-depth knowledge and experience in measurement accuracy and reliability. Symphony Plus infrastructure Combustion instrumentation is a key part of the Symphony Plus technology family, offering tight integration into all of the system s functional areas including: S+ Engineering, S+ Operations and S+ Control & I/O. These environments provide the necessary libraries, faceplates, symbols, function codes, interfaces and graphics necessary for the design, configuration and operation of the entire range of devices. There is no need for additional tools, interfaces or related training. In addition, the tightly integrated Symphony Plus infrastructure eliminates any need for local configuration or calibration of the individual modules. 2 Combustion instruments Symphony Plus

Flame scanner Uvisor TM SF810i The Uvisor SF810i flame scanner is available with accessories for the following installations: Line of sight (LOS) for wall fired burners Fiber optic cable (FOC) with outer guide pipe, cooling hose and fitting flanges for corner fired tilting burners Extended set-up, parameter files archiving, groups view, advanced diagnostic including raw flame data, real-time and historical trends of up to 254 scanner heads networked is possible through the PC based package Flame Explorer or the PROFIBUS Device Type Manager (DTM) Certified Unmatched overall capability and performance Symphony Plus flame scanners take advantage of the system s architecture, its unmatched scalability and simplicity, CPU power and communication speed. It is this high-performance infrastructure, in combination with the Uvisor SF810i flame scanner, which makes for the ideal flame failure protection system. The Uvisor SF810i is a multi-fuel scanner designed to provide stable and reliable information of both the presence of flame and its quality on utility and industrial boiler burners. In a single rugged housing, the Uvisor SF810i embeds state-of-art technology: Solid state sensor modules, covering the whole flame radiant spectrum (UV-VL-IR and dual sensor UVIR) Signal processor unit: an extremely powerful module capable to run the ABB proprietary flame analysis process. Live measurement of the dynamic flame parameters are constantly subjected to an extensive fail-to-safe validation routine, prior to vote the flame status Communication drivers: redundant PROFIBUS DP-V1 links (or alternatively redundant standard Modbus), are available to provide high speed data transfer to an external monitoring and supervisory system Termination and configuration board, with local display and push-buttons to allow the preliminary set up and on-line aiming assistance. The integrated scanner has screw type removable terminals as standard and are available with either IP66/67 or ATEX II 2GD EX d IIC T6 quick release connectors for ease of maintenance for non-hazardous and hazardous areas respectively Applications Utility and industrial boilers (wall fired, corner fired, supplementary fired WHRB, down-shot and cyclone burner types) Process heaters Sulphur recovery Gas turbine Off-shore boiler and furnace installation (Stainless steel housing (AISI 316L) Multi fuel Natural, coke oven, and sulphur gas Light and heavy fuel oil Orimulsion Pulverized coal Biomass Features Operation UV, VL, IR solid state sensors Dual sensor UVIR Continuous self-check Fast Flame Failure Response Time (F-FFRT) Digital Inputs for remote setting (isolated) Autotune Safety, Communication and Signalling Redundant Profibus DP-V1(isolated) Redundant Modbus (isolated) 4-20 ma (isolated) Fail-to-safe Flame Relay N.O. contact Fail-to-safe Fault Relay N.O. contact Real time flame flicker frequency display Real time flame intensity display Real time flame quality display Rejects mains frequencies and artificial lighting (EN298 compliant) Symphony Plus Flame scanner Uvisor TM SF810i 3

Flame scanner Uvisor TM SF810i Complete Safety Instrumented System (SIS) solution protects boiler and plant Symphony Plus TÜV certified safety system includes SIL 2 and SIL 3 rated field instruments including the SF810i flame scanner, controllers, I/O modules, valve positioners and actuators Delivered and supported in accordance with the strictest standards, including IEC 61508, EN-230, EN-298, NFPA 72 and NFPA 85 PROFIBUS communication interface Uvisor TM SF810i modules are fully integrated through a built in, convenient and fast PROFIBUS DP interface. The main features of this interface are: DP/V1 communication standard Up to 12 MBd communication rate Conforms to PROFIBUS PNO slave specification - System (master) redundancy - Flying (line) redundancy 2 independent PROFIBUS slave hardware interfaces in each module DTM and GSD files available The PROFIBUS interface is used to exchange parameters, commands and process variables with Symphony Plus controllers, eliminating the need for local adjustment of jumpers or switches. TÜV Rheinland SIL certification The fl ame failure trip functionality of the SF810i module is SIL 2 certified for functional safety and complies with EN-230 and EN-298 safety codes. Configuration Flame Explorer monitoring and configuration tool Proprietary PC based package, running on Windows OS Local push-button and digital display Firmware download utility Autotuning Flame Explorer When the SF810i is part of a Modbus network or if an individual SF810i is to be configured or interrogated, ABB provides the Engineering Tool Flame Explorer. This tool will configure and interrogate the unit. With it the trained operator with the correct password can set the flame drop out and pull in limits and the parameters used to optimize the flame discrimination between burners. In addition the Flame Explore evaluates and records trend of the important flame parameters including intensity, flicker frequency and flame quality. Monitoring of these parameters will enable the operator to spot deterioration in a burner before it becomes critical and to plan preventive maintenance. Environment ATEX II 2GD Ex d IIC T6 Gb Ex tb IIIC T 80 C Db IP66/67 ICEPI 06 ATEX 03C024 Installation Line of sight with sighting accessories Fibre optic cable through the windbox 1 SF810i FOC assembly 2 Flame Explorer trends 1 2 4 Flame scanner Uvisor TM SF810i Symphony Plus

Flame analysis unit Uvisor TM FAU810 A variety of limits can be configured in the Uvisor TM FAU810 to account for almost any situation that may occur in utility or industrial boilers. Flame detector interrogation The Uvisor TM FAU810 interrogates and analyses the flame signals generated by the Flame Detector. Calculates signal quality The Uvisor TM FAU810 measures the quality of the fl ame signal to provide an indication of changes in the burner flame. Flame quality values act as a barometer for forecasting when a burner flame-out is likely to occur. This can help the operator to anticipate changes and take action to mitigate problems before they can develop. Certified Continuous fault diagnosis The instrument automatically monitors the electronic components of the Flame Detector and Uvisor TM FAU810 unit to detect system problems or faults. If the diagnostics of Uvisor TM FAU810 detects a fault that could lead to an unsafe condition, the unit reliably indicates a flame-out condition to the boiler protection system to take the predetermined action on loss of flame. Uvisor TM Flame Analysis Unit The Uvisor Flame Analysis Unit 810 (FAU810) is ABB s leading-edge flame analysis device. The Uvisor TM FAU810 is designed from the ground up for maximum flexibility, usability and reliability. It takes advantage of the latest technologies available to make flame analysis optimize operation costs, while retaining ABB s rock-solid reputation as the most reliable instruments in the industry. The Uvisor TM FAU810 is easy to install and configure, flexible to operate, and uses redundant PROFIBUS DP-V1 or redundant standard Modbus interfaces for easy and reliable data exchange and tuning with Symphony Plus process controllers. One can connect almost any type of ABB Flame sensing device to the FAU810. This makes the Uvisor TM FAU810 the standard module for all ABB Flame Scanner application and an ideal solution for retrofitting an existing installation. The unit determines if the current flame signal value is within the programmed predefined limits. Flame Explorer When part of a Modbus network or if an individual FAU810 is to be configured or interrogated, ABB provides the Engineering Tool Flame Explorer. This tool is used configure and interrogate the Flame analysis unit. With it the trained operator with the correct password can set the flame drop out and pull in limits and the parameters used to optimize the flame discrimination between burners. In addition the Flame Explorer evaluates and records trend of the important flame parameters including intensity, flicker frequency and Flame quality. Monitoring of these parameters will enable the operator to spot deterioration in a burner before it becomes critical and to plan preventive maintenance. Symphony Plus Flame analysis unit Uvisor TM FAU810 5

Flame analysis unit Uvisor TM FAU810 Uvisor TM FAU810 specifications Each Flame Analysis Unit consists of two independent channels. Each channel can receive and process a flame detector signal. The two Detectors may be in any combination of the following device types: SF810 Flame scanner heads All DFS Flame scanner heads 4-20 ma sensor heads 0-5-volt sensor heads Ionization flame rod Each Detector is independently configurable from the Uvisor TM FAU810 pushbuttons and display, with Flame Explorer TM tool or via a PROFIBUS DTM. The Uvisor TM FAU810 can be powered by a single or redundant 24 VDC source. The Uvisor TM FAU810 has built-in diode auctioneering for power source isolation. Inputs and outputs Two digital inputs (optically isolated) available for fuel/load parameter switching Two SPDT contacts for main flame relay One SPDT contact for alarm or marginal flame relay Two 4-20mA isolated analog output Flexible installation configurations DIN rail mountable Standard 24 VDC power supplies (redundant) Reuse of existing cabinet installation for retrofits Remote mounting eliminates wiring for new installations PROFIBUS communication interface Uvisor TM FAU 810 modules are fully integrated through a built-in, convenient and fast PROFIBUS DP interface. The main features of this interface are: DP/V1 communication standard Up to 12 MBd communication rate Conforms to PROFIBUS PNO slave specification - System (master) redundancy - Flying (line) redundancy 2 independent PROFIBUS slave hardware interfaces in each module DTM and GSD files available The PROFIBUS interface is used to exchange parameters, commands and process variables with the main Symphony Plus controller eliminating the need for local adjustment of jumpers or switches. Standalone capability While these modules have been developed to integrate tightly within Symphony Plus, they have also been provided with the ability to operate in stand-alone mode, without the presence of a master controller. 3 Flame Explorer groups overview 3 6 Flame analysis unit Uvisor TM FAU810 Symphony Plus

Flame scanner Uvisor TM SF810 Unmatched overall capability and performance Symphony Plus Flame Scanners takes advantage of the system s architecture, its unmatched scalability and simplicity, CPU power and communication speed. It is this highperformance infrastructure, in combination with the Uvisor SF810 flame scanner, and the FAU810 module, that makes for the ideal flame failure protection system. Certified The Uvisor SF810 is a multi-fuel flame scanner designed to provide stable and reliable information of both flame presence or absence and the flame quality on utility and industrial boiler burners. In a single rugged housing, the Uvisor SF810 embeds the solid state sensor modules, covering the whole flame radiant spectrum (UV-to-IR including a dual sensor UVIR). The scanners have screw type removable terminals as standard and are available with either IP66/67 or ATEX II 2GD EX d IIC T6 quick release connectors for ease of maintenance for non-hazardous and hazardous areas respectively. The Uvisor SF810 flame scanner is available with accessories for the following installations: Line of sight (LOS) for wall fired burner boilers Fiber optic cable (FOC) with outer guide pipe, cooling hose and fitting flanges for corner fired tilting burners Applications Utility and industrial boilers (wall fired, corner fired, WHRB, down-shot and cyclone burner types) Process heaters Sulphur recovery Gas turbine Off-shore installation (Stainless steel AISI 316L case) Fittings Burner mounting fittings are available for Purging air Thermal isolation Adjustable aiming Cabling Sensor elements SF810 is available with the following three basic sensor modules covering the whole flame radiant spectrum of all fuels for boilers and industrial burners UV VL IR Dual sensor UVIR 4 SF810 is available with the following connection methods: Direct wiring to the on-board screw terminals Quick release connector Environment protection SF810 units are supplied for the following environments: ATEX II 2GD Ex d IIC T6 Gb Ex tb IIIC T 80 C Db IP66/67 IP66/67 4 Uvisor TM Fiber optic cable (FOC) assembly Symphony Plus Flame scanner Uvisor SF810 7

Contact us ABB S.p.A. Power Generation Genova, Italy Phone: +39 010 607 3229 Email: ci.supportcenter@it.abb.com ABB Inc. Power Generation Wickliffe, Ohio, USA Phone: +1 440 585 3087 Email: powergeneration@us.abb.com Copyright 2015 ABB All rights reserved. Specifications subject to change without notice. Pictures, schematics, and other graphics contained herein are published for illustration purposes only and do not represent product configurations or functionality. User documentation accompanying the product is the exclusive source for functionality descriptions. Symphony is a registered or pending trademark of ABB S.p.A. 3BUS095594 EN A4 Power Generation 1215 ABB Pte. Ltd. Power Generation Singapore Phone: +65 6776 5711 Email: powergeneration@sg.abb.com www.abb.com/powergeneration